HomeMy WebLinkAboutRES2003-03438 301 AGATE DR BUILDING PERMITYW
two
W
e � ,
MECcheck Compliance Reporf
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: Plan # 2376
I
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11 / 11 /03
DATE OF PLANS: Oct'03
PROJECT INFORMATION:
301 Agate Dr.
College Station, Texas 77845
COMPANY INFORMATION:
ELH-Elegant Living Homes, Inc.
P. O. Box 7063
Bryan, Texas 77845
NOTES:
Please call when permit is ready:
Bill 979-229-2045
Cindy 979-777-0703
Office 979-823-0638
Permit Number
Checked By/Date
COMPLIANCE: Passes
Maximum UA = 535
Your Home = 415
22.4% Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss
2376
0.0 30.0
74
Exterior Wall 1: Wood Frame, 16" o.c.
2003
13.0 0.0
132
Window: 3070: Other
147
0.600
88
Window: 1060: Other
12
0.600
7
Window: 6016: Other '
9
0.600
5
Window: 6020: Other
12
0.600
7
Window: 3060: Other
108
0.600
65
Window: 3050: Other
30
0.600
18
Window: 4040: Other
16
0.600 '
10
Door: 3/0: Solid
20
0.170
3
Door: 2/8: Solid
36
0.170
6
Air Conditioner 1: Electric Central Air, 12 SEER
COMPLIANCE STATEMENT: The proposed building design
described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application: The proposed building has been
1
designed to meet the 2000 IECC requ' is in M Ccheck n 3.2 Release lb.
Builder/Desigi r Date J l
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 11 / 11 /03
TITLE: Plan # 2376
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling ,1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
1. Exterior Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1.
Window: 3070: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: Y x T Window
2.
Window: 1060: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes, Frame Type Thermal Break? [
] Yes [ ] No
Comments: F x 6' Window
3.
Window: 6016: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panesi Frame Type Thermal Break? [
] Yes [ ] No
Comments: 6' xl'6" Transom Window
4.
Window: 6020: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes, Frame Type Thermal Break? [
] Yes [ ] No
Comments: 6' x 2' Eyebrow
5.
Window: 3060: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: Y x 6' Window
6.
Window: 3050: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: Y x 5' Window
7.
Window: 4040: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: 4'x 4' OBSC SG
Doors:
1. Door: 3%0: Solid, U-factor: 0.170
Comments: Y x 6' 8" Fiberglass Door
2. Door: 2/8: Solid, U-factor: 0.170
Comments: 2'8" x 6'8" Door
3
i
Heating and Cooling Equipment:
[ ] 1. Air Conditioner 1: Electric Centra[Air, 12 SEER or higher
Make and Model Number,
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
[ ] Materials and'equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing'U-values, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation: +
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside'the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
Ducts shall be; supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ductswith exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2. 1
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating Mains and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0" Over 2"
170-180
0.5
1.0
1.5 2.0
140-160
0.5
0.5
1.0 1.5
100-130
0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
City of College Station
WORK REQUEST PAGE
RIEQ/JOB:
WF0475024 / 001 PROJECT:
REQUEST DATE:
11/21/03
PRINT DATE:
11/21/03
CREW:
PRINT TIME:
12:57:14
SCHSTTART:EDULEDATES
LOCATION:
301 AGATE DR
11/21/03
1
77845 COMPLETION:
11/21/03
GEN. LOC:
COLLEGE STATION LOC
ID: 195126
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
ELEGANT LIVING HOMES
ORIGIN: CUSTOMER -WALK
IN
USER ID:
MRODGERS AUTH: MRODGERS
WORK TYPE: ROUTINE
3/4"WTR,
4"SWR
3/4"WTR, 4"SWR
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
PREPARED
2/20/04, 15:12:38
INSPECTION TICKET PAGE 1
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: OSCAR CHAVARRIA JR DATE 2/20/04
ADDRESS
. : 301 AGATE DR
SUBDIV: STONE FOREST PH 2
CONTRACTOR ELEGANT LIVING HOMES
PHONE (979) 823-0638
OWNER
JOHNSON INVESTMENTS
INC PHONE
PARCEL
585200-0206-0450
APPL NUMBER: 03-00003438 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
12/05/03 CH
BLDG, FOUNDATION -SLAB TIME: 17:00
12/05/03 AP
12/05/2003 12:08 PM SSTANLEY
form survey & strings pulled
slab ground back left
B115 01
12/31/03 TB
BLDG, FRAMING TIME: 17:00
12/31/03 AP
12/31/2003 09:59 AM SSTANLEY
B130 01
1/06/04 OC
BLDG, INSULATION TIME: 17:00
1/06/04 AP
01/05/2004 01:15 PM MALFORD
B125 01
2/ 0/04
a �°10Y Or—
BLDG, FINAL TIME: 17:00
I►V
02/20/2004 03:11 PM GCARRILLO
-------------------------------------- COMMENTS AND NOTES --------------------------------------
ifr64q-IIe(Q
�� 8
City of College Station%'-.
