HomeMy WebLinkAboutRES2007-00655 1521 HUNTER CREEK DR BUILDING PERMITPREPARED 8/10/07, 7:51:15 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/10/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1521 HUNTER CREEK DR SUBDIV: SHENANDOAH PH 19
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 569500-1947-0220
APPL NUMBER: 07-00000655 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/03/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
4/03/07 AP April 3, 2007 9:09:32 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 5/24/07 JGM BLDG, FRAMING TIME: 17:00
5/24/07 AP May 21, 2007 8:11:53 AM glsouth.
B130 01 5/31/07 OC BLDG, INSULATION TIME: 17:00
5/31/07 AP May 31, 2007 3:07:25 PM acarter.
May 31, 2007 3:19:37 PM glsouth.
B125 01 8/07/07 BI BLDG, FINAL TIME: 17:00
8/07/07 CA August 7, 2007 8:37:48 AM glsouth.
WED. MORNING
August 7, 2007 9:18:07 AM acarter.
CANCELLED PER PAM
B125 02 8 10/07 B
BLDG,
FINAL TIME: 17:00
�—
August
10, 2007 7:50:14 AM kwolfe.
------------------------I ----------
COMMENTS AND NOTES --------------------------------------
Date: 8/10/2007
Inspection Comments for Finais
Permit Year: 7 Permit Number: 655
Address: 1521 HUNTER CREEK DR
Type
Inspection Type Code
si tus
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B125
BLDG, FINAL
IC
August 7, 2007 9:18:07 AM acarter.
B125
BLDG, FINAL
IC
CANCELLED PER PAM
M110
MECH, FINAL
IC
Lawn Irrigation System Not Installed
P125
PLBG, FINAL
IC
July 13, 2007 11:39:44 AM kwolfe.
P125
PLBG, FINAL
IC
wrong address
Page 1
WF0880580 / 001 City of College Station PAGE 1
,--- ___ 4
REQ. DATE: 03/13/07 03/13/07 14:01:09
LOCATION: 1521 HUNTER CREEK DR LOC ID: 204822
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/13/07 SCHED COMPLETION: 03/13/07
********************************************************************************
JOB ORDER RESULT CON 4KNTS
City of College Station
110-1--.'T_E AS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 8/10/07
Parcel Number . . . . . 569500-1947-0220
Property Address . . . 1521 HUNTER CREEK DR
COLLEGE STATION TX 77845
Subdivision Name . . . SHENANDOAH PH 19
Legal Description . . . SHENANDOAH #19, BLOCK 47, LOT
22
Property Zoning . . . . SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . . . ED FROEHLING BUILDER INC
Contractor . . . . . . ED FROEHLING BUILDERS
979 776-8266
Application number 07-00000655 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone
Approved . . . . . . .
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILjQ,NG PERMIT
CITY OF COLLEGE STATION
1101 =XAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
ED FROEHLING BUILDER INC
3887 HIGH LONESOME
COLLEGE STATION TX
--- Structure Information 000
Construction Type . . . .
Occupancy Type . . . . .
Other struct info . . . .
07-00000655 Date 3/13/07
1521 HUNTER CREEK DR
569500-1947-0220
R304123
RESIDENTIAL, 1 UNIT DETACHED NEW
SHENANDOAH PH 19
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
134376
Contractor
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME RD
778459443 COLLEGE STATION TX 77845
(979) 776-8266
000 SINGLE FAMILY
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID DUE
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2036.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit Fee . . . . 565.00 Plan Check Fee .00
Issue Date . . . . 3/13/07 Valuation . . . . 134376
Expiration Date . . 9/09/07
Qty Unit Charge Per Extension
BASE FEE 460.00
35.00 3.0000 THOU BLDG, VAL 100001-500000 105.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZS 2211
------------------------------------------------- ----- -- -- ---------
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-000006SS
Page 2
Date 3/13/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BUILDING DEPT REPRESENTATIVE:
APPLICANT:--,..;-,--
�:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000655
Special Notes and Comments
Page 3
Date 3/13/07
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED
THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS
HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab,
seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER
TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
----------------------------------------------=i ----- f"----'--,.-#- ------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
PUILDENG PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000655 Date
3/13/07
----------------------------------------------------------------------------
Special Notes and Comments
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 565.00 565.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1315.00 1315.00 .00
.00
---------------------------------- ------.- -- ------- - - - - --
BUILDING DEPT REPRESENTATIVE: �_
