Loading...
HomeMy WebLinkAboutRES2003-03398 3519 MYTH LN BUILDING PERMITCity of Collegge ,5f.'' •r_ion WORK ^.QUESL._ ...... PAGE 1: _ REQ/JOB: WFd474545 / '001 PROJECT: TREQUEST 11/20/PRINT 03 DATEDATE: CREW: PRINT TIME: 8:49:04 'SCHEDULE DATES LOCATION: 351-9 MYTH LN START: 11/20/03 7�7845 COMPLETION: 11/20/03 GEN. LOC: COLLEGE STATION LOC ID: 192494 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: HERITAGE TOWNHOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE WTR 3/4" ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- SWR 4" WTR 3/4" SWR 4" Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE PREPARED 6/25/04, 7:36:24 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/25/04 ------------------------------------------------------------------------------------------------ ADDRESS 3519 MYTH LN SUBDIV: HERITAGE TOWNHOMES CONTRACTOR': T C CUSTOM HOMES PHONE (979) 774-1110 OWAR HAUSMAN INTERESTS TOWNHOMES PHONE PARCkL 320500-0002-0090 APPL NUMBER: 03-00003398 RESIDENTIAL, 1 UNIT ATTACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/10/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/10/03 AP 12/10/2003 08:10 AM SSTANLEY B115 01 3/16/04 DP BLDG, FRAMING TIME: 17:00 3/16/04 CA 03/15/2004 04:14 PM MALFORD B115 02 3/17/04 DP BLDG, FRAMING TIME: 17:00 3/17/04 AP 03/17/2004 08:31 AM SSTANLEY please call before going 220-7835 03/18/2004 07:52 AM MALFORD seal penetrations in firewall B125 01 6/25/04 BI BLDG, FINAL TIME: 17:00 06/24/2004 04:34 PM MALFORD -------------------------------------- COMMENTS AND NOTES ----------- Mandi'Alford - Insulation request inspection result, 3519 Myth, #03- 98. yR Page 1 From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 3/18/2004 3:37:06 PM Subject: Insulation request inspection result, 3519 Myth, #03-3398 Print for File Inspected insulation, 3519 Myth, #03-3398, T C Custom Homes, 3-18-04 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi BUILDING PERMIT _ 1.�nT_0Tt°"t?Ct GE * 9Af±01 COLLEGE STATION, TX 77840 PHONE: (979)76473570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . 03-00003398 Date 11/20/03 Property Address . . . . . . 3519 MYTH LN Property`ID 320500-0002-0090 R # - R110700 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HERITAGE TOWNHOMES Property,Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation 131900 Owner Contractor HAUSMAN INTERESTS TOWNHOMES T C CUSTOM HOMES LTD TODD CARNES 1328 SOUTH LOOP W STE 100 230 SOUTHWEST PARKWY E HOUSTON TX 770544008 COLLEGE STATION TX 77840 (979) 774=1110 ------ Structure Information TOWNHOUSE ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1398.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER'TYPE PUBLIC SERIAL ZONES 238.00 -------------:-------------------------------------------------------------- Permit . . . . BUILDING PERMIT Additional desc '. . GC Permit Fee . . . . 556.00 Plan Check Fee .00 Issue Date . . . . 11/20/03 Valuation . . . . 131900'' Expiration Date 5/19/04 Qty Unit Charge Per Extension BASE FEE 460.00 32.00 3.0000 THOU BLDG, VAL 100001-500000 96.00 ------------- -------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT --------DNG DEPT -------`RESENTAT-------- BUIL-------.- CA�� ---------------------------- IR P. I AAn n �nl 1r%1 /M , APPLICANT: BUILDING PERMIT _ CITY OF COLLEGE STATIO: 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 i Page 2 Application Number . . . . . 03-00003398 Date' 11/20/03 -----7---------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES -PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED,JGARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORMiFOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential -applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is.required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR,TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS,PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE'GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 ----------------------------------- --- - ----------------------------- BUILDING DEPT R PRESENTA APPLICANT: Am \,Awu�� BUILDING PERMIT CITY OF COLLEGE STATIOI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003398 Date 11/20/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary --------'--------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 556.00 556.00 .00 .00 Plan Check'Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 f Grand Total 1306.00 1306.00 .00 .00 --------------- - - - - BUILDING DE APPLICANT: t, Fa Offs Use 0* ' E3APPLICATION