HomeMy WebLinkAboutRES2007-00573 902 TURTLE DOVE TRL BUILDING PERMIT(8/10/2007) Gina Southerland - Re: Calling for CO @ 902 Turtle Dove TO Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; fredburris; Gina Southe...
Date: 8/10/2007 9:25 AM
Subject: Re: Calling for CO @ 902 Turtle Dove Trl
Century Classic Homes has been notified.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 8/10/2007 8:30 am >>>
Water buried flagged.
Sewer co box and manhole buried flagged.
Paul
>>> Kim Wolfe 8/9/2007 11:43 AM >>>
any issues?
BP # 07-573
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.00v
PREPARED 8/09/07, 11:35:01 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/09/07
------------------------------------------------------------------------------------------------
ADDRESS . : 902 TURTLE DOVE TRL SUBDIV:
CONTRACTOR CLASSIC CENTURY HOMES PHONE (817) 561-4369
OWNER . . PHONE
PARCEL . . 230100-0209-0020
APPL NUMBER: 07-00000573 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/25/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
4/25/07 AP April 25, 2007 9:03:07 AM glsouth.
04/25/2007 03:04 PM RH PDA
Slab survey submitted, slab ground installed.
B115 01 5/29/07 OC BLDG, FRAMING TIME: 17:00
5/29/07 AE May 25, 2007 9:25:58 AM kwolfe.
05/29/2007 10:47 AM OC PDA
must install fireplace by insulation inspection .
B130 01 6/01/07 JGM BLDG, INSULATION TIME: 17:00
6/01/07 DP May 31, 2007 4:40:55 PM glsouth.
06/01/2007 01:38 PM JGM PDA
need to attach ducts to exhaust fans, need to fix
overstuffed areas, need to replace insulation in areas
that are not 3 1/2" thick, need to display R-value on wall
insulation - ok to brick
B130 02 6/04/07 JGM BLDG, INSULATION TIME: 17:00
6/05/07 DP June 4, 2007 4:31:15 PM glsouth.
Did Not Fix Notes From Previous Inspections
B130 03 6/07/07 OC BLDG, INSULATION TIME: 17:00
6/07/07 DP June 7, 2007 8:00:19 AM kwolfe.
Sheetrock Fireplace Chase, Firestopping
06/07/2007 11:00 AM OC PDA
didn't insulate behind shower.
B130 04 6/08/07 OC BLDG, INSULATION TIME: 17:00
6/08/07 AP June 8, 2007 9:58:24 AM kwolfe.
B125 01 / 7 P BLDG, FINAL TIME: 17:00
7 0� August 9, 2007 11:22:50 AM kwolfe.
-------------------------------------- COMMENTS AND NOTES ------ ---------------------------
Date: 8/9/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 573
Address: 902 TURTLE DOVE TRL
"Sp•
Type
Inspection Type Code
Description
Insp.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
04/25/2007 03:04 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Slab survey submitted, slab ground installed.
13115
BLDG, FRAMING
IC
05/29/2007 10:47 AM OC PDA
B115
BLDG, FRAMING
IC
must install fireplace by insulation inspection .
B130
BLDG, INSULATION
IC
06/01/2007 01:38 PM JGM PDA
B130
BLDG, INSULATION
IC
need to attach ducts to exhaust fans, need to fix
B130
BLDG, INSULATION
IC
overstuffed areas, need to replace insulation in areas
B130
BLDG, INSULATION
IC
that are not 3 1/2" thick, need to display R-value on wall
B130
BLDG, INSULATION
IC
insulation - ok to brick
B130
BLDG, INSULATION
IC
Did Not Fix Notes From Previous Inspections
B130
BLDG, INSULATION
IC
Sheetrock Fireplace Chase, Firestopping
B130
BLDG, INSULATION
IC
06/07/2007 11:00 AM OC PDA
B130
BLDG, INSULATION
IC
didn't insulate behind shower.
M100
MECH, ROUGH IN
IC
05/11/2007 10:21 AM RH PDA
M100
MECH, ROUGH IN
IC
Exhausr fan flex duct exceeds manufacturers limit of 14'.
M110
MECH, FINAL
IC
Lawn Irrigation System Installed
P125
PLBG, FINAL
IC
Lawn Irrigation System Installed
Page 1
WFO882129 / 001 City of College Station PAGE 1
REQ. DATE: 03/20/07 A 03/20/07 14:26:31
LOCATION: 902 TURTLE DOVE TRL LOC ID: 204560
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/411
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/20/07 SCHED COMPLETION: 03/20/07
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . .
Property Address
Subdivision Name
Legal Description
Property Zoning .
Owner . . . . . . .
Contractor
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
8/20/07
230100-0209-0020
902 TURTLE DOVE TRL
COLLEGE STATION TX 77845
DOVE CROSSING PHASE 2
BLK 9 LOT 2
SINGLE FAMILY RESIDENTIAL
CLASSIC CENTURY HOMES
817 561-4369
07-00000573 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
w
Approved . . . . . . .
Bui-MinVOfficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
WF0883974 / 001 City of College Station PAGE 1
A,
REQ. DATE: 03/27/07 03/27/07 11:45:47
LOCATION: 902 TURTLE DOVE TRL LOC ID: 204560
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/27/07 SCHED COMPLETION: 03/27/07
********************************************************************************
JOB ORDER RESULT COM4 TTS
Apr 25 07 01:44p Cch - B/cs 979 690 3823
APR-13-2007 FR1 08:12 Ali P.018/018
SURVEY PLAT
This is to certify that I have, this dote, mode an on the ground survey of the property
located on 902 TURTLE DOVE TRAIL in the City of COLLEGE STATION, Texas, described as
follows:
Lot 2. Block 9. of DOVE CROSSING, an Addition to the City of COLLEGE STATION. BRAZOS
County, Texas, according to the MAP or Plot thereof recorded in VOLUME 7302, PAGE 219,
of the Plot Records of BRAZOS County, Texas.
