Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-00604 905 OLYMPIC CT BUILDING PERMIT
WF0879220 / 001 City of Collet; Station PAGE 1 REQ. DATE: 03/07/07 03/07/07 14:42:07 LOCATION: 905 OLYMPIC CT LOC ID: 204638 REQUESTOR: CROWLEY CONSTRUCTION ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/07/07 SCHED COMPLETION: 03/07/07 ******************************************************************************** JOB ORDER RESULT COMMENTS I City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 11/14/07 Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning Owner . . . . . . . . . Contractor . . . . . . 497900-0947-0060 905 OLYMPIC CT COLLEGE STATION TX 77845 PEBBLE CREEK PHASE 9-E BLOCK 47 LOT 6 SINGLE FAMILY RESIDENTIAL CROWLEY CONSTRUCTION 979 777-0285 Application number 07-00000604 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved bial VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 11/12/07, 11:51:26 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/12/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 905 OLYMPIC CT SUBDIV: CONTRACTOR CROWLEY CONSTRUCTION PHONE (979) 777-0285 OWNER . . PHONE PARCEL . . 497900-0947-0060 APPL NUMBER: 07-00000604 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/16/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/16/07 AP April 16, 2007 11:10:47 AM kwolfe. late afternoon Strings On Setbacks O.K. Slab Ground Installed B115 01 6/15/07 JGM BLDG, FRAMING TIME: 17:00 6/15/07 AE June 13, 2007 8:31:42 AM acarter. 06/15/2007 10:42 AM JGM PDA need to draftstop return air chase B130 01 6/26/07 OC BLDG, INSULATION TIME: 17:00 6/26/07 AP June 26, 2007 10:27:10 AM acarter. B125 01 11 12/s077J BLDG, FINAL TIME: 17:00 itIst / � � November 12, 2007 9:30:11 AM acarter. -------------------------------------- COMMENTS AND NOTES -------------------------------------- Cif / _y�(�/L/- '�1.0Y, �J ins .lie 8 Date: 11 /13/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 604 Address: 905 OLYMPIC CT Insp. Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed 6115 BLDG, FRAMING IC 06/15/2007 10:42 AM JGM PDA B115 BLDG, FRAMING IC need to draftstop return air chase E150 ELEC, FINAL IC 10/19/2007 03:30 PM RH PDA E150 ELEC, FINAL IC By building final install cover on junction box in attic. E150 ELEC, FINAL IC Secure and protect wire entering upper water heater E150 ELEC, FINAL IC cabinet. P105 PLBG, TOP OUT IC 06/08/2007 10:52 AM JGM PDA P105 PLBG, TOP OUT IC need to protect water and gas line in water heater cabinet P125 PLBG, FINAL IC 11/09/2007 11:21 AM JGM PDA P125 PLBG, FINAL IC need to protect water and gas line entering water heater P125 PLBG, FINAL IC cabinet need to turn down tmp drain line, need plug in P125 PLBG, FINAL IC outside gas stop P125 PLBG, FINAL IC November 13, 2007 11:43:22 AM glsouth. Page 1 WF0882796 / 001 City of College Station PAGE 1 REQ. DATE: 03/22/07 03/22/07 10:00:36 LOCATION: 905 OLYMPIC CT LOC ID: 204638 REQUESTOR: CROWLEY CONSTRUCTION ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/22/07 SCHED COMPLETION: 03/22/07 ************************************************** ** ************************* JOB ORDER RESULT COM4EbTI'S � Q d Uj r mf- rr0 P U30 ( m 7� rn LO m m Z KIRBY L. FLEMING, Designer P.O. Box 241 CAUSE , TEXAS 77857 979.279.3577 157.g4' 7'-6" buildinq Iine J L.O W p_. 