HomeMy WebLinkAboutCNEW2007-00646 RIVER RIDGE TOWNHOMES - CLUBHOUSE 1000 SPRING LOOP CLUB BUILDING PERMITi.'
Date 10 -8-01
Permit # 0 4
Project Name _Rive -of [RtAQe, Ctu�in e-
COMMERCIAL CO
Planning --:V
(Lindsay Boyer, Jennifer Prochazka, Jennifer Re vet s, Crissy Hrftl, Jason Schubert, Grant Wencel, Molly Hitchcock)
Bridgette George
Development Engineers
(Alan Gibbs, Josh Norton, Carol Cott(
City Engineer
(Bob Mosley, JergJoy
)Vrl�j
William I
Environmental Services
(Eaphrame Thomas, James Boykin, Pete Garcia)
Fire Departmentp
(Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith)
Drainage
(Donnie Willis)
Public Works - Sanitation
(Wally Urrutia)
Electrical Services
(Tony Michalsky)
Water/Wastewater Services �b
(Joe Mike Garcia, Paul Schoenfeld, Mitchell Carson) am
Miscellaneous Notes
PREPARED
1-0/18/07, 12:08:43
INSPECTION TICKET
PAGE 6
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 10/18/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 1000 SPRING LOOP
SUBDIV: UNIVERSITY PARK
#2
TENANT,
NBR: CLUBHOUSE
CONTRACTOR
OAKWOOD
CUSTOM HOMES PHONE (979) 690-1504
OWNER
RIVER RIDGE TOWNHOMES, LTD PHONE
PARCEL
620400-0221-0040
APPL NUMBER: 07-00000646 COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/02/07
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
4/02/07
AP
April 2, 2007 10:26:57 AM glsouth.
Slab Ground Installed
B115 01
6/13/07
DS
BLDG, FRAMING TIME: 17:00
6/13/07
AP
June 13, 2007 9:32:58 AM kwolfe.
B130 01
6/18/07
JGM
BLDG, INSULATION TIME: 17:00
6/19/07
DP
June 18, 2007 8:42:17 AM acarter.
06/19/2007 08:43 AM JGM PDA
fix overstuffed areas, replace insulation that
is not
31/2" thick, insulate around doors
B130 02
6/19/07
DS
BLDG, INSULATION TIME: 17:00
6/20/07
AP
June 19, 2007 9:09:14 AM acarter.
B125 01
9/28/07
DS
BLDG, FINAL TIME: 17:00
10/04/07
DP
September 28, 2007 11:27:15 AM acarter.
10/04/2007 04:41 PM DS PDA
signage for doors with more than 1 throw of
the hand
address ramp for front door over 1/2 "rise
BQ.25 02
10/18/07
BI
BLDG, FINAL TIME: 17:00
October 18, 2007 10:45:40 AM acarter.
-----------------------------------
--LOMMENTS AND NOTES ------------------------
v
Amber Carter - Re: Calling for C.O. for 1000tSpring Loop (Clubhouse) T
From: Paul Schoenfeld
To: Alan Gibbs; Amber Carter; Benjamin McCarty; ...
Date: 9/28/2007 4:09 pm
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
NO FOR CO.
Fire hydrant lead valve covered and Fire hydrant can't be accessed because of landscape planting.
Planting closet is a minumn of 3 feet.
Paul
>>> Amber Carter 9/28/2007 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Cfczarzak @ 412-2320
Chris Haver - River Ridge Townhomes on Spring Loop Page 1
From: Jennifer Prochazka
To: Chris Haver
Date: 10/19/2007 11:06:40 AM
Subject: River Ridge Townhomes on Spring Loop
Chris,
I inspected the Clubhouse (Phase IV). Here are my comments:
1. An amended landscape plan should be submitted for this phase, as the approved landscape plan was
deviated from.
2. A minimum of 2 3.5-inch caliper trees are required in this phase. Only one has been provided and it is
less than 3.5-inches (measured at 12" above grade), and it looks to be in poor health.
Jennifer Prochazka, AICP
Senior Planner
Dept. of Planning & Development Services
City of College Station
tel.: 979.764.3570
fax: 979.764.3496
www. cstx. qov
Amber Carter - Re. Calling for C.O.for 1000 Spring Loop (Clubhouse)
From: Jerry Duffey
To: Amber Carter
Date: 9/28/2007 1:22 pm
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
CC: Benjamin McCarty; Chris Haver; Eric Dotson; ...
Needs Knox Switch for the front entrance ............ so NO
>>> Amber Carter 09/28/07 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Ofczarzak @ 412-2320
Amber Carter - Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
Page 1
From: James Boykin
To: Alan Gibbs; Amber Carter; Benjamin McCarty; ...
Date: 10/4/2007 2:41 pm
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
Environmental Services has received the backflow test report for the clubhouse's irrigation. Okay for a
TEMPORARY CO until they finish out the plumbing for the pool, hot tub, and fountain.
James Boykin
Environmental Technician
Water Services Department
979-764-6312
May the most you wish for be the least you get.
>>> Amber Carter 9/28/2007 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Cfczarzak @ 412-2320
Amber Carter - Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
From: Donnie Willis
To: Carter, Amber
Date: 9/28/2007 2:34 pm
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
OK for TEMP.
Can not approve final CO until project is complete.
