INSPECTION TICKET PAGE 6
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 10/17/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 1105 ROYAL ADELADE
DR SUBDIV: PEBBLE CREEK
CONTRACTOR
D W S DEVELOPMENT
PHONE (979) 779-7209
OWNER
FOSTER, JAMES H & ALICE A PHONE
PARCEL
497900-0039-0010
APPL NUMBER: 07-00000602 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
3/28/07 JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
3/29/07 AP
March 28, 2007 11:42:27 AM glsouth.
early morning
Strings On Setbacks O.K.
Slab Ground Installed
1115 01
6/13/07 JGM
BLDG, FRAMING TIME: 17:00
6/14/07 DP
June 11, 2007 8:36:12 AM acarter.
June 12, 2007 8:12:21 AM acarter.
06/14/2007 08:17 AM JGM PDA
need to sheetrock and fireblock fireplace chase
B115 02
6/14/07 JGM
BLDG, FRAMING TIME: 17:00
6/14/07 AP
June 14, 2007 1:53:38 PM acarter.
B130 01
6/15/07 JGM
BLDG, INSULATION TIME: 17:00
6/15/07 AP
June 15, 2007 10:47:23 AM glsouth.
B125 01
10/17/ 7 BI
BLDG, FINAL TIME: 17:00
p .�/�{
October 17, 2007 10:11:25 AM acarter.
----------------------------------
COMMENTS AND NOTES ---------------------------
0
Date- 10/17/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 602
Address: 1105 ROYAL ADELADE DR
Insp.
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/14/2007 08:17 AM JGM PDA
B115
BLDG, FRAMING
IC
need to sheetrock and fireblock fireplace chase
E150
ELEC, FINAL
IC
10/11/2007 11:38 AM JGM PDA
E150
ELEC, FINAL
IC
need to replace painted smoke detectors, need switches
E150
ELEC, FINAL
IC
closets; need smoke detctors upstairs in finished room
M100
MECH, ROUGH IN
IC
06/14/2007 08:15 AM JGM PDA
M100
MECH, ROUGH IN
IC
dryer vent too long
Page 1
WF0879629 / 001 City of College Station
PAGE 1
REQ. DATE: 03/08/07 03/08/07 15:03:08
LOCATION: 1105 ROYAL ADELADE DR LOC ID: 187270
REQUESTOR: D W S DEVELOPMENT ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/08/07 SCHED COMPLETION: 03/08/07
********************************************************************************
JOB ORDER RESULT COMAENTS �� f bE
WF0906667 / 001 City of College Station
PAGE 1
REQ. DATE: 05/22/07 05/22/07 15:41:44
LOCATION: 1105 ROYAL ADELADE DR LOC ID: 187270
REQUESTOR: D W S DEVELOPMENT ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 05/22/07 SCHED COMPLETION: 05/22/07
********************************************************************************
JOB ORDER RESULT COMIENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type
Occupancy type .
Flood Zone . . . .
10/23/07
497900-0039-0010
1105 ROYAL ADELADE DR
COLLEGE STATION TX 77845
PEBBLE CREEK
PEBBLE CREEK #7A, BLOCK 39, LO
T 1
SINGLE FAMILY RESIDENTIAL
FOSTER, JAMES H & ALICE A
D W S DEVELOPMENT
979 779-7209
07-00000602 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
14(
Approved r4W
13u' 1)ding OTTicial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
(10/19/2007) Gina Southerland - Re: Calling for C.O. @ 1105 Royal Adelaide Dr. Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 10/18/2007 2:55 PM
Subject: Re: Calling for C.O. @ 1105 Royal Adelaide Dr.
Contacted Benji with DWS at 412-1387
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 10/18/2007 11:07 am >>>
Water ok.
Sewer buried no box or lid flagged.
Paul
>>> Gina Southerland 10/17/2007 12:33 PM >>>
BP# 07-602
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
BUTT_L� DINI,G PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
'COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 07-00000602 Date 3/08/07
Property Address . .
. . . . 1105 ROYAL ADELADE DR
Property ID:
497900-0039-0010
R #:
R105201
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 266772
Owner
Contractor
------------------------
FOSTER, JAMES H& ALICE
------------------------
A D W S DEVELOPMENT
P 0 BOX 8359
111 FM 2818
HORSESHOE BAY
TX 78657 BRYAN TX 77803
(979) 779-7209
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE STONE
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 4042.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.50
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 419.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
961.00 Plan Check Fee .00
Issue Date . . . .
3/08/07 Valuation . . . . 266772
Expiration Date . .
9/04/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
167.00 3.0000
THOU BLDG, VAL 100001-500000 501.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUMROUGH-FRAMEDSIZE 22"
w
BUILDING
APPLICANT:
BUILDING PERMIT
r'
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 07-00000602
Page 2
Date 3/08/07
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
This house site plan shows 32' circle drive, Ken Fogle
approved a reduced 28' total.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
This foundation Plan is Engineered.
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
BUILDING R ESENTATIVE: -1,0:- - 9
APPLICANT:
BUILDIWG PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000602 Date 3/08/07
----------------------------------------------------------------------------
Special Notes and Comments
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
--------------------------------------------- ------ ---- ------------------
BUILDING� DEPT ESENTATIVE: •
APPLICANT:
BUILDIPIG PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000602 Date
3/08/07
----------------------------------------------------------------------------
Special Notes and Comments
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Stairs show less than 6" min. tread width on winders, must
meet 6" minimum.
