HomeMy WebLinkAbout11-00400100- 00076875 BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764 -3570 FAX: (979)764 -3496
http: / /bpinspect.cstx.gov
Application Number 11- 00000505 Date 3/02/11
Property Address 4032 ROCKY VISTA DR
Property ID: 184100 - 0503 -0190
R #: 356777
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name CASTLE ROCK PH 5
Property Use RESIDENTIAL
Property Zoning PLANNED DEVL DISTRICT
Application valuation . . . 113850
Owner Contractor
MAGRUDER HOMES LLC MAGRUDER HOMES, LLC
PO BOX 10551 P.O. BOX 10572
COLLEGE STATION TX 778420551 COLLEGE STATION TX 77842
(979) 324 -6682
- -- Structure Information 000 000 SINGLE FAMILY
Construction Type COMBUSTIBLE (UNPROTECTED)
Occupancy Type RESIDENTIAL -SFR /DUPLEX
Other struct info A/C SEER RATING 14.00
CEILING 1 R VAL. (FLAT) 30.00
CEILING 2 R VAL -NO ATTIC 30.00
DUCT R VALUE 6.00
EXTERIOR WALL TYPE brick
IMPACT /PRORATA FEES PAID due
FOUNDATION TYPE slab
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT /DET) att
% GLAZING 14.00
GLAZING U- FACTOR .64
HEATED AREA 1725.00
INTERIOR WALL TYPE sheet rock
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
NUMBER OF UNITS 1.00
EXTERIOR WALL INSUL R VAL 13.00
GLAZING SHGC .35
SEWER TYPE public
TRAFFIC IMPACT ANAL (TAZ) 441.00
Permit BUILDING PERMIT
Additional desc . GS
Permit pin number 762872
Permit Fee . . . 502.00 Plan Check Fee . . .00
Issue Date . . . 3/02/11 Valuation . . . . 113850
Expiration Date . 8/29/11
jt 1/444
BUILDING DEPT REPRESENTATIVE:
C
APPLIC °-
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764 -3570 FAX: (979)764 -3496
http: / /bpinspect.cstx.gov
Page 2
Application Number 11- 00000505 Date 3/02/11
Qty Unit Charge Per Extension
BASE FEE 460.00
14.00 3.0000 THOU BLDG, VAL 100001- 500000 42.00
Special Notes and Comments
- This house permitted under 2009 IRC and 2008 NEC and the
following apply to this house.
- Carbon Monoxide Detectors outside bedroom areas, if house
has gas fired appliances or attached garage.
- Tamper Resistant Outlets, all 110v. receptacles.
- Arc Fault Protection per new code, most outlets required to
be protected.
-50% of lighting to be High Efficacy Lighting, (ex. CFL s or
LED s)
- If Shower has Tile Floor, then the Pan Liner Must Be
Inspected for Leaks before tile work is done, a Special
Inspection Should be requested and performed.
-R8 Ductwork is Required, unless a 14 SEER or greater rated
system is used and then R6 Ductwork can be used.
-Make sure attic accesses are insulated to the value of the
cavity around it.
- Habitable Attic Spaces shall be required to meet Emergency
Rescue Egress and Smoke Detector Requirements.
- Narrow Wall Bracing Fully Sheathed with 18" APA Garage and
Dining Room Framing and Interior Anchors and Bracing to the
Right of the Front Door Area.
*AN APPROVED EXPANSION TANK FOR THERMAL EXPANSION CONTROL
SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER
HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE WHICH
CREATES A CLOSED SYSTEM
*ELECTRICAL SHALL BE INSTALLED PER 2008 National Electrical
CODE & LOCAL AMENDMENTS
*ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT
FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,
LIBRARIES, BEDROOMS, SUNROOMS AND SIMILAR ROOMS SHALL BE
PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S)
*ALL 125 VOLT, 15 AND 20 AMP. RECEPTACLES SHALL BE LISTED
TAMPER RESISTANT RECEPTACLES.
*Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
*DEDICATED GARAGE APPLIANCES CIRCUITS WILL NEED TO ALSO BE
BUILDING DEPT REPRESENTATIVE: 0‘74":42-
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764 -3570 FAX: (979)764 -3496
http: / /bpinspect.cstx.gov
Page 5
Application Number 11- 00000505 Date 3/02/11
Special Notes and Comments
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
*WHEN A CULVERT IS USED WITHIN THE RIGHT OF WAY IT MUST HAVE
CONCRETE SLOPED END SECTIONS (6:1 SLOPE) OR APPROVED EQUAL.
*MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER CODE SECTION R602.10 IN
2009 IRC
*ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN OR
HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE
UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR
COVER -UP. A SPECIAL "APA" NAILING PATTERN INSPECTION SHALL
BE PERFORMED PRIOR TO FRAMING INSPECTION AND BEFORE COVERING
WITH A MOISTURE BARRIER.
*If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
*ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
*POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD, MUST
BE IN PLACE BEFORE ANY INSPECTIONS WILL BE PERFORMED.
*WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
*RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
*For residential applications R -8 duct insulation is
required. As an alternative, R -6 duct insulation can be
used if the a/c system has a SEER rating of 14 or more.
*RANGE /DRYER DUCT MUST COMPLY WITH 2009 IMC
*PROVIDE SANITARY FACILITIES /PORTA -CAN FOR WORKERS ON SITE
LOCATED OFF THE PUBLIC RIGHT -OF -WAY.
*ALL TRASH AND DEBRI GENERATED ON THE JOB SITE SHALL BE
PICKED UP AND CONTAINED IN AN APPROVED AREA WITHIN THE
PROPERTY BOUNDARIES.
*PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
A FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
*SHOWERS AND TUB /SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
*ALL SILLS AND BOTTOM PLATES IN CONTAC WITH CONRETE MUST BE
BUILDING DEPT REPRESENTATIVE:
APPLICANT _ �,(1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764 -3570 FAX: (979)764 -3496
http: / /bpinspect.cstx.gov
Page 6
Application Number 11- 00000505 Date 3/02/11
Special Notes and Comments
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
*MAKE SURE THAT ALL GLAZING IN HAZARDOUS LOCATIONS INSTALLED
COMPLIES WITH SAFETY REQUIREMENTS OF SECTION R308 OF THE
(IRC)
*ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR PERMITS PRIOR TO WORK, & INSPECTIONS PRIOR TO
COVERING ANY WORK (979)764 -3570.
*If Shower has Tile Floor, then the Pan Liner Must Be
Inspected for Leaks by plugging the drain and filling with
water before tile work is done, a Special Inspection Should
be requested and performed at this time.
Other Fees IMPACT FEE AREA 97 -01 98.39
SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
Fee summary Charged Paid Credited Due
Permit Fee Total 502.00 502.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 848.39 848.39 .00 .00
Grand Total 1350.39 1350.39 .00 .00
BUILDING DEPT REPRESENTATIVE: T r
. ,i
APPLICANT: j /
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764 -3570 FAX: (979)764 -3496
Application Number 11- 00000507 Date 3/02/11
Property Address 4032 ROCKY VISTA DR
Property ID: 184100- 0503 -0190
Application type description TEMP POLE
Subdivision Name CASTLE ROCK PH 5
Property Use RESIDENTIAL
Property Zoning PLANNED DEVL DISTRICT
Application valuation . . . 113850
Owner Contractor
MAGRUDER HOMES LLC MAGRUDER HOMES, LLC
PO BOX 10551 P.O. BOX 10572
COLLEGE STATION TX 778420551 COLLEGE STATION TX 77842
(979) 324 -6682
Permit TEMP POLE PERMIT
Additional desc . GS
Permit pin number 762880
Permit Fee . . . 20.00
Issue Date . . . 3/02/11 Valuation . . . . 0
Other Fees TEMP ELECT POLE CONNECT 45.00
Fee summary Charged Paid Credited Due
Permit Fee Total 20.00 20.00 .00 .00
Other Fee Total 45.00 45.00 .00 .00
Grand Total 65.00 65.00 .00 .00
NC=1.917/ . ._
BUILDING DEPT REPRESENTATIVE: XieLa1"
APPLIC _ r-