Loading...
HomeMy WebLinkAboutRES2003-03307 303 SAPPHIRE DR BUILDING PERMIT/ City !" of College S1,t;ion �!Y WORK QUEST PAGE 1 ,REQ/JOB: WF0472185 / OU1 PROJECT: E: 1/10/ PRINT DATE: DATE 11 03 CREW: PRINT TIME: 11:51:17 SCHEDULE DATES LOCATION: 303 SAPPHIRE DR 03 77845 COMPLETION: 11/10/03 GEN. LOC: COLLEGE STATION LOC ID: 198626 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: WOOTAN HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK•TYPE: ROUTINE 4" SEWER --------------------------------------------------------=---------------------- ------------------------------------------------------------------------------- TAP AND 3/4" WATER TAP 4" SEWER TAP AND 3/4" WATER TAP Category code . CS -CUSTOMER SERVICES CSCS Task code: �: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------- 0 u PREPARED 5/26/04, 8:04:38 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/26/04 __; ---------------------------------------------------------------------------------------------- ADDRESS . : 303 SAPPHIRE DR SUBDIV: STONE FOREST PH 3 CONTRACTOR WOOTAN HOMES PHONE (979) 696-8975 OWNER JOHNSON INVESTMENTS INC PHONE PARCEL 585200-0304-0110 APPL NUMBER: 03-00003307 RESIDENTIAL, 1 UNIT DETACHED NEW -----------------------------------------------------------------------------------_------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/15/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/15/03 AP 12/15/2003 10:47 AM MALFORD B115 01 1/21/04 TB BLDG, FRAMING TIME: 17:00 1/21/04 AP O1/21/2004 10:13 AM SSTANLEY B130 01 4/05/04 LS BLDG, INSULATION TIME: 17:00 4/05/04 AP 04/05/2004 02:01 PM SSTANLEY see letter in file B125 01 /26/04 Bj,, BLDG, FINAL TIME: 17:00 05/.R 25/2004-02"28 PM MALFORD DOOIS-UNLOCKED -------------------------- ---- COMMENTS AND NOTES -------------------------------------- I I FROM :EDDY BOYD 1 FAX NO. :9797769743 02 2004 09:45AM P2 INSULATION SPEC1ALnES 2201 Colony Circle Bryan, `Cexas 77808 �! 979-776-9743 April 2, 2004 i City of College Station Inspection Department Attention: Lance Sims �- ave been Two houses built by 'Wootan Homes located at 302.�n and �3'Sahue insulated in the exterior walls with R-13 Batt Insulation and R-30 Blown Insulation in the attics over the heated areas. Also completed was the infiltration sealant as per city codes. The insulation application was done in accordance with the nmufacturers me recomndations and Collette Station city codes. Each house has a certificate of insulation completion form in the attic access. Sincerely, Eddy Boyd Owner City of College Station'' WORK REQUEST REQ/JOB: WF0473225 / 001 CREW: PAGE 1 PROJECT: REQUEST DATE: 21/14/03 PRINT DATE: 1-1/14/03• PRINT TIME: 7:32:18- LOCATION: 303 SAPPHIRE DR SCHEDULE STTART:DA11/14/03 1 77845 COMPLETION: 11/14/03 GEN. LOC: COLLEGE STATION LOC ID: 198626 I REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: WOOTAN HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED ----------------=--------------------------=----------------------------------- ------------------------------------------------------------------------------- TEMP POLE PASSED Category code'. CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . j . Assigned Department: OT-CUSTOMER SERVICE ----------------=-----------------------------------=-------------------------- ------------------------------------------------------------------------------- I i BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS .VE COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003307 Date" 11/10/03 Property;Address . . . . . . 303 SAPPHIRE DR Property ID . . . . . . . 585200-0304-0110 R # . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . STONE FOREST PH 3 Property�Use . . . . . . . . RESIDENTIAL PropertylZoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 151404 Owner Contractor ------------------------ I JOHNSON INVESTMENTS INC ------------------------ WOOTAN HOMES PO BOX 8010 CHAD WOOTAN COLEMAN TX 768340800 611 CASTLEBROOK COLLEGE STATION TX 77845 (979) 696-8975 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . "COMBUSTIBLE (UNPROTECTED) Occupancy #Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS `2.00 HEATED AREA 2294.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 t NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 =------- -------------------------------------------------------------------- Permit .E. . . . . BUILDING PERMIT Additional desc MA Permit Fee 616.00 Plan Check Fee .00 Issue Date . . . . 11/10/03 Valuation '. 