HomeMy WebLinkAbout14-391 TDI-Brooks International Center South Dowling RdPARKING ANALYSIS I D. CAI CALLE6 21.19 A* TNgCT \ UTLfTY DEMAND 37 /' 01NPEPZ NE A- WATER1161,4 � I\ I DEMAND REQUIRED PARKING: �T 163, 4T , MINIMUM 0 GPM - - 5 2 f I AVERAGE 13 GPM 9,583 SF OFFICE - MAXIMUM (PEAK) 52 GPM 1 SPACE PER 250 SF L 1 2" DOMESTIC WATER METER 40 SPACES *NOTE: 2" METER SIZE NEEDED FOR BOTH 40 SPACES REQUIRED TOTAL l I 2 HANDICAP SPACE REQUIRED f'r / �\� j� 50' I �A I BUILDINGS T SABA SANITARY SEWER DEMAND PROPOSED PARKING: ON -SITE SEWAGE FACILITY (OSSF) 18 SPACES PARKING I l / / J / I DESIGN PARAMETERS: 2 SPACE HANDICAP PARKING 20 SPACES TOTAL A LAB FACILITY OF APPROXIMATELY 10,000 SF NOTE: WITH 30 EMPLOYEES 91 12 GPD AND AN A PARKING SPACE REDUCTION WAS OFFICE FACILITY OF APPROXIMATELY 10,000 SF REQUESTED BY LETTER DATED WITH 30 EMPLOYEES 01 5 GPD, WITH WATER OCTOBER 12, 2011 AND WAS SAVING FIXTURES, ON A 51.994 ACRE TRACT, APPROVED BY STAFF. THIS REQUEST \� %i -J Q=30 EMPLOYESS x 12 GPD + 30 EMPLOYEES PROPOSED A TOTAL OF 61 SPACES, 41 5- 360 + 150 = 510 GPD, RTHE BLABORATORY AND Ra0.04520FOR THEOFFICE BUILDING. A=Q/Ri=510 GPD/0.015=11,333 SF REQUIRED N/F ti / � / / A=4(31'x31'x3.14)=12,070 SF DESIGNED DAVID GOLD AND TERESA GOLD p f/''� �� I ) (RE � I / 10.0543 ACRE TRACT >l / / % s BAc / 3253/54 EXISTING / / \ CITY LIMIT LINE UNPLATTED POND ZONED A-0 �S€TBAGK-- / ,�-- 24' P.�E. \k (Vol. IDE S BACK/ / 20' P U.E. 1 ` \ J� N/F B(y0C _ \ \ \ �/ / J / ' Ip� I IRMA JOSEPHINE BENTON A, J�D /�/ \\\\� ` `� QP9 / r CALLED 15.41 ACRE TRACT EXISTING ��REAMIT 1.v " / / 362/473 12" WATERLINE UNPLATTED `` SIDE J / / �- l ; D / / /+ �- -- \ �\ \ I /& G( `-STREE 1 I� I 0 ( I / % 1 ZONED A-0 BACK / //� \ / / -i ` \ J' / / / / ( I EXISTING .w / /DETENTION I \ POND FREE DISTURBED �� / > / ((l (l I PROP if I NE ( AREA LIMIT 1 ./ I TIGN 'I II� I I / I / �OSfD / SIGN 1 ® \ LOf u, BLV 1 Fl 1 1 -- ( FPZ o G 51.719,�CR to ��\`I \\� ��JQ .815 3F ) s l FIRE `zLa N E D -O / , -� __20' P.U.E. Sy i� �`� / 5 B �/ vol. \ /�� - 6/ / NT.LDG / \ � LANE ® / EX� STING1/r� ® _ SIGN P9 ) 12" W�/1ER INE ,` J �3 / % I z�\ 1'4 7 /� / �DFIR'9 NE \, / is S / FIR / '° a �/ y-� gam' tj\19tNC' ` r �/ SIG e' �/ C� 6 SF LANE DIS�TURBE / I AEA LIMIT ip -� OPOS� p�5 95tCC• ����ti SNEXI ING ` \ �.,� � � (� PR .33 �G' �� � # ��ANYFIRE �. % ,; '`�� / / fFIRE / 25 6 // _s FIR HYDRLANE ! / / N 20• P r'. • SIGN IRRIGAT1 L M WIDTH V',IES �METER FIRE \� (9• �L-) 3LAN E �Z/ / FI NE _WATER ® \ SIGN ` ® \ g•� ,�// �-� - h�`��� N \ METE X. \ r/ _ FIRE / VALVE \ D11�IrRB D �� tI �� \ REA TIT / / z °"� ' Lam- - LANE XISTING - OSSF I \ Q z� M� / FIRE SIGN FIRE NYD NT SPRAY C LIMIT \� �- _,`` � z�- � LANE � FIELDS\ / CIL ( 1 ^' LINE �\ / �^� �ry 15' P.U.E.N EXISTIN / ✓ ' ` I / (Vol. WATERLINE `P19 --- / FIRE - LANE -� I SIGN \ EXISTING \\\\ \ 1\ \ 50' 6" WATERLINE \ �\ \ FRONT v , 9 \ • \ �\ .