HomeMy WebLinkAboutRES2003-03363 204 HARTFORD DR BUILDING PERMITPREPARED 5/27/04, 12:03:12 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/27/04
------------------------------------------------------------------------------------------------
ADDRESS . : 204 HARTFORD DR SUBDIV: EDELWEISS GARTENS PH 2
CONTRACTOR B A CATHEY LTD PHONE (979) 255-7064
OWNER EDELWEISS GARTEN VENTURE PHONE
PARCEL 244030-0204-0120
APPL NUMBER: 03-00003363 RESIDENTIAL, 1 UNIT ATTACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 1/14/04 DS BLDG, FOUNDATION -SLAB TIME: 17:00
1/14/04 AP 01/14/2004 08:50 AM GCARRILLO
late afternoon
Strings On Setbacks O.K.
Slab Ground Installed
B1101 3/09/04 DS BLDG, FRAMING TIME: 17:00
3/09/04 AP 03/09/2004 02:29 PM MALFORD
B125101 5/27/04 BI BLDG, FINAL TIME: 17:00
05/27/2004 09:39 AM SSTANLEY
-------------------------------------- COMMENTS AND NOTES --------------------------------------
1
1 '
Mandi Alford - Insulation request inspection result, 204 Hartford, #03-3363 :` __ _. _._ ___, __ Page 1 ,1
From:
To:
Date:
Subject:
Print for File
Brian Henry
Carrillo, Gina; Stanley, Susan
3/16/2004 9:27:30 AM
Insulation request inspection result, 204 Hartford, #03-3363
Inspected insulation, 204 Hartford, #03-3363, B A Cathy, 3-16-04
Inspection result: Inspected OK for Good Cents
CC: Alford, Mandi
' BUILDINGPERNIT — ._,^_.
CITY _6F C , C SETA 4
TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------=`------------------------------------------
Application Number
Property Address . . .
PropertyiID
R# . . . . . . . . . .
Application description
Subdivision Name . . .
Property Use . . . . .
Property,Zoning . . . .
Application valuation .
Owner
EDELWEISS GARTEN VENTURE
311 CECILIA LOOP
. . . 03-00003363 Date 11/19/03
. . . 204 HARTFORD DR
. . 244030-0204-0120
. . . R114634
. . . RESIDENTIAL, 1 UNIT ATTACHED NEW
. . . EDELWEISS GARTENS PH 2
. . . RESIDENTIAL
. . . TOWNHOUSE
. . . 90750
COLLEGE STATION TX 7784563,10
i
Contractor
B A CATHEY LTD
BLAKE CATHEY
P 0 BOX 9517
COLLEGE STATION TX 77842
(979) 255-7064
------ Structure Information TOWNHOUSE -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1375.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
------------- =--------------------------------------------------------------
Permit .�. . . . . BUILDING PERMIT
Additional desc . . SS
Permit Fee . . . . 424.00 Plan Check Fee .00
Issue Date . . . . 11/19/03 Valuation . . . . 90750
Expiration Date 5/18/04
Qty Unit Charge Per Extension
BASE FEE 260.00
41.00 4.0000 THOU BLDG, VAL 50001-100000 164.00
-------------- 7-------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-------------------------------------------------- --- -------------
BUILDING DEPT R RESENTATIVE:
APPLICANT:
BUILDINGPERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003363
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
Page 2
Date 11/19/03
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER '99 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLSIAND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATEDI-OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
do not put electrical service on firewall side of the
------------------------------------------------ --- -- -----------------
BUILDING DEPT REPReSENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
--1101 TEXAS—AVE -
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00003363 Date 11/19/03
----------------------------------------------------------------------------
Special_Notes and Comments _
garage
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Other -Fee Total -
Grand Total
Charged Paid
424.00 424.00
.00 .00
-750.00 - 750.00
1174.00 1174.00
Credited Due
.00
.00
.00
.00
.00
.00-
.00
.00
-------------------------- -----------------------
BUILDING DEPT REPRE NTATIVE:
APPLICANT:
City of College Station
WORT 3QUEST
REQ/JOB: WF0474315--/-001
CREW:
PAGE 1
—PROJECT: REQUEST DATE: 11/19/03
PRINT DATE: 11/19/03
PRINT TIME: 13_:44:54
LOCATION: 204 HARTFORD DR SCHEDULE
STTART:DATES 11/19/03
77845 COMPLETION: 11/19/03
GEN. LOC: COLLEGE STATION LOC ID: 197574
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: B A CATHY LTD ORIGIN: CUSTOMER -WALK IN
USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE
3/4'WTR, 4"SWR
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4"WTR, 4"SWR
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
APF ATION FOR BUILDING PERMIT DATE
CITY yr COLLEGE STATION APPLICATION K 3
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE a
(979) 764-3S70 (979) 764-3496 FAX
WWW.CI.COLLEGESTATION.TX.US 11
ADDRESS/LOCATION:
LOT Z BLOCK SUBDIVISION'
BUSINESS/OWNER NAME: TS LAY g 0_44 I i F y LT/J . . PHONE: 2_S15 - ?D !Q �
/A�
ONTRACTOR/HOMEOWNER:bLlqr,(r� e_wf-gy PHONE: Z. SS yONTRACTOR ADDRESS: O 5 d L LF t, STD �''�LECTRICIAN: I�MktCcJS C�IL`LfiGi C. PLUMBER: C P/t,tAi+�htn,��VAC: ��42�C�'YLS GOOD CENTS (Residential only): CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE: —ro wN NoM F
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY TANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 8 TOTAL AREA: �� ZZ, HEATED AREA:
(Cost of La and Materials)
PUBLIC SEWER g6(�50 NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SIZE
/
WATER TAP: _ 3 Y
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE a
ATTACHED
SIGNATURE OF APPLICANT:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
c-, Y/>su.k
/3?I GK
FOUNDATION TYPE: 1 elONL'�G
ROOF TYPE: 051 / 5'T7N�7Lb S
DOUBLE F71 TRIPLE a
DETACHED F__j CARPORT
Official Use Only ents:
163 YES or NO
Plans Examiner Zoning Official.' -
19
1.,
Energy Code Compliance Information,,, '
% Glazing of exterior walls
Insulation R value of exterior walls �-13
Insulation R value of ceiling I (flat areas) 2' 30
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
'
Glazing U-Factor-
' LS
R value of ductwork
A/C SEER rating
t
t