Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Application (11-148)
FOR (J114 NO.: OFFICE U E ON Y CASE DATE SUBMITTED, ' ' L TIME: . CITY oCOLLEGESTATION Home SITE PLAN APPLICATION ) HomcofTexrtsAeS'MUniversity' STAFF: �'`"' GENERAL MINIMUM SUBMITTAL REQUIREMENTS: © $932 Site Plan Application Fee. IJr< $350 Non - Residential Architectural Standards Building Review Application Fee (if applicable). © $600 (minimum) Development Permit Application / Public Infrastructure Review and Inspection Fee. Fee is 1% of acceptable Engineer's Estimate for public infrastructure, $600 minimum (if fee is > $600, the balance is due prior to the issuance of any plans or development permit). © Application completed in full. This application form provided by the City of College Station must be used and may not be adjusted or altered. • Fourteen (14) folded copies of site plan. © One (1) folded copy of the landscape plan. 1fi One (1) copy of the following for Non - Residential Architectural Standards building review or Northgate Building Review (if applicable). 11,k Building elevations to scale for all buildings. "I/ A list of building materials for all facade and screening. ](• r - Color samples for all buildings or list colors to be used from the approved color palette. tiljA Electronic copy of Site Plan e- mailed to csuelectdesign @cstx.gov. • Two (2) copies of the grading, drainage, and erosion control plans with supporting drainage report. © Two (2) copies of the Public infrastructure plans and supporting documents (if applicable). Traffic Impact Analysis or calculations of projected vehicle trips showing that a TIA is not necessary for the proposed request (if applicable). The attached Site Plan Non - Residential Architectural Standards Building Review and Northgate Building Review checklists (as applicable) with all items checked off or a brief explanation as to why they are not check off. Date of Optional Preapplication or Stormwater Management Conference NAME OF PROJECT LAKERIDGE TOWNHOMES PHASE 2B ADDRESS 1198 JONES - BUTLER ROAD LEGAL DESCRIPTION (Lot, Block, Subdivision) LOT 1, BLOCK 1, LAKERIDGE SUBDIVISION APPLICANT /PROJECT MANAGER'S INFORMATION (Primary contact for the project): Name MITCHELL & MORGAN, LLP C/O VERONICA MORGAN E -mail V @MITCHELLANDMORGAN.COM Street Address 511 UNIVERSITY DRIVE EAST, SUITE 204 City COLLEGE STATION State TEXAS Zip Code 77840 Phone Number ( 260 -6963 Fax Number ( 260 -3564 PROPERTY OWNER'S INFORMATION: Name LAKERIDGE LIVING LP, A TEXAS LIMITED PARTNERSHIP E -mail JIMBSTEWART @GMAIL. Street Address P.O. BOX 10028 City COLLEGE STATION State TEXAS Zip Code 77842 Phone Number ( 739 -9944 Fax Number (97 694 -3774 1/11 Page 1 of 11 ARCHITECT OR ENGINEER'S INFORMATION: Name MITCHELL & MORGAN, LLP C/O VERONICA MORGAN E -mail v @mitchellandmorgan.com Street Address 511 UNIVERSITY DRIVE EAST, SUITE 204 City COLLEGE STATION State TEXAS Zip Code 77840 Phone Number ( 260 -6963 Fax Number ( 260 -3564 OTHER CONTACTS (Please specify type of contact): Name NIA E -mail NIA Street Address N/A City NIA State N/A Zip Code NIA Phone Number NIA Fax Number N/A Current zoning R -4 Present use of property UNDEVELOPED - VACANT Proposed use of property MULTI- FAMILY Number of parking spaces required 97- 2B (Total: 357) Number of parking spaces proposed 114 - 28 (Total: 393) Is there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels) on the property? f Yes r No This information is necessary to help staff identify the appropriate standards to review the application and will be used to help determine if the application qualifies for vesting to a previous ordinance. Notwithstanding any assertion made, vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law. Is this application a continuation of a project that has received prior City platting approval(s) and you are requesting the application be reviewed under previous ordinance as applicable? r Yes No If yes, provide information regarding the first approved application and any related subsequent applications (provide additional sheets if necessary): Project Name: City Project Number (in known): Date / Timeframe when submitted: 1/11 Page 2 of 11 MULTI- FAMILY RESIDENTIAL PARKLAND DEDICATION (Fees due prior to the issuance of a Building Permit) Total Acreage 1.96 ACRES # of Multi - Family Dwelling Units Floodplain Acreage 0 27 44,442 X$1646 =$ Housing Units 27 0 # of acres in floodplain 2 # of 1 Bedroom Units 0 # of acres in detention 2 # of 2 Bedroom Units 0 # of acres in greenways 4 # of 3 Bedroom Units 08/27/09 Date dedication approved by Parks & 19 # of 4 Bedroom Units Recreation Advisory Board COMMERCIAL FOR 2 BEDROOM UNITS ONLY Total Acreage N/A 0 # Bedrooms = 132 sq. ft. Building Square Feet N/A 2 # Bedrooms < 132 sq. ft. Floodplain Acreage N/A * Projects that were vested prior to January 1, 2008, per Chapter 245 of the Texas Local Government Code may be assessed a different amount. Please contact city staff for additional information. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. /41_----- ' _ o f _ ,,,,,, di ...iiit 1 r 22- (// Sig . t're - nd ti le l Date 1/11 Page 3 of 11 i CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT Owner Certification: 1. No work of any kind may start until a permit is issued. 