•� SETBACK �• \ ' - f - EXISTING FIRE /f ( EXISTING DISTURBED LANE BUILDING EXISTING DRIVEWAY DRIVEWAY �s �\ '� SIGNS I 16,324 SF Q I N/F - P.U.E. AREA LIMIT �- i \ \ (Vol. �- \ ' ✓ it EPTING, RICHARD GLENN JR \ P9• -) 20' BTU ELECTRICAL �� lJ LOT 11 100 50 0 100 9 \ \ \ EASEMENT, 9424/206 EXISTI / / - - / / I �SHILOH SUBDIVISION 289/219 & 9424/274 SCALE IN FEET II f �/ I \ UED FOi B COMPLIANCEIQ 1 J /Q �lh /r 20' P.U.E. ~ \ G / / J �'� \ �� \ \ (oL P.u.E. / j `) LANE ���� = (col. _ FEB 0 6 SIGN ��-`�� � J)' --�9- --) \ \� � � �� �/ -- ��� � � - � CC)LL��� :� � � � ION I LEGEND \ �, \\ EXISTING �J / ^ - \ ENGINEERING GENERAL NOTES: 1. ALL RADII AND DISTANCES ARE MEASURED TO THE BACK OF CURB UNLESS OTHERWISE NOTED. 2. PAVEMENT DEPTHS: REFER TO SHEET C2 FOR PAVEMENT DEPTHS. 3. THE TOPOGRAPHY SHOWN IS FROM FIELD SURVEY DATA AND AERIAL TOPOGRAPHY PREPARED IN 2005. 4. CONTRACTOR IS TO VERIFY THE EXACT LOCATION AND VERTICAL POSITIONING OF EXISTING UTILITIES AND SERVICE LINES WITHIN THE PROJECT AREA, WHETHER SHOWN 014 PLANS OR NOT, AT LEAST 48 HRS. PRIOR TO ANY CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE DONE TO EXISTING FACILITIES. CALL 1-800-DIG-TESS. 5. ALL UTILITY LINES (WATER, GAS, SANITARY SEWER, VERIZON, STORM SEWER, ETC.) SHOWN ARE TAKEN FROM BEST AVAILABLE RECORD INFORMATION BASED ON CONSTRUCTION UTILITY MAP DOCUMENTS OBTAINED BY FROM CITY & INDEPENDENT AGENCIES AND/OR ABOVE GROUND FIELD EVIDENCE. SHOWN POSITIONS MAY NOT REPRESENT AS -BUILT CONDITIONS. 6. BUILDING SETBACK LINES SHALL BE IN ACCORDANCE WITH THE CITY OF COLLEGE STATION UNIFIED DEVELOPMENT ORDINANCE. 7. ALL ROOF AND GROUND -MOUNTED MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW OR ISOLATED SO AS NOT TO BE VISIBLE FROM ANY PUBLIC RIGHT-OF-WAY OR RESIDENTIAL DISTRICT WITHIN 150' OF THE SUBJECT LOT, MEASURED FROM A POINT 5 FEET ABOVE GRADE. SUCH SREENING SHALL BE COORDINATED WITH THE BUILDING ARCHITECTURE AND SCALE TO MAINTAIN A UNIFIED APPEARANCE. 8. PROPOSED SIGNS SHALL BE PERMITTED SEPARATELY IN ACCORDANCE WITH THE LIDO. LINE TABLE LINE # LENGTH DIRECTION L7 217.74' S68' 24. 47-W L2 206.97' S70. 01' 48"W L3 110.13' S71' 40' 52'W L4 108,61' S75' 43' 32'W L5 215.99' S82' 48' 15'W L6 98.89, S83. 