Loading...
HomeMy WebLinkAboutRES2003-03438 301 AGATE DR BUILDING PERMITYW two W e � , MECcheck Compliance Reporf 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: Plan # 2376 I CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11 / 11 /03 DATE OF PLANS: Oct'03 PROJECT INFORMATION: 301 Agate Dr. College Station, Texas 77845 COMPANY INFORMATION: ELH-Elegant Living Homes, Inc. P. O. Box 7063 Bryan, Texas 77845 NOTES: Please call when permit is ready: Bill 979-229-2045 Cindy 979-777-0703 Office 979-823-0638 Permit Number Checked By/Date COMPLIANCE: Passes Maximum UA = 535 Your Home = 415 22.4% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2376 0.0 30.0 74 Exterior Wall 1: Wood Frame, 16" o.c. 2003 13.0 0.0 132 Window: 3070: Other 147 0.600 88 Window: 1060: Other 12 0.600 7 Window: 6016: Other ' 9 0.600 5 Window: 6020: Other 12 0.600 7 Window: 3060: Other 108 0.600 65 Window: 3050: Other 30 0.600 18 Window: 4040: Other 16 0.600 ' 10 Door: 3/0: Solid 20 0.170 3 Door: 2/8: Solid 36 0.170 6 Air Conditioner 1: Electric Central Air, 12 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application: The proposed building has been 1 designed to meet the 2000 IECC requ' is in M Ccheck n 3.2 Release lb. Builder/Desigi r Date J l MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 11 / 11 /03 TITLE: Plan # 2376 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling ,1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: Above -Grade Walls: 1. Exterior Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window: 3070: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x T Window 2. Window: 1060: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes, Frame Type Thermal Break? [ ] Yes [ ] No Comments: F x 6' Window 3. Window: 6016: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panesi Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' xl'6" Transom Window 4. Window: 6020: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes, Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' x 2' Eyebrow 5. Window: 3060: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x 6' Window 6. Window: 3050: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x 5' Window 7. Window: 4040: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 4'x 4' OBSC SG Doors: 1. Door: 3%0: Solid, U-factor: 0.170 Comments: Y x 6' 8" Fiberglass Door 2. Door: 2/8: Solid, U-factor: 0.170 Comments: 2'8" x 6'8" Door 3 i Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Centra[Air, 12 SEER or higher Make and Model Number, [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordint to the manufacturer's installation instructions. [ ] Materials and'equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing'U-values, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: + [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside'the building must be insulated to R-8.0. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be; supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ductswith exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. 1 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) City of College Station WORK REQUEST PAGE RIEQ/JOB: WF0475024 / 001 PROJECT: REQUEST DATE: 11/21/03 PRINT DATE: 11/21/03 CREW: PRINT TIME: 12:57:14 SCHSTTART:EDULEDATES LOCATION: 301 AGATE DR 11/21/03 1 77845 COMPLETION: 11/21/03 GEN. LOC: COLLEGE STATION LOC ID: 195126 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, 4"SWR 3/4"WTR, 4"SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE PREPARED 2/20/04, 15:12:38 INSPECTION TICKET PAGE 1 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: OSCAR CHAVARRIA JR DATE 2/20/04 ADDRESS . : 301 AGATE DR SUBDIV: STONE FOREST PH 2 CONTRACTOR ELEGANT LIVING HOMES PHONE (979) 823-0638 OWNER JOHNSON INVESTMENTS INC PHONE PARCEL 585200-0206-0450 APPL NUMBER: 03-00003438 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/05/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 12/05/03 AP 12/05/2003 12:08 PM SSTANLEY form survey & strings pulled slab ground back left B115 01 12/31/03 TB BLDG, FRAMING TIME: 17:00 12/31/03 AP 12/31/2003 09:59 AM SSTANLEY B130 01 1/06/04 OC BLDG, INSULATION TIME: 17:00 1/06/04 AP 01/05/2004 01:15 PM MALFORD B125 01 2/ 0/04 a �°10Y Or— BLDG, FINAL TIME: 17:00 I►V 02/20/2004 03:11 PM GCARRILLO -------------------------------------- COMMENTS AND NOTES -------------------------------------- ifr64q-IIe(Q �� 8 City of College Station%'-. WORK" REQUEST' " " ' PAGE 1 r REQ/JOB: WF04'75615 / 001 PROJECT: REQUEST DATE: 11/24/03 PRINT DATE: 11 24/Q3 CREW: PRINT TIME: 7:54:44 SCHEDULE DATES LOCATION: 3011AGATE DR START: 11/24/03 1 177845 COMPLETION: 11/24/03 GEN. LOC: COLLEGE STATION LOC ID: 195126 1 , REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED ------------------------------------- TEMP POLE PASSED Category code `. CS -CUSTOMER SERVICES CSCS i Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE I. BUILDING PERMIT '--TTTY"'nP"'"=7L13GE� STATION * COLLEGE STATION, TX 77840 PHONE: (979) 764.-3570 FAX: (979) 764-3496 I ----------------------------------------------=----------------------------- Application Number 03-00003438 Date 11/21/03 * Property Address . . . . . . 301 AGATE DR Property 'ID . . 585200-0206-0450 R # .' . .1 . . • • • • • . . . R112580 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . STONE FOREST°PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE.FAMILY RESIDENTIAL Appl'ication valuation . . . . 