HomeMy WebLinkAboutRES2003-03398 3519 MYTH LN BUILDING PERMITCity
of Collegge
,5f.'' •r_ion
WORK ^.QUESL._ ......
PAGE
1:
_
REQ/JOB:
WFd474545
/ '001 PROJECT:
TREQUEST
11/20/PRINT 03
DATEDATE:
CREW:
PRINT TIME:
8:49:04
'SCHEDULE
DATES
LOCATION:
351-9 MYTH
LN
START:
11/20/03
7�7845
COMPLETION:
11/20/03
GEN. LOC:
COLLEGE
STATION LOC ID: 192494
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
HERITAGE
TOWNHOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
GCARRILLO
AUTH: GCARRILLO WORK TYPE:
ROUTINE
WTR 3/4"
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
SWR 4"
WTR 3/4"
SWR 4"
Category
code
CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department:
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
OT-CUSTOMER SERVICE
PREPARED 6/25/04, 7:36:24 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/25/04
------------------------------------------------------------------------------------------------
ADDRESS 3519 MYTH LN SUBDIV: HERITAGE TOWNHOMES
CONTRACTOR': T C CUSTOM HOMES PHONE (979) 774-1110
OWAR HAUSMAN INTERESTS TOWNHOMES PHONE
PARCkL 320500-0002-0090
APPL NUMBER: 03-00003398 RESIDENTIAL, 1 UNIT ATTACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/10/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/10/03 AP 12/10/2003 08:10 AM SSTANLEY
B115 01 3/16/04 DP BLDG, FRAMING TIME: 17:00
3/16/04 CA 03/15/2004 04:14 PM MALFORD
B115 02 3/17/04 DP BLDG, FRAMING TIME: 17:00
3/17/04 AP 03/17/2004 08:31 AM SSTANLEY
please call before going 220-7835
03/18/2004 07:52 AM MALFORD
seal penetrations in firewall
B125 01 6/25/04 BI BLDG, FINAL TIME: 17:00
06/24/2004 04:34 PM MALFORD
-------------------------------------- COMMENTS AND NOTES -----------
Mandi'Alford - Insulation request inspection result, 3519 Myth, #03- 98. yR Page 1
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 3/18/2004 3:37:06 PM
Subject: Insulation request inspection result, 3519 Myth, #03-3398
Print for File
Inspected insulation, 3519 Myth, #03-3398, T C Custom Homes, 3-18-04
Inspection result: Inspected OK for Good Cents
CC: Alford, Mandi
BUILDING PERMIT
_ 1.�nT_0Tt°"t?Ct GE * 9Af±01
COLLEGE STATION, TX 77840
PHONE: (979)76473570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . 03-00003398 Date 11/20/03
Property Address . . . . . . 3519 MYTH LN
Property`ID 320500-0002-0090
R # - R110700
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . HERITAGE TOWNHOMES
Property,Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation 131900
Owner Contractor
HAUSMAN INTERESTS TOWNHOMES T C CUSTOM HOMES
LTD TODD CARNES
1328 SOUTH LOOP W STE 100 230 SOUTHWEST PARKWY E
HOUSTON TX 770544008 COLLEGE STATION TX 77840
(979) 774=1110
------ Structure Information TOWNHOUSE -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1398.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER'TYPE PUBLIC
SERIAL ZONES 238.00
-------------:--------------------------------------------------------------
Permit . . . . BUILDING PERMIT
Additional desc '. . GC
Permit Fee . . . . 556.00 Plan Check Fee .00
Issue Date . . . . 11/20/03 Valuation . . . . 131900''
Expiration Date 5/19/04
Qty Unit Charge Per Extension
BASE FEE 460.00
32.00 3.0000 THOU BLDG, VAL 100001-500000 96.00
------------- --------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
--------DNG DEPT -------`RESENTAT--------
BUIL-------.- CA�� ----------------------------
IR P.
