HomeMy WebLinkAboutRES2003-03388 1407 ELKTON CT BUILDING PERMITCity of Collegge Station WORF ;QUEST REQ/JOB: WF0472673 /-001 PROJECT: CREW: r PAGE 1 Y`PRQINTSDADATE: 11%11%03 PRINT TIME: 16:14:25 SCHEDULE DATES LOCATION: 1407 ELKTON CT 03 77845 COMPLETION: 11/11/03 GEN. LOC: COLLEGE STATION LOC ID: 198874 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL„ REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 4"SWR 3/4"WTR, 4"SWR Category code CS -CUSTOMER SERVICES CSCS Task cone: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE I 8 N PREPARED 7/20/04, 7:34:45 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/20/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1407 ELKTON CT SUBDIV: SHENANDOAH PH 9 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 569500-0933-0120 APPL NUMBER: 03-00003388 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT= BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/08/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 �, .. 12/09/03 AP 12/06/2003 10:30 AM GCARRILLO '`- Slab Ground Installed Strings On Setbacks O.K. B11+5 01 1/22/04 DP BLDG, FRAMING TIME: 17:00 2/12/04 DP O1/22/2004 11:55 AM MALFORD window is ordered will install when delivered need windbracing in back right room to right of window need joist hangers in laundry. perlin over laundry must be 4" oc. B115 02 3/03/04 DS BLDG, FRAMING TIME: 17:00 3/03/04 AP 03/03/2004 11:43 AM MALFORD B130 01 3/11/04 DP BLDG, INSULATION TIME: 17:00 3/11/04 AP 03/10/2004 03:52 PM GCARRILLO B125 01 7/20 04 BI BLDG, FINAL TIME: 17:00 %tIZ2 � }�P 07/19/2004 03:25 PM MALFORD k s -------------------------------------- COMMENTS AND NOTES -------------------------------------- O �1.� A. BUILDING PERMIT 'II�r r�-' KITWI, � T .S," VE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ---------------------------------------------------------------------------- FAX: (979)764-3496 Application Number . . . . . 03-00003388, Date 11/11/03 ,. Property,Address . . . . . . 1407 ELKTON CT Property ID . . . . . . '. 569500-0933-0120 R # . . . . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 9 Property Use . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 133188 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2018.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 245.00 ---------------------------------------------------------- Permit . . . . . . BUILDING 7----------------- PERMIT Additional desc . . SS Permit Fee . . . . 562.00' Plan Check Fee .00 Issue Date 11/11/03 Valuation . . . . 133188 Expiration Date 5/10/04 Qty Unit Charge Per Extension BASE FEE 460.00 34.00 3.0000 THOU BLDG, VAL 100001-500000 102.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) - -------------------------------------- - -a - ---------------------------- BUILDING DEPT REPRESENTATIVE: J� A P P L I CANT : BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 03-00003388 Page 2 Date 11/11/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE ATTACHED,GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM`FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING.VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI ADD'SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS'AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 562.00 562.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1312.00 1312.00 .00 .00 -------------------------- CIA - --------------------------- BUILDING DEPT REPRESENTATIVE: t APPLICANT: ��' - BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003388 Date 11/11/03 ----------- ------------------------ - -- ------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: A I APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE DATI APPL For Off— Use any ICATION # 03-33n COLLEGE STATION, TX 77840 TEM POLE # ! (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: �O SEC/PH _ LOT ' y BLOCK % SUBDIVISION oa BUSINESS/OWNER NAME: . PHONE: I CONTRACTOR/HOMEOWNER: F�2ofHcwG Suit�PER IA�C P HP NE: CONTRACTOR ADDRESS: 7 141414 o E 6 I ELECTRICIAN: 13H3 PLUMBER: rftE !01-UM81AIdy only): HVAC: 11--'N0VhT"1 V6 661tVlGA GOOD CENTS (Residentia CLASS OF WORK ACCESSORY/STORAGE LOCATION E-ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: i STRUCTUREiUSE: 47,v4cE r0,41nli-Y fz�5/DEN��E HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ _ VALUATION: $ �;�i �� TOTAL AREA: A HE (Cost of Labor and Materials) Ell'PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP. INTERIOR WALL TYPE: SIZE WATER TAP: Y4 11 EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: CA( SIZE TEMP POLE ROOF TYPE: ca GARAGE TYPE: SINGLE a DOUBLE �_ TRIPLE C ATTACHED DETACHED a CARPORT C SIGNATURE OF APPLICANT: Official Use Only CN �illlla� Plans Examiner Zoning Official I I I ROYAL: TED AREA: Snents: YE' Nr NO 13 Energy Code Compliance Information i % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\LT12BK33.rck TITLE: LOT 12 BLOCK 331 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE:10/17/03 1 DATE OF PLANS: DECEMBER 13, 2002 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC f COMPLIANCE: Passes Maximum UA = 596 Your Home UA = 504 15.4% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.31 .I Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c, Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.23 Window 5: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.81 Window 6: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 6.00 Door 1: Solid Wall 2: Wood Frame, 16" o.c.l Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 .t Permit Num Checked Gross GI Area or Cavity Cont. or Perimeter R-Value R-Value U- 1843 30.0 0.0 447 13.0 0.0 32 0.1 38 0 4 0 38 0 344 13.0 0.0 6 0 UA i I 65 j 27 I 20 24 3 15 28' 4 1 1 Bldg. faces 135 deg. from North; Comp. —ent.: Left Side Projection factor: 0.43 , Window 7: Metal Frame:Double Pane with Low-E 2 0.6 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 1.00 Wall 3: Wood Frame, 16" o1c. 446 13.0 0.0 Window 3: Metal Frame:Double Pane with Low-E 40 0.6 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 1.18 Window 8: Metal Frame:Double Pane with Low-E 32 0.6 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 1.00 Door 2: Glass 18 0.5 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" ox. 371 13.0 0.0 Window 4: Metal Frame:Double Pane with Low-E 2 0.6 SHGC: 0.40 Bldg. faces 135 deg. froml North; Comp. orient.: Right Side Projection factor: 1.00 Window 9: Metal Frame:Double Pane with Low-E 14 0.6 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 185 0.0 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER Boiler 1: Click here to select Assembly, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the and other calculations submitted with the permit application. The proposed building has been design requirements in REScheckN ersion 3.5 Release lb (formerly MECchecl and to comply with the mal the RES checkInspection Checklist. Builder/Designer=�Date Q i I 29 26 20 10 29 1 9 193 Ming plans, specifications, to meet the 20001ECC story requirements listed in' L O -r 11 LoT 5 L oT 9- u 5, �oK — i LnT 13 �j O� M L O T 1 2 I 33 b�� I SHEN/�N�DOAN 1% 2 parvK wAY I 6Q, p�f 2. ,p y5,A9n/T