156816 Owner Contractor -----------------------= JOHNSON INVESTMENTS INC ------------------------ ELEGANT LIVING HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN r TX 768340800 PO BOX 7063 BRYAN TX 77805- (979) 823-0638 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy,Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID '-NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2376.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 -------- ----`---------7------------------ Permit .1. . . . . BUILDING -------------------------------------- PERMIT Additional desc . . MR Permit Fee . . . . 631.00 Plan Check Fee .00 Issue Date 11/21/03 Valuation . . . . 156816 Expiration Date 5/20/04 9 Qty Unit Charge Per' Extension': BASE FEE 460.00 57.00 3.0000 THOU BLDG, VAL 100001-500000 171.00 ---------- =-----------------------------------------------------------------. Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT l' -------------------- BUILDING DE APPLICANT: 8 BUILDING PERMIT CITY OF COLLEGE STATION I 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE:, (979) 764-3570 FAX: (979) 764-3496 ----------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00003438, Date 11/21/03 ------=--------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER117, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S ) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION,SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION`DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL,RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER• PENETRATIONS SEALED PLATFORM FOR MECHANICAL,EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED,,PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS,THE MAXIMUMISTATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area�of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be,used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND , EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED,GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALf PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST -BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES BUILDING DI APPLICANT: F BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003438 Date 11/21/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged ---------- Paid ---------- Credited -------------------- Due` ----------------- Permit Fee Total 631.00 631.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1381.00 1381.00 .00 .00 -------------- ----- BUILDING 'DF APPLICANT: : TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: -------------- '--------------------------_----------------------------------- (979)764-3570 FAX: (979)764-3496 1 Application Number . . . . . 03-00003439 Date 11/21/03 Property Address . . . . . 301 AGATE DR Property ID . . 585200-0206-0450 R # . . . . . . . . . . . . . R112580 Tenant nbr, name . . . . . . TEMP POLE Application description . . . TEMP POLE Subdivision Name . . . . . . STONE.FOREST PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ -7 ---------------------- JOHNSON INVESTMENTS INC ELEGANT LIVING_HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN TX 768340800 PO BOX 7063 BRYAN TX 77805 (979) 823-0638 --------------'-------------------------------------------------------------- 'Permit . . . . . . TEMP POLE PERMIT Additional desc . .. MR { Permit Fee . . . . 20.00 Issue Date . . . =---------------------------- . 11/21/03 Valuation . . . . 0 ------------- Other Fees . . . 7-------- 7------------------------- . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged Paid Credited ---------------------------------------- Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: I APPLICANT: For Ofte Us Only APPLICATION' FOR BUILDING PERMIT onrE: ` D�' ' CITY OF COLLEGE STATION' = APPLICATION #Ls 1: 1101 TEXAS AVENUE 1' COLLEGE STATION, TX 77846 TEMP POLE #. (979) 764-3570 (679) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX:US ADDRESS/LOCATION: 36 1 r•` Cok% e e. ' 5+n- 4h a i ; "Tx, �.? +S LOT1+ BLOCK �,. SUBDIVISION Siam rc h S BUSINESS%OWNER NAME: F,(' -i-'LPHONE: C1"1C1-&2_5.0(o312 \, '4 CONTRACTOR/HOMEOWNER: PHONE:. o�U.�►'►�- '7 CONTRACTOR ADDRESS: ��` C7 2� 0 i� % O 5o 3 � a✓1. �Tx 'ELECTRICIAN:` l:z I ( eAt E44Ity G e-4. PLUMBER: i-i' '>A - I k►�101 IrLI� HVAC: �d� ft5 '� C �� GOOD CENTS (Residential only): j CLASS OF'WORK = " ACCESSORY/STORAGE' LOCATION RE -ROOF- jotal/Paftial) -ADDITION MOVING' SHELL ONLY. ` DEMOLITION,(Asbestos Survey) NEW, CONSTRUCTION,,,SLAB•ONLY DUPLEX+(Landscape Plans Req) , , REMODEL/RENOVATION,.: SWIMMING POOL. DESCRIPTION OF WORK: CInsiiZ. L+L- ryA : off. hew 11/LG)1 e VYI ly STRUCTURE USE: LCt HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN'REVIEW COMMITTEE APPROVAL: I eS -TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT,REGIST RATION# EABPRJ ' " ' { VALUATION: $. y I1�-��-- • ` , TOTAL'AREA: ?5&1+0 HEATED AREA:: a 37(o (Cost of Labor and Materials) PUBLIC'SEWE'R ,: ! pj ``� NUMBER OF BEDROOMS: , SEPTIC/TREATMENT SYSTEM ,NUMBER"OF BATHROOMS: Z I�Z ® SEWER TAP: �.INTERIOR WALL TYPE: - s ( tck SIZE ® WATER TAP:: 1 ' EXTERIOR WALL TYPE: SIZE' .OTHER TAP: ,FOUNDATION TYPE:i SIZE Li TEMP POLE ROOF -TYPE: �mQOS�Ti Ulr1 GARAGE TYPE: SINGLE a DOUBLE' a "' TRIPLE " a . ATTACHED :D:E�TACHE CARP T SIGNATURE OF APPLICANT. Official Use Only ents: , le, N � L1 I a3, - •. ES r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 11P.�1 Insulation •R value of exterior walls Insulation1R value of,ceiling- I-, (flat, areas)` 3d �. y ^Insulation R value'of-cciling 2 (vaulted-areas/no attic), n(c� Glazing SHGC .3(p Glazing U-Factor. • R value of ductwork Co A/C SEER rating 12