I AAn n �nl 1r%1 /M ,
APPLICANT:
BUILDING PERMIT _
CITY OF COLLEGE STATIO:
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
i Page 2
Application Number . . . . . 03-00003398 Date' 11/20/03
-----7----------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES -PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED,JGARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORMiFOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential -applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is.required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR,TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION
1003.3.3 (2000 IBC) AS APPROPRIATE
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS,PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE'GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
----------------------------------- --- - -----------------------------
BUILDING DEPT R PRESENTA
APPLICANT: Am \,Awu��
BUILDING PERMIT
CITY OF COLLEGE STATIOI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00003398
Date
11/20/03
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
--------'---------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
556.00
556.00
.00
.00
Plan Check'Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00 f
Grand Total
1306.00
1306.00
.00
.00
--------------- - - - -
BUILDING DE
APPLICANT:
t,
Fa Offs Use 0*
' E3APPLICATION FOR BUILDING PERMIT DATE:
CITY OF COLLEGE STATION APPucAnoN #
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP PoLE #
(979) 764-3570 (979).7643496 FAX
WWW.CI,COL'LEGESTATION.TX.US'
�,Q �✓� ADDRESS/LOCATION:
SLOT _ BLOCK SUBDIVISION
BUSINESS/OWNER NAME:'�Q�d (a►cj PHONE:
�'O CONTRACTOwHOMEOWNER: � PHONE: � `V-` 9:2
I� CONTRACTOR ADDRESS:
e -fX CFO
ELECTRICIAN: PLUMBER: PI b
HVAC: (� GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) 91EW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape -Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: _ti1tW . �Q�n*wc/
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) 90/ PRECT REGISTRATION# EABPRJ
VALUATION: $ 3i ► q �� �TOTAL AREA: HEATED AREA:
(Cost of Labor and Materials)
BLIC SEWER
SEPTIC/TREATMENT SYSTEM
FOSEWER TAP:q-11
S �I
LAJ
WATER TAP:
¢E
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: 2—
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
OTHER TAP: FOUNDATION TYPE:
SIZE
TEMP POLE' ROOF TYPE:
GARAGE TYPE: SINGLE a DOUBLE ">� TRIPLE
ATTACHr DETACHED 0 CARPORT
�
SIGNATURE OF APPLICANT
I
F
Plans Examiner
GK-
SI4
Ofciai Use Only
ents:
YES r NO
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
F
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release 1
Data filename: CADocuments\New Folder\tc-unith.rck
TITLE: Unit H
CITY: Bryan (Brazos County)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE:02/19/03 C
DATE OF PLANS: 02=18-03
PROJECT INFORMATION:
Heritage Town Homes
COMPANY INFORMATION:
T.C. Custom Homes
College Station, Texas
(979)693-7835
NOTES:
This REScheck report was generated by R.A.I.:
John Rhodes
P.O. Box 9389
College Station, Texas 77842
(979) 412-5066
COMPLIANCE Passe
Maximum UA = 623
Your Home UA = 379
39.2% Better Than Code'(UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
First F1oorCeiling 1: Flat Ceiling or Scissor Truss
414
30.0
0.0
14
Second floor Ceiling 2: Flat Ceiling or Scissor Truss
508
30.0
0.0
18
First floor Wall 1: Wood Frame, 16" o.c.
1116
13.0
0.0
81
Window l: Metal Frame:Double Pane with Low-E
71
0.650
46
SHGC: 0.40
Door 1: Solid
38
0.350
13
Door 2: Glass I
18
0.650
12
SHGC: 0.40
Second floor Wall 2: Wood Frame, 16" o.c. 920 13.0 0.0 75
Floor 1: Slab-On-Grade:Unheated 115 0.0 120
Insulation depth: 0.0'
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RESche'ckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the
REScheckInspection Chexklii A
Builder/Designer Date 1�p " L—U
REScheck Inspection Checklist
2000 IECC
RES check Software Version 3.5 Release I
DATE: 02/19/03
TITLE: Unit H
i
Bldg.
Dept.
Use
Ceilings:
[ ) 1. First FloorCeiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Second floor Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
( ] 1. First floor Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
[ ] 2. Second,floor Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ) 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650
For windows without labeled U-factors, describe features:
# PanesFrame Type Thermal Break? ( ] Yes [ ] No
Comments:
Doors:
[ ] I. Door 1: Solid, U-factor: 0.350
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.650
Comments:
Floors:
[ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] I . Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
[ ] 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
i
( ] Materials aind equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and'service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are, required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
( ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a`circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
( ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature ( F) Up to 1„ Up to L25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2. Minimum Insulation Thickness forHVACPipes
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes '
Ping System Types
Range F
2" Runouts
1" and Less
1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
I
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
i
Area Calculator:
02/19/03 07-41:17
Window Area Total• 70.50
1/1
Area Calculator:
Add to
Door
Library
Name
Assembly Type
Quantity
Width
x
Height
9
-_
Unit
Area
Total
U-Factor
SHGC
Comments/
1
3068 Front Door
Solid
1
Area
Description
2
2868 Exterior
Glass
1
3'-0"
6'-8"
20.00
20.00
ft2 .
0 500
French
2'-8"
6'-8"
17 78
17.78
ft2
0.580
3
2868 Exterior
Door
Solid
1
2'-8"
6'-8"
1778
17.78
ft2
0.500
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
02/19/03 07.41:18
Door Area Total- 55 56
1/1
Area Calculator:
02/19/03 07:41.18
Ceiling Area Total: 922.00
1/1
Area Calculator:
02/19/03 07:41.19
Exterior Wall Area Total. 2036.00
1/1
Area Calculator:
02/19/03 07:41:19
Floor Area Total: 0.00
1/1