4
MOM
2. 8=4 or Bearing — subject Plat
3. C.Y. - COMIMUJNC YaNwwr
MWEr. n aw ar STaw wmut
r+n r1 OMM a SLID cT 10 Tw ratLN4111Q
WLL%E 144M PAGE 1.7 V= NOT Arco
CANDU A. MW 7454 /F=13 AND PUMM
rk q
ti
f
11r r.u8 f
VOL 73= ►C. 2N
11-1
). -../mil
0
4 d�Y,miwi�+�F1O0pPY�r�11►� w�C9701 D � M� ��• 7Y�, M� rljgl w�rr Day rMit r rM7e � >�RLI riM NMw4 M� (tom ti F1rf� 11� iY,
4*000d bp No Wwd Y
120k as ofr�,M�W�1_In�Md�wYn �,iw�yLy
i ^M� W 1� asw �Y ��Mw�k vrM �► K rnY Mn�� d14
w Ww1Yii
err
YVilliam P.
%Od+ R.rwi.sr 1w4 SwWw ea ap
j
BUENA TIERRA GROUP
sum"Wo • eortsuUM • >Mur rr
7EULIESS.
SOUTH INDUSMIAL BLw., SU(TE 215 (817) 354-1443 �u� 7>acas 76a4p (817) 354-1451 (F) __...
e
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 5 7 3
DATE: v-7
BUILDING ADDRESS:
0 I U+IC vUe `�a�
I. Foundation Requirements -
NAJW
A.
Concrete minimum fc of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
#JOK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
K
Ir I
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairwa
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAQW
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NAB
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
11
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements - Ordinance 850
NA/VA
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
Subdivision Regulations - Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations - Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
w I A -
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
5 ,�0-1
DATE
APPLICATION FOR BUILDING PERMIT DATO 4Rlin
CITY OF COLLEGE STATION APPLICATION # 01 0 M __3
1101 TEXAS AVENUE -7/4 COLLEGE STATION, TX 77840 TEMP POLE # 0-7-95
Crr), or Ct it I 1,G, 1% STA 110N (979) 764-3570 (079) 764-3496 FAX
Nww��r WWW.CSTX,GOV
ADD RE SSILO CATION:
LOT (-3 -------- SEC/PI-1--2
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS:
ELECTRICIAN: -------- PLUMBER:
HVAC: — --------------- - ----------- - GOOD CENTS (Residential only):
CLASS.OF WORK 0
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION" SWIMMING POOL
Required)
DESCRIPTION OF WORK' DZ
STRUCTURE USE: ------
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSI�1-ILITY ;STANDARD (TA PROJECT REGISTRATION# EABPRJ - -------- j\I/A
VA UATION: $ .1
TOTAL AREA: _�Z(_ HEATED AREA: j
-1 - +
(cost of ail,
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTICITREATMENT SYSTEM NumaFR OF BATHROOMS: 22
it
SEWER TAP: INTERIOR WALL TYPE: L
It
-[�WATER TAP: 3A EXTERIOR WALL TYPE: cK
Si2E
D THER TAP: FOUNDATION TYPE:
C/l� 1 SIZE
TEI
�,4P POLE ROOF TYPE: in
GARAGE TYPE,: SINGLE DOUBLE TRIPLE
ED
ATTActirn DETACHED CARPORT F-]
SIGNATURE OF APPLICANT:
O�S t�
*If proposed work involves new cornmer a on ruction (r facade impr em its/renovations to an existing
re ren Ire
commercial property, bt6ldinq elevations reqUirpd.
Official Use Only
I ,4Mf.V?8nts:
or NO
Plans Examine( Zoning Official
GIP WY 14
Atle
F
r7
Energy Code Coniplian-ceInformativir
0/0 Olazing of exterior Walls
Insulation R- value. of exterior wal Is WTT/
Insulation R value of ceiling I (flat areas)
Insulation P, value of ceiling 2 (yaulted areas/no attic) �TT
Glazhig 81,:TGC
Glazing U-Factor
R value of ductwork �' ../
A/C SEER Rating
55.151'
10' P.U.E
------------o----
00
N
ONE STORY
SINGLE FAMIL
BRICK RESIDENCEo
PLAN # 1784 N
40'-0"
7'-6"
T-7 13/16"
I9' CONC.
DRIVEWAY
0
kn
N
- -
- - - - -
- - - -
5' P.U.E
55.151'
902 TURTLE DOVE TR
25' BL
LOT 2, BLOCK 9
PHASE 2
DOVE CROSSING SUBDIVISION
COLLEGE STATION, BRAZOS CO.
TX
ngineering, LLC
401 S. CLAY STREET, ENNIS, TX 75119
February 19, 2007
Classic Century Homes
5001 Hwy. 287 South
Arlington, TX 76017
The following post -tensioned foundation plans are herein authorized for construction at the address and legal
description shown below.
Lot Bilk Subdivision Address c1tv County State
2 9 Dove Crossing 902 Turtle Dove Tr. College Station Brazos TX
A site specific soils report was not provided. The foundation has been designed based on the following soils
conditions.
Soils Laboratory
Brazos County USDA Soils Survey
Allowable
Bearing Pressure P.I.
