HomeMy WebLinkAboutRES2007-00635 136 WALCOURT LOOP BUILDING PERMITPREPARED 5/30/07, 8:02:22 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/30/07
------------------------------------------------------------------------------------------------
ADDRESS . : 136 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9
CONTRACTOR CHARLES THOMAS HOMES, INC PHONE (979) 696-4384
OWNER EDELWEISS GARTEN VENTURE PHONE
PARCEL 244030-0927-0190
APPL NUMBER: 07-00000635 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/28/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
3/28/07 AP March 28, 2007 9:02:11 AM glsouth.
late afternoon
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 4/25/07 OC BLDG, FRAMING TIME: 17:00
C� 4/25/07 AP April 23, 2007 8:56:22 AM kwolfe.
B130 01 4/26/07 BH BLDG, INSULATION TIME: 17:00
4/26/07 AP April 26, 2007 12:33:49 PM ncochran.
April 26, 2007 12:34:05 PM ncochran.
OK for good cents
B125 01 5/30/0 BI BLDG, FINAL TIME: 17:00
May 30, 2007 8:01:27 AM glsouth.
ti
----------'---------------------------- COMMENTS AND NOTES----------------------------
IUD
Date: 5/30/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 635
Address: 136 WALCOURT LOOP
Insp.
Type
Inspection Type Code
Insp.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
April 26, 2007 12:34:05 PM ncochran.
B130
BLDG, INSULATION
IC
OK for good cents
E150
ELEC, FINAL
IC
05/24/2007 02:13 PM RH PDA
E150
ELEC, FINAL
IC
Need to connect ground wire to meter can and ck operation
E150
ELEC, FINAL
IC
of closet light in front bedroom.
Page 1
Nicole Cochran -Insulation re uest inspection result, 136 Walcourt Loop, #07-635 Page 1 #
v
From: Brian Henry
To: Southerland, Gina
Date: 4/26/2007 10:57 am
Subject: Insulation request inspection result, 136 Walcourt Loop, #07-635
CC: Cochran, Nicole; Wolfe, Kim
Print for File
Inspected Insulation, 136 Walcourt Loop, #07-635, Thomas Homes, 4-26-07
Inspection result: nspected OK for Good Cents
Notes:
Attach master bath exhaust fan.
WF0879625 / 001 City of College Station PAGE 1
REQ. DATE: 03/08/07 03/08/07 15:01:12
LOCATION: 136 WALCOURT LOOP LOC ID: 203560
REQUESTOR: CHARLES THOMAS HOMES, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/08/07 SCHED COMPLETION: 03/08/07
********************************************************************************
JOB ORDER RESULT COW4ENTS ��
WFO879420 / 001 City of College:Ss:ation PAGE 1
REQ. DATE: 03/08/07 03/08/07 9:45:54
LOCATION: 136 WALCOURT LOOP LOC ID: 203560
REQUESTOR: CHARLES THOMAS HOMES, INC ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/08/07 SCHED COMPLETION: 03/08/07
********************************************************************************
JOB ORDER RESULT CONIlKENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
6/05/07
244030-0927-0190
136 WALCOURT LOOP
COLLEGE STATION TX 77845
EDELWEISS GARTENS PH 9
EDELWEISS GARTENS #9, BLOCK 27
LOT 19
SINGLE FAMILY RESIDENTIAL
EDELWEISS GARTEN VENTURE
Contractor . . . . . . CHARLES THOMAS HOMES, INC
979 696-4384
Application number 07-00000635 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
Aola�w�
...... - jBuildin IOfficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BU,ZLDIDf_3 PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------- -----------------------------------------
Application Number .
. . . . 07-00000635 Date 3/08/07
Property Address . .
. . . . 136 WALCOURT LOOP
Property ID:
244030-0927-0190
R #:
R303262
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . EDELWEISS GARTENS PH 9
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 105000
Owner
Contractor
------------------------ ------------------------
EDELWEISS GARTEN VENTURE CHARLES THOMAS HOMES, INC
311 CECILIA LOOP
P.O. BOX 10106
COLLEGE STATION
TX 778456310 COLLEGE STATION TX 77842
(979) 696-4384
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1504.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
475.00 Plan Check Fee .00
Issue Date . . . .
3/08/07 Valuation . . . . 105000
Expiration Date . .
