HomeMy WebLinkAbout09-00100066- 00076440Water System Report for Castle Rock Subdivision Phase 4 College Station, Texas November, 2009 Prepared Bv. HARLE ENGINEERING COMPANY 3002 Texas Avenue South College Station, Texas 77845 979.693.7191 /�-Jro 7 F' tS�� General Information Location: Castle Rock Subdivision, Phase 4, Lots 32 -55, Block 2 and Lots 34 & 35 Block 3, is located adjacent to Castle Rock Parkway and existing Phases 1 A, 2A and 2B of the Castle Rock Subdivision. General Note: The water line to serve these 26 residential lots will be a 8" line along Rocky Vista Drive that will connect to the existing 8" water line on Castle Rock Parkway. A proposed 6" line along Rocky Mountain Court that connects to the proposed 8 ". This line reduces to a 4" line after the proposed fire hydrant on the 6" line. The waterline layout is shown on Exhibit A. Land Use: Single family residential Design Criteria/Analysis Fire Flow: 1,000 gpm for Signle Family Residential Dometic Use 1.5 gpm per lot for Single Family Residential The proposed 8' and 6" water lines are in accordance with the Revised Water System Report for the Castle Rock Subdivision prepared in July 2007. This report provides the results of the water system analysis under the fire flow and domestic demand requirements which produced the lowest pressure in the system. The scenario with the lowest pressure was with the fire flow of 2,500 gpm in the commercial area of the Subdivision. This scenario resulted in a residual pressure of 73 psi which is significantly higher than the 35 psi minimum residual pressure required. All scenarios using 1,000 gpm for the fire flow for the hydrants in the residential sections resulted in higher residual pressures. Additional analysis of Phase 4 of the Subdivision was performed for this report to verify that the previous analysis results could be confirmed. Attached is a field fire hydrant flow test, marked Exhibit B, performed by the City of College Station on July 2, 2008. The fire hydrant was located in Phase 2A of the subdivision and the results of the test yielded a flow of 1,300 gpm at a residual pressure of 94 psi. A KYPIPE computer model was developed for the proposed waterlines for the Castle Rock Subdivision, Phase 4. The model was run using a fire flow of 1,000 gpm for the proposed Fire Hydrant on Rocky Mountain Court. A maximum daily demand of 39 gpm was also used in the analysis. The starting residual pressure was based on the fire hydrant flow test. The node and pipe locations are shown on Exhibit A. Exhibit C is the KYPIPE output file with the domestic peak flow and the fire flow from the hydrant. All node pressures exceed 90 psi for this scenario which is greater than the 20 psi minimum required. All the pipe velocities are less than 12 fps for this scenario. The maximum velocity is 11.7 fps in the 6" line. Exhibit D is the KYPIPE output file with only the domestic peak flow modeled. All node pressures exceed 100 psi for this scenario which is greater than the 35 psi minimum required. Conclusion The proposed 8 ", 6" and 4" water lines meet or exceed all of the design criteria for the City of College Station. It will provide adequate water pressure, flowrate and velocity for both domestic and fire flow demands. F- 1 m /I X W N� lLLJ,ry Z ry O Z r =Q O V) Q w z W a n 0 a m d'Z O V W — LJ YQF- � U 2 O a- (n >- �,- Of w (n 0 �\ -, F- J LLJ N .y Q U f , r cl \ \ I W l -i At 1 I Y Colleg Station Utilities Reliable, Affordable, Community Owned Date Wednesday, July 02, 2008 Time 1:45 Test completed by Matthew Matcek Witness Aaron Matthews Location Castlerock Ph 2A Nozzle size 2.5 Flow hydrant R -057 Pitot reading 60 G.P.M. 1300 Static hydrant R -056 Static PSI 100 Residual PSI 94 Comments Initial CR4B.ouT 1 FLOWRATE IS EXPRESSED IN GPM AND PRESSURE IN PSIG A SUMMARY OF THE ORIGINAL DATA FOLLOWS 0 PIPE NO. NODE NOS. LENGTH DIAMETER ROUGHNESS MINOR LOSS K (FEET) (INCHES) 1 0 1 1.0 8.0 150.0 .00 + 2 1 2 89.0 8.0 150.0 .00 3 2 3 183.0 6.0 150.0 .00 4 3 4 422.0 4.0 150.0 .00 03UNCTION NUMBER DEMAND ELEVATION CONNECTING PIPES 1 .00 284.00 1 2 2 6.00 284.00 2 3 3 1012.00 280.00 3 4 4 21.00 280.00 4 OUTPUT SELECTION: ALL RESULTS ARE OUTPUT EACH PERIOD FIXED GRADE 505.00 0 THIS SYSTEM HAS 4 PIPES WITH 4 JUNCTIONS , 0 LOOPS AND 1 FGNS 1 THE RESULTS ARE OBTAINED AFTER 2 TRIALS WITH AN ACCURACY - .00000 OCastle Rock Phase 4 10/30/09 File CR46 7NH Proposed water System w/ FGN (94 psi, 505' msl) at castle Rock Dr. 8" WL Pk. Demand of 1.5 gpe /con and 1000 gpm Fire Flow at FH at Node 3 0 PIPE NO. NODE NOS. FLOWRATE HEAD LOSS PUMP HEAD MINOR LOSS VELOCITY HL /1000 1 0 1 1039.00 .02 .00 .00 6.53 15.04 2 1 2 1039.00 1.34 .00 .00 6.63 15.04 3 2 3 1033.00 11.06 .00 .00 11.72 60.42 4 3 4 21.00 .14 .00 .00 .54 .32 0 JUNCTION NUMBER DEMAND GRADE LINE ELEVATION PRESSURE 1 .00 504.98 284.00 95.76 2 6.00 503.65 284.00 95.18 3 1012.00 492.59 280.00 92.12 4 21.00 492.45 280.00 92.06 THE NET SYSTEM DEMAND = 1039.00 SUMMARY OF INFLOWS(+) AND OUTFLOWS( -) FROM FIXED GRADE NODES PIPE NUMBER FLOWRATE 1 1039.00 THE NET FLOW INTO THE SYSTEM FROM FIXED GRADE NODES = 1039.00 THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES = 00 95.76 2 6.00 503.65 284.00 95.18 3 1012.00 492.59 280.00 92.12 4 21.00 492.45 280.00 92.06 THE V.- Page 1 1 FLOWRATE IS EXPRESSED IN GPM AND PRESSURE IN PSIG CR4A.OUT A SUMMARY OF THE ORIGINAL DATA FOLLOWS 0 PIPE NO. NODE NOS. LENGTH DIAMETER ROUGHNESS MINOR LOSS K FIXED GRADE (FEET (INCH 1 0 1. 150.0 .00 + 2 1 2 89.0 8.0 150.0 515.00 3 2 3 183.0 6.0 150.0 .00 4 3 4 422.0 4.0 150.0 .00 .00 03UNCTION NUMBER DEMAND ELEVATION CONNECTING PIPES 1 .00 284.00 1 2 2 6.00 284.00 2 3 3 12.00 280.00 3 4 4 21.00 280.00 4 OUTPUT SELECTION: ALL RESULTS ARE OUTPUT EACH PERIOD 0 THIS SYSTEM HAS 4 PIPES WITH 4 JUNCTIONS . 0 LOOPS AND 1 FGNS 1 THE RESULTS ARE OBTAINED AFTER 2 TRIALS OCastle Rock Phase 4 WITH AN ACCURACY = .00000 Proposed Water System vk'/ FGN (100 psi, 515' 10/30/09 msl) at castle Rock Dr. File CR4A INH 8" WL Pk. Demand Of 1.S gpm /con 0 PIPE NO. NODE NOS. FLOWRATE HEAD LOSS PUMP HEAD MINOR LOSS VELOCITY HL /1000 1 0 1 39.00 .00 .00 .00 .25 2 1 2 39.00 3 .00 .DO .00 .03 .25 .03 2 3 33.00 4 3 .02 .00 .00 .37 .10 4 21.00 .14 .00 .00 S4 .32 �t 0 JUNCTION NUMBER DEMAND GRADE LINE ELEVATION PRESSURE 1 .00 515.00 284.00 100.10 2 6.00 515.00 284.00 100.10 3 12.00 514.98 280.00 101.82 4 21.00 514.84 280.00 101.77 THE NET SYSTEM DEMAND - 39.00 SUMMARY OF INFLOWS( +) AND OUTFLOWS( -) FROM FIXED GRADE NODES PIPE NUMBER FLOWRATE 1 39.00 THE NET FLOW INTO THE SYSTEM FROM FIXED GRADE NODES = 39.00 THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES = 100.10 .00 2 6.00 515.00 284.00 100.10 3 12.00 514.98 280.00 101.82 4 21.00 514.84 280.00 101.77 THE w .., Page 1