Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-03399 3521 MYTH LN BUILDING PERMIT
City of Collegge Station _ WORF QUEST PAGE 1 REQ/JOB: WF0474549 /.J.,d01 PROJECT ,-• , REQUEST DATE: 11'/20/03 PRINT DATE: 11/20/03 CREW: PRINT TIME: 8,:50:44 - SCHEDULE DATES LOCATION: 3521 MYTH`LN START: 11/20/03 77845 COMPLETION: 11/20/03 GEN. LOC: _"COLLEGE STATION LOC ID: 192496 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: HERITAGE TOWNHOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE WTR 3/4" ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- SWR 4" WTR 3/4" SWR 4" Category. code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE PREPARED 6/25/04, 7:36:24 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/25/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3521 MYTH LN SUBDIV: HERITAGE TOWNHOMES CON.17ACT_OR T C CUSTOM HOMES PHONE (979) 774-1110 OWNERk . . HAUSMAN INTERESTS TOWNHOMES PHONE PARCEL . . 320500-0002-0100 APPL NUMBER: 03-00003399 RESIDENTIAL, 1 UNIT ATTACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100`01 12/10/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/10/03 AP 12/10/2003 08:10 AM SSTANLEY B115.01 3/16/04 DP BLDG, FRAMING TIME: 17:00 3/16/04 CA 03/15/2004 04:14 PM MALFORD B115 02 3/17/04 DP BLDG, FRAMING TIME: 17:00 3/17/04 AP 03/17/2004 08:32 AM SSTANLEY please call before going 220-7835 3 03/18/2004 07:52 AM MALFORD x seal penetratins in firewall B125101 6/25/04 BI BLDG, FINAL TIME: 17:00 06/24/2004 04:35 PM MALFORD -------------------------------------- COMMENTS AND NOTES ------------ �� ---------------------- r' e andi Alford - Insulation request inspection result, 3521 Myth, #03-3399 _ Page 1 From: Brian Henry " To: Carrillo, Gina; Stanley, Susan Date: 3/18/2004 3:38:46 PM Subject: Insulation request inspection result, 3521 Myth, #03-3399 Print for File Inspected insulation, 3521 Myth, #03-3399, T C Custom Homes, 3-18-04 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi - BUILDING PERMIT CITY OF COLLEGE STATI01 1101 TEXAS AVE 'COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496. ---------------------------------------------------------------------------- Application Number . . . . . 03-00003399 Date 11/20/03 Property Address . . . . . . 3521 MYTH LN Property ID . . 320500-0002-0100 R # . . . . . . . . . . . . . R110701 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HERITAGE TOWNHOMES Property Use . . . . . . . . RESIDENTIAL PropertyjZoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 132900 Owner Contractor ` ------------------------ HAUSMAN INTERESTS TOWNHOMES ------------------------ T C CUSTOM HOMES LTD TODD CARNES 1328 SOUTH LOOP W STE 100 230 SOUTHWEST PARKWY E HOUSTON TX 770544008 COLLEGE STATION TX 77840 (979) 774-1110 ------ Structure Information TOWNHOUSE ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1464.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS ,2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 238.00 ---------------------------------------------------------------------------- Permit .,. . . . . BUILDING PERMIT Additional desc . . GC Permit Fee . . . . 559.00 Plan Check Fee .00 Issue Date . . . . 11/20/03 Valuation . . . . 132900 Expiration Date 5/19/0�4 Qty Unit Charge Per Extension BASE FEE 460.00 33.00 3.0000 THOU BLDG, VAL 100001-500000 - 99.00 ----'------------------------------------------------------------------------ Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S)' PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT --------------------- - =--------------- BUILDING DEPT EPRESEN TIVE: APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003399 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER-17, 2000 INTERNATIONAL RESIDENTIAL CODE Page 2 Date 11/20/03 ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S ) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM'STATIC WATER PRESSURE TO 80 PSI For residential applications.with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating, of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS}AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED10R NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO•PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE�GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION ' 1101 TEXAS AVE COLLEGE STATION, TX,77840 PHONE: ------------------------------------------------------ (979)764-3570 -FAX: (979)764-3496 7--------------------- Page 3 Application Number . . . . . 