140.74' Kirby I. Fleming ©2001 THIS OFFICE ASSUMES NO LIABILITY FOR ERRORS OR OMISSIONS ON THESE PLANS. ALL INFORMATION, MUST BE CONFIRMED PRIOR TO COMMENCEMENT OF CONSTRUCTION. THESE DRAWINGS HAVE BEEN DEVELOPED AND ISSUED WITHOUT KNOWLEDGE OF GEOGRAPHICAL LOCATION. i THERE FORE, SUPPLEMENTAL TO THESE DOCUMENTS IS THE OWNER AND BUILDERS RESPONSIBILITY FOR FOLLOWING MATERIAL AND MANUFACTURERS INSTRUCTIONS, AND USING RECOGNIZED STANDARDS FOR EACH TRADE, AS WELL AS COMPLIANCE IN FULL WITH ALL GOVERNING CODE REQUIREMENTS FOR THE GEOGRAPHIC AREA IN WHICH THIS HOME IS TO BE CONSTRUCTED. F F 0 0 IJ 0 -j cn { Amber Carter - Re, Calling for CO for 905 Olympic Ct From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; Date: 11/14/2007 2:28 pm Subject: Re: Calling for CO for 905 Olympic Ct Contacted Rob Crowley at 777-0285 Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Mitchell Carson 11/14/2007 2:24 pm >>> Sewer clean out box and lid are missing.needs to be replaced. Placed a green flag where the clean out is at. Mitch >>> Amber Carter 11/13/07 12:26 PM >>> by 07-604 Any issues? Ifs To Whom It May Concern: Crowley Construction, INC will be changing electricians on 905 Olympic Court. The new electrician will be Hilco Electric. Thanks ert �ey President l'd 9Z9E0696M NOIlOnbiSN00 A31M0bO e9£: l l LO L 6 100 t BU?;LDING PERMIT CITY COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)'164-3570 _FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00000604 Date 3/07/07 Property Address . . . . . . 905 OLYMPIC CT Property ID: 497900-0947-0060 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 260000 Owner Contractor ------------------------ ------------------------ CROWLEY CONSTRUCTION 2033 RAVENSTONE LOOP COLLEGE STATION TX 77845 (979) 777-0285 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 3000.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 426.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 940.00 Plan Check Fee .00 Issue Date . . . . 3/07/07 Valuation . . . . 260000 Expiration Date . . 9/03/07 Qty Unit Charge Per Extension BASE FEE 460.00 160.00 3.0000 THOU BLDG, VAL 100001-500000 480.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) . PROVIDE ATTIC ACCESS OPENING (MINIMUM SIZE 22" aUGFRAMED ------------------------------------� -- BUILDING DEPT REPRESENTATIVE: 01* --------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 07-00000604 Date 3/07/07 ---------------------------------------------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, ---------------------------------------------- I------z --�- /-.---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: / / BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 07-00000604 Page 3 Date 3/07/07 Special Notes and Comments STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA ---------------------------------------------- ------ --- - -- -_---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLIEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00000604 Date 3/07/07 ---------------------------------------------------------------------------- Special Notes and Comments PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Foundation to include piers per plans. Narrow Wall Bracing Fully Sheathed with APA Framing in locations indicated on the plans. Modified Breakfast Area by reducing window size and possibly moving closer to door to get 27" minimum in corner. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 940.00 940.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1690.00 1690.00 .00 .00 - TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00000605 905 OLYMPIC CT 497900-0947-0060 TEMP POLE Date 3/07/07 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ CROWLEY CONSTRUCTION 2033 RAVENSTONE LOOP COLLEGE STATION TX 77845 (979) 777-0285 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date . . . . 