Contact Pete Garcia for Backflow requirements for fountain
Q
764-3663.
Narrow Wall Bracing Fully Sheathed with Engineered Panels
per plans and APA Framing at Garage and Great Room areas.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 961.00 961.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1711.00 1711.00 .00
.00
--------------------------------------------- -------'----------
BUILDING DEPT TATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . .
BUILDI:
APPLIC.
07-00000602
Page 5
Date 3/08/07
TEMPORARY,POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . . 07-00000603 Date
3/08/07
Property Address
. . . . . . 1105 ROYAL ADELADE DR
Property ID:
497900-0039-0010
R #:
R105201
Application type description
TEMP POLE
Subdivision Name
. . . . . . PEBBLE CREEK
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 0
Owner
Contractor
------------------------
FOSTER, JAMES H&
------------------------
ALICE A D W S DEVELOPMENT
P 0 BOX 8359
111 FM 2818
HORSESHOE BAY
TX 78657 BRYAN
TX 77803
(979) 779-7209
---------------------
Structure Information 000 000 -----------
-----------
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
----------------------------------------------------------------------------
. . . . . RESIDENTIAL-SFR/DUPLEX
Permit . . . . .
. TEMP POLE PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/08/07 Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . . TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00 20.00 .00
.00
Other Fee Total
45.00 45.00 .00
.00
Grand Total
65.00 65.00 .00
.00
-------------------
BUILDING _U
APPLICANT:
A - :;k
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(*Or" (979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning d Development Stmices l �7
ADDRESS/LOCATION:
For Office Us Only
5�
b3(�
DATE. TRCCbRE RE/G,, �%
APPLICATION # b -L
TEMP POLE # v� - lrr lSIQ v%�D 1�)
N)
LOT C( BLOCK ✓ SUBDIVISION ����Z �-��� ✓ SEC/PH_XII`_
BUSINESS/OWNER NAME: G/S mot/ PHONE: / 7� �,Z2_ '1,�� �
CONTRACTOR/HOMEOWNER:PHONE:
CONTRACTOR ADDRESS: �y ,(�ofc �J o $ �� ✓u�
ELECTRICIAN PLUMBER:
HVAC: �l�T l-����.t, Via`:, S GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVI G SHELL ONLY
DEMOLITION (Asbestos Survey W CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
�r TENT/CANOPY
DESCRIPTION OF WORK: kz �C` �'.._ 1
PROPOSED USE:
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ //v / 1 -
VALUATION: $ _Z-4�, Cr- TOTAL AREA: ,�% ? T HEATED AREA: 9-y 7-
(Cost of Labor
and Materials)
/
UBLIC SEWER L( (`-' 1771 �Vll_
SEPTIC/TREATMENT SYSTEM
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
SEWER TAP:
INTERIOR WALL
V
TYPE:
ppSIZE
Iff WATER TAP: 5A7/
EXTERIOR WALL TYPE:
�72�-. C_
/ SIZE
❑ OTHER TAP:
FOUNDATION TYPE:
x 2 /s f
SIZE
TEMP POLE
ROOF TYPE:
�j GARAGE TYPE: SINGLE a
DOUBLE TRIPLE
'`�
ATTACHED
�1
TACHED CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new comme
construction or facade improvements/renovations
to an existing
commercial property, building elevations are required.
Official Use Only
F1 P_ Plans Examiner
�C� I
Zoning Official
,2c Le QMVew i6e wir,(-e. I�s?z� ents:
✓Ne S a8'�v1aX f'cI(. /Y /ruClksiA (ter NO
Fire Marshall
5b w �
� .0
- C ja4 Pam, G,Vcr a 44, &_ j V%, 4L A440-� ?/ 91,N - 36( 3
Energy Code Compliance Information
% Glazing of exterior walls
l'�
Insulation R value of exterior walls
j
Insulation R value of areas
ceiling g 1 (flat )
"
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
d s"z ✓
R value of ductwork
A/C SEER Rating
✓
a
6
E NFRG'r CCD SF C CAT CI 5
GROSS WALL SO. FT.: 3/ 473.541 PERCENTAGE OF FENESTRATION
FENESTRATION SO. FT.: 760.40 TO WALL RATIO: 21.G%
IN ACCORDANCE WITH CHAPTER 5 OF THE INTERNATIONAL ENERGY
CONSERVATION CODE, AND BASED ON THE PRESCRIPTIVE BUILDING
ENVELOPE REQUIREMENTS FOR THE BRYAN/COLLEGE STATION AREA,
THE FOLLOWING SPECIFICATIONS WILL APPLY -
TABLE 502.2.4(G), MAX 25% RATIO
MAXIMUM GLAZING U FACTOR: 0.52
MINIMUM EXTERIOR WALL R-VALUE: R-13
MINIMUM CEILING R-VALUE: R-30
MINIMUM HVAC SEER VALUE: 13 SEER
ENERGY CODE SPECS CALCULATED FOR:
DWS DEVELOPMENT (FOSTER)
DATED: 28FEB07
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
DATE:
PLAN REVIEW/PERMIT NUMBER# Q _ 3 -
Gib 3 07
BUILDING ADDRESS:
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier Emil. Poly min.
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
OK
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
K
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
jbK
ffA
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of —span indicated on plans
L. Attic access location and size indicated on plans
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O. Roof covering
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
IT
A. Stairway Details
NA/
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAT
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 860
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NAVK
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
"APPROVED PLANS PER IRC SECTION R106.3.1."
�0 7
PLANS EXAMINER DATE