WORK" REQUEST' " " ' PAGE 1
r
REQ/JOB: WF04'75615 / 001 PROJECT: REQUEST DATE: 11/24/03
PRINT DATE: 11 24/Q3
CREW: PRINT TIME: 7:54:44
SCHEDULE DATES
LOCATION: 3011AGATE DR START: 11/24/03
1 177845 COMPLETION: 11/24/03
GEN. LOC: COLLEGE STATION LOC ID: 195126
1 , REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
TEMP POLE PASSED
-------------------------------------
TEMP POLE PASSED
Category code `. CS -CUSTOMER SERVICES CSCS
i Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
I.
BUILDING PERMIT
'--TTTY"'nP"'"=7L13GE� STATION
* COLLEGE STATION, TX 77840
PHONE: (979) 764.-3570 FAX: (979) 764-3496
I
----------------------------------------------=-----------------------------
Application Number
03-00003438
Date 11/21/03
* Property Address . . .
. . . 301 AGATE DR
Property 'ID
. . 585200-0206-0450
R # .' . .1 . . • • • • •
. . . R112580
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . STONE FOREST°PH 2
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . SINGLE.FAMILY RESIDENTIAL
Appl'ication valuation .
. . . 156816
Owner
Contractor
-----------------------=
JOHNSON INVESTMENTS INC
------------------------
ELEGANT LIVING HOMES
PO BOX 800
WILLIAM C MORRIS
COLEMAN r TX
768340800 PO BOX 7063
BRYAN
TX 77805-
(979) 823-0638
------ Structure Information
SINGLE FAMILY
-----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy,Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
'-NA
FOUNDATION TYPE
CONCRETE
NUMBER OF GARAGE BAYS
2.00
HEATED AREA
2376.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
252.00
--------
----`---------7------------------
Permit .1. . . . . BUILDING
--------------------------------------
PERMIT
Additional desc . . MR
Permit Fee . . . .
631.00 Plan Check Fee
.00
Issue Date
11/21/03 Valuation . .
. . 156816
Expiration Date
5/20/04
9
Qty Unit Charge Per' Extension':
BASE FEE 460.00
57.00 3.0000 THOU BLDG, VAL 100001-500000 171.00
---------- =-----------------------------------------------------------------.
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
l'
--------------------
BUILDING DE
APPLICANT:
8
BUILDING PERMIT
CITY OF COLLEGE STATION
I 1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:, (979) 764-3570 FAX: (979) 764-3496
-----------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00003438, Date 11/21/03
------=---------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER117, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S )
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION,SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION`DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL,RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER•
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL,EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED,,PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS,THE
MAXIMUMISTATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area�of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be,used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND ,
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED,GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALf PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
-BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
BUILDING DI
APPLICANT:
F
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00003438
Date
11/21/03
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
SEWER TAP 4"
CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary
Charged
----------
Paid
----------
Credited
--------------------
Due`
-----------------
Permit Fee Total
631.00
631.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1381.00
1381.00
.00
.00
-------------- -----
BUILDING 'DF
APPLICANT:
:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
-------------- '--------------------------_-----------------------------------
(979)764-3570 FAX: (979)764-3496
1
Application Number
. . . . . 03-00003439 Date
11/21/03
Property Address
. . . . . 301 AGATE DR
Property ID
. . 585200-0206-0450
R # . . . . . . .