3/07/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------ ----- --- --- -=--------- BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION, FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (*Or" (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Planning d Drudopment Stmicei �r Ole Use nly� DATE. 3 `/ TRCC REG� APPLICATION # to-(, O I TEMP POLE # ADDRESS/LOCATION:_ `�T05 C1 ,y LOT BLOCK -4 __7____'SUBDIVISION p �Q V —SEC/PH_� BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: rir . 6'4 PHONE: CI79 CONTRACTOR ADDRESS: ELECTRICIAN: �� �� PLUMBER: CJ\� HVAC:GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: 1�owtie Fes„ I���ti PROPOSED USE: HOMEOWNER ASSOCIATION/AR IT TUAL OR DESIGN REVIEW COMMITTEE APPROVAL: `IIcS TEXAS ACCESSIBILITY STANDARD AS) PROJECT REGISTRATION# EABPRJ 4 VALUATION: $ 2�61 oaa TOTAL AREA: HEATED AREA: 3QC�6 1 �I (Cost of Labor and Materials) ❑ PUBLIC SEWER NUMBER OF BEDROOMS: L� SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: q /� INTERIOR WALL TYPE: ` SIZE WATER TAP: 3 I EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: ^4p SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE DOUBLE E' TRIPLE a ATTACHED DETACHED F] CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new com construction o ca i ovements/re�s to an existing commercial property, building elevations are required. Official Use Only 6- 3 , � __"0 7 OWPlans Examiner Zoning Official QoNments: �L juj tj /"� E or NO Fire Marshall NC_ AA4-c f 9- f �aws } Energy Cqde Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating 137 14O / r PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# O 7_ 6 O V I DATE: BUILDING ADDRESS: o S /Vrh P I'C-. I. Foundation Requirements - - N A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species O NA/ B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck E. Header sizes indicated on plans K F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, urlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK VA_ A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow ed e C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Re uirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N A(T 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location FA PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 30 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed "APPROVED PLANS PER IRC SECTION R106.3.1." Y ` PLANS EXAMINER �.�'� SATE Permit Number RMAet* COMPUSnee Cerdflmte Checked Bra 2MO JECC RESdmk Sofwm Version 3.6 Release 2 Dens "among: C:\Ptngtam Files\Chete MES&m*\CrowIcy_PEBBLB CREEK LOT6.mk PROJECT TITLE: Spaailative Residence CITY: College Station STATE: Tereus HDD: 1798 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.16 DATE: 02/26/07 DATE OF PLANS: 02.22.07 PROJECT DESCRIPTION: Lot 6 Hledc 47 Phase 94%� 15 Pebble Creek DESIGNER/CONTRACTOR: Cmwtey Coeeaucpon COMPLIANCE: Peas Maximum UA . 1297 Your Home UA - 970 25.2% Better Than Code (UA) Maximum SHOO - 0.40 Your SHOC - 0.35 CIQ. 1: !at e:lg.: Flat Ceiling or Sdaw Truss Wall 1: 2 a 4 wells: Wood Fiame, 16" o.c. Window 1 SH: Viiryl FrancDoable Pane with Low-E SHGC: 0.34 Window 2 FXD.: Vinyl Famer.Double Paine with Low-E SHOO: 0.33 Dam l: Solid Door 2: (hues SHGC: 0.40 Flow 1: Slab-Oedhsdr.Unhaiiad GnM Clang Ain or Cavity cont. or Door P.00ma,tt; 1L. &Yiijue 1L-Ell�ipc NA 3025 30.0 0.0 106 3305 13.0 0.0 225 264 0.650 172 173 0.520 90 24 0.400 to % 0.400 38 316 0.0 329 Insulation depth: 0.9 Funme 1: Fottxd Hot Air, 80 AFUE Air CoaditioaQ 1; Ucchic CG*W Air, 14 SEER COMPLIANCE STATEMENT: The proposed building design dsaibcd hen• is consistent with the building plans, spwwcedoos, sud other atcasalons submitted with the Pffmit spphcdwo. The poposed building ha be daigocd to mast the 2000 IECC Nquimnmts in RFSdw& Version 3.6 Release 2 (&maty m h�Cd+aah sad to comply with tho odetory rogttinemeans listed in tho RESoi�dt htspecdon Cheddist. BuildQlbedgeia Dace