Donnie Willis, CFM
Environmental Engineering Technician
Certified Floodplain Manager
Public Works Department
979-764-6375 office
979-229-7632 cell
dwillis@cstx.gov
>>> On 9/28/2007 at 1:19 pm, in message<46FCFF71.1265.003D.0@cstx.gov>, Amber Carter wrote:
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Ofczarzak @ 412-2320
PREPARED 1-0/26/07, 8 : 0 6 : 3 9 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/26/07
------------------------------------------------------------------------------------------------
ADDRESS . : 1000 SPRING LOOP SUBDIV: UNIVERSITY PARK #2
TENANT, NBR: CLUBHOUSE
CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504
OWNER RIVER RIDGE TOWNHOMES, LTD PHONE
PARCEL 620400-0221-0040
APPL NUMBER: 07-00000646 COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/02/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
4/02/07 AP April 2, 2007 10:26:57 AM glsouth.
Slab Ground Installed
B115 01 6/13/07 DS BLDG, FRAMING TIME: 17:00
6/13/07 AP June 13, 2007 9:32:58 AM kwolfe.
B130 01 6/18/07 JGM BLDG, INSULATION TIME: 17:00
6/19/07 DP June 18, 2007 8:42:17 AM acarter.
06/19/2007 08:43 AM JGM PDA
fix overstuffed areas, replace insulation that is not
31/2" thick, insulate around doors
B130 02 6/19/07 DS BLDG, INSULATION TIME: 17:00
6/20/07 AP June 19, 2007 9:09:14 AM acarter.
B125 01 9/28/07 DS BLDG, FINAL TIME: 17:00
10/04/07 DP September 28, 2007 11:27:15 AM acarter.
10/04/2007 04:41 PM DS PDA
signage for doors with more than 1 throw of the hand
address ramp for front door over 1/2 "rise
B125 02 10/18/07 DS BLDG, FINAL TIME: 17:00
10/19/07 DP October 18, 2007 10:45:40 AM acarter.
October 19, 2007 8:46:50 AM kwolfe.
exit lights not working
more than 1/2 rise on entry door
handrails for steps at front door
ned alarm on both doors going to pool area
label rest of panel
need to install outlet for lawn sprinker system properly
B125 03 10/2F/07 BLDG, FINAL TIME: 17:00
October 26, 2007 8:03:30 AM acarter.
��-------- COMMENTS D NOTES --------------------------------------
� I X—�
Date: 10/26/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 646
Address: 1000 SPRING LOOP
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B125
BLDG, FINAL
IC
10/04/2007 04:41 PM DS PDA
B125
BLDG, FINAL
IC
signage for doors with more than 1 throw of the hand
B125
BLDG, FINAL
IC
address ramp for front door over 1/2 "rise
B125
BLDG, FINAL
IC
October 19, 2007 8:46:50 AM kwolfe.
B125
BLDG, FINAL
IC
exit lights not working
B125
BLDG, FINAL
IC
more than 1/2 rise on entry door
B125
BLDG, FINAL
IC
handrails for steps at front door
B125
BLDG, FINAL
IC
ned alarm on both doors going to pool area
B125
BLDG, FINAL
IC
label rest of panel
B125
BLDG, FINAL
IC
need to install outlet for lawn sprinker system properly
B130
BLDG, INSULATION
IC
06/19/2007 08:43 AM JGM PDA
B130
BLDG, INSULATION
IC
fix overstuffed areas, replace insulation that is not
B130
BLDG, INSULATION
IC
31/2" thick, insulate around doors
E150
ELEC, FINAL
IC
10/04/2007 04:15 PM DS PDA
E150
ELEC, FINAL
IC
breaker tripping panel not labeled
M100
MECH, ROUGH IN
IC
06/05/2007 02:59 PM DS PDA
M100
MECH, ROUGH IN
IC
duct work needs to be cut as short and tight as possible
M100
MECH, ROUGH IN
IC
need to remove duct board plieum off water pipies bath
M100
MECH, ROUGH IN
IC
exchaust fans need to be installed and min 75 c.f.m.
P125
PLBG, FINAL
IC
09/26/2007 04:07 PM DS PDA
P125
PLBG, FINAL
IC
needs open front toilet seats
Page 1
Amber Carter - Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
From: James Boykin
To: Alan Gibbs; Amber Carter; Benjamin McCarty; ...
Date: 10/1/2007 3:29 pm
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
NO for CO. Environmental Services requires the original backflow test report for the irrigation system
(Ser# ADC79). Also, we will need to inspect the plumbing for the pool, hot tub, and fountain for proper
backflow protection. After we receive the test report for the irrigation, we would be okay with issuing a
TEMPORARY CO until they finish the pool's plumbing and install and test the proper backflow devices.
James Boykin
Environmental Technician
Water Services Department
979-764-6312
May the most you wish for be the least you get.
>>> Amber Carter 9/28/2007 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Cfczarzak @ 412-2320
Date: 10/4/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 646
Address: 1000 SPRING LOOP
Insp.
Inspection Type Code
Description
si ins
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
06/19/2007 08:43 AM JGM PDA
B130
BLDG, INSULATION
IC
fix overstuffed areas, replace insulation that is not
B130
BLDG, INSULATION
IC
31/2" thick, insulate around doors
M100
MECH, ROUGH IN
IC
06/05/2007 02:59 PM IDS PDA
M100
MECH, ROUGH IN
IC
duct work needs to be cut as short and tight as possible
M100
MECH, ROUGH IN
IC
need to remove duct board plieum off water pipies bath
M100
MECH, ROUGH IN
IC
exchaust fans need to be installed and min 75 c.f.m.
