Loading...
HomeMy WebLinkAboutRES2003-03774 1016 WINDMEADOWS DR BUILDING PERMITREPARED 4/21/04, 7:44:33 INSPECTION TICKET PAGE 7 itY-',of College Station -----------------INSPECTOR:-BUILDING NSPECTOR------------DATE----4/21/04 ------------------ -------- DDRRSS 1016 WINDMEADOWS DR SUBDIV:'WESTFIELD VILLAGE PH 1 DNTRACTOR : STYLECRAFT BUILDERS PHONE (979) 690-1222 WNE,R : BCS DEVELOPMENT CO PHONE :I ARCEL : 650730-0102-0160 PPL NUMBER: 03-00003774 RESIDENTIAL, 1 UNIT DETACHED NEW ----------------------------------------------------------------------------------------------- ERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION YP/SQ COMPLETED RESULT RESULTS/COMMENTS ---!---,----------------------------------------------------------------------------------------- 1001I01 1/22/04 CH BLDG, FOUNDATION -SLAB TIME: 17:00 1/23/04 AP 01/22/2004 08:00 AM MALFORD a� late this afternoon setback strings pulled slab ground back right 1 2/25/04 DP BLDG, FRAMING TIME: 17:00 2/25/04 AP 02/25/2004 11:05 AM MALFORD 13(03/Q2/04 DS BLDG, INSULATION TIME: 17:00 3/02/04 AP 03/02/2004 08:19 AM SSTANLEY 129, Q 4/21/04 BI BLDG, FINAL TIME: 17:00 4 J? 04/20/2004 01:12 PM SSTANLEY I� -I- -------------------------------- COMMENTS AND NOTES -------------------------------------- r v"ItA ;,arm k CITY OR MT.T.PMR. RTATTON WORK REQUEST PAGE 1 REQ%JOB: WF0487127 / 001 PROJECT: REQUEST DATE: 1/13/04 PRINT DATE: 1713704 CREW: PRINT TIME: 12:41:50 SCHS LOCATION: 1076 WINDMEADOWS DR ART.DATES 1/13/04 77845 COMPLETION: 1713704 GEN. LOC: COLLEGE STATION LOC ID: 195856 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE ••.,TTJt1 a 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003774 Date 12/19/03 Property Address . . . . . . 1016 WINDMEADOWS DR Property ID 650730-0102-0160 R # . . . . . . . . R113333 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 81405 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1215.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 388.00 Plan Check Fee .00 Issue Date . . . . 12/19/03 Valuation . . . . 81405 Expiration Date . . 6/17/04 Qty Unit Charge Per Extension BASE FEE 260.00 32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) - --------------------------------------------------- - ------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: �� BUILDING PERMIT CITY OF COLLEGE STATION! 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003774 Date 12/19/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RELOCATE SMOKE DETECTOR(S) TO BETTER PROTECT BEDROOMS For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND BUILDING DEPT REPRO TA VE: APPLICANT: •BUILDING PERMIT CITY OF COLLEGE STATION• 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00003774 Date 12/19/03 ---------------------------------------------------------------------------- Special Notes and Comments EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 388.00 388.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1138.00 1138.00 .00 .00 - TEMPORARY POLE PERMIT CITY OF COLLEGE STATION• 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID . . . . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00003792 1016 WINDMEADOWS DR 650730-0102-0160 TEMP POLE WESTFIELD VILLAGE PH 1 RESIDENTIAL PLANNED DEVL HOUSING 0 Date 12/19/03 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 12/19/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - CITY OF COLLEGE STATION WORIOEQUEST PAGE 1 REQ/JOB: WF0481495 / 001 PROJECT: REQUEST DATE: 12/19/03 PRINT DATE: 12/19/03 CREW: PRINT TIME: 16:06:35 SCHEDULE DATES LOCATION: 1016 WINDMEADOWS DR 77845 COMPLETION: 12/19/03 GEN. LOC: COLLEGE STATION LOC ID: 195816 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE LJ APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION LOT 1 6 BLOCK For Office Use(Only /� DATE: la- I b — 0 3 APPLICATION #0 3 -. ­2L TEMP POLE # 3r SUBDIVISION W" S' t/Pl Ay:11 hoc' PHASE BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Familv Residence HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: w TEXAS ACCESSIBILITYY STANDARD (T ) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ o 1 µ CS TOTAL AREA: � HEATED AREA: I J 15 (Cost of Labor and Materials) DX PUBLIC SEWER SEPTIC/TREATMENT SYSTEM �X SEWER TAP: �X WATER TAP: OTHER TAP: �X TEMP POLE GARAGE TYPE: 4" SIZE 3/4 e SIZE JILt NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet ROCK EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition SINGLE F—] DOUBLE 0 TRIPLE ATTACHED aX DETACHED F-1 CARPORT SIGNATURE OF APPLICANT: ��1/7 " For Stylecraft Official Use Only Plans Examiner Zoning Official pwwents: YES r NO Energy Code Compliance Information % Glazing of exterior walls 11 % Insulation R value of exterior walls R13 `/ Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 / Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\1226-1215 1016 Windmeadows.cck TITLE: PLAN #1226-1215 Porch CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 12/16/03 DATE OF PLANS: 9/15/03 PROJECT INFORMATION: Dannar 1016 Windmeadows College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANC : Passes Maximum UA = 564 Your Home UA = 461 18.3% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 864 30.0 0.0 30 Ceiling 2: Cathedral Ceiling (no attic) 380 19.0 0.0 20 Wall 2: Wood Frame, 16" o.c. 1376 13.0 0.0 96 Window 4: Metal Frame, Double Pane with Low-E 150 0.670 101 SHGC: 0.40 Door 3: Solid 38 0.500 19 Door 5: Glass 18 0.440 8 SHGC: 0.40 Floor 1: Unheated 179 0.0 187 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, • 0 and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer �/�—v ���ii Date REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 12/ 16/03 TITLE: PLAN #1226-1215 Porch Bldg. Dept. Use [ ] [ ] [ J [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 3: Solid, U-factor: 0.500 Comments: 2. Door 5: Glass, U-factor: 0.440 Comments: Floors: 1. Floor 1: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number [ ] 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ J Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. 0 • Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the I levels in Table 2. � A • C� Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Assembly Type MMJMJ��MMM Comments/ Description ©M 30O�■®■®®©®� Window Area Total: 146.83 12/16/03 16:25:28 1 /1 Area Calculator: 1=11111111111IM-1.1 Comments/ Description Opaque door solid Door Area Total: 55.56 12/16/03 16:25:28 1 /1 0 Area Calculator: M Assembly Comments/Description IEFT, 1 ■�M - I m■�■�� ®■�■�� Ceiling Area Total: 1215.00 12/16/03 16:25:29 1 /1 i i Area Calculator: Assembly Type ©�0mComments/Description- ® MMI■ ■IMIMMIN m EME■ ■IMIMMIN ® MMI■ ■IMIMMEN m EME■ ■IMIMMIN m �■ ■�� m EME■ ■IMIMMM MEN ■�■�� ® MEN■ IN ® MEN■ ■EEMININE IMEMEN ® MMI■ ■NIMMINE m■�■��INE Exterior Wall Area Total: 1360.00 12/16/03 16:25:29 1 /1 0 i Area Calculator: M' Assembly Type Comments/Description Floor Area Total: 0.00 12/16/03 16:25:30 1 /1 0