Loading...
HomeMy WebLinkAboutRES2003-03397 3517 MYTH LN BUILDING PERMITPREPARED 6/25/04, 7:36:24 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/25/04 - ----------------------------------------------------------------------------------------------- ADDRESS . : 3517 MYTH LN SUBDIV: HERITAGE TOWNHOMES CONTRACTOR T C CUSTOM HOMES PHONE (979) 774-1110 OWNEK HAUSMAN INTERESTS TOWNHOMES PHONE PARCEL 320500-0002-0080 APPL NUMBER: 03-00003397 RESIDENTIAL, 1 UNIT ATTACHED NEW ---= ------------------------------------------------------------------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/10/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/10/03 AP 12/10/2003 08:10 AM SSTANLEY B115 01 3/16/04 DP BLDG, FRAMING TIME: 17:00 3/16/04 CA 03/16/2004 07:55 AM MALFORD if not ready please do not red tag .... did not call this one 9 in but called in all others for Myth B115 02 3/17/04 DP BLDG, FRAMING TIME: 17:00 # 3/17/04 AP 03/17/2004 08:32 AM SSTANLEY ! please call before going 220-7835 03/18/2004 07:53 ,AM MALFORD seal penetrations in firewall B125 01 6�/��5,/�4� BLDG, FINAL TIME: 17:00 IKL/fJy►tiy 0C 06/24/2004 04:34 PM MALFORD / 4 �,-------------------------------------- COMMENTS AND NOTES----------------------------------- PAGE 1 City of CollegORKtf'tion REQ/JOB: WF04.74562 /r`001 PROJECT: CREW REQUEST DATE: ffl20/03 20PRINT 03 PRINT TIME: 9:06:09 SCHEDULE DATES LOCATION: 3517 MYTH LN 03 77845 COMPLETION: 11/20/03 GEN. LOC: COLLEGE STATION LOC ID: 192492 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: HERITAGE TOWNHOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE SWR 4" 1 WTR 3/4" :.. SWR 4" WTR 3/4" Category code,,. CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE f Mandi Alford''- fnsulationrequest inspection result, 3517 Myth, #03-339f�,; Page 1 ? From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 3/18/2004 3:35:31 PM Subject: Insulation request inspection result, 3517 Myth, #03-3397 Print for File Inspected insulation, 3517 Myth, #03-3397, T C Custom Homes, 3-18-04 Inspection result: Inspected Ok for Good Cents CC: Alford, Mandi builiJlNu PERMIT I'll 1101 TEXAS AVE COLLEGE STATION,!TX 77840 PHONE:+(979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application'Number . . . . . 03-00003397 Date 11/20/03 Property Address . . . . . . 3517 MYTH LN Property ID . . . . . . . . 320500-0002-0080 R # . . . . . . . . . . . . . R110699 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . HERITAGE TOWNHOMES Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 124500 Owner Contractor HAUSMAN INTERESTS TOWNHOMES T C CUSTOM HOMES LTD TODD CARNES 1328 SOUTH LOOP W STE 100 230 SOUTHWEST PARKWY E HOUSTON TX 770544008 COLLEGE STATION TX 77840 (979) 774-1110 ------ Structure Information TOWNHOUSE ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy!Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB 'NUMBER OF GARAGE BAYS 3.00 HEATED AREA 1313.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 2.00 SEWER TYPE PUBLIC SERIAL ZONES 238.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GC Permit Fee . . . . 535.00 Plan Check Fee .00 Issue Date . . . . 11/20/03 Valuation . . . . 124500 Expiration Date 5/19/04 Qty Unit Charge Per Extension BASE FEE 460.00 25.00 3.0000 THOU BLDG, VAL 100001-500000 75.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT -------------------- ---------------- - --------------------------- BUILDING DEP- REP E ENTATIVE: APPLICANT: 4 bUibDiNU PERMIT CITY OF COLLEGE STATIO] 1101 TEXAS AVE COLLEGE STATION, TX 77840 1 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003397 Page 2 Date 11/20/03 ' ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION,AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RE8IDENTIAL- CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES.SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLSIAND.BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND.DECAY REMOVE ALL VEGETATION,AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS,APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR`TO COVERING ANY -WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATEtGARAGES Other Fees . . . . . . . . . .SEWER TAP 4" CITY INSTALL 350.00 BUILDING DE APPLICANT:L i ----------------- - -M A----------------------------- REPRES ATIVE: ti BUILDING PERMIT CITY OF COLLEGE STATIOI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ------------- ------------ (979)764-3570 FAX: (979)764-3496 7-------------------------------------------------- Page 3 Application Number 03-00003397 Date 11/20/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged Paid Credited ---------------------------------------- Due Permit Fee Total 535.00 535.