P125
PLBG, FINAL
IC
09/26/2007 04:07 PM DS PDA
P125
PLBG, FINAL
IC
needs open front toilet seats
Page 1
WFO882607 / 001 City of College_'Station
PAGE 1
REQ. DATE: 03/21/07 03/21/07 15:48:31
LOCATION: 1000 SPRING LOOP LOC ID: 208400
EXT. ADDR.: CLUB HOUSE REF NBR:
REQUESTOR: OAKWOOD CUSTOM HOMEBUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
3/4" WTR 3/4" IRRIGATION
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/21/07 SCHED COMPLETION: 03/21/07
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
11/19/07
620400-0221-0040
1000 SPRING LOOP
COLLEGE STATION TX 77840
UNIVERSITY PARK #2
UNIVERSITY PARK #2, BLOCK U, L
OT 4R
UNKNOWN
Owner . . . . . . . . . RIVER RIDGE TOWNHOMES, LTD
Contractor . . . . . . OAKWOOD CUSTOM HOMES
979 690-1504
Application number 07-00000646 000 000
Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . ASSEMBLY (IBC)
Flood Zone . . . . . .
Approved
�A4-
ng Offici
VOID UNLESS SIGNED BY BUILDING OFFICIAL
TRANSMISSION VERIFICATION REPORT
TIME 11/19/2007 14:37
NAME
FAX
TEL
SER.# 000L5J596800
DATE DIME
11/19 14:37
FAX NO./NAME
96902504
DURATION
00:00:22
PAGE(S)
02
RESULT
OK
MODE
STANDARD
ECM
, Al2'OL
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
FACSIMILE COVER SHEET
Date: # of pages including cover:
If you did not receive a complete fax, please call our office immediately for a new transmittal.
TO; tAooie-
COMPANY:
RE:
FROM:-LLri.5 40.ve'l
FAX; 06 -aZ6oq---
COMPANY: -City of College Station
PTIN/T ADTrC. F-1 T T�n 4- FXAv,, vr.F-1 A C A P F-I'PVT
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
T E M P O R A R Y C O
T E M P O R A R Y
Issue Date . . . . . . 11/14/07
Expiration Date . . . . 11/30/07
Parcel Number . . . . . 620400-0221-0040
Property Address . . . 1000 SPRING LOOP
COLLEGE STATION TX 77840
Subdivision Name . . . UNIVERSITY PARK #2
Legal Description . . . UNIVERSITY PARK #2, BLOCK U, L
OT 4R
Property Zoning . . . . UNKNOWN
Owner . . . . . . . . . RIVER RIDGE TOWNHOMES, LTD
Contractor . . . . . . OAKWOOD CUSTOM HOMES
979 690-1504
Application number 07-00000646 000 000
Description of Work COMMERCIAL, AMUSEMENT/SOCIAL/RECREATION
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . ASSEMBLY (IBC)
Flood Zone . . . . . .
Special conditions . .
Detention pond outlet structure, specifically under the
sidewalk, needs to be clear of debris.
Approved . . . . . . 0A J
ttffldincr
'ficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
Chris Haver - River Ridge Issues - Revised Page 1
From: Josh Norton
To: Haver, Chris
Date: 11/13/2007 10:47:47 AM
Subject: River Ridge Issues - Revised
Chris sorry for the confusion, here are the issues that have not yet been addressed. I have not heard
back from Logan yet.
Issues:
*Detention Pond outlet structure, specifically under the sidewalk needs to be clear of debris
>>> Chris Haver 11/13/07 9:43 AM >>>
Can you let me know if you have any outstanding issues. Thanks.
Chris Haver - River Ridge Issues Page 1
From:
Josh Norton
To:.
Haver, Chris
Date:
10/31 /2007 8:44:20 AM
Subject:
River Ridge Issues
Issues:
*Replace the portion of the concrete drive isle that was previously removed in the rear of the site on the
adjacent property where orange fence is currently located.
*Detention Pond needs to have established vegetation - seed or sod
"Detention Pond outlet structure, specifically under the sidewalk needs to be clear of debris
Amber Carter - Re: Calling for C 0. for 1000 Spring Loop (Clubhouse) 1
From: Donnie Willis
To: Carter, Amber
Date: 9/28/2007 2:34 pm
Subject: Re: Calling for C.O.
OK for TEMP.
for 1000 Spring Loop (Clubhouse)
Can not approve final CO until project is complete.
Donnie Willis, CFM
Environmental Engineering Technician
Certified Floodplain Manager
Public Works Department
979-764-6375 office
979-229-7632 cell
dwillis@cstx.gov
>>> On 9/28/2007 at 1:19 pm, in message<46FCFF71.1265.003D.0@cstx.gov>, Amber Carter wrote:
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Ofczarzak @ 412-2320
Ehris Haver - Re: River Ridge Page 1
From: John Logan
To: Alan Gibbs; Chris Haver; Josh Norton
Date: 10/31 /2007 7:56:05 AM
Subject: Re: River Ridge
Good Morning All, River Ridge has a few issues they have known about for months.
1. The outlet structure needs a 4"x 4" curb and 36" clear path to meet TAS and ADA regs
2. They need to uncover 1 existing valve on the West end of the property and 1 new valve on the East
end.
3. The existing Fire Hydrant needs to have sufficient space to operate the hydrant and the forms need to
be removed from the valve box pad.
I know Water Services has issues inside the project that need to be addressed.