56, 08"W L7 159.46' S85' 44' 30"W L8 134.33' N87' 32' 32'W L9 149.16' N82' 15' 23'W Curve Table CURVE LENGTH RADIUS I DELTA I TANGENT I CHORD I CHORD DIRECTION Cl 209.65' 2814.67' 004-16'04" 104.87' 209.60' S24'13'35"E EXISTING DRIVEWAY SITE SPECIFIC NOTES: 1. THE OWNER OF THE PROPERTY IS GE03, INC THE SUBJECT PROPERTY IS LOT 1, BLOCK 1 OF THE TDI-BROOKS INTERNATIONAL CENTER, PROPERTY IS ZONED AO - AGRICULTURE OPEN. 2. PROPOSED BUILDING A IS 1 STORY, 20' HIGH, 9,583 SF AND FF=330.5'. 3. THE DISTURBED AREA FOR THIS PROJECT IS 7.773 ACRES (338,594 SF). THIS AREA MATCHES THE DISTURBED AREA FOR THE LABORATORY BUILDING SITE PLAN. 4. THIS TRACT DOES NOT LIE WITHIN A DESIGNATED 100 YEAR FLOOD PLAIN ACCORDING TO THE F.I.R.M. MAPS, COMMUNITY PANEL NO. 48041 CO200-C, EFFECTIVE JULY 2, 1992. 5. DRAINAGE INFORMATION AND DETAILS WILL BE PROVIDED ON THE GRADING AND DRAINAGE PLANS. 6. THE IRRIGATION SYSTEM MUST BE APPROVED AND INSTALLED PRIOR TO C.O. 7. THERE IS A FIRE SPRINKLER SYSTEM PROPOSED FOR THIS BUILDING. THE BUILDING IS 9,583 SF TYPE IIIB CONSTRUCTION AND ACCORDING TO IFC TABLE 8105.1 "MINIMUM REQUIRED FIRE -FLOW AND FLOW DURATION" THIS BUILDING REQUIRES 2,250 GALLONS PER MINUTE. THE BUILDING'S FIRE SPRINKLER SYSTEM ALLOWS FOR A 50% REDUCTION IN THAT REQUIREMENT (1,125 GALLONS PER MINUTE). THE MINIMUM REQUIRED FIRE FLOW FOR A COMMERCIAL BUILDING IS 1,500 GALLONS PER MINUTE. ACCORDING TO IFC TABLE C105.1 "NUMBER AND DISTRIBUTION OF FIRE HYDRANTS" A 1,500 GPM FIRE LOW REQUIRES ONLY ONE FIRE HYDRANT. 8. TRAFFIC IMPACT ANALYSIS IS NOT REQUIRED. 9. ALL SITE WORK IS TO BE DONE IN CONFORMANCE WITH THE BRYAN / COLLEGE STATION 2• ;0 STANDARD SPECIFICATIONS FOR WATER &SEWER AND THE CITY OF COLLEGE STATION STANDARD SPE` : iCATIONS FOR STREETS & DRAINAGE. 10. EXTERIOR LIGHTING FOR THE SITE WILL BE IN ACCORDANCE WITH THE UNIFIED DEVELOPME'r ORDINANCE. 11. 20 PARKING SPACES ARE PROVIDED FOR THIS SITE AS ALLOWED BY THE PARKING REDUCTION REQUEST FOR THIS SITE. 12. THIS LOT WILL BE SEWERED BY ON -SITE SEWAGE FACILITIES (OSSFs) WHICH MUST COMPLY WITH ALL COUNTY & STATE OSSF REGULATIONS.. ALL OSSF CONSTRUCTION MUST HAVE AN "AUTHORI: ATION TO CONSTRUCT" PERMIT ISSUED BY THE BRAZOS COUNTY HEALTH DEPARTMENT. THIS PERMIT E'SURES COMPLIANCE WITH THE COUNTY ORDER ADOPTED BY THE COMMISSIONERS COURT OF BRAZO- COUNTY, PURSUANT TO THE PROVISIONS OF SECTION 21.084 OF THE TEXAS WATER CODE. ON -SITE SEWAGE FACILITIES DISPOSAL AREAS SHALL NOT ENCROACH THE 100 FOOT OR THE 150 FOOT SANITARY ZONE OF A PRIVATE OR PUBLIC WELL, RESPECTIVELY. 13. ELECTRICAL SERVICE FOR THIS SITE IS PROVIDED BY BRYAN TEXAS UTILITIES, BTU. 14, TDI BROOKS INTERNATIONAL CENTER IS TO BE CONSIDERED ONE BUILDING PLOT FOR THE PURPOSE OF SIGNAGE, NON-RESIDENTIAL ARCHITECTURAL STANDARDS, AND LANDSCAPING IN ACCORDANCE wITIi ORDINANCES REGARDING BUILDING PLOTS OVER 50,000 SQUARE FEET IN AREA. 15. THE FOLLOWING BLANKET EASEMENTS APPLY TO THIS TRACT: -CITY OF BRYAN 144/108 -WELLBORN WATER SUPPLY CORP. 303/288 -CITY OF BRYAN 548/539 AT THE TIME OF THE FILING OF THIS PLAT, THE BLANKET EASEMENTS DO APPLY. THESE EASEMENTS ARE BLANKET IN NATURE AND HAVE NO DEFINED DESCRIPTION. 