151404 Expiration Date 5/09/04 i Qty ,Unit Charge Per Extension BASE FEE 460.00 52.00 3.0000 THOU BLDG, VAL 100001-500000 156.00 -------------- -------------------------------------------------------------- Special Notes and Comments` ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) I PROVIDE ATTIC ACCESS WITHIN 20"FEET OF MECHANICAL EQUIPMENT --------------=------------------------- -- - -- ------------------------- BUILDING DEPT REPRESENT I APPL I CANT : -- i Q BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003307 Date 11/10/03 ---------------------------------------------------------------------------- Special Notes and Comments NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND'HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD##2394 PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 1'7, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR° EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING'SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED'GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORMFOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTORS) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS�AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE .TREATED, OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. --------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003307 Date 11/10/03 --------------------------------------------------'-------------------------- Special Notes and Comments WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED�GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITIONSOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES -----------------------------------------------------------=--------------- - Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total ------------------- BUILDING DE I i APPLICANT: Charged Paid 616.00. 616.00 .00 .00 750.00 750.00 1366.00 1366.00 Credited Due .00 .00 .00 .00 .00 .00 .00 .00 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979) 764-3570 FAX: (979) 764-34'96 ---------------------------------------------------------------------------- .I Application Number . . . . . 03-00003308 Date 1.1/10/03 Property,Address . . . . . 303 SAPPHIRE DR Property ID . . . . . . . . . 585200-0304-0110 Application description . . . TEMP POLE Subdivision Name . . . . . STONE FOREST PH 3 PropertylUse . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor -------- -- --------------- ------------------------ JOHNSON INVESTMENTS INC - WOOTAN HOMES PO BOX 800 CHAD WOOTAN COLEMAN TX 768340800 611 CASTLEBROOK COLLEGE STATION TX 77845 (979) 696-8975 ----------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 11/10/03 Valuation . . . . 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 - - - - - - - - - Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Permit Fee Total 20.00 20'.00 Other Fee Total 45.00 45.00 Grand.Total 65.00 65.00 J - - - - - - - - - - - - - - - - - - - - - - - - BUILDING DEPT REPRESENTAT APPLICANT: Credited .00 .00 .00 Due .00 .00 .00 E1k 5 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US h ADDRESS/LOCATION: l 1 LOT �BLOCK _ SUBDIVISION . Tim. Fa Office Ux Ony DATE. '� APPLICATION# �///�� 3 ✓� J/ TEMP POLE # 0 ✓ - 33a SEC/PHM: BUSINESS/OWNER NAME:PHONE: 6+96- Q"Q7,r CONTRACTOR/HOMEOWNER: PHONE: CONTRACTOR ADDRESS: poi ( Co-t N•e K ELECTRICIAN: �•bstD.r�%ramPLUMBER: P11 � �HVAC: 'r Ile —no"— %Grsl � GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX Plans REMODEL/RENOVATION SWIMMING POOL ) DESCRIPTION OF WORK: -P-i STRUCTURE USE: J+ HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: b TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ I VALUATION: $_ XPP9&�- TOTAL AREA: 3091 HEATED AREA: 1;6-19�% (Cost of Labor and LM'ateeriials) 17 PUBLIC SEWER 151 j D 4 NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �. r tt SEWER TAP: I sIZ� t 'WATER TAP: SIZE OTHER TAP: SIZE EMP POLE GARAGE TYPE: SINGLE a INTERIOR WALL TYPE: 5Ll-re4be- C. EXT OR WALL TYPE: is oa _ /Rpt.ic FOUNDATION TYPE: S ROOF TYPE: DOUBLE [ - TRIPLE ATTACHED Eg—oETACHED ARP�RT a SIGNATURE OF APPLICANT: Plans Examiner Official Use Only Zoning Official ents. YES r NO Energy Code Compliance Information %Glazing of exterior walls Insulation R value of exterior walls ,t Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulied-areashio attic) Glazing SHGC Glazing U-Factor R value of ductwork r A/C SEER rating "A .s sit - .Energy Code Compliance Information % Glazing of exterior walls 13 • �G / 4 Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) 3 0 / Insulation R value of ceiling 2 (vaulted areas/no attic) l Glazing SHGrC 3g Glazing U-Factor •''� R value of ductwork A/C SEER rating i REScheck Compliance Certificate 2000 IECC REScheckSoflware Version 3.5 Release le Data filename: Untitled.rck CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11/05/03 DATE OF PLANS: 11/02/03 f PROJECT DESCRIPTION: Lot 11, Block 4 Stone Forest Phase III DESIGNEWCONTRACTOR: Wootan Homes COMPLIANCE: Passes Maximum UA = 619 Your Home UA = 546 11.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.38 f Ceiling 1: Cathedral Ceilin.g (no attic) Ceiling 2: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.38 ti Door 1: Glass 1 SHGC: 0.38 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 319 19.0 0.0 17 1975 0.0 30.0 61 2584 13.0 0.0 181 340 0.750 _. 255 42 0.750 32 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, aod,other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release le (formerly MECchecl) and to comply with the mandatory requirements listed in the IVIScheckInspection Checklist. _ ( Builder/Designer Date 11