HomeMy WebLinkAboutRES2007-00571 903 TURTLE DOVE TRL BUILDING PERMITPREPARED 7/11/07, 12:02:13
INSPECTION TICKET
PAGE 7
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 7/11/07
-----------
ADDRESS
--------------------------------------------------------------------------
903TURTLE DO TRLJ SUBDIV:
CONTRACTOR CLASSIC CENTURY HOMES PHONE (817) 561-4369
OWNER
. .
PHONE
PARCEL
. . 230100-0207-0370
APPL NUMBER: 07-00000571 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/12/07 RH
BLDG, FOUNDATION -SLAB TIME: 17:00
4/12/07 AP
April 11, 2007 3:35:22 PM glsouth.
04/12/2007 10:22 AM RH PDA
Strings up, slab ground installed.
B115 01
5/15/07 RH
BLDG, FRAMING TIME: 17:00
5/15/07 DP
May 15, 2007 10:23:06 AM kwolfe.
05/15/2007 04:27 PM RH PDA
Simpson panel in front room should run to top.
Need proper
apa nailing. Need joist hanger at RTA. Seal all
ext.
joints. Complete fireplace flue and have proper
clearances.
B115t2
5/21/07 OC
BLDG, FRAMING TIME: 17:00
5/21/07 AP
May 21, 2007 10:49:37 AM acarter.
B130
01
5/24/07 JGM
BLDG, INSULATION TIME: 17:00
5/24/07 AP
May 23, 2007 11:51:34 AM acarter.
B125 01 7 1/PP7 BLDG, FINAL TIME: 17:00
I O}C. July 11, 2007 8 : 22 : 15 AM glsouth.
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
I1 � ��&
G(t
0
Q�
(7/13/2007) Kim Wolfe - Re: Calling for C.O. @ 903 Turtle Dove Trl Page 1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 7/12/2007 4:22 PM
Subject: Re: Calling for C.O. @ 903 Turtle Dove TO
Fred with Classic Century Homes has been notified.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 7/11/2007 3:41 pm >>>
Water and sewer both need to be raised.
Paul
>>> Amber Carter 7/11/2007 12:20 PM >>>
by #07-571
any issues?
Date. 7/11/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 571
Address: 903 TURTLE DOVE TRL
Type
Inspection Type Code
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
04/12/2007 10:22 AM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
13115
BLDG, FRAMING
IC
05/15/2007 04:27 PM RH PDA
6115
BLDG, FRAMING
IC
Simpson panel in front room should run to top. Need proper
B115
BLDG, FRAMING
IC
apa nailing. Need joist hanger at RTA. Seal all ext.
B115
BLDG, FRAMING
IC
joints. Complete fireplace flue and have proper clearances.
Page 1
WF0883971 / 001 City of College Station PAGE 1
REQ. DATE: 03/27/07 03/27/07 11:43:35
LOCATION: 903 TURTLE DOVE TRL LOC ID: 204522
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/27/07 SCHED COMPLETION: 03/27/07
********************************************************************************
JOB ORDER RESULT COMIMTS
WFO882127 / 001 City of College Station PAGE 1
REQ. DATE: 03/20/07 03/20/07 14:20:36
LOCATION: 903 TURTLE DOVE TRL LOC ID: 204522
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/20/07 SCHED COMPLETION: 03/20/07
********************************************************************************
JOB ORDER RESULT COMMENTS
55.00'
---
0
M
10' P.U.E
-------------
ONE STORY
SINGLE FAMILY
BRICK RESIDENCE
o
O
PLAN # 1548
O
^�
7'-611
40'-0"
7'-6"
18' CONC.
DRIVEWA
0
N
- - - -
' P.U.E
- - - - - -
- -
55.00'
903 TURTLE DOVE TR
25' BL
LOT 37, BLOCK 7
PHASE 2
DOVE CROSSING SUBDIVISION
COLLEGE STATION, BRAZOS CO.
TX
ElfPSED
3 i v
BUILDING VERMIN:
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000571 Date 3/20/07
Property Address . . . . . . 903 TURTLE DOVE TRL
Property ID: 005401-0207-0370
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 102168
Owner
Contractor
------------------------
------------------------
CLASSIC CENTURY HOMES
5001 HWY 287 S
BURLESON TX 76028
(817) 561-4369
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1548.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
469.00 Plan Check Fee .00
Issue Date . . . .
3/20/07 Valuation . . . . 102168
Expiration Date . .
9/16/07
Qty Unit Charge
Per Extension
BASE FEE 460.00
3.00 3.0000
THOU BLDG, VAL 100001-500000 9.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM OUGH-FRAMED SIZE 22"
- x
BUILDING DEPT REPRESENTATIVE: A
APPLICANT:
BUILDING PERMIT,
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Page 2
Application Number . . . . . 07-00000571 Date 3/20/07
----------------------------------------------------------------------------
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEA URED AT THE
---------------------------------------- -446�� ------------
BUILDING DEPT PEPRESENTATIVE:
APPLICANT:
BUILDING PERMIT,
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 07-00000571 Date 3/20/07
----------------------------------------------------------------------------
Special Notes and Comments
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIA E VICINITY OF THE
--------------------------------------------- ----�-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING 2ERMIT
rITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
4
Application Number . . . . . 07-00000571 Date
3/20/07
----------------------------------------------------------------------------
Special Notes and Comments
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 469.00 469.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1219.00 1219.00 .00
.00
-------------------------------------------- --�.-- - ------------------
BUILDING DEPT �EP�ENTATIVE:
APPLICANT:
TEMPORARY POKE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00000572 Date 3/20/07
Property Address . . . . . . 903 TURTLE DOVE TRL
Property ID: 005401-0207-0370
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . DOVE CROSSING PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
CLASSIC CENTURY HOMES
5001 HWY 287 S
BURLESON
TX 76028
(817) 561-4369
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/20/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00