16. NO HAZARDOUS MATERIAL MAY BE DISPOSED IN THIS SITE'S SANITARY SYSTEM. 17. A KNOX BOX WILL BE PROVIDED FOR THIS BUILDING AND THE OWNER WILL BE ADVISED OF A KNOX SWITCH FOR GATED ENTRANCE, IF PROVIDED, 18. THE REQUIRED PARKING ISLAND SQUARE FOOTAGE IS CALCULATED BY THE FORMULA: (# OF PARKING SPACES/15)*180. WITH 20 PARKING SPACES THIS SITE REQUIRES 240 SQUARE FEET OF PARK.iNG ISLANDS. THE PROPOSED PARKING LOT EXCEEDS THE REQUIRED AMOUNT. 19. THE DRIVEWAY AT I&GN WILL REQUIRE A PERMIT FROM THE BRAZOS COUNTY ROAD AND BRIDGE DEPARTMENT. 20. EXTERIOR BUILDING AND SITE LIGHTING WILL MEET THE STANDARDS OF SECTION 7.10 OF THE UNIFIED DEVELOPMENT ORDINANCE. 111E LIGHT SOURCE SHALL NOT PROJECT BELOW AN OPAQUE H6U8ING AND NO FIXTURE SHALL DIRECTLY PROJECT LIGHT HORIZONTALLY. FIXTURES WILL BE MOUNTED IN SUCH A MANNER THAT THE PROJECTED CONE OF LIGHT DOES NOT CROSS ANY PROPERTY LINE. P Al �^ l DRIVEWAY TO TO BE 9�M REMOVED SKETCH OF EXISTING DRIEWAYS N.T.S. NOTE: ALL CURBS 6' IN HEIGHT UNLESS NOTED OTHERWISE. 1 /4"R 24" 6" 15" - 3" --284- --- -- EXISTING CONTOUR. LOT BOUNDARY FIRE HYDRANT 4 GATE VALVES W-8 EXISTING WATER LNE 0 EXISTING TREE mm ® ® w= an Em ® ® ®® CITY LIMIT LINE DISTURBED AREA LIMIT -�T-�*--�*--�T-- PROPOSED STORM SEWER PIPE DITCH FLOWLINE :4 30161 Lei 04 DETENTION / / POND FIRE � ANE � �\\\\ 20' L - \ / SIGN SIDE -� \1 \ SETBACK/.�...........�.c" r "e..,... :> 20' P.U.E. \\\\\ iEE L�`� DRIVEWAY Fl Vol. -/ / ��C '' fCL, . TVA'm TO BE REMOVED \ SI\ P9 REQUIRED l Q EXISTING �� \ - N/F WATER / / CHARLES MICHAEL FULFER AND i! 0 �, ,2_ SERVICE \ \� / \ WIFE, KAREN MARIE FULFER DRIVEWAY TO BE n .REMOVED � V SCHULTZ ENGINEERING LLC THE SEAL APPEARING ON DOCUMENT WAS AUTHORIZED THISBY JOSEPH P. SCHULTZ, P.E., LICENSE TBPE NO. 12327 NO. 65889 ON JANUARY 20, 2012. 2730 Longmir e, Suite A RELEASED FOR CONSTRUCTION College Station, Texas 77845 979.764.3900 SURVEYED DESIGNED DRAWN APPROVED JOB NO. DATE KERR JPS RCF JPS 11-189 JANUARY 2012 CALLED 5.00 ACRE TRACT 10087/194 UNPLATTED ZONED A-0 JOSEPH P.SCHULTZ 65889 . . -vv"'",wv7- I,/{HIIiG}�i �l FIRM # 12327 TZ ENGINEERING, LLC mmmummmmmmmmmmoo TDI-BR 0 OKS INTERNATIONAL CORPORATE HEADQUARTERS OFFICE BUILDING SOUTH DOWLINC ROAD, COLLEGE STATION, TEXAS 1/4"R-I-� 5" 12" 'T' ,yQ- 1 �. 3" " 2' K. CK.I "'E • - # BARS FEB 06 2012 0 - 3/4• X 18" SM TH. EXP NSION DO ��Ld-L.� 17_ 0 b ytl � 'N DEV1`1,"0P E.NT 9�.