. . . . . . R112580
Tenant nbr, name
. . . . . . TEMP POLE
Application description . . . TEMP POLE
Subdivision Name
. . . . . . STONE.FOREST PH 2
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------ -7 ----------------------
JOHNSON INVESTMENTS INC ELEGANT LIVING_HOMES
PO BOX 800
WILLIAM C MORRIS
COLEMAN
TX 768340800 PO BOX 7063
BRYAN
TX 77805
(979) 823-0638
--------------'--------------------------------------------------------------
'Permit . . . . .
. TEMP POLE PERMIT
Additional desc .
.. MR
{ Permit Fee . . .
. 20.00
Issue Date . . .
=----------------------------
. 11/21/03 Valuation . . . .
0
-------------
Other Fees . . .
7-------- 7-------------------------
. . . . . . TEMP ELECT POLE CONNECT
45.00
Fee summary
-----------------
Charged Paid Credited
----------------------------------------
Due
Permit Fee Total
20.00 20.00 .00
.00
Other Fee Total
45.00 45.00 .00
.00
Grand Total
65.00 65.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
I
APPLICANT:
For Ofte Us Only
APPLICATION' FOR BUILDING PERMIT onrE: ` D�' '
CITY OF COLLEGE STATION' = APPLICATION #Ls
1:
1101 TEXAS AVENUE
1' COLLEGE STATION, TX 77846 TEMP POLE #.
(979) 764-3570 (679) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX:US
ADDRESS/LOCATION: 36 1 r•` Cok% e e. ' 5+n- 4h a i ; "Tx, �.? +S
LOT1+ BLOCK �,. SUBDIVISION Siam rc h S
BUSINESS%OWNER NAME: F,(' -i-'LPHONE: C1"1C1-&2_5.0(o312
\, '4 CONTRACTOR/HOMEOWNER: PHONE:. o�U.�►'►�-
'7 CONTRACTOR ADDRESS: ��` C7 2� 0 i� % O 5o 3 � a✓1. �Tx
'ELECTRICIAN:` l:z I ( eAt E44Ity G e-4. PLUMBER: i-i' '>A - I k►�101 IrLI�
HVAC: �d� ft5 '� C �� GOOD CENTS (Residential only):
j CLASS OF'WORK =
" ACCESSORY/STORAGE' LOCATION RE -ROOF- jotal/Paftial)
-ADDITION MOVING' SHELL ONLY.
`
DEMOLITION,(Asbestos Survey) NEW, CONSTRUCTION,,,SLAB•ONLY
DUPLEX+(Landscape Plans Req) , , REMODEL/RENOVATION,.: SWIMMING POOL.
DESCRIPTION OF WORK: CInsiiZ. L+L- ryA : off. hew 11/LG)1 e VYI ly
STRUCTURE USE: LCt
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN'REVIEW COMMITTEE APPROVAL: I eS
-TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT,REGIST RATION# EABPRJ ' "
' { VALUATION: $. y I1�-��-- • ` , TOTAL'AREA: ?5&1+0 HEATED AREA:: a 37(o
(Cost of Labor and Materials)
PUBLIC'SEWE'R ,: ! pj ``� NUMBER OF BEDROOMS: ,
SEPTIC/TREATMENT SYSTEM ,NUMBER"OF BATHROOMS: Z I�Z
® SEWER TAP: �.INTERIOR WALL TYPE: - s ( tck
SIZE
® WATER TAP:: 1 ' EXTERIOR WALL TYPE:
SIZE'
.OTHER TAP: ,FOUNDATION TYPE:i
SIZE Li
TEMP POLE ROOF -TYPE: �mQOS�Ti Ulr1
GARAGE TYPE: SINGLE a DOUBLE' a "' TRIPLE " a
. ATTACHED :D:E�TACHE CARP T
SIGNATURE OF APPLICANT.
Official Use Only
ents:
, le, N � L1 I a3, - •. ES r NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 11P.�1
Insulation •R value of exterior walls
Insulation1R value of,ceiling- I-, (flat, areas)` 3d �. y
^Insulation R value'of-cciling 2 (vaulted-areas/no attic), n(c�
Glazing SHGC .3(p
Glazing U-Factor.
• R value of ductwork Co
A/C SEER rating 12