03-00003399 Date 11/20/03 --------------------------------------------- Other Fees . . . . . . . . . ------------------------------- WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged Paid Credited Due Permit'Fee Total ---------- 559.00 -------------------- 559.00 ---------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1309.00 1309.00 .00 .00 -------------------------------------- --- h ---------------------------- BUILDING DEPT EPRESENT VE: C--N APPLICANT: Fw Office use ONy APPLICATION FOR BUILDING PERMIT DATE: CITY OF COLLEGE STATION APPLIcAnoN # f 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE # (979) 764-3570 (979).764-3496 FAX WWW.CI,COL'LEGESTATION.TX.US' ADDRESS/LOCATION: LOT O BLOCK 2- SUBDIVISION r BUSINESS/OWNER NAME: ��� PHONE: CONTRACTOR/HOMEOWNER �LM� PHONE: lOCI;?j�j CONTRACTOR ADDRESS: Zvi) <:Am r %koa wiw e . rt)ile/i0-i7ia'1I)&. l -n ELECTRICIAN: �� _ PLUMBER: fJT HVAC: �o �A �J GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) g REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK:Wv�:Qwyl ya iJ STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PJECT REGISTRATION# EABPRJ VALUATION: $ 1321 TOTAL ARE4.6 1� HEATED AREA: (Cost of labor and Materials) ►I [_UBUC SEWER {�F� SEPTIC/TREATMENT SYSTEM ®-SEWER TAP: J SIZI ATER TAP: S OTHER TAP: SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: 2 INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: TEMP POLE' ROOF TYPE: GARAGE TYPE: SINGLE QF__1 DOUBLE �TRIPLE ATTACH�j I�'1�,. DETACHED a CARPORT SIGNATURE OF APPLICANT•—Y I /`/1%`-' —.(�,it ,U%'tA..,-� sla OOM2 El EJ ly Ili 4 Official Use Only 4a � ents: YES r NO Plans Examiner Zoning'Official I i Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) 30 Glazing SHGC o Glazing U-Factor r l05 R value of ductwork `Z- A/C SEER rating 12 REScheck Compliance Certificate 2000 IECC `REScheckSoftware Version 3.5 Release 1 Data filename: C:\Documents\New Folder\tc-unit-I.rck TITLE: Unit I CITY: Bryan (Brazos County) rY ( Bh') STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family 1 DATE: 02/19/03 DATE OF PLANS: 02-18-03 PROJECT INFORMATION: Heritage Town Homes COMPANY INFORMATION: T.C. Custom Homes College Station, Texas (979)693-7835 I NOTES: This REScheck report was generated by R.A.I.: John Rhodes P.O. Box 9389 College Station, Texas 77842 (979)412-5066 COMPLIANCE: Passes Maximum UA = 652 Your Home UA = 403 38.2% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 First F1oorCeiling 1: Flat Ceiling or Scissor Truss Second floor Ceiling 2: Flat Ceiling or Scissor Truss First floor Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 428 30.0 0.0 15 533 30.0 0.0 19 1152 13.0 0.0 84 77 0.650 50 38 0.350 13 18 0.650 12 SHGC: 0.40 Second floor Wall 2: Wood Frame, 16" o.c. 944 13.0 0.0 77 Floor 1: Slab -On -Grade: Unheated 128 0.0 133 Insulation depth: 0.0' Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release 1 (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection he list. Builder/Designer Date I I REScheck Inspection Checklist 2000 IECC REScheck Software Version 3.5 Release I DATE: 02/19/03 TITLE: Unit I Bldg. Dept. Use Ceilings: [ ] 1. First F1oorCeiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Second floor Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments': Above -Grade Walls: [ ] 1. First floor Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: [ ] 2. Second floor Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments Windows: [ ] 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes i Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.350 Comments: [ ] 2. Door 2: Glass, U-factor: 0.650 Comments: Floors: 1 [ ) 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Solar Heat Gain Coefficient: [, ] I The area-weight4average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. i Materials Identification: Materials and' equipment must be installed in accordance with the manufacturer's installation instructions Materials and' equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ) All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ) Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems:' [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: t [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2.{ Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) I Up to 1 „ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 x Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2 Runouts 1 and Less 1.25 to 2 2.5 to 4 Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: i Name WindowAssembly 8.1 Type Metal Do c��oc�■���i Description �� ' . - •Frame, .. oil■�■��® 02/19/03 08.07:24 Window Area Total: 76.50 1/1 i Area Calculator: Door Name Assembly Type Commen—ts/ 2868 Exterior French 2868 Exterior Door awl fog 0 Door Area Total: 55.56 02/19/03 08:07:25 1/1 l Area Calculator: N WE'Flat --Assembly Type Ceiling or Scissor Truss Comments/Description or Scissor Truss © ME ©■�■�� G SOMEONE ME ■INNION■�� O ■EENNI■ ■�■�ME ® INNINN■ ME ME m �■IENNNI■�� m �■NNENI■ m �■INEINE 00 �■ ■�� ® ® ■�■�ME m ■�■ENO 02/19/03 08 07:25 Ceiling Area Total: 961 00 1/1 Area Calculator: Assembly Type Gross Area Comments/Description Exterior Wall Area Total: 2096.00 02/19/03 08:07 26 Area Calculator: Assembly Type Gross Area Oil 131111 0111111 02/19/03 08 07 26 Floor Area Total: 0.00 1/1