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS? A"�FE--- -1
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000646 Date 3/21/07
Property Address . . . . . . 1000 SPRING LOOP
Property ID: 620400-0221-0040
R #: R45733
Tenant nbr, name . . . . . . CLUBHOUSE
Application type description NEW, u11,
Subdivision Name . . . . . . UNIVERSITY PARK #2 PC�V9_*IC
Property Use . . . . . . . . Y-tctt4ctioY1
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 200000
Owner Contractor
------------------------ ------------------------
RIVER RIDGE TOWNHOMES, LTD OAKWOOD CUSTOM HOMES
4060 SH 6 S 4060 SH 6 S
COLLEGE STATION TX 77845 COLLEGE STATION TX 77845
(979) 690-1504
--- Structure Information 000 000 APARTMENT CLUBHOUSE STRUCTURE
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . ASSEMBLY (IBC)
Other struct info . . . . . EXTERIOR WALL TYPE 2X4
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 1650.00
INTERIOR WALL TYPE 2X4
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 1.00
SEWER TYPE PUBLIC
TAZ 222.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit Fee . . . . 760.00 Plan Check Fee .00
Issue Date . . . . 3/21/07 Valuation . . . . 200000
Expiration Date . . 9/17/07
Qty Unit Charge Per Extension
BASE FEE 460.00
100.00 3.0000 THOU BLDG, VAL 100001-500000 300.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS
REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT D WALKWAY
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
4 f
I f 1
r
r
BUILDING PERMIT
CITY OF COLLEGE STATION Y
1101 TEXAS,AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00000646 Date 3/21/07
----------------------------------------------------------------------------
Special Notes and Comments
Permit Number provided by the COCS shall be conspicuously
posted in the lower right hand corner of the banner.
Shall be mounted parallel to the face of a building or
permanent structure.
Shall advertise only the name of, uses of, or goods or
services available within the building or tenant lease
space to which the banner is attached.
Shall not be located within public road ROW (State or
Local).
Shall not obstruct any window, door, stairway, or other
opening inteded for ingress or for needed ventilation or
light.
Shall not exceed the top of the structure to which it is
attached.
Shall advertise only the name of, uses of, or goods or
services available within the building, or tenant lease
space, to which the banner is attached.
Shall be mounted parallel to the face of the building.
Shall not be cantilevered away from the structure.
Shall not extend more than one foot from any exterior
building face, mansard, awning, or canopy.
Shall not obstruct any window, door, stairway, or other
opening intended for ingress or for needed ventilation or
light.
Shall not be attached to any tree, fence, or public utility
pole.
NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR
CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT
CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS.
ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED
TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC
UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM
BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394.
ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD42394
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
------
------------------------------- CI - -----------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS,AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
07-00000646
Page 3
Date 3/21/07
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
REQUIRED EXIT DOOR(S)
PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT
WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROVIDE MINIMUM 42" CLEARANCE FROM CENTER OF WATER CLOSET TO
EDGE OF LAVATORY
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS.
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
All outdoor lighting must be in compliance with Section
7.10, Outdoor lighting Standards of the City's Unified
Development Ordinance
All roof and ground -mounted mechanical equipment shall be
sreened from view or isolated so as not to be visible from
any public right-of-way or residential district within 150
feet of the subject lot, measured from a point five feet
above grade. Such screening shall be coordinated with the
building architecture and scale to maintain a unified
appearance. Acceptable methods of screening rooftop
equipment may include, but are not limited to encasement,
parapet walls, or partition screens.
COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER
CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE
STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER
CONDUIT FROM THE TRANSFORMER.
(see site plan for location of conduit or contact
electrical division)
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
ON NARROW WALL BRACING WHERE SPECIAL NAILIN PATTERN,
----------------------------------------_d •_______--__________-_____
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS-AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000646 Date
3/21/07
----------------------------------------------------------------------------
Special Notes and Comments
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
PROVIDE PANIC HARDWARE ON EXIT DOORS
T� V �_. i_ i_ i
.L� PEA water supply piping is sleeveu r�elow the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
AS PER THE ZONING ORDINANCE SECTION 12.3.L; ATTACHED
SIGNS SHALL NOT EXTEND MORE THAN ONE FOOT AWAY
FROM EXTERIOR BUILDING FACE
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO
THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR @
(512) 463-3211 FOR MORE INFORMATION
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . WATER TAP 3/4"
800.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 760.00 760.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 800.00 800.00 .00
.00
Grand Total 1560.00 1560.00 .00
.00
14 -------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS-AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000646
------------------------------------------ cQ_6a9-
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
Page 5
Date 3/21/07
b3 (off o 0
APPLICATION FOR BUILDING PERMIT DATE: T CC RE(G�
CITY OF COLLEGE STATION APPLICATION # (D 1
t* ff 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE #
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning&Dr Igpmmt,%mica
WWW.CSTX.GOV
ADDRESS/LOCATIONJ000 SPRING LOOP PHASE IV (CLUBHOUSE)
LOT _ BLOCK SUBDIVISION UNIVERSITY PARK SEC/PH 2 REPLAT
BUSINESS/OWNER NAME: ALTON OFCZARZAK
PHONE 979-690-1504
CONTRACTOR/HOMEOWNER: OAKWOOD CUSTOM HOMEBUILDERS PHONE:979-690-1504
CONTRACTOR ADDRESS: 4060 HIGHWAY 6 SOUTH COLLEGE STATION, TEXAS 77845
ELECTRICIAN: MATHIEWS ELECTRIC
HVAC: THREE RIVERS
PLUMBER: AGGILAND PLUMBING
_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: NEW CONSTRUCTION
CLUBHOUSE
STRUCTURE USE: COMMUNITY CENTER
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJA7810887
VALUATION: $ 200,000
(Cost of Labor and Materials)
TOTAL AREA:1750
OX PUBLIC SEWER NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
SIZE
WATER TAP: 3/4"/ EXTERIOR WALL TYPE:
SIZE
CIO 0.O� � OTHER TAP: �(4 rre.54'1 A-, FOUNDATION TYPE:
SIZE
❑ TEMP POLE
GARAGE TYPE
O�
S b�'
SINGLE El
ATTACHED
ROOF TYPE:
DOUBLE TRIPLE
DETACHED CARPORT
HEATED AREA:1650
2
2X4 @ 16 OC
2X4 @ 16 OC
SLAB ON GRADE
30 YR COMP. SHINGLE
I SIGNATURE OF APPLICANT: 66�� a3�07 /D7
*If proposed work involves new commercial construction or facade improvements/renovat�an existing
commercial property, building elevations are required.
