HomeMy WebLinkAboutRES2003-03400 3523 MYTH LN BUILDING PERMITPREPARED 5/27/04, 8:42:48 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/27/04
------------------------------------------------------------------------------------------------
ADDRESS . : 3523 MYTH LN SUBDIV: HERITAGE TOWNHOMES
CONTRACTOR T C CUSTOM HOMES PHONE (979) 774-1110
OWNER HAUSMAN INTERESTS TOWNHOMES PHONE
PARCEL 320500-0002-0110
APPL NUMBER: 03-00003400 RESIDENTIAL, 1 UNIT ATTACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/10/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/10/03 AP 12/10/2003 08:10 AM SSTANLEY
B1 01 3/09/04 DP BLDG, FRAMING TIME: 17:00
3/16/04 AP 03/08/2004 12:53 PM GCARRILLO
B125 01 5/27/0��4G � BLDG, FINAL TIME: 17:00
7 05/27/2004 08:42 AM GCARRILLO
--------------------------------- COMMENTS AND NOTES --------------------------------------
�ar�al��// rv„
lavo pum'ki
Mandi Alford- Insulation request inspecl' esult, 3523 Myth #03-3400 Page 1
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 4/2/2004 9:02:41 AM
Subject: Insulation request inspection result, 3523 Myth #03-3400
Print for File
Inspected insulation, 3523 Myth #03-3400, TC Custom Homes 4-2-04
Inspection result: Inspected OK for Good Cents
Notes:
Duct out master bath exhaust fan.
remove OSB from attic before insulation.
CC: Alford, Mandi
City
of College
Station
']QUEST
WORK
PAGE
1
REQ/JOB:
WF0474558
/;-,u01 PROJECT:
'°
REQUEST DPRINT ATE:
11%20%03
CREW:
PRINT TIME:
9:00:16
SCHEDULE
LOCATION:
3523 MYTH
LN
STTART:DATES
11/20/03
77845
COMPLETION:
11/20/03
GEN. LOC:
COLLEGE
STATION LOC ID:
192498
'
REF NBR:
REQ DEPT:
DE -BUILDING
INSPECTION PRIORITY:
NORMAL
REQUESTOR:
HERITAGE
TOWNHOMES. ORIGIN:
CUSTOMER -WALK
IN
USER ID:
GCARRILLO
AUTH: GCARRILLO WORK
TYPE:
ROUTINE
SWR 4"
-------------------------------------------------------------------------------
WTR 3/4"
SWR 4" WTR
3/4"
Category
code'. .
CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department:
----------------=--------------------------------------------------------------
-------------------------------------------------------------------------------
OT-CUSTOMER SERVICE
City"�of College `Station
1101 TEXAS AVENUE `'
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
6/03/04
320500-0002-0110
3523 MYTH LN
COLLEGE STATION TX 77845
HERITAGE TOWNHOMES
HERITAGE TOWNHOMES, BLOCK 2, L
OT 11
UNKNOWN
HAUSMAN INTERESTS TOWNHOMES
Contractor . . . . . . T C CUSTOM HOMES
979 774-1110
Application number 03-00003400 000 000
Description of Work RESIDENTIAL, 1 UNIT ATTACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved . . . . . . .
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
1 BUILDING PERMIT r�
k, 1-
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
Property,Address . . .
Property ID
Application description
Subdivision Name . . .
Property Use . . . . .
Property Zoning . . . .
Application valuation .
. . . 03-00003400 Date 11/20/03
. . . 3523 MYTH LN
. . 320500-0002-0110
. . . R110702
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
. . . HERITAGE TOWNHOMES
. . . RESIDENTIAL
. . . SINGLE FAMILY RESIDENTIAL
149900
Owner Contractor
HAUSMAN INTERESTS TOWNHOMES T,C CUSTOM HOMES
LTD
TODD CARNES
1328 SOUTH LOOP W STE
100 230 SOUTHWEST PARKWY E
HOUSTON
TX 770544008 COLLEGE STATION
TX 77840
(979) 774-1110.
------ Structure Information
TOWNHOUSE
-----
'Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
HEATED AREA
1790.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.50
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
SERIAL ZONES
238.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GC
Permit Fee . . . .
610.00 Plan Check Fee
.00
Issue Date . . . .
11/20/03 Valuation . . .
. 149900
Expiration Date . .
5/19/04
Qty Unit Charge
Per
Extension
BASE FEE
460.00
50.00 3.0000
THOU BLDG, VAL 100001-500000
150.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-- - - - - - - - - - - - - - - - - - - - - - -
BUILDING DEPT RE
1
APPLICANT: C
BUILDING PERMIT
CITY OF ,COLLEGE STATIOP
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003400
Special Notes and Comments
PROVIDE�COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
Page 2
Date 11/20/03
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE:EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE tNGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN.ISPRINKLER IS PROVIDED, PERMIT MUST'BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM,STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds d5% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE.STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLiS AND BOTTOM PLATES'IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION
1003.3.3 (2000 IBC) AS APPROPRIATE
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIOP
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number
. . . . .
03-00003400
Date 11/20/03
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
-----------------
Charged
Paid Credited
Due
Permit Fee Total
----------
610.00
--------------------
610.00
.00
----------
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1360.00•
1360.00
.00
.00
-------- CAW ----------------------------
BUILDING DEPT R R/EJSnEnNTA VE :VW-
j
j I
'for OIPro
-APPLICATION'F.OR BUILDING PERMI : 1; 'DATE:
CITY OF COLLEGE STATION " . y.
