HomeMy WebLinkAboutRES2003-03513 301 SAPPHIRE DR BUILDING PERMITCity
of Colle e Station
�ORK
REQUEST
PAGE
_ 1_
REQ/JOB:-
-WF0476430 / 001 PROJECT:
REQUEST DATE:
11%26%PRINT 03
CREW:
PRINT TIME:
7:34;:46
SCHEDULE
DATES
LOCATION:
301 SAPPHIRE DR
03
77845
COMPLETION:
11/26/03
GEN. LOC:
COLLEGE STATION LOC ID: 198624
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
H L C HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY TYPE:
ROUT-INE
- -
_WORK
TEMP POLE PASSED -
TEMP POLE
PASSED
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department:
OT-CUSTOMER SERVICE
w
PREPARED 3/10/04, 11:58:19 INSPECTION TICKET PAGE 8
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/10/04
------------------------------------------------------------------------------------------------
ADDRESS . : 301 SAPPHIRE DR SUBDIV: STONE FOREST PH 3
CONTRACTOR H L C HOMES LLC PHONE (979) 696-9049
OWNER JOHNSON INVESTMENTS INC PHONE
PARCEL 585200-0304-0100
APPL NUMBER: 03-00003513 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/09/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
12/09/03 AP 12/09/2003 09:41 AM GCARRILLO
Slab Ground Installed
Strings On Setbacks O.K.
B115 01 1/08/04 TB BLDG, FRAMING TIME: 17:00
1/08/04 AP 01/07/2004 03:55 PM SSTANLEY
B130 01 1/09/04 TB BLDG, INSULATION TIME: 17:00
1/09/04 AP 01/08/2004 10:53 AM GCARRILLO
B125 01 3/1,0% Y BIBLDG, FINAL TIME: 17:00
63 �f a flees 03/10/2004 09:05 AM GCARRILLO
----------------------------------- CONTINUED ONTO NEXT PAGE-----------------------------------
�pu5e_ Loc
TQJ f'uA
JC'
BUILDING PERMIT
'
,O OLbEGE STATION -
CI Y.-1
— - -
- " '1-101 TEXAS AVE
COLLEGE STATION, TX 77840-
PHONE: (979)764-3570
----------------------------------------------------------------------------
FAX: (979)764-3496
Application Number
. . . . . 03-00003513 Date 11/24/03
Property Address .
. . . . . 301 SAPPHIRE DR
Property ID
. . 585200-0304-0100
# . _ .... . .
. . . . . R115955
_R
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . STONE FOREST PH 3
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 153000
Owner
Contractor
------------------------
JOHNSON INVESTMENTS
------------------------
INC H L C HOMES LLC
_PO --BOX 800 - --
_ LEON -COUCH
COLEMAN
TX 768340800 11990 OLD WELLBORN ROAD
COLLEGE STATION TX 77845
(979) 696-9049
------ Structure Information
SINGLE FAMILY -----
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2318.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 252.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
SS
Permit Fee . . . .
619.00 Plan Check Fee .00
Issue Date
11/24/03 Valuation . . . . 153000
Expiration Date
5/23/04
Qty Unit Charge Per Extension
BASE FEE 460.00
53.00 3.0000
THOU BLDG, VAL 100001-500000 159.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
__1101—TEXAS AVE—
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003513
Page 2
Date 11/24/03
Special Notes and Comments
PROVIDE ATTIC ACCESS -WITHIN 20 FEET -OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS).
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE _ _ _ - - - -
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY'.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
--------------------------- - -------------------------
U-4
BUILDING DEPT REYWSENTATIVE: 1
APPLICANT:
BUILDING_ PERMIT-
- - —
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Page
3
Application Number
. . . . . 03-00003513
Date
11/24/03
Other Fees . . .
. . . . . . SEWER TAP 4"
CITY INSTALL
350.00
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
-----------------
Charged Paid
---------- ---------- ----------
Credited
----------
Due
Permit Fee Total
619.00 619.00
.00
.00
Plan Check Total
.00 .00
.00
.00
Other Fee Total
750.00 750.00
.00
.00
Grand Total
1369.00 1369.00
.00
.00
0
-- - - - - - - - - - - - - - - - - -
BUILDING DE
APPLICANT:
v
TEMPORARY POLE--PERMIT-
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00003514 Date 11/24/03
Property Address
301 SAPPHIRE DR
Property ID -. -. . . . .
