Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-03494 1058 WINDMEADOWS DR BUILDING PERMIT
V �`—: �� 4 City of College Station WORK REQUEST PAGE 1 REQ/JOB: WF0475027 / 001 PROJECT: REQUEST DATE:. 11/21/03 PRINT DATE: 11/21/03 CREW: PRINT TIME: 12:59:07 DUL SCHSTART LOCATION: 1058 WINDMEADOWS DR :DATES 11/21/03 77845 COMPLETION: 11/21/03 GEN. LOC: COLLEGE STATION LOC ID: 195838 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 411SWR 3/4"WTR, 411SWR Category code CS -CUSTOMER SERVICES CSCS Task cove: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE PREPARED 4/27/04, 12:02:38 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/27/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1058 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER' BCS DEVELOPMENT CO PHONE PARCEL 650730-0102-0270 APPL�NUMBER: 03-00003494 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/04/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 12/04/03 AP 12/04/2003 08:00 AM SSTANLEY AFTER 3:00 12/04/2003 04:52 PM MALFORD STRINGS ON SETBACKS OK - SLAB GROUND BACK LEFT SIDE B115 01 1/14/04 DS BLDG, FRAMING TIME: 17:00 1/14/04 AE 01/14/2004 08:51 AM MALFORD Did Not Fix Notes From Previous Inspections EX-3% P1 1/20/04 CH BLDG, INSULATION TIME: 17:00 �4 1/20/04 AP 01/20/2004 08:11 AM MALFORD B125 01 4/27/0 BI BLDG, FINAL TIME: 17:00 7 04/27/2004 10:07 AM GCARRILLO Oq --------- —-------------H------ COMMENTS AND NOTES -------------------------- -- ------ BUILDING PERMIT C I TX., D.':,;, QQ1.a�F .,aTAT I -ON 1101 TEXAS AVE ` COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003494 Date 11/21/03 Property Address . . . . . . 1058 WINDMEADOWS DR Property ID . . 650730-0102-0270 R # . . . . . . . . . . . . . R113344 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 81312 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1232.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 388.00 Plan Check Fee .00 Issue Date . . . . 11/21/03 Valuation . . . . 81312 Expiration Date . . 5/20/04 Qty Unit Charge Per Extension BASE FEE 260.00 32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT --------------------------- - - ----- --------------- BUILDING DEPT DEPT REPRESENTATIVE: APPLICANT: " Pi',g BUILDING PERMIT CITY OF COLLEGE STATIOD 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003494 Date 11/21/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 ------------------------------- - ---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003494 Date 11/21/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 388.00 388.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1138.00 1138.00 .00 .00 ------------------------------------- BUILDING DEPT REPRESE�NTTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . Property Address . . . Property ID R# . . . . . . . . . . Tenant nbr, name . . . Application description Subdivision Name . . . Property Use . . . . . Property Zoning . . . . Application valuation . . . . 03-00003495 Date 11/21/03 . . . 1058 WINDMEADOWS DR 650730-0102-0270 R113344 . . . TEMP POLE TEMP POLE WESTFIELD VILLAGE PH 1 . . . RESIDENTIAL . . . PLANNED DEVL HOUSING 0 Owner Contractor ------------------------ ------------------------ BCS DEVELOPMENT CO STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc MA Permit Fee 20.00 Issue Date 11/21/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 Credited Due -------------------- .00 .00 .00 .00 .00 .00 ------------------------------------------- ---- ---- ---------------- BUILDING DEPT REPRESENTATIVE - APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: 1 U S � Far ORke Use Only DATE: APPLICATION # TEMP POLE # .1 LOT �7 BLOCK ,- SUBDIVISION W(-51 C�f Ia Vf 1Itij e PHASE BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbina HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sin le Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ S, ( � I J- TOTAL AREA: HEATEDAREA: 3 (Cost of La or and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �X SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE �X WATER TAP: 3/" EXTERIOR WALL TYPE: Siding and/or Masonry SIZE OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE �X TEMP POLE ROOF TYPE: Composition GARAGE TYPE: SINGLE F__] DOUBLE © TRIPLE ATTACHEDX� DETACHED F__] CARPORT SIGNATURE OF APPLICANT: For Stylecraft Official Use Only Comments: YES or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 10 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12