2. The permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is re- issued. 4. Development shall not be used or occupied until a Certificate of Occupancy is issued. 5. The permit will expire if no significant work is progressing within 24 months of issuance. 6. Other permits may be required to fulfill local, state, and federal requirements. Owner will obtain or show compliance with all necessary State and Federal Permits prior to construction including NOI and SWPPP. 7. If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre - pour) and post construction. 8. Owner hereby gives consent to City representatives to make reasonable inspections required to verify compliance. 9. If, stormwater mitigation is required, including detention ponds proposed as part of this project, it shall be designed and constructed first in the construction sequence of the project. 10. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that all debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 11. The information and conclusions contained in the attached plans and supporting documents will comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines Technical Specifications, and Standard Details. All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 12. Release of plans to (name or firm) is authorized for bidding purposes only. I understand that final approval and release of plans and development for construction is contingent on contractor signature on approved Development Permit. 13. I, THE OWNER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS FOR THE IN , P., LO' sE ..T RMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND A URA F . ' i - p- 03,-- ty _ _ _ AWAfiriliaric 27.,,t i if' Pro. : y Owner(s) Date Engineer Certification: 1. The project has been designed to ensure that stormwater mitigation, including detention ponds, proposed as part of the project will be constructed first in the construction sequence. 2. I will obtain or can show compliance with all necessary Local, State and Federal Permits prior to construction including NOI and SWPPP. Design will not preclude compliance with TPDES: i.e., projects over 10 acres may require a sedimentation basin. 3. The information and conclusions contained in the attached plans and supporting documents comply with the current requirements of the•City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines. All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 4. THE ENGINEER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS ' OR THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND CCURATE. ®gym ,,, I �U, �`* )11‘ * � . o � �' * 4 Engineer '` ® VER ONICA J B MOF A N N o Date 6 i A4 9 FCis1•e ? °� � -- ( 1943 1/11 FS'" ••••••••• ' , m Page 4 of 11 , The following CERTIFICATIONS apply to development in Special Flood Hazard Areas. Required for Site Plans, Final Plats, Construction Plans, Fill / Grading Permits, and Clearing Only Permits:* \ A(� A. l \J€KlS'I11[COL J Iv t 4 \CIY certify, as demonstrated in the attached drainage study, that the t alterations or development covered by this permit, shall not: (i) increase the Base Flood elevation; (ii) create additional areas of Special Flood Hazard Area; (iii) decrease the conveyance capacity to that part of the Special Flood Hazard Area that is not in the floodway and where the velocity of flow in the Base Flood event is greater than one foot per second. This area can also be approximated to be either areas within 100 feet of the boundary of the regulatory floodway or areas where the depth of from the BFE to natural ground is 18 inches or greater; (iv) reduce the Base Flood water storage volume to the part of the Special Flood Hazard Area that is beyond the floodway and conveyance area where the velocity of flow in the Base Flood is equal to and less than one foot per second without acceptable compensation as set forth in the City of College Station Code of Ordinances, Chapter 13 concerning encroachment into the Special Flood Hazard Area; nor (v) increase Base Flood velocities. ��\\\\ b- •nd those ar -s exempted b � .ci n„ irh ttt� n 5.11.3a of Chapter 13 Code of Ordinances. la I 1 411,j1 Engineer I k ...... , .... , Date 1 9�,G /sTES'' •'s Initial ��1Fs' ... ���� MOW F l N OL ilt * If a platting- status exemptiorrh? quirement is asserted, provide written justification under separate letter in lieu of certification. Required for Site Plans, Final Plats, Construction Plans, and Fill / Grading Permits: B. 1, VW ICL M VV V I certify to the following: (i) =t any nonresidential or m�xl i- Prctr ®411 or proposed to be on this site as part of this application is signed to prevent damage tA • ,strg„ re •or bpntents as a result of flooding from the 100 -year storm. L I i ll ii i ' s RONICA J.B. AN1 9111 I En /� , .s r Engine ill er ? �I+o 9FG /TE /ff., Date a � I '. •• i— tP i<Alv r -i 4 Additional certification for Floodway Eh`taachments: C. I, , certify that the construction, improvement, or fill covered by this permit shall no � re the base flood elevation. I will apply for a variance to the Zoning Board of Adjustments. Engineer Date 1/11 Page 5 of 11