Official Use Only
h�y Comments:
[%/`ycv e".$sr 9 Xpor NO
Plans Examiner Zoning Official
Nc-
, J
Energy Code Compliance Information
% Glazing of exterior walls 27
Insulation R value of exterior walls 13
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) 19
Glazing SHGC .37
Glazing U-Factor .59
R value of ductwork 6-8
A/C SEER Rating 13
M
�( CONIcheck Software Version 3.3.0
Envelope Compliance Certificate
2003 IECC
Report Date: 03/07/07
Data filename: G:\OAK-DWG\SPRING-1\GLUBHO-lkCLUBHO-I.CCK
Section 1: Project Information
Project Title: RIVER RIDGE CLUBHOUSE
Construction Site: Owner/Agent: Designer/Contractor:
1000 SPRING LOOP ALTON OFCZARZAK DAVID PARK
COLLEGE STATION, TX 77845 OAKWOOD CUSTOM HOMES GROUP OAKWOOD CUSTOM HOMES GROUP
LTD. LTD.
4060 HIGHWAY 6 SOUTH 4060 HIGHWAY 6 SOUTH
COLLEGE STATION, TX 77845 COLLEGE STATION, TX 77845
979-690-1504 979-690-1504
ALTON@OAKCHB.COM DAVE@OAKCHB.COM
Section 2: General Information
Building Location (for weather data):
College station, Texas
Climate Zone:
415
Heating Degree Days (base 65 degrees F):
1788
Coding Degree Days (base 65 degrees F):
2776
Project Type:
New Construction
Vertical Glazing / Wall Area Pct:
27%
Activity Twets)
Floor Area
Office
143
Kitchen
62
Exhibition Hall
203
Convention, Conference or Meeting Center
319
Convention, Conference or Meeting Center
174
Corridor, Restroom, Support Area
55
Corridor, Restroom, Support Area
55
Exercise Center
171
Lobby - Other
265
Office
143
Section 3: Requirements Checklist
Env'elope.PASSESTDTMK19F,5 LM tt ET ffan cod
Climate -Specific Requirements:
Component Name/Description
FLAT CLG: All -Wood Joist/Rafter/Truss
CATHEDRAL CLG: All -Wood Joist/Rafterlrruss
Exterior Wall 1: Wood Frame, Any Spacing
3060SH X4: Metal Frame:Double Pane with Low-E, Clear, SHGC
0.37
3060 fix x 8: Metal Frame:Double Pane with Low-E, Clear, SHGC
0.37
4050FX X4: Metal Frame:Double Pane with Low-E, Clear, SHGC
0.37
RIVER RIDGE CLUBHOUSE
Gross Area Cavity Cont. Proposed Budget
or Perimeter R Value R-Value U-Factor U-Factor
981
0.0 30.0 0.032
0.063
768
19.0 0.0 0.054
0.063
1677
13.0 0.0 0.091
0.207
72
-- -- 0.590
1.230
144 — — 0.590 1.230
80 -- -- 0.590 1.230
Page 1 of 10
4016 A: Metal Frame:Double Pane with Low-E, Clear, SHGC 0.37
24 —
--- 0.590
1230
triangle x 4: Metal Frame:Double Pane with Low-E, Clear, SHGC
58 —
— 0.590
1.230
0.37
'
6016 trans: Metal Frame:Double Pane with Low-E, Clear, SHGC
9 —
— -0.590
1.230
0.37
3016 trans x2: Metal Frame:Double Pane with Low-E, Clear, SHGC
10 —
— 0.590
1.230
0.37
3068 full lite x 3: Glass, Clear, SHGC 0.37
60 —
— 0.260
1.230
Floor 1: Slab-On-Grade:Unheated
162 —
— —
—
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
Air Leakage, Component Certification, and Vapor Retarder Requirements:
❑ 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in
accordance with the manufacturer's installation instructions.
2. Windows, doors, and skylights certified as meeting leakage requirements.
3. Component R values & U-factors labeled as certified.
4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
LJ 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers.
O 6. Cargo doors and loading dock doors are weather sealed.
Lj 7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly
with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material.
Note: Vapor retarder not required in this location.
Section 4: Compliance Statement
Compliance Statement: The proposed envelope design represented In this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC
requirements in COMcheck Version 3.3.0 and to comply with the mandatory requirements in the Requirements Checklist.
Name - Title Signature Date
Project Notes:
RIVER RIDGE CONDOMINIUM STYLE TOWNHOME COMPLEX CLUBHOUSE
RIVER RIDGE CLUBHOUSE Page 2 of 10
�( COMcheck Software Version 3.3.0
Lighting Compliance Certificate
2003 IECC
Report Date: 03/07/07
Data filename: G:\OAK DWG\SPRING-1\CLUBHO-1\CLUBHO-1.CCK
Section 1: Project Information
Project Title: RIVER RIDGE CLUBHOUSE
Construction Site: Owner/Agent: Designer/Contractor:
1000 SPRING LOOP ALTON OFCZARZAK DAVID PARK
COLLEGE STATION, TX 77845 OAKWOOD CUSTOM HOMES GROUP OAKWOOD CUSTOM HOMES GROUP
LTD. LTD.