9/04/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
5.00 3.0000
THOU BLDG, VAL 100001-500000 15.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROJUGH-FRAMED SIZE 22"
----------------------- --------------------
BUILDING D PRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00000635 Date 3/08/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
--------------------------------------------- ----------
BUILDING DEPT /REPRESENTATIVE : ,- -
BUILDING PERMIT
CITY Off' COftEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000635 Date 3/08/07
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
BUILDING
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00000635 Date
3/08/07
----------------------------------------------------------------------------
Special Notes and Comments
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Narrow Wall Bracing Fully Sheathed with interior anchors and
bracing for front door area in garage.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 475.00 475.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1225.00 1225.00 .00
.00
BUILDING D
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00000636 Date
3/08/07
Property Address . . . . . .
136 WALCOURT LOOP
Property ID:
244030-0927-0190
R #:
R303262
Application type description
TEMP POLE
Subdivision Name . . . . . .
EDELWEISS GARTENS PH 9
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
CHARLES THOMAS HOMES,
INC
311 CECILIA LOOP
P.O. BOX 10106
COLLEGE STATION TX 778456310
COLLEGE STATION
TX 77842
(979) 696-4384
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . KW
Permit Fee . . . . 20.00
Issue Date . . . . 3/08/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
--------------------------------�-----------
-------- BUILDING- - - - - - - -- DE -A REtRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.
Planning d' Develop nmt Semices
ADDRESS/LOCATION: � 3 L[CQakT_
Laop
LOT S LiLOCK JUBDIVISION ALOF S 16
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER
CONTRACTOR ADDRESS:
ELECTRICIAN:K_c=-%k/
HVAC: aom okr
CHARLES THOMAS HOMES
P.O. BOX 10106
nni I FrF STATI(_1N TY 77A.
2 For ONke Use Only
DATE TRCC REG
APPLICATION #
TEMP POLE #�
SE /PH
PHONE:
INC. PHONE: DD
—&V—
-i r- . CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION VING SHELL ONLY
DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
- I / 1 TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: �)
HOMEOWNER ASSOCIATION/AR�HITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: IPA
J—� TEXAS ACCESS IBILIT STANDARD (TAS) PRO CT REGISTRATION# EABPRJ
415 - VALUATION: $ ��, ��� V TOTAL AREA: 19D HEATED AREA: 150
(Cost of Labor and Materials)
dPUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
D\ it
SEWER TAP:
'� 4 4
DD WATER TAP: S
IZE
OTHER TAP:
f (5 SIZE
1dTEMP POLE
GARAGE TYPE: SINGLE
ATTACHE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE TRIPLE
DETACHED [ CfQPOR
i,
EJ
SIGNATURE OF APPLICANT: -
*If proposed work involves new commercial construc Ion or facad Improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only '
Plans Examiner Zoning Official Fire Marshall
W% 14 Co ments: for NO
Y f) "C-4- j and
c6I.A-)
Energy Code Compliance Information
0
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
11
I
y
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
BUILDING ADDRESS: 36 �N
I. Foundation Requirements
N
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
NVOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex90K
1. One -hour rated extending to roof deck
WJQOK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. StairwayRequirements
OK
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
077
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NAkW
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/'r
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
ej
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NAI
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAIPW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
( A -
"APPROVED PLANS PER IRC SECTION R106.3.1."
J/1 a �__ — 3-7,-D`)
PMffS EXAMINER DATE
SATE Pla�l �a�,
19 �1�. 27
EaEl��.�ss caoirttAL'— vv)59
136 W.?llcoup'T Loaf
E� oo
`�V�ICAIRa Lov�
CO
CHARLES THOMAS HOMES, INC.
P.O. BOX 10106
COLLEGE STATION, TX 77842
earl ISO - K
scakt, ; 11' y
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: College Station Building Permits
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/06/07
DATE OF PLANS: 03/07/2007
PROJECT INFORMATION:
136 Walcourt Loop - Edlws Grtns-Phs 9
COMPANY INFORMATION:
Charles Thomas Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 752
Your Home = 532
29.3% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
Door 1: Solid
Door 2: Solid
Door 3: Glass
Slab 1: Unheated, 0.0' insul.
Air Conditioner 1: Electric Central Air, 14 SEER
Furnace 1: Forced Hot Air, 80 AFUE
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
1504
0.0 30.0
47
1696
13.4 0.0
119
167
0.640
107
20
0.130
3
17
0.130
2
17
0.440
7
237
0.0
247
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed tom t th 2000 IECC requiremen=NECcheck 3.2 Release lb.
Builder/Designel Dateorl
CHARLES THOMAS HOMES, INC.
P.O. BOX 10106
COLLEGE STATION, TX 77842