585200-0304-0100
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
STONE FOREST PH 3
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
JOHNSON INVESTMENTS INC
------------------------
H L C HOMES L_LC
-
- -PO BOX 800 _
LEON COUCH
COLEMAN TX 768340800
11990 OLD WELLBORN
ROAD
r
COLLEGE STATION
TX 77845
(979) 696-9049
----------------------------------------------------------------------------
Permit TEMP POLE
PERMIT
Additional desc SS
Permit Fee . . . . 20.00
Issue Date . . . . 11/24/03
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.0.0 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
City_
of Col _Station- -- -- -
— - - —
WORK ;QUEST
PAGE
1
REQ/JOB:
WF0475882 / 001 PROJECT:
REQUEST DATE:
11/24/03
PRINT DATE:
11/24/03
CREW:
PRINT TIME:
16:21:52
SCHEDULE
LOCATION:
301 SAPPHIRE DR
STTART:DATES
11/24/03
77845
COMPLETION:
11/24/03
GEN. LOC:
COLLEGE STATION LOC ID:
198624
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION ,- PRIORITY:
NORMAL
REQUESTOR:
-H L-C HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY WORK
TYPE:
ROUTINE
3/4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER
4" SEWER
Category
code CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department: OT-CUSTOMER SERVICE
-----------------------------------'=-------------------------------------------
-------------------------------------------------------------------------------
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION:.
- - Y Q BLOCK SUBDI`
-00 BUSINESS/OWNER NAME:
O� 1 l Q' CONTRACTOR/HOMEOWNER: L
CONTRACTOR ADDRESS:
ELECTRICIANIV
:c�
HVAC:
��v
'C1 ACCESSORY/STORAGE
Q ADDITION
t(• DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans
\ Req)
DESCRIPTION OF WORK:
STRUCTURE USE: A VAJ
Fw Ofte Use OWy
DATE: / / /aI /o3
APPLICATION # /03
TEMP POLE #
SEC/PH
PHONE!,
PHONE:
t PLUMBER: - CCI
1 GOOD CENTS (Residential only),
CLASS OF WORK
'LOCATION RE -ROOF (Tots
MOVING SHELL ONLY
NEW CONSTRUCTION SLAB ONLY
REMODEL/RENOVATION SWIMMING PO
HOMEOWNER ASSOC IATION/ARCH ITECTUAL
TEXAS ACCESSIBILITY STANDARD (TAS) PRC
VALUATION: $ i I (gyp
(Cost of Labor and Materials)
1I PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
k
SEWER TAP:
SIZE
® WATER TAP: 3�L�%
SIZE
OTHER TAP:
SIZE
JTEMP POLE f'
GARAGE TYPE: SINGLE
ATTACHED C
SIGNATURE OF APPLICANT:
° a
Official Use Only
C N 11 a�lo3
Plans Examiner
DESIGN REVIEW C
T REGISTRATION#
TOTAL AREA: 3
APPROVAL:
D AREA: 2, _31 &
NUMBER OF BEDROOMS: 7 N\
NUMBER OF BATHROOMS: -3
^�
INTERIOR WALL TYPE: '20( _511G
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE TRIPLE
ACHED [ ei RT F
Zoning Official
• .4
x
' s
4
•Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
9
Permit Number
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
Checked By/Date
-- TITLE: 301 Sapphire
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11/21/03
DATE OF PLANS: 11-21-03
COMPANY INFORMATION:
HLC Homes, Inc.
11990 Old Wellborn Rd. Suite #3
College Station, Texas 77836
COMPLIANCE: Passes
Maximum UA = 466
Your Home = 397
14.8% Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss
2236 30.0 0.0 78
Ceiling 2: Cathedral Ceiling (no attic)
54 19.0 0.0 3
Wall 1: Wood Frame, 16" o.c.
1838 13.0 0.0 127
Window 1: Metal Frame, Double Pane
290 0.650 189
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other ca ulations submitted with the permit
plication. The proposed building has been
designed to meet the requirements ' MECcheck rsion
Release lb.
4200.CC
Builder/Designer.
>>
Date rG�
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 11 /20/03
r
TITLE: 301 Sapphire
i
Bldg.
Dept.
Use I
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane, U-factor: 0.650
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed. '
Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
Materials'and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values and glazing U-values must be clearly marked on the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0. .
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric; or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
Ducts shall be supported every 10, feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 V or chilled fluids below 55 °F must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts
Circulating Mains and Runouts
Temperature ( F) Up to 1„
Up to 1.25"
1.5" to 2.0" Over 2"
170-180 0.5
1.0
1.5 2.0
140-160 0.5
0.5
1.0 1.5
100-130 0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Range F
2" Runouts 1" and Less 1.25" to 2"
2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5 1.5
2.0
Low Temperature
120-200
0.5
1.0 1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0 1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55,
0.5
0.5 0.75
1.0
and Brine `
'Below 40
1.0
1.0 1.5
1.5
NOTES TO FIELD (Building Department Use Only)