Loading...
HomeMy WebLinkAboutRES2003-03379 1450 FINCASTLE LOOP BUILDING PERMITCity of Collegge St-ation WOR- BEQUEST PAGE 1 REQ/JOB: WF0472659 / 001 PROJECT: REQUEST DATE: 11/11/03 r PRINT DATE: 11/11/03 CREW: PRINT TIME: 16:10:15 SCHEDULE DATES LOCATION: 1450 FINCASTLE LOOP START: 11/11/03 77845 COMPLETION: 11/11/03 GEN. LOC: COLLEGE STATION LOC ID: 198844 REF, NBR : REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, 411SWR 3/4"WTR, 411SWR Category code CS -CUSTOMER SERVICES CSCS Task code: t. SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------ ------------------------------------------ PREPARED 12/28/04, 12:17:08 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/28/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1450 FINCASTLE LOOP SUBDIV: SHENANDOAH PH 9 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 569500-0932-0260 APPL NUMBER: 03-00003379 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/21/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 11/24/03 AP 11/21/2003 10:35 AM MALFORD slab ground back left side strings -on setbacks, ok" B115 01 1/02/04 DS BLDG, FRAMING TIME: 17:00 1/02/04 AP O1/02/2004 11:28 AM SSTANLEY B130 01 1/06/04 DS BLDG, INSULATION TIME: 17:00 1/06/04 AP O1/06/2004 11:29 AM MALFORD B125 01 12/28/04 BI BLDG, FINAL TIME: 17:00 T/S: 12/28/2004 08:59 AM LHOWE ------------------------- s -------------------------------- COMMENTS AND NOTES -------------------------------------- � � BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003379 Date 11/11/03 Property'Address. . . . . . . 1450 FINCASTLE LOOP PropertyiID 569500-0932-0260 R # . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 9 PropertytUse . . . . . . . . RESIDENTIAL PropertylZoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 122430 Owner Contractor ------------------------ R ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1855.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 245.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 529.00 Plan Check Fee .00 Issue Date . . . . 11/11/03 Valuation . . . . 122430 Expiration Date . . 5/10/04 Qty Unit Charge Per Extension BASE FEE 460.00 23.00 3.0000 THOU BLDG, VAL 100001-500000 69.00 --------------'-------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES -IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF`MECHANICAL EQUIPMENT ------=- -------- BUILDING DEPT REPRESENTATIVE: I APPLICANT: ��- ���- BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979)-764-3496 t Page 2 Application Number . . . . . 03700003379 Date 11/11/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHEDIGARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM'FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or imore . PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR,TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" C TY INSTALL 350.00 ------------------------ - ------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: r BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003379 Date 11/11/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 529.00 529.00 .00 .00 Plan Check Total .00* .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1279.00 1279.00 .00 .00 -------------------- ----cAAV -------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003408 Date 11/11/03 Property,Address . . . . . . 1450 FINCASTLE LOOP Property{ID 569500-0932-0260 R # . . . . . . . . . . . . . R***** Tenant nbr, name . . . . . . TEMP POLE Application description '. . . TEMP POLE Subdivision Name . . . . . . SHENANDOAH PH 9 Property,•Use . . . . . . . . RESIDENTIAL Property;Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING k 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------------- -------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc ... SS Permit Fee . . . . 