FOR BUILDING PERMIT DATE: CITY OF COLLEGE STATION APPucAnoN # 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP PoLE # (979) 764-3570 (979).7643496 FAX WWW.CI,COL'LEGESTATION.TX.US' �,Q �✓� ADDRESS/LOCATION: SLOT _ BLOCK SUBDIVISION BUSINESS/OWNER NAME:'�Q�d (a►cj PHONE: �'O CONTRACTOwHOMEOWNER: � PHONE: � `V-` 9:2 I� CONTRACTOR ADDRESS: e -fX CFO ELECTRICIAN: PLUMBER: PI b HVAC: (� GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) 91EW CONSTRUCTION SLAB ONLY DUPLEX (Landscape -Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: _ti1tW . �Q�n*wc/ STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) 90/ PRECT REGISTRATION# EABPRJ VALUATION: $ 3i ► q �� �TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) BLIC SEWER SEPTIC/TREATMENT SYSTEM FOSEWER TAP:q-11 S �I LAJ WATER TAP: ¢E NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: 2— INTERIOR WALL TYPE: EXTERIOR WALL TYPE: OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE' ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE ">� TRIPLE ATTACHr DETACHED 0 CARPORT � SIGNATURE OF APPLICANT I F Plans Examiner GK- SI4 Ofciai Use Only ents: YES r NO Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls F Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release 1 Data filename: CADocuments\New Folder\tc-unith.rck TITLE: Unit H CITY: Bryan (Brazos County) STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE:02/19/03 C DATE OF PLANS: 02=18-03 PROJECT INFORMATION: Heritage Town Homes COMPANY INFORMATION: T.C. Custom Homes College Station, Texas (979)693-7835 NOTES: This REScheck report was generated by R.A.I.: John Rhodes P.O. Box 9389 College Station, Texas 77842 (979) 412-5066 COMPLIANCE Passe Maximum UA = 623 Your Home UA = 379 39.2% Better Than Code'(UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA First F1oorCeiling 1: Flat Ceiling or Scissor Truss 414 30.0 0.0 14 Second floor Ceiling 2: Flat Ceiling or Scissor Truss 508 30.0 0.0 18 First floor Wall 1: Wood Frame, 16" o.c. 1116 13.0 0.0 81 Window l: Metal Frame:Double Pane with Low-E 71 0.650 46 SHGC: 0.40 Door 1: Solid 38 0.350 13 Door 2: Glass I 18 0.650 12 SHGC: 0.40 Second floor Wall 2: Wood Frame, 16" o.c. 920 13.0 0.0 75 Floor 1: Slab-On-Grade:Unheated 115 0.0 120 Insulation depth: 0.0' Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RESche'ckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection Chexklii A Builder/Designer Date 1�p " L—U REScheck Inspection Checklist 2000 IECC RES check Software Version 3.5 Release I DATE: 02/19/03 TITLE: Unit H i Bldg. Dept. Use Ceilings: [ ) 1. First FloorCeiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Second floor Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: ( ] 1. First floor Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: [ ] 2. Second,floor Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ) 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # PanesFrame Type Thermal Break? ( ] Yes [ ] No Comments: Doors: [ ] I. Door 1: Solid, U-factor: 0.350 Comments: [ ] 2. Door 2: Glass, U-factor: 0.650 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] I . Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: i ( ] Materials aind equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and'service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are, required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ( ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a`circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ( ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to L25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2. Minimum Insulation Thickness forHVACPipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes ' Ping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, I 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) i Area Calculator: 02/19/03 07-41:17 Window Area Total• 70.50 1/1 Area Calculator: Add to Door Library Name Assembly Type Quantity Width x Height 9 -_ Unit Area Total U-Factor SHGC Comments/ 1 3068 Front Door Solid 1 Area Description 2 2868 Exterior Glass 1 3'-0" 6'-8" 20.00 20.00 ft2 . 0 500 French 2'-8" 6'-8" 17 78 17.78 ft2 0.580 3 2868 Exterior Door Solid 1 2'-8" 6'-8" 1778 17.78 ft2 0.500 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 02/19/03 07.41:18 Door Area Total- 55 56 1/1 Area Calculator: 02/19/03 07:41.18 Ceiling Area Total: 922.00 1/1 Area Calculator: 02/19/03 07:41.19 Exterior Wall Area Total. 2036.00 1/1 Area Calculator: 02/19/03 07:41:19 Floor Area Total: 0.00 1/1