1500 psf 52
The foundation design is in accordance with the applicable provisions of the International Building Code
2000/2003 Edition, the International Residential Code 2000/2003 Edition, the Design and Construction of Post -
Tensioned Slabs -on -Ground, Second Edition, 1996 by the Post -Tensioned Institute, applicable provisions of the
Building Research Advisory Board (BRAB) Publication 33, and accepted engineering practice.
If you have any questions, please call me at 972-878-3647
PTF0207022
fSqely,
All
F,OF�
•:
MEDINA
211912007
A.G. (Tony) !Medina
Registered Professional Engineer
PHONE: 972.878.ENGR (3647) • FAX: 972.875.1398 • E-MAIL: info@txfoundations.com
PROVIDE STEEL LINTELS AT ALL
MASONARY OPENINGS AS REQUIRED
BRICK SOLDIER
@ TOP OF GABLE
13 0
ZO
BRICK Q�JOINS 16'x TOVFID Yx 1'6" AR TR
Tx 6'DL 1/1 MULLED DOUBLE
W 1" PROJECTION
Wl Tx 1'6" AR TR ROWLOCK
(2) 1'4"x 6' DL 1/1 TO SURROUND WINDOWS
PLAN # 1784 lassic
ADDRESS
LOT 902 TURTLE DOVE TR 2 Century
BLK 9 Homes
SUBDIVISION DOVE CROSSING
40'0"
29'2"
7' 1 1/2" 3' 3 3/4- 5-33/4" JQ 13' 5"
2- 815..
06 5'0' 3'0'x
0* 4. 0"x 4'
10, 10"
2-10-
5'0"
;o
-.F - ---------------------
CLG
IASTR SUITE
O
SL 8'- 10'CLG
cli
N
6' 5" 6-4"
LJm
zo
PORCH
ao
12' 9. 34
80
1 2'8'
BDRM 4
8'CLG
2'4"1
00
04
---------------------------------------
zo
FAMILY
co
SL 8' 10- CLG
12'5" 1.2 6
18'8"
00
BDRM 3
8'CLG to
b
0
4- 3" L 81 11"
cq
42- BAR
r-
cli cD
N 8'CLG
BDRM 2 zn Z-!:
-------
8'CLG
io
io
U11. D
;o
BREAKFAST
6 zo
04
CL,,
zn N
SL B' - 11 CLG ;,KITCHEN
k�v
: A,
2-1-
WH
(97-4-
LJ
1" 3-0- i. 5"
- 11h
13-2"
zo
xkw' , -" -
2
A*AC
Li 1 �12A"IC
ESS
GARAGE
3'0" 10' 3"
FOOTAGE
co
V CLG
LIVING 1784
DINING/LIVING:
N
GARAGE 438
PORCH 98
SL 8'- 1V CLG
TOTAL 2320—
--- --------
COPYRIGHT 2000
FRED BURRIS &
t'i A001f' f'C:k1'r"DV UnRACC!
E I
MET J=Em I
22-0" 4'8" 13'4"
40-0"
PLAN #
1784
Century
Home
ADDRESS
902 TURTLE DOVE TR
LOT
2
BLK
119
[SUBDIVISION
11DOVE CROSSING- 1�
NOTE.
z:
1) SHADED WALLS TO 2" x 6" FOR PLUMBING
2) ALL HEADER HEIGHTS TO BE 6-10" UNLESS
OTHERWISE NOTED
3) PROVIDE TEMPERED GLASS WHERE NEEDED
SEE ELEVATIONS FOR
WINDOWS SIZE AND LOCATION
ROOF AS SELECTED
@ 8:12
RIGHT ELEVATION
ROOF AS SELECTED
@ 8:12
LEFT ELEVATION
SIDING TO BE
ALL TEMPLE BRAND
HARD BOARD
,010..
REAR ELEVATION
PLAN#
1784
lassie
Century
Homes
ADDRESS
902 TURTLE DOVE TR
LOT
2
BLK
9
SUBDIVISION
DOVE CROSSING
"""wj "•".o.. "y �ry..a"i.
8' 1 1/4" PLATE
V
Zo
ROOF DETAIL
NOTE:1) Foundation anchor bolts at
6'0" o.c. as per 2000 IRC
sec. R403.1.6
2) All framing and structural
design to meet 90 m.p.h.
wind criteria as per sec.
R301.2.1 and table R301.2(4)
2000 IRC code.
3) All lower sole plate to be
Pressure treated as per
sec. R323. All fasteners
00 to be hot dipped galv. steel,
stainless steel, silicon bronze
or coper only as per sec. R323.3
4) Provide hand rails on all stairs/steps
with a minimum of 2 risers as per
sec. R315. (min. stair tread 10
max. riser 7 3/4" sec. R314.2)
5) Masonary veneer anchorage of
24" horizontal and 18" vertical as
per sec. R703.7.4.1 and weep holes
at a maximum of 33" o.c. as per
sec. R703.7.6.
a' CLG
BDRM 4
B' CLG
------------
BDRM 3
B' CLG ti
BDRM 2
a'CLG Q
it. P 1 a'r;'a"`
I 4X22ATTIC I
I l — ACCESS I
GARAGE
8' CLG d
COPYRIGHT 2000
FRED BURRIS &
CLASSIC CENTURY HOMES
MSTR SUITE
SL 8'-10'CLG
LOCI( d WIRPE
FOR FAN ONLY
A
-- 11
� II
i II
� 11
iisssiiiiiiiiisssis"siiiiiii■
PORCH
--------------------
--------------
•,FAMILY
SLB'-10'CLG
4y}2L"�BAR
BREAKFAST
r-� I
11 SL 6'-10'CLG
°
I I •'
I� KITCHEN
41
�
OP
_______
PANT
.... REF -
7-
DINING/LIVING
SL 8'-10.4G
NOTE: 1) Lighting on stair to correct from switch 0 top to
light mounted on wall s middle of stairs to switch
6 bottom of stairs per sec R303.4
2) Smoke detectors will be hard wired in series
w/ battery backup power as per sec. R311
3) Provide 110 outlet i Ilght near HVAC unit for
service with switch.
