Loading...
HomeMy WebLinkAboutRES2003-03761 4411 EDINBURGH PL BUILDING PERMITCity of College Station WORK REQUEST * '+ REQ/JOB : WF0479976 / 001 PROJEC CREW: PAGE 1 QIUEST DATE: NTDATTE: 12/15/03 PRINT TIME: 14:37:08 » SCHEDULE DATES » LOCATION: 4411 EDINBURGH PL START: 12/15/03 77845 COMPLETION: 12/15/03 GEN. LOC: COLLEGE STATION LOC ID: 193256 ...r REF NBR : --«« REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL _--r REQUESTOR: CLICK HOMES ORIGIN: CUSTOMER -WALK IN " USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE „ TEMP POLE PASSED TEMP POLE PASSED Category code Task code: Facility ID . Assigned Department: CS -CUSTOMER SERVICES SET UP NEW UTILITY ACCT OT-CUSTOMER SERVICE C S PREPARED 8/24/04, 12:02:39 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/24/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 4411 EDINBURGH PL SUBDIV: CASTLEGATE SEC 1 PH 2 CONTRACTOR CLICK HOMES PHONE (979) 764-9216 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-2101-0200 APPL NUMBER: 03-00003761 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 02 1/09/04 TB BLDG, FOUNDATION -SLAB TIME: 17:00 1/09/04 AP O1/09/2004 01:18 PM GCARRILLO Strings On Setbacks O.K. Slab Ground Installed B100 01 1/09/04 DS BLDG, FOUNDATION -SLAB TIME: 17:00 1/09/04 DP O1/08/2004 09:59 AM SSTANLEY Not Ready For Inspection B111 01 2/05/04 TB BLDG, FRAMING TIME: 17:00 2/16/04 AP 02/05/2004 10:45 AM MALFORD NEEDS ALL INSPECTIONS B130 01 2/19/04 TB BLDG, INSULATION TIME: 17:00 2/19/04 AP 02/18/2004 01:05 PM MALFORD B125 01 8/ 4/q4 BLDG, FINAL TIME: 17:00 Qp�aN/+y B P Off- 08/24/2004 10:58 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES-------------------------------------- 1 C s. bA-4; CITY OF COLLEGE STATION WORK REQUEST I IPAGE 1 REQ/JOB: WF0493479 / 001 PROJECT: REQUEST DATE: 2/10/04 PRINT DATE: 2/10/04 CREW: PRINT TIME: 8:28:16 ES LOCATION: 4411 EDINBURGH PL SCHEDULE START:DAT2/10/04 77845 COMPLETION: 2/10/04 GEN. LOC: COLLEGE STATION LOC ID: 193256 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: CLICK HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT CITY OF COLLEGE STATIO � 110' _�'P,XAS AVE - .. COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003761 Date 12/18/03 Property Address . . . . . . 4411 EDINBURGH PL Property ID . . . . . . . . . 184200-2101-0200 R # . . . . . . R111141 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 169224 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD CLICK HOMES 4490 CASTLEGATE DR SHERMAN CLICK COLLEGE STATION TX 778453388 P 0 BOX 10261 COLLEGE STATION TX 77842 (979) 764-9216 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2564.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 670.00 Plan Check Fee .00 Issue Date . . . . 12/18/03 Valuation . . . . 169224 Expiration Date . . 6/16/04 Qty Unit Charge Per Extension BASE FEE 460.00 70.00 3.0000 THOU BLDG, VAL 100001-500000 210.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL E UIPMENT ----- -----------------A ----`-- - ---------------------- BUILDING DEPT W RESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOD* 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003761 Date 12/18/03 ---------------------------------------------------------------------------- Special Notes and Comments NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RELOCATE SMOKE DETECTOR(S) TO BETTER PROTECT BEDROOMS For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM BUILDING DEPT RERRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIO* 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003761 Date 12/18/03 ---------------------------------------------------------------------------- Special Notes and Comments VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited --------------------------- Due ------------------------------ Permit Fee Total 670.00 670.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1420.00 1420.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US ADDRESfS�/LO ATION: `—rLj- I I C d LOT 2 v BLOCK I SUBDIVISION f9 BUSINESS/OWNER NAME: ( ' ), I Cl- CONTRACTOR/HOMEOWNER: ( I I C CONTRACTOR ADDRESS - ELECTRICIAN: Q��I C V� PLUMBER: i Fa Office Use Only DATE: - I APPLICATI # - TEMP POLE # 4 C' F SEC/PH I Z PHONE: / /?"10S7 PHONE: ? 2 7 %OS / HVAC: L(/ViL2 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: tgId%k E FAA,7 ., STRUCTURE USE: StlJ4 h P ���� Iti HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: 3405 HEATED AREA: 256 y (Cost of Labor and Materials) ` / PUBLIC SEWER / �q, " NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: 3 INTERIOR WALL TYPE: S Ef WATER TAP: SIZE 34y EXTERIOR WALL TYPE: R(�� SIZE OTHER TAP: FOUNDATION TYPE: / o��W B fl 64 10 SIZE TEMP POLE ROOF TYPE: /DgUW2 GARAGE TYPE: SINGLE F_� DOUBLE a TRIPLE a ATTACHED DETACHED F__] CARPORT SIGNATURE OF APPLICANT: &Aq4, Official Use Only ��-1 jj o ents: YE or NO Plans Examiner Zoning Official • • Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating Pc IDIPoE . r r ce r O I h � CD✓�RE-f� - � r 1 3 '7D J� +cam j �Dln/(3uQGN Npci o-r CAS -r4 C �o' 1"- 2a' 01_I