Loading...
HomeMy WebLinkAboutRES2003-03362 202 HARTFORD DR BUILDING PERMITPREPARED 5/28/04, 12:00:46 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/28/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 202 HARTFORD DR SUBDIV: EDELWEISS GARTENS PH 2 CONTRACTOR B A CATHEY LTD PHONE (979) 255-7064 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0204-0130 APPL NUMBER: 03-00003362 RESIDENTIAL, 1 UNIT ATTACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 O1 1/14/04 DS BLDG, FOUNDATION -SLAB TIME: 17:00 1/14/04 AP O1/14/2004 08:49 AM GCARRILLO late afternoon Strings On Setbacks O.K. ! Slab Ground Installed B12� 01 3/08/04 BI BLDG, FINAL TIME: 17:00 3/09/04 CA 03/08/2004 09:55 AM MALFORD B115 01 3/09/04 DS BLDG, FRAMING TIME: 17:00 3/09/04 AP 03/09/2004 02:27 PM MALFORD •B125i 02 5/27/04 DP BLDG, FINAL TIME: 17:00 ' 5/27/04 DP 05/27/2004 09:39 AM SSTANLEY need weep holes in front B125 03 5/28/04 BI BLDG, FINAL TIME: 17:00 -'-0L 05/28/2004 10:25 AM GCARRILLO -----------------------------=-------- COMMENTS AND NOTES-------------------------------------- Mandi Alford - Insulation request inspection result, 202 Hartford, #03-3362 Page 1 From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 3/16/2004 9:25:46 AM Subject: Insulation request inspection result, 202 Hartford, #03-3362 Print for File Inspected insulation, 202 Hartford, #03-3362, B A Cathy, 3-16-04 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi Mandi Alford - Insulation request inspection result, 202 Hartford, #03-3362 Page 1 From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 3/16/2004 9:25:46 AM Subject: Insulation request inspection result, 202 Hartford, #03-3362 Print for File Inspected insulation, 202 Hartford, #03-3362, B A Cathy, 3-16-04 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS-AVE f COLLEGE STATION, TX 77840" PHONE: (979)764-3570 FAX: (979)764-3496 --------------------------------------------------- =----------------- '------ i. Application Number . . . . . 03-0b003362 Date 11/19/03 Property Address . . . . . . 202 HARTFORD DR Property ID 244030-0204-0130 R # . . . . . . R114635 Application description . . . RESIDENTIAL, 1 UNIT ATTACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . TOWNHOUSE Application valuation . . . . 90750 Owner Contractor EDELWEISS GARTEN VENTURE B A CATHEY LTD 311 CECILIA LOOP BLAKE CATHEY COLLEGE STATION TX 778456310 P 0 BOX 9517 COLLEGE STATION TX 77842 (979) 255-7064 ------ Structure Information TOWNHOUSE ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1822.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit G . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 424.00 Plan Check Fee .00 Issue Date . . . . 11/19/03 Valuation . . . . 90750 Expiration Date . . 5/18/04 Qty Unit Charge Per Extension BASE FEE 260.00 41.00 4.0000 THOU BLDG, VAL 50001-100000 164.00 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC —FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------------------------------------------------- —--------'---------- BUILDING DEPT R17z��: APPLICANT: s BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003362 Date 11/19/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED'GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORMFOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUMISTATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct . insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS,AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND'HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE{GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CI Y I STALL 350.00 ------------------------------ - .................... BUILDING DEPT REPSENTATIVE: / A. APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS�AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 --------------------------- ------------------------------------------------- Page 3 Application Number . . . . 03-00003362 Date 11/19/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee %summary Charged ----------------- ---------- Permit Fee -Total 424.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1174.00 Paid Credited Due ------------------------------ 424.00 .00 .00 .00 .00 .00 750.00 .00 .00 1174.00 .00 .00 --------------------------------------------- BUILDING DEPT REPRES TATIVE: I--- W�� ----- 11 ----------- APPLICANT: City of C611emq Station WORF EQUEST PAGE 1 REQ/JOB: WF0474314 / 001 PROJECT: REQUEST DATE: 11/19/03 PRINT DATE: 11/19/03 CREW: PRINT TIME: 13:44:34 SCHEDULE DATES LOCATION: 202 HARTFORD DR 03 77845 COMPLETION: 11%19%03 GEN. LOC: COLLEGE STATION LOC ID: 197576 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: B A CATHY LTD ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE �. 3/4"WTR, 411SWR� ------------------------------------------------------------------------------- 3/4"WTR, 4"SWR Category code CS -CUSTOMER -SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ----------------==------------------------------------------------------------- ------------------------------------------------------------------------------- I APPL ,TION FOR BUILDING PERMIT \TE. CITY Or %,OLLEGE STATION I APPLICATION K 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE a (979) 764-3570 (979) 764-3496 FAX I WWW.CI.COLLEGESTATION.TX.US tt\\ ADDRESS/LOCATION: 707— LOT i 3 , BLOCK SUBDIVISION �D�GGIGI S �4/LT�'/V S BUSINESSIOWNER NAME: T.) L �' �-�' 4 r y LT-b. PHONE: 2-5 — �0 t CONTRACTOR/HOMEOWNER: DL14K15 eW�4w!,l PHONE: Z SS --X0 L.q, ' _ L. Lre 57-4 . /NTRACTOR ADDRESS: O 5 U ELECTRICIAN: VhAws ML--r i-VCj C_ O HVAC: PLUMBER: GOOD CENTS (Residential only): �L ` CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) SHELL ONLY \ ADDITION I MOVING DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: M STRUCTURE USE: -7-0 wNNy•rt HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 8 TOTAL AREA: �� Z-Z— HEATED AREA: I37 S '(Cost of G and Materials) Ej PUBLIC SEWER 16 (I_60 NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �// SEWER TAP: INTERIOR WALL TYPE: C7 ynsUwL SIZE Q' WATER TAP: EXTERIOR WALL TYPE: SIZE O co TAD' FOUNDATION TYPE: T� L_jTH . SIZE /1 5(T�/✓��Lt� S TEMP POLE ROOF TYPE: —T GARAGE TYPE: SINGLE a DOUBLE F;71 TRIPLE a ATTACHED DETACHED a CARPORT SIGNATURE OF APPLICANT: Official Use Only ents: 18 p� YES r NO l ,Plans Examiner Zoning Official 4 i Energy Code Compliance Information'' % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) ' L ~ Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating M G•Y