PLAN a 111784 ELECTRICAL PLAN
ADDRESS
LOT
BLK
SUBDIVISION
e,assic
Mm
Century
Homes
m.pnp x.a. °r...rei� al! w.ntr
Electrical
telling fan spotlights III
fluorescent Fixture
o
pot light
vanity bar light
®
fan
light
Qb
outlet
outlet 220v
outlet gfi
e
smoke detector
g
switch
q,
switch 3 way
TY— 2X4 SIDIM, EXrMU01 PALL
SF@+GIFS
III /x.. SHEATHING
pN.-lNlqus Aa VENR tAnIFS �i xa•nc
ZM mris.II.,
11 AL11-orl STFa1 FNDS ATAIDGE-ro aE INSTALLED SD iNAT
WT.G shim— AIA FLOP LS NOT IMSMt.cTm
I—ATTMSNAIIUN
TRUSSRACMGANDTHICXNESS
Izr .—A-TOIIEDLTFAA@
BYFNGNEEIt Am. ZAf MFTnls (i xr OC _
IMFAIOR-UNOFINISH
zxnonuM Tun
12 DSNEATHMc
x Wars
Ln.S
aATT MSInAnIM' fUR ZI' OF Fl
w�nrxnn ncirrcnuXMG
11TICAL xAa 1xi(T FATERNR WALL
it
_ _Xa TW lLATEs FTSCL,
1' FACE aRiCX
METAL aRin:r1E5
ACE
Iz
silii
?SN Fwn.G
AIx a1R
SIODf rr,lf'Ac
a
OF 1tnU 11JTU UNDEIUIDE
EOIIALLY srACED VEAT$
Of iLWAAISt SOvoc
a.
al)1ATT MSLT.,TIUN
I.T SNEETRIX].
iR'EET VEIN EVERY )ADtRICX Qf OC
AT 10TTOMI
METAL 1RNA-1
1•AIRSPAM
METAL axNa TIES
I'AnlslACE
An' SHFATx
Iry sHEATHMG
I, 1Ma1Elt
RI SITTIN E.•
RM1AT
1H
Anl lAAaIEA
LASITTIKSU•OC
or-NATIUA
ITP CNFETROCA
RII aATTIASULATION'
ITSNEETRUCA
MOLT ga OC MA%
' • �
ALL SLV gMETSIUNSTML1NEscFS
el ; • �
LUJHFDICTJPLYTroak UkILUONFW IY
ENCMFrzL
TYPICAL ROOF
,
IR"
SHINGLES : 'n 'Aa
PLYWOOD SHEATHING
c/w "H' CLIPS
MIN. 2"X6'
CONTINUOUS
RAFTERS 0 24" o.c.
BATT INSULATION
AIR VENT BAFFLES
•14" o.C.
ROOF PI'
END AT RIDGE
TO BE INSTALLED r
SO THAT
AIR FLOW 15 NOT I (OVERHAN II/'
RESTRICTED
DECKING
MAX.
WOOD FASCIA
SOFFIT MATERIAL
TYPICAL BRICK EXTERIOR WALL
FACE BRICK
I' AIR SPACE
112" SHEATHING
2"x4" STUDS • I6" o.c.
BATT INSULATION CITY OF LOCKHART
112' SHEETROCK TYPICAL ROOF OVERHANG DETAIL
I
—sa-sxEETaonc
MICAL xxa RRICX EXTraIW
a'LA(LtRICX
—At. I.mS
-An RACE
1/a'SXGT
Au aAxuEA
hASTU05� IC�c
RM tATT1I6ULAnON
Ir.•sxEETxocx
JaOLT+A6 0 C MA%
ixa urnoM lurE rxu
J ' '� ALL SLAT DDIENSIUNS nDCKNFEES
'I � e III 4RMNFMCFAtkAx roaE IIEIt•_uuxeun
-I .. LY. ENCIr>Eelt
TOP VIEW U.
CHIMNEY CAP
LL
2X4 BAND
N
2X4 FRAM G - —
MEMBER I — 1i — r—
TYPICAL WALL DETAILS
SIDE VIEW
NOTE:
1) Foundation anchor bolts at
67 o c as per 2000 IRC
sec R403.1.6
2) All framing and structural
design to mat 90 in p.h
wind criteria as per sec
R301 2 1 and table R301.2(4)
2003 IRC code.
3) All lower sole plate to be
Pressure treated as per
sec R323 All fasteners
to be hot dipped galv steel,
stainless steel, silicon bronze
or toper only as per sec R-323 3
4) Provide hand rails on all stans/steps
with a mmmTum of 2 risers as per
sec R315 (min stair tread 10":
mu nser 7 3/4" sec R3142)
5) Masonry veneer anchorage of
24" horizontal and 18" venical as SPHUE SMALL
Nor PASS—U
per sec R703 7 4.1 and weep holes
At a maximum of 33" o c as per HANDRAIL 1 INI' MIN
sec R70376 -....". TO25/11— :Sin
------------------------------
❑]
G �
p X �I�N-{'TREAT
xW I O U
zz
Q � F
CO I i
Co
STAIR DETAIL IRC 2003
2' 4" 1 101011 MIN.