���V1(,'E TYPICAL CURB DETAIL PI,_AT rig ED. N.T.S. c�Trci r�rn.,rnr�rour. r�•r. r. .. EMENT 8" LIME STABILIZED SUBGRADE (EXTENDS 1' OUTSIDE THE EDGE OF PAVEMENT) * X=6" OR 7' AS SHOWN ON THE PLAN (SHEET C2) * 6" PAVEMENT - USE #3 REBAR ® 12" O.C.E.W. OR USE #4 REBAR ® 16" O.C.E.W. * 7" PAVEMENT - USE #4 REBAR 0 16" O.C.E.W. TYPICAL CONCRETE PAVING SECTION N.T.S. SITE' PLAN SHEEP' 1 OF 2 CITY N NOT TO SCALE DRIVE AY TO B it �1 TDI-BROOKS INTERNATIONAL CENTER BLOCK 1, LOT 17 51.719 ACRES ANDREW McMAHAN SURVEY, A-167 COLLEGE STATION, BRAZOS COUNTY, TEXAS SCALE: 1 "=100' DECEMBER 2011 OWNER: ENGINEER: GE03, Inc. SCHULTZ ENGINEERING, LLC. 14379 South Dowling Road TBPE Firm Reg. No. 12327 College Station, TX 77845 (979)693-3446 9-730 Longmir e Drive, Suite A College Station, Texas 77845 SURVEYOR: P. 0. Box 11995 College Station, Texas 77342 Brad Kerr, R.P.L.S. No. 4502 979.764.3900 Kerr Surveying, LLC 505 Church Avenue (979) 690-7250 SCALE VERTICAL n/a HORIZONTAL 1 "=100' PLOTTING SCALE: 1:1 FILE NAME: 11-1 RA SHEET ¢''4. PROPOSED LAB / a" / 32 /s. / BUILDING �.•: / ` -� 6 \ FF=330.5 / \ / 32 r 9,815 SF 323-- � tr 6/ , / 25' BLDG. HT. S �1S 1S — 1S is is is MINI,, t DISTURBED —32 f4�i / AREA LIMITI.� IFINN — TREE TO BE / \ 328 --I LJ 1S is is 1S 1S 1S V =_1S — _S TREE TO BE--, U) REMOVED PROPOSED OFFICE BUILDING FF=330.75 - 9,583 SF 328 25' BLDG. HT. � � — —'- / J DOMESTIC EQUIPMENT EQUIPMENT / / WATERLINE\ YARD YARD w/ SCREEN / SCREEN FIRE q i„ WALL WALL SPRINKLER \ _ SUPPLY LINE ST ST 5 5T LAJ ST — ST SST ST —0 S-6 6 S-6 T---5- S-6 S-6 S-6 S-6 S-6 SIDEWALK FINISH MATERIALS SEWER LINE / -`--TO- 8&-W-ACCORDANCE W/ I -� TO OSSF ARCH IECTURAt- RAWINGS� LANDSCAPE & N —i ELECTRICAL 330 -+ Ln SLEEVES(4-4" PVC) `REMOVED18" ' PIP HD PIPE l \ / 33 7 1 N .r32 / • • V1_6 3 S s _ S-6 30 / g x O .? • . ' LANDSCAPE ELECTRICAL OSSF\s�e SLEEVES 4' PVC) y s TANKS �- 41 / SIDEWALK '� s 30 LF F 8" ADS \ / FDC FIRE 4 �. \\ 1-, P FORS LIN !y PROPOSED SPRINKLER � \ s I 3gti \S s ADA SIGNAGE LINE ®s 932 L F OF 4" A D 5 'IRE s WATER PIPE SLEEVE LINE FOR s s LANE PROPOSED / g`� SIGN BIKE RACK / EXIST FIRE/ I 4 E E E E�- e-� - E . E E32 E 33 E_�i / �\\\ \ HYDRANT S / 4- \ FIRE t> ' e 6' \\ / \ LANE a �0 SIDEWALK i I \ \\ \ EXISTING CURB — — _-�- — -=o '' — — — — — — — — — -- — — -� M M 1 12" WATERLINE 31 l9/V ��s D e ' 32 LF OF 8" ADS \ s, '4 ° ° ` `�� PIPE SLEEVE FOR ? \ s w` ' HC �9' -� � ` = � WATER LINE/ EXISTING VALVES ON SIDEWALK FINISH MATERIALS \ ti 0 BE IN ACCORDANCE W/ 15" HDPE`' -J `� �ti / / r'p 9 A IECTURAL DRAWINGSAil -A �� „! FIRE SLEEV'ES(2-4" PVC) FDC 1" IRRIGATION LANE 1 — FIRE 11 / / 4 METER - —� �B— —33. -- -- LANE ,,; �"::'��- FIRE LANE �. CURB SIGN LANE „i �MARKING 