A 101, TEXAS AVENUE APPLICATION #
.. 4' COLLEGE STATION, TX 77840 TEMP POLE #,
t•
(97\9) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEG ESTATION.TX.US:.
,.ADDRESS/LOCATION:
LOT BLOCK _ SUBDIVISION
BUSINESS/OWNER NAME: PHONE: 10 1 3��3�j
CONTRACTOR/HOMEOWNER: � '��j PHONE: liTl ✓`�^
CONTRACTOR ADDRESS: Y
2� ��-Inv�>� a k�Na�l : f6� o��C
�v PLUMBER:
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE _ LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Reg)`` R ODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
,STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P,I�OJECT REGISTRATION# EABPRJ
VALUATION: $ 100 TOTAL AREA: Z210 S HEATED AREA:1`]g�
(Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPI IC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
EVSEWER TAP: INTERIOR WALL TYPE:
*ATER'TAP: /! EXTERIOR WALL TYPE:.
SIZE _
El OTHER TAP: FOUNDATION TYPE: Gag
S¢E
TEMP POLE ROOF TYPE:. 66M12
GARAGE TYPE: SINGLE` DOUBLE TRIPLE a
ATTACHED MCHED,. 0 CARPORT a
SIGNATURE 'OF APPLICANT:
Official Use Only`
� • ', YES or NO -
Plans Examiner Zon'ing'Ocial
't., .: yip• ':{:. - - 't•s"�:S'r
+}•
l: 1. - \ - .. -• " :t l - - I
" c"i ,.k
•r ?,. ..
' Energy!-Code_Vompliance In
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value -of ceiling 2 (vaulted areas/no attic).{
Glazing SHGC
p �o
Glazing U-Factor
R value of ductwork
A/C SEER rating
r
-
•
i'
i
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release 1
Data filename: CADocuments\New Folder\tc-unit-K.rck
TITLE: Unit K
CITY: Bryan (Brazos County)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 02/19/03
DATE OF PLANS: 02-18-03
PROJECT INFORMATION:
Heritage Town Homes
COMPANY INFORMATION:
T.C. Custom Homes
College Station, Texas
(979)693-7835
NOTES:
This REScheck report was generated by R.A.I.:
John Rhodes
P.O. Box 9389
College Station, Texas 77842
(979) 412-5066
COMPLIANCE: Passes
Maximum UA = 739
Your Home UA = 485
34.4% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
First F1oorCeiling 1: Flat Ceiling or Scissor Truss
Second Floor Ceiling 2: Flat Ceiling or Scissor Truss
First floor Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Door 1: Solid
Door 2: Glass
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
626
30.0
0.0
22
572
30.0
0.0
20
1386
13.0
0.0
98
131
0.650
85
38
0.350 •
13
18
0.650
12
a
SHGC: 0.40 1
Second Floor Wall 2: Wood Frame, 16" o.c. 920 13.0 0.0 75
Floor 1: Slab -On -Grade: Unheated 154 0.0 160
Insulation depth: 0.0'
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The'proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release 1 (formerly MECchecl and to comply with the mandatory requirements listed in the
REScheckInspection Chec ist.
M
Builder/Designer — Date
r �
REScheck Inspection Checklist
2000 IECC
RES check Software Version 3.5 Release 1
DATE:02/19/03 i
TITLE: Unit K
Bldg.
Dept.
Use
Ceilings:
[ ] 1. First F1oorCeiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Second Floor Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. First floor Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
[ ] 2. Second Floor Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650
For windows without labeled U-factors, describe features:
# Panes ! Frame Type Thermal Break? [ ) Yes [ ) No
Comments:
Doors:
[ ] L , Door 1: Solid, U-factor: 0.350
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.650
Comments:
Floors:
[ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
[ ] 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure_ or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be 'sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
i
Materials Identification:
[ ] , Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ,] Ducts in unconditioned spaces must be insulated to R-5.
•Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water,Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in,Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
_ 'of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts
Circulating Mains and Runouts
Temperature ( F) Up to 1„
Up to 1.25"
1.5" to 2.0" Over 2"
170-180 0.5
1.0
1.5 2.0
140-160 0.5
0.5
1.0 1.5
100-130 0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by Pipe
Sizes
Piping System Types
Range F
2" Runouts 1"and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
'
201-250
1.0 1.5 1.5
2.0
Low Temperature
120-200
0.5 1.0 1.0
1.5
Steam Condensate (for feed water)
Any
1.0 1.0 1.5
2.0
Cooling Systems I I
Chilled Water, Refrigerant,
40-55
0.5 0.5 0.75
1.0
and Brine
Below 40
1.0 1.0 1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Area Calculator:
Window
Name
Assembly Type
Comments/
Description
ins
��i�i�■�■■i��
Window Area Total 13050
02/19/03 07:39 03 1/1
Area Calculator:
Door
Name
Comments/
Description
2868 Exterior
French
` .::
Door Area Total- 55 56
02/19/03 07:39.03
1/1
Area Calculator:
■
► .
p
:■0�
Flat Ceili ..Comments/DescriptionFlat
Ceiling or Scissor Truss
02/19/03 07:39:04
Ceiling Area Total: 1198.00
1/1
Area Calculator:
02/19/03 07:39.04 Exterior Wall Area Total: 2306.00
IN
Area Calculator:
02/19/03 07:39:05 Floor Area Total 0.00
f