CHIMNEY
CAP
2X4 BAND��
2X4 FRAMING i
MEMBER
OSB
SIDING
REn IRN END.STo
w.su nR rnsr
18" FLOOR SYSTEM
STRINGERS
j(3)2x12
F
5/8" TYPE DRYWALL
UNDER STAIR STRINGERS
a
V
HANDRAIL Q 34"-38" MAX
FIRST FLOOR
lassie
Century
Domes
MaAdnj HDme a71rnersh , Affordable
Area Calculator:
Description
Window Area Total: 183.06
02/05/07 09:50:59 1/1
Area Calculator:
Assembly Type
Description
Door Area Total: 55.56
02/05/07 09:50:59 1/1
MIN. 3/8" WOOD STRUCTURAL
PANEL SHEATHING (SINGLE
SIDED FOR 1 STORY.)
EDGE NAIL 8D COMMON,
6" O.C. (1 STORY)
FIELD NAIL
8D COMMON, 12" O.C.
2 - 2" ANCHOR BOLTS
EMBEDDED 7" MIN. (1 STORY)
HEADER CLEAR
SPAN ACROSS
-8" MIN
0
T
n .
1800 LB HOLDOWN
ONE-STORY STRUCTURES CAN USE
SIMPSON HTT16, PHD2, HDU2, OR
STHD10 HOLDOWNS.
ALTERNATE:
1-STORY- 2'-8" MIN.
TYPICAL BOTH SIDES
Q
0
T
FRONT VIEW
HEADER CLEAR
SPAN ACROSS
IL'2- SIMPSON STHD10
EMBEDDED IN CONCRETE
@ SLAB POUR - TYPICAL
2'-8" MIN
.o..IIII.
.
t
a
�
0
L/4 I, I, I,
MIN. 3/8" WOOD
STRUCTURAL PANEL
SHEATHING (SINGLE SIDED
FOR 1 STORY.)
EDGE NAIL 8D COMMON,
6" O.C. (1 STORY)
FIELD NAIL
8D COMMON, 12" O.C.
2 - 2" ANCHOR BOLTS
EMBEDDED 7" MIN. (1 STORY)
L/4
TYPICAL BOTH SIDES
r
m
m
m
P�
m
�
o
x
Z
0
b
m
D
Zo
Z
K)
�z
02
b
0,
�O
�00
h„y
i
8'-0' WALL
02
z
DRAWN BY: A. BERNAL
SHEET
401 S. CLAY STREET
rAGT*AENNL% TEXAS 75110
SCALE: 3/32' = 1-0�
'
CHECKED BY. A. G. MEDINA, RE
Engineering, LLC
APPROVED.
OF 1
DATE FEBRUARY21, W07
REVISION
A.G. MEDINA P.E.
TELE: (972) 8783647
FAX: (972) 875-1398
EMAIL: agtm@agtmengr.com
AGTM JOB CODE:
BWPO207079
r
m
n
8'-O' WALL
A�'
-
•1� N
(ri m
0
—n
x
z
b
m
D
BRACED WALL PANELS �� y1--OF,r�'�v
CLASSIC CENTURY HOMES
5001 HWY. 287 SOUTH
ARLINGTON, TX 76017 � *
A. C;,
CONTACT: FERNANDO - 817-561-4369 ...
5099�5 �OZ
JOB: l �is�r�;: •'
PLAN NO. 1784 4 ?
1� NA�-��'�
LOT: 2 BLK: 9 SUB: DOVE CROSSING ham►'
902 TURTLE DOVE TRAIL THE SEAL APPEARING ON THIS
COLLEGE STATION, BRAZOS COUNTY, TEXAS DOCUMENT WAS AUTHORIZED BY
A.G. MEDINA, P.E 50995ON2121/07.
BRICKLEDGE WHEN
BRICKLEDGE WHEN APPLICABLE 72 # 3 @ 45 WITH 2'-D'
BENT @ 45' TYP. @
3�. BRICKLEDGE WHEN ✓ APPLICABLE
t APPLICABLE - � ALL CORNERS
SLAB STRAND 3' '�
WHERE APPUCABLE
CHAIR �$•1t��^ <'p;'
to 7 _ .. •Jl{ li Y +P•L�'• Y'^^• �. ' ryly'i''� CUSHION
CUSHION -3 nt r.=.y-fC: I'I 14 SAND, TYP. G _ o = _ •o - �y t {gi CHAIR . 6' 6' `2-B.S�� DETAIL
SAND, TYP. • •�
t _ L� 4i1 I t TOP OF POST -TENSION STRANDS m ¢ _ ➢�=w-m1 L�,- ',I IIJIP I CUSHION ��N
TOP OF I Ihl POST -TENSION STRANDS GRAOE III O > _ _- J>� I) I'y'f SANG, TYP . 6' . 6'
"��IWHEN INDICATED LLI I I=1� �I I •? • u III III 'I r i'� TT7 'S' STRAND
GRADE WHEN INDICATED <'- it ON PLAN, TYPICAL SQ 'I I- TOP OF M �n�,liw.11
II 0 Z POST -TENSION STRANDS ANCHOR
"' " . • • ON PLAN, TYPICAL • ' a 2 ° 'I- _ -III-11 I WHEN INDICATED
/ I,t 2-#5 BARS w ¢ H ¢ =III- I�I III GRADE ,' ` - .I ",I,
O a - CHAIR '� - ON PLAN, TYPICAL in
DRAPE BEAM STRAND ��'' DRAPE BEAM STRAND w w -I I -I IItl
WHEN INDICATED DRAPE
INDICATED p IE —ems • - ' I' /'GRAPE BEAM STRAND 7/BS'STRAND
ON PLAN, TYPICAL IIWHEN INDICATED
O `. ON PLAN, TYPICAL N4 BARS Q ON PLAN, TYPICAL
M3 SUPPORT STAKES VAPOR @ 12.0 C.
