HomeMy WebLinkAboutRES2003-03388 1407 ELKTON CT BUILDING PERMITCity of Collegge Station
WORF ;QUEST
REQ/JOB: WF0472673 /-001 PROJECT:
CREW:
r
PAGE 1
Y`PRQINTSDADATE: 11%11%03
PRINT TIME: 16:14:25
SCHEDULE DATES
LOCATION:
1407 ELKTON CT
03
77845
COMPLETION: 11/11/03
GEN. LOC:
COLLEGE STATION LOC ID:
198874
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL„
REQUESTOR:
ED FROEHLING ORIGIN:
CUSTOMER -WALK IN
USER ID:
MRODGERS AUTH: MRODGERS WORK
TYPE:
ROUTINE
3/4"WTR,
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
4"SWR
3/4"WTR,
4"SWR
Category
code CS -CUSTOMER SERVICES
CSCS
Task cone:
SET UP NEW UTILITY ACCT
SET
Facility
ID .
Assigned Department:
OT-CUSTOMER SERVICE
I
8
N
PREPARED 7/20/04, 7:34:45 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/20/04
------------------------------------------------------------------------------------------------
ADDRESS . : 1407 ELKTON CT SUBDIV: SHENANDOAH PH 9
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 569500-0933-0120
APPL NUMBER: 03-00003388 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT= BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/08/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00
�, .. 12/09/03 AP 12/06/2003 10:30 AM GCARRILLO
'`- Slab Ground Installed
Strings On Setbacks O.K.
B11+5 01 1/22/04 DP BLDG, FRAMING TIME: 17:00
2/12/04 DP O1/22/2004 11:55 AM MALFORD
window is ordered will install when delivered
need windbracing in back right room to right of window
need joist hangers in laundry.
perlin over laundry must be 4" oc.
B115 02 3/03/04 DS BLDG, FRAMING TIME: 17:00
3/03/04 AP 03/03/2004 11:43 AM MALFORD
B130 01 3/11/04 DP BLDG, INSULATION TIME: 17:00
3/11/04 AP 03/10/2004 03:52 PM GCARRILLO
B125 01 7/20 04 BI BLDG, FINAL TIME: 17:00
%tIZ2 � }�P 07/19/2004 03:25 PM MALFORD
k s
-------------------------------------- COMMENTS AND NOTES --------------------------------------
O �1.�
A.
BUILDING PERMIT
'II�r
r�-' KITWI,
� T .S," VE
COLLEGE
STATION, TX 77840
PHONE: (979)764-3570
----------------------------------------------------------------------------
FAX: (979)764-3496
Application Number . .
. . . 03-00003388, Date 11/11/03
,. Property,Address . . .
. . . 1407 ELKTON CT
Property ID . . . . . .
'. 569500-0933-0120
R # . . . . . . . .
. . . R*****
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . SHENANDOAH PH 9
Property Use . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . SINGLE FAMILY RESIDENTIAL
Application valuation .
. . . 133188
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
------ Structure Information SINGLE FAMILY -----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2018.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 245.00
----------------------------------------------------------
Permit . . . . . . BUILDING
7-----------------
PERMIT
Additional desc . . SS
Permit Fee . . . .
562.00' Plan Check Fee .00
Issue Date
11/11/03 Valuation . . . . 133188
Expiration Date
5/10/04
Qty Unit Charge Per Extension
BASE FEE 460.00
34.00 3.0000 THOU BLDG, VAL 100001-500000 102.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
-
-------------------------------------- - -a - ----------------------------
BUILDING DEPT REPRESENTATIVE: J�
A P P L I CANT :
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
03-00003388
Page 2
Date 11/11/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
ATTACHED,GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM`FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING.VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
ADD'SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS'AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4" CITY INSTALL
350.00
WATER TAP
3/4" CITY INSTL
400.00
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
562.00
562.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1312.00
1312.00
.00
.00
-------------------------- CIA - ---------------------------
BUILDING DEPT REPRESENTATIVE: t
APPLICANT: ��' -
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00003388 Date 11/11/03
----------- ------------------------ - -- -------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
A
I
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
DATI
APPL
For Off— Use any
ICATION # 03-33n
COLLEGE STATION, TX 77840
TEM
POLE # !
