Loading...
HomeMy WebLinkAboutRES2003-03490 4206 CONWAY CT BUILDING PERMITPREPARED 3/18/04, 7:34:52 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/18/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 4206 CONWAY CT SUBDIV: CASTLEGATE SEC 9 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER STYLECRAFT BUILDERS INC PHONE PARCEL 184200-0902-0350 APPL NUMBER: 03-00003490 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/15/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 12/15/03 AP 12/15/2003 10:45 AM MALFORD late today 12/15/03 Strings On Setbacks O.K. Slab Ground Installed B115 01 1/22/04 TB BLDG, FRAMING TIME: 17:00 1/23/04 CA O1/20/2004 12:04 PM GCARRILLO B115 02 1/26/04 TB BLDG, FRAMING TIME: 17:00 1/27/04 AP O1/26/2004 12:42 PM GCARRILLO B130 01 1/29/04 TB BLDG, INSULATION TIME: 17:00 1/29/04 AP O1/28/2004 01:58 PM MALFORD B125 01 3/18/04 BI BLDG, FINAL TIME: 17:00 /a3&o 03/17/2004 04:18 PM SSTANLEY I� -------------------------------------- COMMENTS AND NOTES-------------------------------------- kCA IJAW-- T Y" 5j �O V\ 04-15W t1\45 i City of College Station WORD ?QUEST PAGE 1 REQ/JOB: WF0475025 / 001 PROJECT: REQUEST DATE: 11/21/03 PRINT DATE: 11/21/03 CREW: PRINT TIME: 12:57:43 SCHEDULE LOCATION: 4206 CONWAY CT STTART:DATES 11/21/03 77845 COMPLETION: 11/21/03 GEN. LOC: COLLEGE STATION LOC ID: 196044 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 411SWR 3/4"WTR, 411SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE City of Collegqe Station WORF :QUEST REQ/JOB: WF0476429 / 001 CREW: LOCATION: 4206 CONWAY CT PAGE 1 PROJECT: REQUEST DATE: 11/26/03 PRINT DATE: 11/26/03 PRINT TIME: 7:30:40 E BAT ES START: 11/26/03 77845 COMPLETION: 11/126/03 GEN. LOC: COLLEGE STATION LOC ID: 196044 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TEMP POLE PASSED Category code Task code: Facility ID . Assigned Department: CS -CUSTOMER SERVICES SET UP NEW UTILITY ACCT OT-CUSTOMER SERVICE CSCS SET REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\2402_4206 Conway Court.cck TITLE: Plan # 2042-CG CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11/19/03 DATE OF PLANS: 11-19-2003 PROJECT INFORMATION: SPEC 4206 Conway Court College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 678 Your Home UA = 599 11.7% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Skylight 1: Metal Frame:Double Pane with Low-E Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1904 30.0 0.0 66 16 0.670 11 138 19.0 0.0 7 1619 13.0 0.0 107 255 0.670 171 38 0.500 19 18 0.440 8 202 0.0 210 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchec,� and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer �"''(,-t 4 , Date l �" t / � 3 r REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 11 / 19/03 TITLE: Plan # 2042-CG Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes ' Frame Type Thermal Break? [ ] Yes [ ] No Comments:1 Skylights: [ ] 1. Skylight 1: Metal Frame:Double Pane with Low-E, U-factor: 0.670 For skylights without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments:, Doors: [ ] 1. Door 1: Solid, U-factor: 0.500 Comments: [ ] 2. Door 2: Glass, U-factor: 0.440 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed OA. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: 13 Assembly Type;=Mjoj��MMM Comments/ Description Window Area Total: 255.17 11 /19/03 11:37:13 1 /1 Area Calculator: Skylight Name Assembly Type Comments/ Description 11 /19/03 11:37:14 Skylight Area Total: 16.00 1/1 Area Calculator: Assembly Type Comments/ I Description Door Area Total: 55.56 11 /19/03 11:37:14 1 /1 Area Calculator: Assembly Type �©jjjM6j� �-M .. m �■�■�■� m �■�■�� Ceiling Area Total: 2042.00 11 /19/03 11:37:15 1 /1 Area Calculator: Assembly Type Comments/Description Exterior Wall Area Total: 1619.33 11 /19/03 11:37:16 1 /1 Area Calculator: Assembly Type Mimi .. :' _ Comments/Description Floor Area Total: 0.00 11 /19/03 11:37:16 1 /1 • BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003490 Date 11/21/03 Property Address . . . . . . 4206 CONWAY CT Property ID . . 184200-0902-0350 R # . . . . . . . . . . . . . R113136 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 134772 Owner Contractor ------------------------ STYLECRAFT BUILDERS INC ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 778458964 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2042.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 566.00 Plan Check Fee .00 Issue Date . . . . 11/21/03 Valuation . . . . 134772 Expiration Date . . 5/20/04 Qty Unit Charge Per Extension BASE FEE 461.00 35.00 3.0000 THOU BLDG, VAL 100001-500000 105.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT -- BUILDING DEPT REPRESENTATIVE:/ -------------------- - ------- --- - ----------------- APPLICANT: Q BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00003490 Date 11/21/03 ------------- 7---------------- 7--------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE•INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM,FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB•SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR,•TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPEREDIGLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechani`cal) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN' PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 -------- -------------------------- - ---- ------- -----7 - --------------- - -- BUILDING DEPT RREEPRESENTTAATIVE: APPLICANT: �.�'l BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003490 Date 11/21/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 566.00 ---------- 566.00 -------------------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1316.00 1316.00 .00 .00 ---------------------------------- - --- --------A-;-� --------------- BUILDING DEPT REPRESENTATIVE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID R# . . . . . . . . . . . Tenant nbr, name . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning Application valuation 03-00003491 4206 CONWAY CT 184200-0902-0350 R113136 TEMP POLE TEMP POLE CASTLEGATE SEC 9 RESIDENTIAL PLANNED DEVL HOUSING 0 Date 11/21/03 Owner Contractor ------------------------ STYLECRAFT BUILDERS INC ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 778458964 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 11/21/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: lLa 11 a Mll l oo APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 -1:(979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US DRESS/ OCATION: v Fm Office Use Only DATE: f k 7 2 APPLICATION # () 3 TEMP POLE -� LOT 3 S' BLOCK a"/ SUBDIVISION Ca t (e a re PHASE 1 BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 I CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690 1222 ext. 20 i CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTIONIOF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL. Pe� .� TEXAS ACCESSIBILITY STANDARD (TAS)/PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 134 77� - `7 TOTAL AREA: U 11 HEATED AREA: 10'4 (Cost of L bor and Materials) �X PUBLIC SEWER NUMBER OF BEDROOMS: El SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: ❑X SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE �X WATER TAP: 3/a" EXTERIOR WALL TYPE: Skiing and/Or Masonry SIZE OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE TEMP POLE ROOF TYPE: Composition GARAGE TYPE: SINGLE F__] DOUBLE ® TRIPLE ATTACHED FT] DETACHED F__1 CARPORT SIGNATURE OF APPLICANT: �i�—�-� For Stvlecraft Official Use Only ents: CN i 111a6 c3 YES r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 6 Insulation R value of exterior walls R13 / Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 / Glazing SHGC .40 / Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 `