aY3 SUPPORT STAKE RETARDER SEE PLAN FOR EACH WAY UNDIISTUR E D ANCHOR
TYPICAL F P DIMENSIONSSOIL
DETAIL "A° DETAIL "Al " } i 2- #4 BARS VERTICALLY SLAB STRANDS
an SPACED @ 12- O.0 AS /f FORM BOARD
DETAIL "Ell N 7. REQUIRED PER BEAM —
DEPTH
J
CHAIR
NOTE IT IS IMPORTANT TO USE THIS DETAIL ) "' • •/
✓ BRICKLEDGE WHEN #'4 VERTICAL WHEN THERE IS A 4' OR LESS SLOPE IN THE
APPLICABLE SUPPORTS @ 46' FOUNDATION FOOT PRINT AREA TO INSURE 3¢3
THAT SETTLEMENT DOES NOT OCCUR, THE
1- #4 BACK UP BAR BOTTOM OF THE PERIMETER BEAM MUST 1 � p • .
rs STANDARD DEEPEN �PENETRATE UNDISTURBED SOIL AMIN OFI2 / 7 p TIEWRE
CHAIR �' ,13 j' CHAIR ,f ice: BEAM DETAIL CHAIR
`CHAIR LESS THAN 54'
sue STRANDS SLAB STRANDS / //•`�•- ' I I SLAB STRANDS h
WHERE APPLICABLE �" Y- I• I WHERE APPLICABLE m - _- WHERE APPLICABLE CHAIR LAYOUT
BEAM STRAND �) 2- 05 BARS � ) N A4 BARS @ 12
WHERE BEAM 0 C E W.
WHERETO - , /- DRAPE BEAM SLAB STRANDS
APPLICABLE fF4'
H N3 SUPPORT STARE APPLICABLE z p I l �II" STRAND ` SHEATHING CUT BACK BEHIND ANCHOR
° yJ Y3 SUPPORT STAKE II� - ,ICI WHEN INDICATED I��I[ is (CARE SHOULD BE TAKEN TO
l,l ON PLAN, TYPICAL CHAIR --�' °�tl' I _ d ENSURE SHEATHING DOES NOT
PROTRUDE INTO THE ANCHOR)
q I.. s
II 11 `� 1"
DETAIL B DETAIL "B1° '° oPE 11 J. 1 M
BRICKLEDGE WHEN POP 'I I' STANDARD oil 5„I�I�I II I,�I;��M� WOOD
6 APPLICABLE r,r
op� APPLBRICKCAB EE WHEN rO�ORP�r DETAIL G DROP DETAIL ] W FORM EXCAVATION
BRICKLEDGE WHEN ' BRICKLEDGE
//- -,,;•iibb APPLICABLE ✓ WHEN APPLICABLE TENDON INSTALLATION
2 1- #4 BACK UP BAR AT STRESSING END
�� �+fT_ I• Ta` _ wQ,' / / g ',iN /-44 BARS @12'OCE W.
fd �' 11 y V• - 'i -1-44 BACKUP BAR
-p, CHAIR/ m SLAB STRAND
TOP OFF/ - $ 111 i,'..' /� {`.!•- - -CHAIR T# -CHAIR ... + ,-'t
POCKET
GRADE J r - 1 "� -'--SLAB
SLAB STRANDS t II.I I f/ Ild ll 1 N __- FORMER
WHERE APPLICABLE TOP OF 4 7fII u, SLAB STRANDS { II _ r 16' (12- MIN) 1.
"•7 GRADE / i/ II WHERE APPLICABLE y,y' i� y ,�I SLAB STRANDS I -I
DRAPE BEAM STRAND �3 ,irjN; WHEREAPPUCABLE '11= I�•R*I CHAIR
2- #�5 BARS I \
rn - WHEN INDICATED �- _ :#4 BARS @ 12' -I I I
-I1T'� ON PLAN, TYPICAL �t•+r DRAPE BEAM G� rl I _SLAB STRAND
O �T •�STRAND ' I; �I O C E W I I .'1 ..CUT
TOP OF / �.'• - n 1 I HERE PLASTIC
WHEN INDICATED GRADE J - `J td� I I� � DRAPE BEAM BEAM
ON PLAN, TYPICAL yam, II I I STRAND 3'-0' MAX • W EXCAVATION wOOD
WHEN INDICATED -BEAM STRAND `FORM
0 ON PLAN, TYPICAL L AS SPECIFIED
1- N4 FOR L = IVOR LESS \ --f
„ „ E 2-M4F0RL=15'TO25' COMPLETED
DETAIL C DETAIL "Cl" ° g6" NOTE: DETAIL"F" 3-N4FOR L-26'TO36' STRESSING -END INSTALLATION
CAN BE
BRICKLEDGEWHEN DETAIL "F„ SUBSTITUTED DETAIL "F1"
APPLICABLE FOR DETAIL fl'.