4060 HIGHWAY 6 SOUTH 4060 HIGHWAY 6 SOUTH
COLLEGE STATION, TX 77845 COLLEGE STATION, TX 77845
97M90-1504 979-690-1504
ALTON@OAKCHB.COM DAVE@OAKCHB.COM
Section 2: General Information
Building Use Description by: Activity Type
Project Type: New Construction
Activity Tvoe(s)
Floor Area
Office
143
Kitchen
62
Exhibition Hall
203
Convention, Conference or Meeting Center
319
Convention, Conference or Meeting Center
174
Corridor, Restroom, Support Area
55
Corridor, Restroom, Support Area
55
Exercise Center
171
Lobby - Other
265
Office
143
Section 3: Requirements Checklist
Interior Lighting:
O 1. Total actual watts must be less than or equal to total allowed watts.
Allowed Watts Actual Watts Compiles
1891 1856 YES
2. Exit signs 5 Watts or less per side.
Exterior Lighting:
O 3. Efficacy greater than 45 lumens/W.
Exceptions:
Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape
lighting.
Controls, Switching, and Wiring:
4. Independent controls for each space (switch/occupancy sensor).
Exceptions:
Areas designated as security or emergency areas that must be continuously illuminated.
RIVER RIDGE CLUBHOUSE Page 3 of 10
Lighting in stairways or corridors that are elements of the means of egress.
5. Master switch at entry to hotel/motel guest room.
❑-6. Individual dwelling units separately metered.
Ll 7. Each space provided with a manual control to provide uniform light reduction by at least 50%.
Exceptions:
Only one luminaire in space;
An occupant -sensing device controls the area;
The area is a corridor, storeroom, restroom, public lobby or guest room;
Areas that use less than 0.6 Watts/sq.ft
8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft.
9. Photocell/astronomical time switch on exterior lights.
Exceptions:
Lighting intended for 24 hour use.
10. Tandem wired one4amp and three -lamp ballasted luminaires (No single -lamp ballasts).
Exceptions:
Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair.
Section 4: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications
and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003 IECC,
Chapter 8, requirements in COMcheck Version 3.3.0 and to comply with the mandatory requirements in the Requirements Checklist.
, Y"i.� S-ham N& l AA.- DL"' 0 6 7
Name - Title Signature Date
RIVER RIDGE CLUBHOUSE Page 4 of 10
e(ICOMcheck Software Version 3.3.0
Lighting Application Worksheet
2003 IECC
Report Date:
Data filename: G:\OAK DWG\SPRING-1\CLUBHO-1\CLUBHO-1.CCK
Section 1: Allowed Lighting Power Calculation
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
Is x C)
Office
143
1.1
157
Kitchen
62
1.2
74
Exhibition Hall
203
1.3
264
Convention, Conference or Meeting Center
319
1.3
415
Convention, Conference or Meeting Center
174
1.3
226
Corridor, Restroom, Support Area
55
0.9
50
Corridor, Restroom, Support Area
55
0.9
50
Exercise Center
171
0.9
154
Lobby - Other
265
1.3
344
Office
143
1.1
157
Total Allowed Watts = 1891
Section 2: Actual Lighting Power Calculation
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
.rocePtion
Incandescent 1: Incandescent 60W
4
1
240
��
240
exercise
Linear Fluorescent 1: 48" T12 40W / Magnetic
—
_ 4
2
160
320
billiard room
canopy light: Incandescent 40W
3
1
120
120
Incandescent 4: Incandescent 60W
4
1
240
240
Incandescent 5: Incandescent 60W
1
4
60
240
I.,_.. --
media room _
Incandescent 6: Incandescent 60W
1
4
60
240
_kitchen _
Linear Fluorescent 2: 48" T12 40W / Magnetic
2
1
84
84
yroom
Linear Fluorescent 3: 48" T12 40W / Magnetic
2
1
84
84
`bath T
Incandescent 7: Incandescent 60W
1
2
60
120
,office
v
—
Linear Fluorescent 4: 48" T12 40W / Magnetic
2
2
84
168
Total Actual Watts =
1856
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies.
Total Allowed Watts = 1891
RIVER RIDGE CLUBHOUSE Page 5 of 10
Total Actual Watts = 1856
Project Compliance = 35
Lighting PASSESIDesig. ° b t gCcQd
RIVER RIDGE CLUBHOUSE Page 6 of 10
eCOMcheck Software Version 3.3.0
�(, Mechanical Compliance Certificate
2003 IECC
Report Date: 03/07/07
Data filename: G:\OAK DWG\SPRING-1\CLUBHO-1\CLUBHO-1.CCK
Section 1: Project Information
Project Title: RIVER RIDGE CLUBHOUSE
Construction Site: Owner/Agent: Designer/Contractor:
1000 SPRING LOOP ALTON OFCZARZAK DAVID PARK
COLLEGE STATION, TX 77845 OAKWOOD CUSTOM HOMES GROUP OAKWOOD CUSTOM HOMES GROUP
LTD. LTD.
4060 HIGHWAY 6 SOUTH 4060 HIGHWAY 6 SOUTH
COLLEGE STATION, TX 77M COLLEGE STATION, TX 77845
979-690-1504 979-690-1504
ALTON@OAKCHB.COM DAVE@OAKCHB.COM
Section 2: General Information
Building Location (for weather data): College Station, Texas
Climate Zone: 4b
Heating Degree Days (base 65 degrees F): 1788
Cooling Degree Days (base 65 degrees F): 2776
Project Type: New Construction
Section 3: Mechanical Systems List
Quantity System UR§ & Description
1 HVAC System 1: Split System Heat Pump, Cooling Capacity —135 - <240 kBtu/h, Air -Cooled Condenser /
Single Zone
1 Storage Water Heater 1: Service Water Heater
Section 4: Requirements Checklist
Requirements Specific To: HVAC System 1 :
Lj 1. Equipment minimum efficiency: Heat Pump: 3.1 COP, 9.3 EER
o 2. Heat pump thermostat required when supplemental electric resistance heat is installed
Ll 3. Integrated air economizer required
Requirements Specific To: Storage Water Heater 1
Ll 1. Heat traps in Inlettoutlet fittings
❑ 2. 1/2-in. insulation on 8 ft of inlet/outlet piping if no integral heat traps
Li 3. Electric Water Heater efficiency — 0.88 EF, 241 SL, Btu/h (if > 12 kW)
Generic Requirements: Must be met by all systems to which the requirement is applicable:
1. Load calculations per 2001 ASHRAE Fundamentals
0 2. Plant equipment and system capacity no greater than needed to meet loads
- Exception: Standby equipment automatically off when primary system is operating
- Exception: Multiple units controlled to sequence operation as a function of load
3. Minimum one temperature control device per system
Ll 4. Minimum one humidity control device per installed humidification/dehumidification system
RIVER RIDGE CLUBHOUSE Page 7 of 10
5. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2-hour occupant override, 10-hour
backup
Exception: Continuously operating zones
- Exception: 2 kW demand or less, submit calculations
L] 6. Automatic shut-off dampers on exhaust systems and supply systems with airflow >3,000 kfm
[] 7. Outside -air source for ventilation; system capable of reducing OSA to required minimum
[] 8. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building
R-8 insulation between ducts and the building exterior when ducts are part of a building assembly
- Exception: Ducts located within equipment
- Exception: Ducts with interior and exterior temperature difference not exceeding 15 degrees F.
0 9. Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181B tapes and mastics
- Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less
than 2 inches w.g. pressure classification
0 10. Mechanical fasteners and sealants used to connect ducts and air distribution equipment
11. Hot water pipe insulation: 1 in. for pipes —1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerantUne pipe insulation: 1 in.
for pipes —1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes —1.5 in. and 3 in. for pipes >1.5 in.
- Exception: Piping within HVAC equipment
- Exception: Fluid temperatures between 55 and 105 degrees F
- Exception: Fluid not heated or cooled
- Exception: Runouts <4 ft in length
LJ 12. Operation and maintenance manual provided to building owner
LJ 13. Balancing devices provided in accordance with IMC 603.15
Lj 14. Newly purchased service water heating equipment meets the efficlency requirements
L] 15. Water heater temperature controls: 110 degrees F for dwelling units or 90 degrees F for other occupancies
16. Stair and elevator shaft vents are equipped with motorized dampers
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to
meet the 2003 IECC requirements in COMcheck Version 3.3.0 and to comply with the mandatory requirements in the Requirements
Checklist.
�) S
Name -Title J Signature Date
RIVER RIDGE CLUBHOUSE Page 8 of 10
�( COMcheck Software Version 3.3.0
Mechanical Requirements
Description
2003 IECC
Report Date:
Data filename: G:%OAK DWG%SPRING--1%CLUBHO-11CLUBHO-1.CCK
The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance
Certificate.
Requirements Specific To: HVAC System 1 :
The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum
efficiency: Heat Pump: 3.1 COP, 9.3 EER
Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary
heat operation when the heat pump can meet the heating load.
3. An integrated air economizer is required for individual cooling systems over 65 kBtu/h in the selected climate. An integrated
economizer allows simultaneous operation of outdoor -air and mechanical cooling.
Requirements Specific To: Storage Water Heater 1 :
1. Heat traps are required on noncirculating water heating systems on both inlet and outlet connections. Heat traps may be purchased
or field -fabricated by creating a loop or inverted U-shaped arrangement on the inlet and outlet pipes.
2. Pipe insulation for the specified noncirculating service hot water system is required for all piping in the following categories:a)
the first 8 ft of outlet piping from any constant -temperature, noncirculating storage systemb) the inlet piping between the storage
tank and a heat trap in a noncirculating storage systemPipe insulation must be at least 1/2 in. and have a conductivity no >0.28
Btu4n/(h-ft2-degrees F).
3. Service water heating equipment used solely for heating potable water, pool heaters, and hot water storage tanks must meet the
following miniumum efficiency: Electric Water Heater efficiency — 0.88 EF, 241 SL, Btu/h (if > 12 kW)
Generic Requirements: Must be met by all systems to which the requirement is applicable:
1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals
or an approved equivalent calculation procedure.
2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment
providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as
possible, within available equipment options.
- Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby
equipment must be automatically controlled to be off when the primary equipment and/or system Is operating.
- Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they
are provided with controls to sequence operation of the units as the load increases or decreases.
3. Each heating or cooling system serving a single zone must have its own temperature control device.
4. Each humidification system must have its own humidity control device.
5. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a) capable
of setting back temperature to 55 degrees F during heating and setting up to 85 degrees F during coolingb) capable of automatically
setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour
occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10 hours without power.
- Exception: A setback or shutoff control is not required on thermostats that control systems serving areas that operate
continuously.
- Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or less.
6. Outdoor -air supply systems with design airflow rates >3,000 cfm of outdoor air and all exhaust systems must have dampers that are
automatically closed while the equipment is not operating.