1 SIGN z EXISTING FIRE HYDRANT �A > SEE INSET A —� 4`S°s`.:332 / LANDSC Y ::r : 41, 2" WATER METER il-M-_ZL ht Viz, a — _ 3j2 �...q, FIRE SLEEVES 4-4" PEC RICAL VC) _ --- --- __ ---�� •= • • I I EXISTING � / ISOLATION VALVE SIGN 12" WATERLINE / tis�� (SEE NOTE 7) M zt-M�_ — -� �— — — — — — — — — — — `ice' — �/ eg �i�f� DISTURBED — �_ _ AREA LIMIT — �� z1-L1------ i`j. T °° • ZI--MZL-M— _e':� 'tea / ZL-M Zl-M Zl-At Zl-M ZL-M Z i1•�� / _ aa,13 E� / +.g 1 FIRE LANE MARKINGS ALL CURBS AND CURB ENDS SH ALL BE PAINTED RED WITH FOUR INCH (4") WHITE LETTERING STATING "FIRE LANE - NO PARKING - TOW AWAY ZONE". WORDING MAY NOT BE SPACED MORE THAN FIFTEEN FEET APART. A SIGN TWELVE INCHES (12") WIDE AND EIGHTEEN INCHES (18") IN HEIGHT SHALL BE MOUNTED IN A CONSPICUOUS LOCATION AT EACI4 ENTRANCE TO THE PROPERTY AND AT THE LOCATIONS SHOWN ON SHEET C1. SUCH SIGNS SHALL BE TWELVE INCHES (12") WIDE AND EIGHTEEN INCHES HIGH, WITH A COMPANION SIGN TWELVE INCHES (12") WIDE AND SIX INCHES (6") HIGH STATING "TOW -AWAY ZONE". SUCH SIGNS SHALL BE PAINTED ON A WHITE BACKGROUND WITH SYMBOLS, LETTER AND BORDER IN RED. I PARKING KINNGG x1 12"8" reflective finish metal L� sign 12"x9" reflective finish metal sign rn Mcccsi �— 2x2 galvanized steel tube column cn set in concrete footing. Provide galvanized steel cap welded o top of tube. Paint tube and cap. '° o_ w I I 3 CD o 3 �; I '' I I All characters must be I�IJ 3 60" minimum above rode or sidewalk. ADA SIGN DETAIL VA Wi LO If SIDEWALK T — ST S 30 NOTE: ALL CURBS 6" IN HEIGHT UNLESS NOTED OTHERWISE. 1 /4"R 24" 6" 15" 3., � 1/4"R 5" 12" T 3" _ 4.. - fi 3�e� • — 3" " 3" 2" 2" -�4 3" . = # 4 BARS 0 = 3/4" X 18" SMOOTH EXPANSION DOWELS TYPICAL CURB DETAIL N.T.S. S C H U L T Z ENGINEERING L L C THE SEAL ON THIS DOCUMENT WAS AUITHORIZED BY JOSEPH P. SCHULTZ, P.E., LICENSE TBPE NO. 12327 NO. 65889 ON JANUARY 20, 2012. 2730 Longmir e, Suite A RELEASED FOR CONSTRUCTION College Station, Texas 77845 979.764.3900 SURVEYED DESIGNED DRAWN APPROVED JOB NO. - DATE - KERR JPS RCF JPS 11-189 JANUARY 2012 OF ,t d :tit JOSEPH P. SCHULTZ i�j-Zp�� Z FI M # 12327 SCHULTZ ENGINEERING, LLC STEEL REINFORCING BARS * CONCRETE PAVEMENT N.T.S. 20 10 0 20 SCALE IN FEET a IEXISTING 6" FIRE 2" GATE / SPRINKLER VALVE SERVICE LINE � 2„ \ EXISTING I DOMESTIC 6" ISOLATION WATER VALVE SERVICE / (SEE NOTE 7) # III IIII� IIIII— LII III'�C:III�IC GII� III n-�IIII I— L ��� Ilill� III IIIII If 1111= illy IIIII= IIIII II = I IIIII -�j �I�IUIIII �Illlll�il�ll��alill ._.III ' min.1R w BIKE RACK DETAIL N.T.S. -36"- CONSTRUCTION NOTES: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. NOTIFICATION OF THE UTILITY COMPANIES 48 HOURS IN ADVANCE OF CONSTRUCTION IS REQUIRED. DIG TESS: (800) 344-8377 ATMOS ENERGY: (800) 545-6005 (800) 344-8377 SUDDEN LINK COMMUNICATIONS: (979) 846-2229 VERIZON: (800) 344-8377 2. PERMANENT VEGETATION WILL BE ESTABLISHED ON THE DISTURBED AREAS AFTER CONSTRUCTION IS COMPLETE BY HYDROMULCHING AND SEEDING ALL DISTURBED AREAS. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2010 CITY OF BRYAN/COLLEGE STATION STANDARD SPECIFICATIONS AND DETAILS FOR WATER. ALL CONSTRUCTION SHALL BE COORDINATED WITH THE CITY ENGINEER'S OFFICE AND WELLBORN SUD STAFF. 4. THE CONSTRUCTION SHALL COMPLY WITH OSHA STANDARD 29 CFR PART 1926 SUBPART P FOR TRENCH SAFETY REQUIREMENTS. 5. SEE SHEET C1 FOR PAVEMENT DETAILS 6. TDI BROOKS INTERNATIONAL CENTER IS TO BE CONSIDERED ONE BUILDING PLOT FOR THE PURPOSE OF SIGNAGE, NON-RESIDENTIAL ARCHITECTURAL STANDARDS, AND LANDSCAPING IN ACCORDANCE WITH ORDINANCES REGARDING BUILDING PLOTS OVER 50,000 SQUARE FEET IN AREA. 7. THE FIRE SUPPRESSION LINE SHALL HAVE A LOCKABLE LID ON THE ISOLATION VALVE. THE LOCKABLE LID SHALL SUPPLY THE SAME PROTECTION AS THE AMP OR USA, LL562 LOCKING LID AT A MINIMUM. AN ALTERNATE LOCKABLE LID SHALL BE APPROVED BY COLLEGE STATION UTILITIES DIRECTOR OR HIS DESIGNEE. LEGEND —284— -- — EXISTING CONTOUR BOUNDARY >i FIRE HYDRANT o GATE VALVES W-8 EXISTING WATER LINE '""" — ACCESSIBLE ROUTE y' • - DITCH OR SWALE FLOWLINE -� RUNOFF FLOW DIRECTION L 7. , PROPOSED SIDEWALK EXISTING 2" WATER , 6„X2" METER I TEE 1" IRRIGATION 18" DEWNATED I PRIVATE METER 1 PAROM EXISTING PUBLIC I 6" GATE I ONLY VALVE \ •-•11 r1-12 i-12 F11 M-11 NOTES: EXISTING 1. THE SIGN SHALL BE 12" WIDE BY 18" IN \ 12"X6" HEIGHT AND BE MOUNTED IN THE LOCATION \ TEE SHOWN. \ 2. SIGN SHALL BE PAINTED ON WHITE BACKGROUND WITH SYMBOLS, LETTERS, AND t ELC BORDER IN RED. / .«ir �t+'i,; CL "p 3. SIGN SHALL COMPLY WITH THE CoCS FIRE SERVICE STANDARDS. INSET A o REQUIRED FIRE LANE SIGN DETAIL NTS ❑ " 1' N.T.S. ! NOT Rv- - EW FOP "-- 8" LIME STABILIZED SUBGRADE (EXTENDS 1' OUTSIDE THE EDGE OF PAVEMENT) * X=6" OR 7' AS SHOWN ON THE PLAN (SHEET C2) * 6" PAVEMENT - USE #3 REBAR 0 12" O.C.E.W. OR USE #4 REBAR 0 16" O.C.E.W. * 7" PAVEMENT - USE #4 REBAR ® 16' O.C.E.W. TYPICAL CONCRETE PAVING SECTION N.T.S. TDI-BR 0 OKS INTERNATIONAL CORPORATE HEADQUARTERS OFFICE B UILDING SOUTH DOWLING ROAD, COLLEGE STATION, TEXAS (30. . tl tn 1= a 6 ?012 \J\, 3 Sg. ¢ iif4°� CVha4."�..t ].m '�~!