HomeMy WebLinkAboutRES2007-00660 104 KLEINE LN BUILDING PERMITPREPARED 7/12/07, 11:17:53 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/12/07
------------------------------------------------------------------------------------------------
ADDRESS . : 104 KLEINE LN SUBDIV: EDELWEISS ESTATES PHS 12
CONTRACTOR B A CATHEY PHONE (979) 255-7064
OWNER . . PHONE
PARCEL . . 24400-1225-0010
APPL NUMBER: 07-00000660 RESIDENTIAL, 2 UNITS NEW (DUPLEX)
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/19/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
3/20/07 AP March 19, 2007 12:53:30 PM ncochran.
late afternoon
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 4/17/07 RH BLDG, FRAMING TIME: 17:00
4/17/07 AE April 17, 2007 8:58:24 AM kwolfe.
04/17/2007 04:22 PM RH PDA
Need anchors, and finish firewall over porch by insulation
inspection. Add chase for bath exhaust understairs.
B130 01 4/18/07 RH BLDG, INSULATION TIME: 17:00
4/18/07 AP April 18, 2007 8:14:31 AM ncochran.
LATE AS POSSIBLE
B125 0 7/12/0 BI BLDG, FINAL TIME: 17:00
July 12, 2007 10:51:17 AM kwolfe.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
No _=iz2JG4-7TivNv
(7/20/2007) Kim Wolfe - Re: Fwd: Calling for CO @ 104 Kleine Ln Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 7/19/2007 11:00 AM
Subject: Re: Fwd: Calling for CO @ 104 Kleine Ln
Contacted Blake Cathey at 255-7064 and he was made aware of the needed repairs.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Mitchell Carson 7/18/2007 12:47 pm >>>
The sewer clean our is buried and needs to be raised Mitch
>>> Kim Wolfe 07/17/07 10:35 AM >>>
>>> Kim Wolfe 7/12/2007 11:48 AM >>>
any issues?
BP # 07-660
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.csbc.gov
Date: 7/12/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 660
Address: 104 KLEINE LN
Insp.
Inspection Type Code
Description
si ins
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
04/17/2007 04:22 PM RH PDA
B115
BLDG, FRAMING
IC
Need anchors, and finish firewall over porch by insulation
B115
BLDG, FRAMING
IC
inspection. Add chase for bath exhaust understairs.
Ell
ELEC, ROUGH IN
IC
04/16/2007 02:27 PM RH PDA
E110
ELEC, ROUGH IN
IC
Bathroom exhaust fans on order. Install by framing.
M100
MECH, ROUGH IN
IC
April 17, 2007 11:17:28 AM kwolfe.
P100
PLBG, ROUGH IN
IC
03/16/2007 04:37 PM JGM PDA
P100
PLBG, ROUGH IN
IC
test not holding
Page 1
WFO881204 / 001 City of College Station
PAGE 1
REQ. DATE: 03/15/07 , 03/15/07 14:48:30
LOCATION: 104 KLEINE LN LOC ID: 207962
REQUESTOR: B A CATHEY ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP (TWO) 3/4" WTR TAPS
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/15/07 SCHED COMPLETION: 03/15/07
********************************************************************************
JOB ORDER RESULT COMMENTS
r j
Leflin!o/roof
construction
2nd store
Ow -
wall construction
same as first
5/8" Type X
drywa I 1 on
ceiling
Yam•. h.a, _. � _ _
Min 2x4 wall
w/8/8" Type
X drywa I l ea
side to roof
5/8 11 Type X
drywa I 1 on
' ceiling
min. 2x full
depth blocking
or rim joist ea
side
C yw s tee+,W c k
Ce'" It
2x& wa I i w/2x4
studs 16" o.c.
staggered on
each side. R-11
Insulation each
bay. 5/8" type X
drywall ea side
BUILDING PERMIT
CITY O'F'-- C&U LEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00000660 Date 3/15/07
104 KLEINE LN
24400-1225-0010
RESIDENTIAL, 2 UNITS NEW (DUPLEX)
EDELWEISS ESTATES PHS 12
RESIDENTIAL
DUPLEX RESIDENTIAL
165528
Owner Contractor
------------------------ ------------------------
B A CATHEY
PO BOX 9517
COLLEGE STATION TX 77842
(979) 255-7064
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 2508.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 6.00
NUMBER OF BEDROOMS 6.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit Fee . . . . 658.00 Plan Check Fee .00
Issue Date . . . . 3/15/07 Valuation . . . . 165528
Expiration Date . . 9/11/07
Qty Unit Charge Per Extension
BASE FEE 460.00
66.00 3.0000 THOU BLDG, VAL 100001-500000 198.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
------------------------------------------------ ------ -- -- --------------
BUILDING DEPT W ATIVE:
APPLICANT:
BUILDIMG PERMIT
CITY OIF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00000660 Date 3/15/07
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
1 HOUR DUPLEX SEPERATION WALL MUST BE MAINTAINED FROM FLOOR
TO ROOF DECKING. ALL PENETRATIONS MUST BE PROPERLY
ADDRESSED AND MAINTAINED.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
---------------------------------------------- ----- ---- --"-------------
BUILDING DEPT REPRES,$NTTATIVE : ,'
APPLICANT:
BUILDING PERMIT
CITY O-F COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00000660 Date 3/15/07
----------------------------------------------------------------------------
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
-----------
BUILDING DEPT REPRESENTTT V x -A
------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . .
07-00000660
Date
3/15/07
----------------------------------------------------------------------------
Special Notes and Comments
RANGE/DRYER DUCT MUST COMPLY
WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical)
WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS.
CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING
ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
800.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total 658.00
658.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 1150.00
1150.00
.00
.00
Grand Total 1808.00
1808.00
.00
.00
--------------------------------------------- ------ ---- ----- ------------
BUILDING DEPT REPRE ENTATIVE:
APPLICANT:
1 � �
CD
wI
O U 1
z
w
J < O
U
W J
0Q�
G
W
0.
0
Z x
C)
m � M
OLLF�
LL D Z os
. Z w O c >
O >�
�`"
Q � O
Q x
_U W CO 0
a
d C:
Q r. U c,
C
0
W
Q
z
w
Z
O
Cn
U)
w
z
U)
CD
L
w
z
0
w
2
O
O
U
Q
z
O
U
w
co
C,
z.
_U
I- U
U
J >
w S
`I
-q,
f
o
f
} CL
o O
lL Z J
OOO�U
Q �
O
Q
> Q
J CID F-
O
Q' Cn C/) U) F--
v
Q Q
TI
W
wIx
I- Ix
* Z
/)
Z
pw1�`
_O Q
c
U
VV
O
�z
ui Iz
>Q w
a
Z
GY ~ Q
Ow
cD C7 Q
_p
U t-ZQ
_
U
LJ
WLY- O
> 2i
0 1 LU
0 :,-
0
J Z
O;
O
a
`D
it
CID
T
Lu C @
_ @
CO c
W N m
O
Q 0 cu
d
Q.
O
z z
OQ o
0
0 Co
U
i- L)
>
r co
Q
U) Q v'
Z
O
LU
U \
O o
cB
O z �-
Z
U)-
:D¢
U
u3 cfl
C/) —J J
O
LU�
U Z
UDwD
r�
U)
OQ
z . _O
OLu
Q Q � �
U
a_
O
0 Q
<
Q
J
>
VW
PSA
W
a
}
}
_
W
LL
Z
O
O
w
0
Q
W
0
cr
m
w
w
z
z
x
O
z
?
w
LL
` ` I
U- U)
7LLI
` 1
I
w <
Q
w W Q Q <
V>F-
(.'
w w
w
cn cn 3: o
W
J
7
F-
d
r
m
OO 1
E u
o
D
n
W ul
J i
(D a
U) L
w
J
0
d
a
L
w
H
El
a
r
H
Q
Q
A
�— • _ w
Z = ♦ 1
cz
LL
-. N.
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) 9
Glazing SHGC qO
Glazing U-Factor 1 1-5
R value of ductwork
A/C SEER Rating
)3
Site Plan and Landscaping
Physical Address: 10,411,0(.. KLEir/L
Lot / , Block -:�5 , Phase 1.2 , Edelwiess Gartens Subdivision
E
Klein Lane
S 41.41'21" W 54.5'
S 41041'2"1" W 14,5'
Scale: 1 " = 20 ft
Notes:
(1) Lot to be fully irrigated
(2) Shared parking agreement to be recorded
(3) Landscaping Points to total 200 points per side
Cot')
(C)
(b)
MI
Plant Legend:
(a) Canopy Tree 1.5" — 2" at 75 pts per tree (live oak)
(b) Non canopy tree 1.25" or larger at 40 pts each (crepe myrtle)
(r) Shn the — .ri nal/Pa n 1(1 me nPr chn ih (mmy loaf lane mtn iml
Y!
Z
75
75
8
G� J
36m
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O
67 �0
DATE: 3 _ _d
BUILDING ADDRESS: � -
Zoq I ei,je
I. Foundation Requirements- MinimurnClity Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
1. One -hour rated extending to roof deck
N
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in ail hazardous locations
�J
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS'
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
NYOK
QYOK
A. Stairway Details
N
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 860
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/(OK)
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
Approved subdivision
Plat filed
;-&FO
Flood lain Regulations — Ordinance 1301
Does not block an water course or divert an flow
Elevation certificate needed
"APPROVED PLANS PER IRC SECTION R106.3.1."
alNS EXAMINER
3-13-01