20.00 Issue'Date . . . . 11/11/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 1 65.00 65.00 .00 .00 ------------------------ -------------------------- BUILDING DEPT REPRESENTATIVE: AP PL I CANT: t f, t - Fw Off— Use /y , r; 1 ` ` APPLICATION FOR BUILDING PERMIT DATE: CITY OF COLLEGE STATION APPLICATION # - 1101 TEXAS'AVENUE %�-- 03 COLLEGE STATION, TX•77840 TEMP POLE # t13 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ALIF ADDRESS/LO ATION: LOT �l.l BLOCK SUBDIVISION li( f 1 SEC/PH "1 BUSINESS/OWNER NAME: k PHONE: - CONTRACTOR/HOMEOWNER: fpf'2oEkLw6 tgotc.DER 1Ac)C, PHONE: 776'$466' CONTRACTOR ADDRESS: 319S 7 14144 L o.yESDh'F �/Fb ELECTRICIAN: 6#-8 .640-r&(c-.' PLUMBER:-r1Z1?4E HVAC: a'-G- 1161.)0V14T1 Vfs. 5L/LV(c.E - GOOD CENTS (Residential only):, CLASS OF WORK ' ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION 'MOVING SHELL ONLY DEMOLITION (Asbestos Survey) `NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans 'REMODEL/RENOVATION SWIMMING POOL Req) [,,, I DESCRIPTION OF WORK: t . k f STRUCTURE USE: TS/,t�G�E f/+'1/LY 2.g'S/DEiyc�E HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION ' $ lo�a �{3r7 TOTAL AREA: _-�340' HEATED AREA: 15 '(Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTICJTREATMENT,SYSTEM NUMBER OF BATHROOMS: a �SEWERTAP: "INTERIOR WALL TYPE: SIZE WATER TAP: �4 EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: 1 tJ SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE F_� DOUBLE TRIPLE a ATTACHED DETACHED F7 CARPORT ' ' F f SIGNATURE' OF APPLICANT: Official Use Only ments: YES r NO Plans Examiner Zoning Official I Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating " k, REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\LT26BK32.rck TITLE: LOT 26, BLOCK 32 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family I � DATE:10/17/03 i DATE OF PLANS: DECEMBER 13, 2002 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 644 Your Home UA = 576 10.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.35 t Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" O.C. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 l Bldg. faces 315 deg. from North; Comp. orient.: Front Projection factor: 0.23 Door l: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 1 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 0.43 Door 2: Glass SHGC: 0.78 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 0.81 Wall 3: Wood Frame, 16" o.c. Window 4: Metal Frame:Double Pane with Low-E I Permit Number Checked By/Date u Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1855 30.0 0.0 65 396 15.0 0.0 23 54 0.640 35 38 0.800 30 465 15.0 0.0 34 6 0.640 4 18 0.580 10 409 15.0 0.0 20 151 0.640 97 .t SHGC:0.40 Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o�:c. 470 15.0 0.0 35 Window 4: Metal Frame:Double Pane with Low-E 14 0.640 9 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 205 0.0 214 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in the REScheckInspection Checklist. •�Q� _ Builder/Designer Date 0 Y 4 1 0 H/0512003 ,AED S,51 FAX 97a 693 /554 McClure Engineering Inc, 144 Freehling, Edwar 2005,005. I r ' RMCOStle LOOP 50' jta'W. N 27' Pavement Buo1VCurbZ N .57$11- E.— MOO �,,, In t (y N r i Residence Scale. 1' 20' _ ln1 2sl a a La! 25 Now or Formwrly Now er Fol eaMy Ed Frol�Minq 9uil W Inc I � � � Ed Finahling BuMer, 1mr. Vel. 4311, Pg 14 _ Ih ot, 1D]w�](�. Qlb VOL 45'14, Py. 14 L�i/ir Qliflfwo lg�i � ; 4 7.r 4e.s• I �.5 ) Note, eundbg Smock Uno per 7 i College stone+ UnNiod - _[ iop .. .. oever�nt ordh�ono. ;sr51> City oF— . L .. , . 10, P.U.F. S 452s y i II r moo' Fuhms ftwo of Sw4ndoon 4 Ed FreMling builder, Ine. Val. 4514, Pg. 14 01-26b32.dwg ANCCZ,11W"G/NE"1MG, INC • fM jWOA* m#107 Me, S.Vi10 ;0,3 • COIA S&AW7 70"S 7794.1f t1s q) 0-0."h w