6 y - S' STRAND AS
3iyi I = I BRICKLEDGE WHEN / SHOWN ON PLAN 1' MIN
APPLICABLE
FIXED -END S LAH TING
1- N4 BACK UP BAR N I I ANCHOR
III - -CHAIR 3
���✓✓✓ _ �D•-- t�/ Il li YI I l�fi -, TYP
� %`'. ,�1,41 '1 CHAIR
� SAND,
cl
=�^ 1 r .TIP /� `.X ra, I '\ _ � \ �
70P OFF -g 'r l� POST -TENSION STRANDS r I • SLAB STRANDS y ! sI�I I I - CHAIR � / 1 STRIP
GRADE=/ t "•a WHEN INDICATED 4'Af II WHERE APPLICABLE �' ' \ ♦ ,� SHEATHING
- ,••y_i I(f� � IIIII, 1-, SLAB STRANDS
_ I ON PLAN, TYPICAL v. �'f`+�cgY - '� '?7.1 WHERE APPLICABLE
i i V
`- STIRRUPS \-STIRRUPS .Y4 BARS @ ITI I `-'BS' STRAND AS 20d NAIL
;A �`.• WHEN SPECIFIED WHEN SPECIFIED i O C E W 2 x D TYPICAL SHOWN ON PLAN l- L (MIN)
� r L INSTALLATION
FIXED -END (DEAD-END)
DRAPE BEAM ;Y3 STAKES AS REQUIRED WHEN (2) -BS- STRANDS ARE SPECIFIED IN THE BEAM, -WOOD
° r' � -3- 04 BARS \•-3- #•4 BARS s � WHEN INDICATED STRAND TO MAIL CLEARANCE FROM THE TIE 'BS'STRANDS TOGETHER FORM TOP VIEW
TOP G BOTTOM. 70P 8 BOTTOM T� V� ON PLAN, TYPICAL AND INSTALL SIDE BY SIDE
° pp BOTTOM OF THE BEAM AS A SINGLE'BS' STRAND.
1 ESS 54' MAX SPACING INSTALL ANCHORS SIDE BY SIDE
SEE "2-BS' DETAIL STANDARD DETAILS
DETAIL'ID" DETAIL "H" DETAIL W" BEAM STRAND "BS" DETAIL
3E0LN0=1id NOTES:
6"Al 8 SPACES @ 3'-6" ± 3 SPACES 2 3'-8" ± 6" 1. TO PREVENT SETTLEMENT DUE TO SOIL CONSOLIDATION, aj �.••; ••�l�I)
ALL EXTERIOR FOUNDATION BEAMS MUST BE FOUNDED A: • '•��!`�`
d' N MINIMUM OF 12 INCHES INTO UNDISTURBED SOIL. WHEN J ; 0 :tff
co A (O FOUNDATION SITE CONTAIINS FILL (MAX, 3'4), THE DEEPEN U. ; ; LV
Q,
� (cO � CO CcO(D In m DIAGONAL: BEAM DETAIL SHOULD BE USED IN THESE FILLED AREAS.
' CD ' 73'-1" FOR SITES WHERE FILL IS GREATER THAN V-0", PLEASE '. ; ;`�+ �• ��
!� CO Cn NCA co Cnm fA Cn CAN CONTACT AGTM ENGINEERING LLC TO INCORPORATE PIERS YA- goog
S.S
31 INTO THE DESIGN. 4 41 000
BS32 - 2. 3000 PSI, CONCRETE SLAB.*'. ;���
cn +I I I 3. 4" OF CUSHION SAND UNDER CONCRETE SLAB IS
w � I I I I A d RECOMMENDED.
Q *- I c? I I Cy) C� C� LO 4. PROVIDE A 6 MIL POLYETHYLENE MOISTURE RETARDER
S31 I I co I I LO LID LO C/) BENEATH SLAB AREA. z
N
N� I I I I I m 5. ALL STRANDS 1/2" DIA, - 270 K. O
S42 L _ _ _ _ _ _ - J L - _ _ _ _ _ J L___ _ _ _ _ _ 6. THIS FOUNDATION DESIGN IS CONSIDERED INVALID W Q
2-BS43 r - J � r r - - - - - - - l UNLESS ACCOMPANIED BY A LETTER FROM AGTM I I I I I ENGINEERING LLC AUTHORIZING ITS USE ON A SPECIFIC Q m Z
I I I I I #4 BARS I I LOT & BLOCK, OR ADDRESS. Q CID
S42 I I = I I @ 12" O.C. I I w u? O -� 0 7. PLANS CAN BE REVERSED ON LOT AT BUILDERS Z =
I I I I I I I p 1 DISCRETION. +^- V
I I I o I I I I y I >_ Q 8 00 QU
I I I 1 1 I I I 8, PLANS ARE FOR STRAND AND BEAM PLACEMENT ONLY. N (� w w
S42 I I I I I I -_�J� SET FORMS, DROPS, HANDICAP RAMPS, IETC., BY L L H Q r 0O Q
I I I I I I ARCHITECTUAL FLOOR PLAN OR AS SPECIFIED BY
L-------- L_ _____J L__-_____ L E OWNER/GENERAL CONTRACTOR. Z Z O "� Ir
BS43 r - - - - - - - r - - - -/-511
(- - - - _ 9. AT CONTRACTORS OPTION, LIVE END AND DEAD END W Z z � J m
S42 I I I II I DROP REVERSAL IS PERMITTED. U 2 Z W z m cr Z
I I I I II I 10. AT CONTRACTORS OPTION, BRICK LEDGE MAY BE (n *- LL- QQ rn � Q
I I INCLUDED OR OMITTED AT EXTERIOR DOOR OPENINGS. z U p J Y F- I=
S42 I I I o 1 11 1 I 11. DRAINAGE, DRAINAGE, DRAINAGE. THE FINAL GRADE Q Fa- d. N rn m
I „ I I I I 1 1 „ I w
9-10 I 9-6 I I 11 3 AROUND THE FOUNDATION SHALL BE 8" BELOW THE TOP OF Z
I I I I I I I I THE FOUNDATION AND SLOPE AWAY FROM THE U) U Oo W
S42 _-_____J L_ _____J L_ ______J L----_-___ FOUNDATIONAMINIMUMOF3"IN6-0". J
+1 BS43 r--------�-- -----�-------� r---------- O o
o I I I I I I I I N 12. VIBRATE CONCRETE @ ALL CABLE LOCATIONS Q, Om
S42 I I 1 I I ESPECIALLY AT CORNERS WHERE SEVERAL CABLES ARE 0
I I I I I I I ANCHORED. MAXIMUM CONCRETE DENSITY IS REQUIRED
I I I Q 1 1 I I A TO INSURE THAT A "BLOW-OUT," DOES NOT OCCUR DURING rel
I I I o I I I I I w T C? N