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.0b 750.00 .00 .00 Grand Total 1285.00 1285.00 .00 .00 S ---7---------------------------------C --------------------------- BUILDING DEP EPRES ATIVE: Uv APPLICANT: i _ �,y .,ice . 4, '` � •' - t , A OlflCe 1. Orly x-• ,APPLICATION FOR BUILDING PERM T DATE: 7- CITY OF COLLEGE STATION nPPLICAnoN 1101 ,TEXAS AVENUE_' - : , _ COLLEGE. STATION, •TX' 77840 ;. ' TEMP POL # w (679) 764-3570• (979) _764-3496 FAX : WWW.CI,COLLEGE-STATION.TX.US: -ADDRESS/LOCATION:- 351'`I'-, BLOCK LOT �_ rr � _ 'SUBDIVISION��..r}�t� BUSINESS/OWNER NAME: PHONE:_IQq 3 _ _1 %3� . CONTRACT OR/HOMEOWNER: T� � �v'�� ��� PHONE:�q�',� �s 3 5U- CONTRACTOR ADDRESS:_ T D 01 io-0 ELECTRICIA1N,,,,, PLUMBER: I HVAC: OKN.II`)I CJ j GOOD'CENTS (Residential only): . CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION . SLAB ONLY DUPLEX'(Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK:` STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS, ACCESSIBILITY STANDARD (TAS) PR9JECT REGISTRATION# EABPRJ VALUATION: �✓00 V TOTAL AREA: MIA HEATED AREA: (Cost of Labor and Materials) �UBLIC SEWER NUMBER OF BEDROOMS: 2— SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 2- SEWER TAP: -INTERIOR WALL TYPE: SIM/� 11 IVI'WATER TAP: _'1 EXTERIOR WALL TYPE: OTHER TAP: FOUNDATION TYPE: C�Q Set, - TEMP POLE, ROOF TYPE: GARAGE TYPE: SINGLE - a DOUBLE, TRIPLE a ATTACHDETACHED ' a CARPORT a SIGNATURE OF APPLICANT_— Otircial Use Only ents: , ES r NO Plans Examiner Zoning Official' r - ter. :; ..v:•y,-. -�,; - - .. - - - _ _ - tEnergy;Code Compliance Information - % Glazing of exterior walls Insulation R value of exterior walls. -Insulation R value of ceiling 1 f flat areas) 1 Insulation Rvalue-of ceiling 2� (vaulted areas/no attic) Glazing SHGC , ' b Glazing U-Factor l05 R value,of ductwork - JC SEER rating 12.. L Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC RES check Software Version 3.5 Release 1 Data filename: C:\Documents\New Folder\tc-unit-A.rck TITLE: Unit A CITY: Bryan (Brazos County) STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 02/ 19/03 DATE OF PLANS: 02-18-03 PROJECT INFORMATION: Heritage Town Homes COMPANY INFORMATION: T.C. Custom Homes College Station, Texas (979)693-7835 NOTES: This REScheck report was generated by R.A.I.: John Rhodes P.O. Box 9389 College Station, Texas 77842 (979)412-5066 , COMPLIANCE: Passes Maximum UA = 556 Your Home UA = 440 20.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA First FloorCeiling 1: Flat Ceiling or Scissor Truss 1309 30.0 0.0 46 First floor Wall 1: Wood Frame, 16" o.c. 1376 13.0 0.0 96 Window 1: Metal Frame:Double Pane with Low-E 144 0.650 94 SHGC: 0.40 Door l: Solid 38 0.350 13 Door 2: Glass 18 0.650 12 SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated 172 0.0 179 Insulation depth: 0.0' 1 Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the RESchecklnspection ghegklist. Builder/Designer V Date Q3 REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release 1 DATE: 02/19/03 TITLE: Unit A Bldg. Dept. Use Ceilings: [ ] 1. First F1oorCeiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: [ ] I. First floor; Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] I. Door 1: Solid, U-factor: 0.350 I Comments: [ ] 2. Door 2: Glass, U-factor: 0.650 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. { Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance'with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ) Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats arelrequired for each separate HVAC system. A manual or automatic means to partially restrict Ior shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over'20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Window Name Comments/ Description OEM Window Area Total 144 00 02/19/03 07:40 28 1/1 Area Calculator: Door Name ©�2868 Exterior French �■ , ® „ 2868 Exterior Door Eno i� i■i i�M�i mom■ ��■�■����� 02/19/03 07:40:28 Door Area Total: 55.56 1/1 Area Calculator: 02/19/03 07:40.29 Ceiling Area Total. 1309 00 1/1 Area Calculator: ■Assembly Type ©�B © Comments/Description Milli=■�■� 02/19/03 07:40 29 Exterior Wall Area Total. 1376.00 1/1 Area Calculator: Assembly Type Unheated Slab -On -Grade Floor Area Total: 0 00 02/19/03 07.40.30 1/1