7. The system must supply outside ventilation air as required by Chapter 4 of the International Mechanical Code. If the ventilation
system is designed to supply outdoor -air quantities exceeding minimum required levels, the system must be capable of reducing
outdoor -air flow to the minimum required levels.
8. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces
(spaces neither heated nor cooled) must be insulated with a minimum of R-5. Unconditioned spaces include attics, crawl spaces,
unheated basements, and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of
R-8 when located outside the building.c) When ducts are located within exterior components (e.g., floors or roofs), minimum R-8
insulation is required only between the duct and the building exterior.
RIVER RIDGE CLUBHOUSE Page 9 of 10
- Exception: Duct insulation is not required on ducts located within equipment.
- Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the duct or
plenum does not exceed 15 degrees F.
All joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments; mechanical
fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and
labeled in accordance with UL 181A or UL 181 B.
- Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than
2 inches w.g. pressure classification.
10. Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution
equipment, including multiple -zone terminal units.
11. All pipes serving space -conditioning systems must be insulated as follows: Hot water piping for heating systems: 1 in. for pipes
—1 1/2-in. nominal diameter 2 in. for pipes >1 1/2-in. nominal diameter. Chilled water, refrigerant, and brine piping systems: 1 in.
insulation for pipes —I 1/2-in. nominal diameter 1 1/2 in. insulation for pipes >1 1f2-in. nominal diameter. Steam piping: 1 112 in.
insulation for pipes —1 1/24n. nominal diameter 3 in. insulation for pipes >1 1/2-in. nominal diameter.
- Exception: Pipe insulation is not required for factory -installed piping within HVAC equipment.
- Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55
degrees F and 105 degrees F.
Exception: Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of
fossil fuels or electric power.
- Exception: Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the control
valve and HVAC coil.
12. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a)
equipment capacity (input and output) and required maintenance actionsb) equipment operation and maintenance manualsc) HVAC
system control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions;
desired or field -determined set points must be permanently recorded on control drawings, at control devices, or, for digital control
systems, in programming commented) complete narrative of how each system is intended to operate.
13. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mixing box) must have its own balancing device.
Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices, and supply air diffusers.
14. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance Energy
Conservation Act and the Energy Policy Act of 1992, which meet or exceed ASHRAE 90.1 Code. New service water heating
equipment can be assumed to meet these requirements.
15. Water -heating equipment must be provided with controls that allow the user to set the water temperature to 110 degrees F for
dwelling units and 90 degrees F for other occupancies. Controls must limit output temperatures of lavatories in public facility
restrooms to 110 degrees F.
16. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal
building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and
exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces
served are not in use. Exceptions: - Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height
above grade. - Ventilation systems serving unconditioned spaces.
RIVER RIDGE CLUBHOUSE Page 10 of 10
(10/31/2007) Kim Wolfe - Re: Calling for CO for 1000 Spring Loop Bldg H
Page 1
From: Paul Schoenfeld
To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;...
Date: 10/31/2007 9:09 AM
Subject: Re: Calling for CO for 1000 Spring Loop Bldg H
ALL OK.
PAUL
>>> Amber Carter 10/26/2007 2:44 PM >>>
River Ridge Townhomes
Contact Jennifer w/ Oakwood @ 690-1504
They have said that everything is ready, and there are already people living in some of these units.
Thanks!
(10/30/2007) Kim Wolfe - Re: Calling for C.O. for 1000 Spring Loop (Clubhouse) Page 1
From: Paul Schoenfeld
To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;...
Date: 9/28/2007 4:09 PM
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
NO FOR CO.
Fire hydrant lead valve covered and Fire hydrant can't be accessed because of landscape planting. Planting closet is a
minumn of 3 feet.
Paul
>>> Amber Carter 9/28/2007 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Ofczarzak @ 412-2320
(10/30/2007) Kim Wolfe - Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
Page 1
From: James Boykin
To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;...
Date: 10/4/2007 2:41 PM
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
Environmental Services has received the backflow test report for the clubhouse's irrigation. Okay for a TEMPORARY CO
until they finish out the plumbing for the pool, hot tub, and fountain.
James Boykin
Environmental Technician
Water Services Department
979-764-6312
May the most you wish for be the least you get.
>>> Amber Carter 9/28/2007 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Ofczarzak @ 412-2320
(10/30/2007) Kim Wolfe - Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
Page 1
From:
Jerry Duffey
To:
Amber Carter
Date:
9/28/2007 1:22 PM
Subject:
Re: Calling for C.O.
for 1000 Spring Loop (Clubhouse)
CC: Benjamin McCarty; Chris Haver; Eric Dotson; Eric Hurt; Gina Southerl...
Needs Knox Switch for the front entrance ............ so NO
>>> Amber Carter 09/28/07 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Ofczarzak @ 412-2320
(10/30/2007) Kim Wolfe - Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
Page 1
From: James Boykin
To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;...
Date: 10/1/2007 3:29 PM
Subject: Re: Calling for C.O. for 1000 Spring Loop (Clubhouse)
NO for CO. Environmental Services requires the original backflow test report for the irrigation system (Ser# ADC79). Also,
we wi:l need to inspect the plumbing for the pool, hot tub, and fountain for proper backflow protection. After we receive
the test report for the irrigation, we would be okay with issuing a TEMPORARY CO until they finish the pool's plumbing
and install and test the proper backflow devices.
James Boykin
Environmental Technician
Water Services Department
979-764-6312
May the most you wish for be the least you get.
>>> Amber Carter 9/28/2007 1:19 PM >>>
River Ridge Townhomes
Any issues?
BP # 07-646
Contact Alton Ofczarzak @ 412-2320