HomeMy WebLinkAboutRES2003-03374 212 HARTFORD DR BUILDING PERMITCity
of College St on -
WORK )UEST »
PAGE
1
REQ/JOB:
WF0474320 / 001 PROJECT: -
DATE:
REQINTSDATE
PR:
11f1/03
9
CREW:
PRINT TIME:
13:46:47
SCHEDULE
DATES
LOCATION:
212 HARTFORD DR
START:
11/19/03
77845
COMPLETION:
11/19/03
GEN. LOC:
COLLEGE STATION LOC ID:
197566
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
B A'CATHEY LTD ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MRODGERS AUTH: MRODGERS WORK
TYPE:
ROUTINE
3/4"WTR,
--------------------------------------------------------------------
411SWR
3/4"WTR,
411SWR
Category
code CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department: OT-CUSTOMER SERVICE
PREPARED 5/27/04, 12:03:12 INSPECTION TICKET PAGE 10
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/27/04
------------------------------------------------------------------------------------------------
•ADDRESS . : 212 HARTFORD DR SUBDIV: EDELWEISS GARTENS PH 2
CONTRACTOR B A CATHEY LTD PHONE (979) 255-7064
OWNER EDELWEISS GARTEN VENTURE PHONE
IARCEL 244030-0204-0080
APPL NUMBER: 03-00003374 RESIDENTIAL, 1 UNIT ATTACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 1/14/04 DS BLDG, FOUNDATION -SLAB TIME: 17:00
1/14/04 AP 01/14/2004 08:51 AM GCARRILLO
late afternoon
' Strings On Setbacks O.K.
` Slab Ground Installed
I13115 01 3/09/04 DS BLDG, FRAMING TIME: 17:00
3/09/04 AP 03/09/2004 02:32 PM MALFORD
B125 01 S/,27 04 B p BLDG, FINAL TIME: 17:00
�1 1 05/27/2004 09:40 AM SSTANLEY
-------------------------------------- COMMENTS AND NOTES ------------------------------
Mandi Alford - Insulation request inspection result, 212 Hartford, #03-3374 Page 1
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 3/16/2004 9:34:13 AM
Subject: Insulation request inspection result, 212 Hartford, #03-3374
Print for File
Inspected insulation, 212 Hartford, #03-3374, B A Cathy, 3-16-04
Inspection result: Inspected OK for Good Cents
CC: Alford, Mandi
BUILDING PERMIT ,
C-I'F):__OF._COLLFQ1F STATION ,
1101 TEXAS AVE
COLLEGE STATION; TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-
---------------------------------------------------------------------------
Application Number . . . . . 03-00003374 Date 11/19/03
Property Address . . . . . . 212 HARTFORD DR
Property�ID 244030-0204-0080
R # . . . . . . R114630
Application description . . . RESIDENTIAL, 2 UNITS, NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 2
Property Use . . . . . . . . RESIDENTIAL
Property -Zoning . . . . . . . TOWNHOUSE
Application valuation . . . . 90750
Owner Contractor
------------------------ ------------------------
EDELWEISS GARTEN VENTURE B A CATHEY LTD
311 CECILIA LOOP BLAKE CATHEY
COLLEGE STATION TX 778456310 P 0 BOX 9517
COLLEGE STATION TX-77842
(979) 255-7064
------ Structure Information TOWNHOUSE -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy,Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
HEATED AREA 1375.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . SS
Permit Fee . . . . 424.00 Plan Check Fee .00
Issue Date . . . . 11/19/03 Valuation . . . . 90750
Expiration Date . . 5/18/04
Qty Unit Charge Per Extension
BASE FEE 260:00
41.00 4.0000 THOU BLDG, VAL 50001-100000 164.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS) '
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER,
BUILDING DEPT REPR NTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-35.70 FAX: (979) 764-3496
Application Number . . . . 03-00003374
Special Notes and Comments
Page 2
Date 11/19/03
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL°CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION'DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE I
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED'GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORMFOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications' with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS -AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE'FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL,BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
do not put electrical service on firewall side of the
garage
-------------------------------------------------- ---- - ---------------
BUILDING DEPT REPRESEJTATIVE: Qom/
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570- FAX: (979)764-3496
----------------------------------------------------------------------------
a Page 3
Application Number . . . . . 03-00003374 Date 11/19/03
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY -INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged
Permit Fee Total 424.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1174.00
Paid
424.00
.00
750.00
1174.00
Credited
.00
.00
.00
.00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BUILDING DEPT REPRESENT VE:
APPLICANT:
Due
00
00
.00.
.00
APPLICATION FOR BUILDING PERMIT E.
CITY OF COLLEGE STATION APPLICATION K
1101 TEXAS AVENUE ,
COLLEGE STATION, TX 77840 TEMP POLE N
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US ,1
ADDRESS/LOCATION: Z 1 7-
LOT 7 I BLOCK T SUBDIVISION �V�L �%Gl S
BUSINESS/OWNER NAME: T) L Olq4�4 c.: V LTIJ . PHONE: 2-5 S " ?Q 6 Ll
TOR/HOMEOWNER: PHONE: 2-- SS --`tQ 4
ONTRAC y
l CONTRACTOR' ADDRESS: '-R O Q5 e� L. LF6; I� 5Tp T-X'
v ELECTRICIAN: ;M LZ j_ej C- PLUMBER: CA � PI tAl—va/0'
\� HVAC: GOOD *CENTS (Residential only):
L&W-5
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING' SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE IUSE: 77o wN jowl K
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
TOTAL AREA: �� Z�- HEATED AREA:
VALUATION: $ �b�K I3? S
(Cost of Labor and Materials)
PUBLIC SEWER 96,156 NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM, NUMBER OF BATHROOMS: Z-
INTERIOR WALL TYPE: C7 YnsCd/y�
SEWER TAP:
SIZE
WATER TAP:
3
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE:
SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:'
a DOUBLE �✓
L�p_J DETACHED a
TRIPLE a
CARPORT
N C-t G 7_46�
Official Use Only ents•
_ C`A ' Il� 1863
Plans Examiner
Zoning Official
YE r NO
Energy Code Compliance Information S \ ti
% Glazing of exterior walls
Insulation R value of exterior walls �' 3
Insulation R value of ceiling 1 (flat areas) R- 30
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC `
Glazing U-Factor • L S
R value of ductwork
AJC SEER - rating �-