� ,1,Ii+ I o n IN PLAT FILED: SITE PLAN SHEIs T 2 OF 2 SCALE VERTICAL n/a HORIZONTAL 1"=20' PLOTTING SCALE: FILE NAME: 11-189 SHEET Legal Description: Lot 1, Block 1 TDI Brooks International Center 53.308 acres Zoned A-0 Owner: GE03, Inc. 1902 Pinon Drive College Station, TX 77845 (979)693-3446 This site does not lie within the established area of the special flood hazards as established by the current flood insurance study or flood insurance rate map, panel number #48041CO200C TDI Brooks International Center is to be considered one building plot for the purpose of signage, Non -Residential Architectural Standards, and landscaping in accordance with ordinances regarding building plots over 50,000 square feet in area. 5 PROJECT INFORMATION West elevation materials Natural limestone 616 sf 25% Stained wood siding 162 sf 6% Doors and windows 1608 sf 65% Stained wood columns/brackets 85 sf 4% Total 2471 sf Metal roofing Window with overhang — Window with overhang Column — Metal awning Column Stone screen wall !i i i ;i 4 2 12 8� r Wall plane recession - Column— ,,} North elevation materials Not visible from right-of-way Natural limestone 1029 sf 88% - Stained wood siding 0 sf 0% Doors and windows 118 sf 10% Stained wood columns/brackets 20 sf 2% Total 1167 sf South elevation materials Natural limestone 1071 sf 91% Stained wood siding 0 sf 0% Doors and windows 76 sf 7% Stained wood columns/brackets 20 sf 2% Total 11167 sf Top of Ridge +/- 24'-0" I Eave height 12'-8" Finished floor If 0'-0' Wood truss Column Porch Stone veneer Recesed entry Screen wall Column Column Canopy Porch Wall plane recess Column Metal roofin Canopy Wall plane recess (2) Pilaster Stone veneer 8:1 Elmo_ EKN BE, ^ I' 60'-0" Wall plane recession Window with overhang Column - t o�� ��e ■ � _••n•r ■ 1 � .' � ■ ado aim ���o �p5��! oe�����-�_ �■�pcan�p��u�IBo -- ad���ao � i� s� ��.�_ 1110MM �.�.. � - �_r�— ■ � �,� '--ter a.�B�.rl��.���p��acan�a�.�ra�.�■ Wood siding 1 15'-0" 415-0 45'-0" 45'-0" 36'-0" lair Gam- ��lil� ���1- .t� ►. — Column Porch - 0 ANORTH ELEVATION _r Refer to: 1 /A2.1 i 1 Scale: 1 /8"=1'-0" SOUTH ELEVATION Refer to: 1 /A2.1 Scale: 1 /8"=1'-0" L VVL 0I LLLvr-11 IVIV Refer to: 1 /A2.1 Window with overhang Column Scale: 1 /8"=1 '-0" This sheet is for the City of College Station NRA Ordinance review ONLY, and is NOT to be used for construction or material quantity estimates. Eave height 12 -8 East elevation materials Finished floor Natural limestone 855 sf 35% Stained wood siding 260 sf 10% _ Doors and windows 1276 sf 51% Stained wood columns/brackets 80 sf 4% Total 2471 sf 7 EAST ELEVATION 0 P efer to: I /A2.1 Scale: 1 /8"=l'-0" fta— ^ek_ The l► Arkitex Studio, Inc. 308 N. Bryan Ave. Bryan, TX 77803 P(979)821-2635 F(979)775-8224 www.arkitex.com qT� 00 12/16/11 N L QJ L Q) N i O Q. U O S✓ QJ C M W � � (1I O V co 0 O C O M 4- 1 V) Ned ow 0� liRevisions Number Date 1 Project 0905-C December 16, 2011 Gi • 2 of 2