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000656 Date 3/13/07
Property Address . . . . . . 1521 HUNTER CREEK DR
Property ID: 569500-1947-0220
R #: R304123
Application type description TEMP POLE
Subdivision Name . . . . . . SHENANDOAH PH 19
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . KW
Permit Fee . . . . 20.00
Issue Date . . . . 3/13/07 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
----------------------------------------------- ----- - ---------------
BUILDING DEPT REPRESENTATIVE-: �„_
APPLICANT:�� r v
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
�( For Ofte Use Only
DATE � " l TTRCC REG
APPLICATION # QY `J- U(5S^
TEMP POLE # -- 1
Planning cd Development Seim G
ADDRESS/LOCATION: �5Z ( I;uww Ck"
LOT 22- BLOCK 4-7 ---SUBDIVISION 51"ACCAJ4 1-�-- SEC/PH-J�"
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS: ZCM 1 M1 b
PHONE:
PHONE: -Mfp - 67"0
ua•.p Cf3rX'07"1
ELECTRICIAN: 15 T 15 MJBMF IC PLUMBER: -TIR
HVAC: % ANT 1 4. GOOD CENTS (Resid
CLASS OF WORK
ACCESSORY/STORAGE LOCATION
ADDITION MOVING 4
DEMOLITION (Asbestos Survey) EW CONSTRUCTION* SLABtb ' Y
DUPLEX (Landscape Plans) REMODEL/RENOVATION' S IMMING O
\ ROPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOC IATION/ARCHITECTUAL O
TEXAS ACCESSIBILITY STANDARD (TAS) PROy1E
VALUATION: $ 154, 74. Oy
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: 410
IVNATER TAP:
OTHER TAP:
ROOTOEMP POLE
GARAGE TYPE
21IZE814
7
SIZE
SIZE
DESIGN REVIEW COMMITTEE APPROVAL.
T REGISTRATION# EABPRJ
TOTAL AREA: 2531 HEATED AREA: =31Cp
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
SINGLE F-� DOUBLE Fi;�j TRIPLE
ATTACHED � DETACHED- a CARPORT
4
2
5jamy..
R1cx.
S arl aaq�
Gor
SIGNATURE OF APPLICANT: 1w-
'If proposed work involves new comme al c stru nor facade i ovements/renovations to an existing
commercial property, building elevations are req ed.
Official Use Only
f-iP Plans Examiner
— GJ
V-/ �v lam( S�
Zoning Official
;QRme
Dr NO
Fire Marshall
J
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
�3•cnl%
�3
30 �
13 5LM
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
- 6 �S - --- -
DATE:
3 _�- o
BUILDING ADDRESS: � .
( ;?-1 4qh e- CIL e�
I. Foundation Requirements- Minimum City Foundation Standards - - - - `- -
NA/OK "
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
NA/OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OK
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
NA/OK
1. One -hour rated extending to roof deck
NA/OK
E.
Header sizes indicated on plans
NA/OK
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roofcovering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
:4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS—
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings. -
III. Stairway Requirements
NA/OK
NA/OK
A. Stairway Details
NA/OK
- 1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral s airway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/OK
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/OK
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
,/
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/OK
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/OK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 860
NA/OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/OK
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/OK
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/OK
Does not block any water course or divert any flow
Elevation certificate needed
NA/OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
DATE
T
III-aP!s ,f
W
R
d
I
W
I
J
101 Ad rOCZ AA
OAIJG )t*aaO jig,;unH
,DO M — .3 .#CZ-Ctt S
,O'L£
� (A
v --
c
I
s-cs
,O-i
ca M
_
VV ��//�� .y�
♦U — W
r
N m
Z
L j
W
1ris� TF3
,S'LZ
r ,' &
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1217HB.rck
TITLE: 1521 HUNTER CREEK
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/01 /07
DATE OF PLANS: 4/08/05
PROJECT INFORMATION:
GINA COOPER
LOT 22 BLOCK 47
SHENANDOAH PHASE 19
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
GINA COOPER PLAN WITH T ADDED
NOW THE EXT. COOPER
COMPLIANCE: Passes
Maximum UA = 724
Your Home UA = 590
18.5% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2036
30.0
0.0
71
443
13.0
0.0
27
73
0.640 47
38
472 13.0 0.0
13
0.400 15
36
0.640 8
-, ti
Projection factor: 0.27
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.81
Wall 3: Wood Frame, 16" o.c. 443 13.0 0.0 26
Window 3: Metal Frame:Double Pane with Low-E 126 0.640 81
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Wall 4: Wood Frame, 16" o.c. 412 13.0 0.0 31
Window 4: Metal Frame:Double Pane with Low-E 36 0.640 23
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Unheated 206 0.0 215
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in
the RES checkInspecti St.
Builder/Desi n W A e