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: �O
SEC/PH _
LOT ' y BLOCK % SUBDIVISION oa
BUSINESS/OWNER NAME:
.
PHONE:
I
CONTRACTOR/HOMEOWNER: F�2ofHcwG Suit�PER IA�C
P HP
NE:
CONTRACTOR ADDRESS: 7 141414 o E 6
I
ELECTRICIAN: 13H3 PLUMBER:
rftE
!01-UM81AIdy
only):
HVAC: 11--'N0VhT"1 V6 661tVlGA GOOD CENTS (Residentia
CLASS OF WORK
ACCESSORY/STORAGE LOCATION
E-ROOF (Total/Partial)
ADDITION MOVING
SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION
SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION
SWIMMING POOL
Req)
DESCRIPTION OF WORK:
i
STRUCTUREiUSE: 47,v4cE r0,41nli-Y fz�5/DEN��E
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ _
VALUATION: $ �;�i ��
TOTAL AREA: A
HE
(Cost of Labor and Materials)
Ell'PUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
SEWER TAP.
INTERIOR WALL TYPE:
SIZE
WATER TAP: Y4 11
EXTERIOR WALL TYPE:
SIZE
OTHER TAP: FOUNDATION TYPE: CA(
SIZE
TEMP POLE ROOF TYPE: ca
GARAGE TYPE: SINGLE a DOUBLE �_ TRIPLE C
ATTACHED DETACHED a CARPORT C
SIGNATURE OF APPLICANT:
Official Use Only
CN �illlla�
Plans Examiner Zoning Official
I I
I
ROYAL:
TED AREA:
Snents:
YE' Nr NO
13
Energy Code Compliance Information
i
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\LT12BK33.rck
TITLE: LOT 12 BLOCK 331
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE:10/17/03 1
DATE OF PLANS: DECEMBER 13, 2002
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
f
COMPLIANCE: Passes
Maximum UA = 596
Your Home UA = 504
15.4% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.31
.I
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c,
Window 1: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Window 5: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.81
Window 6: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 6.00
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.l
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
.t
Permit Num
Checked
Gross
GI
Area or
Cavity
Cont.
or
Perimeter
R-Value
R-Value
U-
1843
30.0
0.0
447
13.0
0.0
32
0.1
38
0
4 0
38 0
344 13.0 0.0
6 0
UA i
I
65 j
27
I
20
24
3
15
28'
4
1
1
Bldg. faces 135 deg. from North; Comp. —ent.: Left Side
Projection factor: 0.43 ,
Window 7: Metal Frame:Double Pane with Low-E 2 0.6
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 1.00
Wall 3: Wood Frame, 16" o1c. 446 13.0 0.0
Window 3: Metal Frame:Double Pane with Low-E 40 0.6
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 1.18
Window 8: Metal Frame:Double Pane with Low-E 32 0.6
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 1.00
Door 2: Glass 18 0.5
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.81
Wall 4: Wood Frame, 16" ox. 371 13.0 0.0
Window 4: Metal Frame:Double Pane with Low-E 2 0.6
SHGC: 0.40
Bldg. faces 135 deg. froml North; Comp. orient.: Right Side
Projection factor: 1.00
Window 9: Metal Frame:Double Pane with Low-E 14 0.6
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Unheated 185 0.0
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 10 SEER
Boiler 1: Click here to select Assembly, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the
and other calculations submitted with the permit application. The proposed building has been design
requirements in REScheckN ersion 3.5 Release lb (formerly MECchecl and to comply with the mal
the RES checkInspection Checklist.
Builder/Designer=�Date Q
i
I
29
26
20
10
29
1
9
193
Ming plans, specifications,
to meet the 20001ECC
story requirements listed in'
L O -r 11
LoT 5
L oT 9-
u 5,
�oK —
i
LnT 13
�j
O� M L O T 1 2 I
33
b�� I SHEN/�N�DOAN
1%
2
parvK wAY
I
6Q, p�f 2. ,p y5,A9n/T