w r CABLE STRESSING. _
Q S42 I I I I I I I 1 13. THE FOLLOWING SYMBOL INDICATES DROP IN o p
I I I DROP B 1 1 I FOUNDATION. THE AMOUNT OF DROP AND EXACT c
c0 BS43 L_--__—__J L_ _ _ _J L__�___ _J L— LOCATIONISTOBEDETERMINEDBYPLANORAS
S42 DIRECTED BY OWNER/CONTRACTOR.
--------�-- --- -� r--- -------------
I II II II I �
I II II II I d
LL
I II II II I
S42 1 1 i o 1 1 i i 1 FOUNDATION: o
I I I I I I I I 1, THICKNESS T= 4" O
S42 I I I i i 1 2. BEAM WIDTH W= 10" U
2-BS43 L _ J L_ _--__J L_-_____J L_____-___J 3.BEAMDEPTH D=33"
r---- --� r-- -----I F-------� r---------� 4. AREA = 2322 SO. FT. m 9 0
I II II II I a u
S42 I I I a I I DROP I I I 5. EST. CONCRETE = 86 YRDS. m m w z F"
c 0 6. SOILS REPORT: z U- 0 0
I I I I I I I I CME TESTING AND ENGINEERING, INC, a
S42 I i t N i i $ LU Lill
t /� I 1806 WELSH AVENUE" SUITE C
I I I I I ;COLLEGE STATION, TEXAS 77840 �� E
S42 L __ J L _ ___ J L_ L _ ___ __J J W 3
_ _ _ _ _ _ _ _ PROJECT NO. 26116
BS43 r- i I i i DATED: OCTOBER 2, 2006 0 QIt m
Z6E
g (D ro ro
F c Lu r,
CD w � §
CAUTION:INTHE PLUMBIVENT NG
Cj9
—STEEL REOUIRED. SEE DETAILS PASSES THROUGH A PLUMBING OPENING, AUTION• VIBRATE ALL CABLE LIVE4-11.1.11 GMOVE CABLE TO EDGEOFOPENING. AND DEAD ENDS TO ENSURE MAX,R UJ LL
CABLE SPACING CAN BE ADJUSTED, BUT IN DENSITY CONCRETE, ESPECIALLY Q `.J
NO EVENT CAN CABLE SPACING BE AREAS WHERE MULTIPLE STRANDS
40'"0„ GREATER THAN5'0O.C. COME TOGETHER Q W
BUILDING PERMIT
CITY OF COLLEGE STAATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00000573 Date 3/20/07
902 TURTLE DOVE TRL
005401-0209-0020
RESIDENTIAL, 1 UNIT DETACHED NEW
DOVE CROSSING PH 2
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
117744
Owner Contractor
------------------------ ------------------------
CLASSIC CENTURY HOMES
5001 HWY 287 S
BURLESON TX 76028
(817) 561-4369
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1784.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit Fee . . . . 514.00 Plan Check Fee .00
Issue Date . . . . 3/20/07 Valuation . . . . 117744
Expiration Date . . 9/16/07
Qty Unit Charge Per Extension
BASE FEE 460.00
18.00 3.0000 THOU BLDG, VAL 100001-500000 54.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM_ R UU H-FRAMED SIZE 22"
------------------------------- ----- -- -- - --------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE SATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 07-00000573 Date 3/20/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
BUILDING DEPT REP ESENTATIVE:
APPLICANT: ����
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000573 Date 3/20/07
----------------------------------------------------------------------------
Special Notes and Comments
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIAT VICINITY OF TUE
-
--------------------------------------------- ----�----------
BUILDING DEPT REPRF .B�TTATIVE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 07-00000573 Date
3/20/07
----------------------------------------------------------------------------
Special Notes and Comments
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
---------------------------------------------------------
Due
Permit Fee Total 514.00 514.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1264.00 1264.00 .00
.00
---------------------------------------------- ------ ---------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000574 Date 3/20/07
Property Address . . . . . . 902 TURTLE DOVE TRL
Property ID: 005401-0209-0020
R #-
Application type description TEMP POLE
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
CLASSIC CENTURY HOMES
5001 HWY 287 S
BURLESON
TX 76028
(817) 561-4369
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/20/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------------------------------------- ----- A 1�-� ----------------
BUILDING DEPT REPRESENTATIVE: JtAO45t
APPLICANT: