Loading...
HomeMy WebLinkAboutRES2003-03754 3816 OLDENBURG LN BUILDING PERMIT1 of Uolle a ,3uauivii 1101 TEXAS AVENUE - COLLEGE-STABI-ON- k 7-7840- - - - - - - - - - C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning Owner. . . . . . . . . Contractor . . . . . . Application number Description of Work . Construction type . . . Occupancy type . . . . Flood Zone . . . . . . 7/23/04 244030-0409-0280 3816 OLDENBURG LN COLLEGE STATION TX 77845 EDELWEISS GARTENS PH 4 EDELWEISS GARTENS #4, BLOCK 9, LOT 28 UNKNOWN CATHEY/ELLIS DUPLEXES LTD B A CATHEY LTD 979 255-7064 03-00003754 000 000 RESIDENTIAL, 2 UNITS NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Approved . . . . . . . L..atlet. S�w►�, Building fficial VOID UNLESS SIGNED BY BUILDING OFFICIAL WE PREPARED 7/21/04, 7:26:34 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/21/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3816 OLDENBURG LN SUBDIV: EDELWEISS GARTENS PH 4 TENANT, NBR: 3816/3818 OLDENBURG CONTRACTOR : B A CATHEY LTD PHONE : (979) 255-7064 OWNER : CATHEY/ELLIS DUPLEXES LTD PHONE : PARCEL : 244030-0409-0280 APPL NUMBER: 03-00003754 RESIDENTIAL, 2 UNITS NEW ------------------------------------------------------------------------------------------------ PERMIET: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/31/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 12/31/03 DP 12/30/2003 03:29 PM GCARRILLO LATE AFTERNOON ON 12/31/03 Not Ready For Inspection B100 02 1/02/04 DS BLDG, FOUNDATION -SLAB TIME: 17:00 1/02/04 AP 12/31/2003 04:35 PM GCARRILLO Strings On Setbacks O.K. Slab Ground Installed B115 01 5/05/04 OC BLDG, FRAMING TIME: 17:00 5/05/04 AP 05/05/2004 08:06 AM SSTANLEY B125 01 7/21/04 BI BLDG, FINAL TIME: 17:00 07/20/2004 02:52 PM SSTANLEY (1 ----------------------------------- CONTINUED ONTO NEXT PAGE-----a------- CITY OR COLLEGE SW�XTIG44 REQ/JOB: WwvWE)RK REQUEST WF-05-089-03- / 0-01 - - PROJECT: PAGE - -- - - 4 20t04- PRINT DATE: CREW: PRINT TIME: 9:38:45 SCHEDULE LOCATION: 3816 OLDENBURG LN START:DATES 4/20/04 77845 COMPLETION: 4720704 GEN. LOC: COLLEGE STATION LOC ID: 197218 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: B A CATHEY ORIGIN: CUSTOMER -WALK IN US ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE l��'TEXAS-_ANTE --� — — - COLLEGE STATION, TX 77840 PHONE: (979)764-3570 - FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003754 Date 12/17/03 Property Address . . . . . . 3816 OLDENBURG LN Property ID . . 244030-0409-0280 R # . . . . . . • • • . . . . R114758 Tenant nbr, name . . . . . . 3616/3818 OLDENBURG Application description . . . RESIDENTIAL, 2 UNITS NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 177078 Owner Contractor CATHEY/ELLIS DUPLEXES LTD B A CATHEY LTb % STEELE, STEVEN BLAKE CATHEY 3000 BRIARCREST DR STE 602 P 0 BOX 9517 BR.YAN TX 778023056 COLLEGE STATION TX 77842 (979) 255-7064 ------ Structure Information DUPLEX ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type r RESIDENTIAL-SFR/DUPL_EX Other struct info EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA - - ----- — -- CONCRETE -- - ---- - - - --- - - --- - - - HEATED AREA 2 6 8 3 .0-0 - -INTERIOR WALL TYPE GYPSUM NUMBER OF BATHROOMS 6.00 NUMBER OF BEDROOMS 6.00 SEWER TYPE PUBLIC SERIAL ZONES 244.00 ---------------------------------------------------------------------------- Permit . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 694.00 Plan Check Fee .00 Issue Date . . . . 12/17/03 Valuation . . . . 177078 Expiration Date . . 6/15/04 Qty Unit Charge Per Extension BASE FEE 460.00 78.00 3.0000 THOU BLDG, VAL 100001-500000 234.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OFMECHANICAL EQUIPMENT --------BUILDING DEPT �2EPRESENTA�IVE: c�j� -' ---------------------------- -i APPLICANT: --CITY-OF-COLLEGE-STATION -- - - - ! 1 D 1 TEXAS--AVE- — -- - - - - -T- - COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003754 Page 2 Date 12/17/03 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF -OCCUPANCY. — -_-_ _-.- POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED --- -PRESSURE--REDUCING-TADVFr--SHALL---3E-PRO-V-IDED.-- THAT --LIMITS- THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND. EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK lot requires a 25' landscape buffer on rear of lot -V landscape plan needs a total of 400 points and must have a * lawn irrigation system installed BUILDING DEPT REPRESENTATIVE: APPLICANT: BUTT - 1-MG PERMIT - - CITY --OF COLLEGE -STATION -11-T1 — COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003754 Date 12/17/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 800.00 Fee summary Charged ---------- Paid ---------- Credited Due -------------------- ----------------- Permit Fee Total 694.00 694.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 1150.00 1150.00 .00 .00 Grand Total 1844.00 1844.00 .00 .00 --------: ------------------------------ BUILDING DEPT R,�PRESENTATIV� APPLICANT: CITY OF COLLEGE STATION -Iiol' TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3,496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003755 Date 12/17/03 Property Address . . . . . 3816 OLDENBURG LN Property ID . . . . . . . . . 244030-0409-0280 Tenant nbr, name . . . . TEMP POLE Application description . . . TEMP POLE Subdivision Name . . . . . . EDELWEISS GARTENS PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . UNKNOWN Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ CATHEY/ELLIS DUPLEXES LTD B A CATHEY LTD % STEELE, STEVEN BLAKE CATHEY 3000'BRTARCREST DR STE 602 P O BOX 9517 BRYAN TX 778023056 COLLEGE STATION TX 77842 (979) 255-7064 ----------------------------------------------------------------------------- Permit . . . `TEMP POLE PERMIT Additional�desc SS - -Permit Fee--- . -- Issue Date . . . . 12/17/03 Valuation . 0 - - - - Fees . . - - . - � . - - . - - TEMPP ELECT POLE CONNECT 45.00 Fee summary- ---------------- Permit Fee Total Other Fee Total Grand Total Charged - Paid - Credited---- 20.00 20.00 .00 45.00 45.00 .00 65.00 65.00 .00 - Due- .00 .00 .00 - 04 ----_-_-BUILDING DEPT�REPRESENTATIVE:--`•-.'^�---------------------------- APPLICANT: City of Colle e St ion MRK QUEST • PAGE 1 REQ/JOB: WF0480737 / 001 PROJECT: REQUEST DATE: 12/17/03 PRINT DATE: 12/17/03 CREW: PRINT TIME: 14:44:06 SCHEDULE LOCATION: 3816 OLDENBURG LN START:DATES 12/17/03 77845 COMPLETION: 12/17/03 GEN. LOC: COLLEGE STATION LOC ID: 197218 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: B A CATHEY LTD ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 2 - 3/4" WATER 4" SEWER 2 - 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------ ------------------------------------------ roro�.th.aw - - � DATE: ' 13 APPLICATION FOR BUILDING PERMIT - s CITY OF COLLEGE STATION APPLICATION r 1101 TEXAS AVENUE TEMP POLE x _ COLLEGE STATION, TX 77840 (979) 704.3570 (97%•764.9496 FAX W W W.CLCOLLEOE• ITATION.TX.US ADDRESS/LOCATION:gggp.IZ3811 LOT 7-2 BLOCK — q SUBDIVISION r—EAEL A JE G��*��-5►-- BUSINESS/OWNER NAME: I ~AID . - U-N, PHONE: Z -- ' CK° CONTRACTp ,j!9MEOWNER: 4 ,yq,r�� PHONE: CONTRACTOR ADDRESS: Z ELECTRICIAN: Rs • •-� _ drain VrA PLUMBER: PluabmAL HVAC• ��1- GOOD CENTS ftsidenlfal Only): G r '0 0 CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) M '( ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX-(U1?1ndsc8pe Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: - STRUCTURE�UOE: HOMEOWNER ASSOCIATIONIARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ �V VALUATION: $ TOTAL AREA: � ,.t HEATED AREA: 2l95 (Cost of LaW andM�alterials) r] PUBLIC SEWER —! / ,6-7 e) NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM, SEWER TAP: 4 L, ® WATER TAP: S¢E 0 OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE a ATTACHED SIGNATURE OF APPLICANT: NUMBER OF BATHROOMS: U � C INTERIOR WALL TYPE: �a?Y_PS�A EXTERIOR WALL TYPE: mK.t FOUNDATION TYPE: 0,ikw c x _r✓-TG_ ROOF TYPE: DOUBLE TRIPLE DETACHED CARPORT Q Offldaf use only is: o3 Plans Examiner _ OA. �• C.A. S paves -• Lc►r� InS Zoning Official YE o NO 244 6,30 0 1 0 0 �b 0 m r HEATED AREA: 2,683 sq. ft. SLAB AREA: 2,745 sq. ft. CATHEY LOT: 28 BLOCK: 9 SUBDIVISION: EDELWEISS GARTENS, PH IV HOMES DRESS: SCALE: V = 20' C lq-w Ps w p //4,j * C�0o0o� �000bj I I I I La►.,r�SGa�� ��a� 5 �-- �— 1Oeo, T' �eed HEATED AREA: 2,683 sq. 8. SLAB AREA: 2,745 sq. ft. CATHEY jamim HOMES SUBDMSION: EDELWEISS GARTENS, PH N ADDRESS: SCALE: V = 20' 500'L� 4b 1 014S Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating 13 L' 1�3� ✓ Building Permit Check -sheet • Permit Application • 1 set of drawings • 1 site plan drawings • 1 detail sheet • 1 spec's package • 1 MECcheck report CELING 40= MAX ST_ At4 rA JOIST 1- mMrSpM PAI 1M MAX .SPRY\ - -HEADER SCHEDULE W AYM SIICRUIe 49 PR ER LORD Gore WAR Oft N2SL WX wm 2x60trC.Q IS-r 2xI20it04 W-71 2x09,rCA 14r-r 2-2x4ONEDGE s-r 2xSOw= 17'-r 2x12OIrOA 1r10' 2x•OWOA 11-tr 2-2xSONEDGE e-r 2 x 119 • tr CA 2r-r 2 x 12 O 2s O.C: lr-.r 2 x 4 0 W 0& 1r-r 2-2 x 2 ON EDGE r-r Do NOT tommb am SOL oo Mr oam WIN OSL 20 P7r UK L L-VW WAD UX 2-2 x 10 ON EDGE r-r &M YmoRIXi NOTED OA FLAN. WU CFMW^ TRIPLID • ALL COWNRS AM TRPLl EDe R w RAFTERS 10 SE 2 x a TROVE[ 2-2 x 4 SiROAO SArR 0 MDSPAN OF a VWACS IMS Sat ►LATE AND DONE TOP PLA71 d O.A tY-? TFTN 2 X 4 OCLLAAR M • 7. FAWA E 1 X 4 O40M 1ifN SNo SRAOND • COMRS or DOEISOR 7t u&cot 1/r PLYWOOD STEEL AN LINTEL TABLE MIN. BEARING 4 CLEAR r-r OR r-r OR Y-r OR r-r OR r-r OR M-O' OR SPANS Los LESS LEST LESS LESS LESS sm 3 x z a- x 3l x t' XXs/ir Vr x D/Lr j /Y x s/1r 3 t � 1/Y x 5/1r 3 1/Y x 3/r 3 1/2' x 3/r 3��r-: Alr.�X. yr . r 2 x 4 RAF7ERS 47 lr O.C. OAAX W"PORTED LENNR - tY--r) 6420 NAL.S � 7/1r Os OECNW 160 FELT PAPA 2 NLE X 4 OOLTOP PLATE 2 x 44�-RF SSLLAO61X1— iamm SNOB SOLNEt Owm- 3/P FOL SACK girATSN RACE NSCN 2 X 4 S7LWOW Q6 TREATED =4 SOL VAMP M= • 3r =LtRRGr am "VAM Tr s110LE NAARW SOCE Lw rr(�/(�_' 2X10 TrAN ■���lt, —2 X S i' d ESTAM 4 PAIL DETAIL cc.Y.S. W. M' AlIti R� CoLAW 0 l�C: K" 7YrICAL GNP iiGRi !L'X"ti i0N r SOALL Ir. ril SORE+, Er.w LEAoao EW W 7fto MNTX'ALLY TO NMIORAL 1. CUT PURUN BRACE BIRD MOUTH TO FIT PURLIN ANGLE 2. PURUN TO BE O RIGHT ANGLE TO RAFTER 3. DO NOT PRE —BUILD 'r BRACE, INSTALL 2 X 4 BRACE FIRST, THEN JAMB 2 X 4 AGAINST RAtrTER k NAIL TO KNEE BRACE 2-16d RAFTER/ —7/1r OSS owan 15T FELT PARR • 2 X 4 DOUVU TOP FLAW —2 X 4 -p LLDOO.O 1 x S HAFAWLAW r 31V FOL SAOT SfEAVeNS MASONTE SENS 2 X4 SEAS S 1r n¢ X 4 SOTVCM PLATE %S 2 X 4-p3 2 X 6—#3 PURUN 2-16d i 6d O 2 X 4 KNEE BRACE TO RAISED BEAM ESESS4 24' O.C. 2X4/3 5 rUMN IL WMA �i R &W . r.r 1. CUT PURUN BRACE BIRD MOUTH TO FIT PURLW ANGLE 2. PURUN TO BE O RIGHT ANGLE TO RAPIER 3. DO NOT PRE —BUILD -r BRACE, ., w INSTALL 2 X 4 BRACE FIRST, THEN JAMB 2 X 4 AGAINST RAFTER & NAIL TO KNEE BRACE 2-16d 2 X 4— 2 X 6—#3 PURUN 2-18d 2 X 4 KNEE BRACE TO RAISED BEAM ESSSS4 O 24 24 O.C. 2X4� W 8 FUMN OVAL W aaRLR, 2n.r-r U �- T7-tc /,c AY -,-o 77tC- onF) / 142 (NcT io s�Acci 0 0 Description of Materials U.S. Department Of Housing HUD's OMB Approval No. 2502-0192 (exp. 04/30/2004) and Urban Development and 2502-0313 (exp. 8/3112001) Department of Veterans Affairs Farmers Home Administrtation Public reporting burden for this collection of information is estimated to average 30 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. This agency may not collect this information, and you are not required to complete this form, unless it displays a currently valid OMB control number. The National Housing Act (12 USC 1703) authorizes insuring financial institutions against default losses on single family mortgages. HUD must evaluate the acceptability and value of properties to be insured. The information collected here will be used to determine if proposed construction meets regulatory requirements and if the property is suitable for mortgage insurance. Response to this information collection is mandatory. No assurance of confidentiality is provided. I x1 Proposed Construction Under Construction No LJ Property address (Include City and State) Name and address of Mortgagor or Sponsor McAfee Mortgage 311 Arguello Drive College Station, Texas Instructions 1. For additional information on how this form is to be submitted, number of copies, etc., see the instructions applicable to the HUD Application for Mortgage Insurance, VA Request for Determination of Reasonable Value, or FmHA Property Information and Appraisal Report, as the case may be. 2. Describe all materials and equipment to be used, whether or not shown on the drawings, by marking an X in each appropriate check -box and entering the information called for each space. If space is inadequate, enter 'See mist." and describe under item 27 or on an attached sheet. The use of paint containing more than the percentage of lead by weight permitted by law is prohibited. 1. Excavation Bearing soil, type Sand/Clay 2. Foundations (To be inserted by HUD, VA or FrnHA) Name and address of Contractor or Builder B.A. Cathey, LTD P.O. Box 9517 College Station, Texas 77842 3. Work not specifically described or shown will not be considered unless required, then the minimum acceptable will be assumed. Work exceeding minimum requirements cannot be considered unless specifically described. 4. Include no alternates, "or equal" phrases, or contradictory items. (Consid- eration of a request for acceptance of substitute materials or equipment is not thereby precluded.) 5. Include signatures required at the end of this form. 6. The construction shall be completed in compliance with the related drawings and specifications, as amended during processing. The specifications include this Description of Materials and the applicable Minimum Property Standards. Footings concrete mix 5 sack transit mix __— _— _—_ strength psi 3000psi _ —_ Reinforcing 3/8" rebar ta.. 12 inch O.C. Foundation wall material n/a — ___ Reinforcingn/a Interior foundation wall material n/a_--_----__-- Party foundation wall n!a— Columns material and sizes n!a Piers material and reinforcing n/a Girders material and sizes __n/a Sills material n/a - ---_.--------------- Basement entrance areaway /a Window areaways n/a Waterproofing 6 milpolyethelene_—__— ---- — Footing drains—------------------- - Termite protection Dursban TC -------------------------- Basementless space ground cover n/a —_ insulation n/a foundation vents n/a_____ Special foundations _ See foundation drawings_—__—_ —_ — Additional information none 3. Chimneys Material _n/a — Prefabricated (make and size) _n/a — — Flue lining material _n/aHeater flue size: n/aFireplace flue size n/a_ Vents (material and size) gas or oil heater n/a water heater n/a — Additional information none 4. Fireplaces Type solid fuel U gas-buming circulator (make and size) —__ Ash dump and clean-out-n/a --- Fireplace facing _n/a — lining _ n/a—__ — hearth n/a ----------- mantel _n/a----------- ----- Additional information none ref. HUD Handbook 4145.1 8 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 1 of 6 VA Form 26-1852 and form FmHA 424-2 5 6. 7 Exterior Walls Wood frame wood grade, and species 2x4 16" o_c. YP #2- --- -- Comer bracing Building paper or felt Felt — Sheathing Celotex or equal — thickness 1/2"-- width 4 x 8 — solid L__I spaced —__—_ O.C. LJ diagonal —___— Siding J10ne----_---_ grade _n/a--__—_ type n/a -- size n/a_--- exposure n/a______ fastening n/a---_ Shingles none ------_ grade n!a ---_ type jya __ size n/a_—_ exposure 1/a-- fastening n/a Stucco none thickness _�!/a_— Lath _n/a___----------______—_ weight _n/a _ — lb. Masonry veneer Brick --_-- Sills Brick----_--_ Lintels 3x3x1/4" steel--- Base flashing Masonry solid a faced 0stuccoed total wall thickness 9 inches-- facing thickness 3 inches_ facing material Brick Backup material none______ thickness n/a ---_ bonding n'a------___—_ Door sills Aluminum Window sills Wood --_ ------ — — — Lintels Steel _— Base flashing Galvanized Steel Interior surfaces dampproofing, n/a coats of n/a ---- -- furring n/a Additional information Exterior painting material Exterior Latex —__— _—___--- number of coats 2 _— Gable wall construction 51 same as main wallsEl other Floor Framing Joists wood, grade, and species n/a--__---___ other n/a ___----_ bridging n/a------- anchors n/a Concrete slab L basement floor LJ first floor D ground supported R self-supporting mix n/a------------- thickness 5 inches _; reinforcing 3L" rebar-L 12"s l,ee dwasl— insulation none -- membrane Fill under slab material _Seleot fill ----____—_--_ thickness 12' Additional information See foundation drawings Subflooring (Describe underflooring for special floors under Item 21 Material grade and species -Na ---- Laid ❑ first floor u second floor 0 attic 64.0 _— sq. ft. Additional information 8. Finish Flooring (Wood only. Describe other finish flooring under Item 21) size n/a diagonal U right angles type n/a Rooms Grade Species Thickness Width Bldg. Paper Finish _Local'an First floor _ none n/a n/a n/a Na Na n/a Second floor none n/a n/a Na n/a Na n/a Attic floor none sq. ft. n/a n/a n/a n/a n/a _.—_-- _ n/a—_-----_-----..-._-- -__-_ - Additional information 9. Partition Framing Studs wood, grade, and species 2x4 FJYP #2 — _ _ size and spacing 2x4 Stud walls at 16"o_C_— Other n/a _______ Additional information 10. Ceiling Framing Joists wood, grade, and species 2x6 #2 YP ---__ Other 2x8 #2 YIP ---_—__ Bridging 2x4 #2 YP Additional information 11. Roof Framing Rafters wood, grade, and species 2x6 #2 YP----- --___ Roof trusses (see detail) grade and species none _— Additional information 12. Roofing Sheathing wood, grade, and species 7116" OSB---_--,---_-_-------_—_—_ a solid ❑ spaced n/a-- O.C. Roofing ComDostion/Shingle --- grade Class A size 36 nchtype 3-tab fbefM-a s __-- Underlay 30 lb felt _---_ weight or thickness -a/a­ size n/a__-- fastening nailed______ Built-up roofing _n/anumber of plies n�__-- surfacing material n;a Flashing material Galvanized sheet metal—_-----______ _ gage or weight 27 ---__-___ gravel stops ❑ snow guards Additional information 25 year warranty ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 2 of 6 VA Form 26-1852 and form FmHA 424-2 0 • 13. Gutters and Downspouts Gutters material none ------------- gage or weight _"ya -- size n/a -- shape n/a Downspouts material none _---_____--__-- gage or weight _n/a --__ size n/a — shape n/a number -n/a Downspouts connected to 0Storm sewer1-1 sanitary ❑ ry- sewer d well Splash lash blocks material and size n/a ----------- Additional information Rain gutters not provided 14. Lath and Plaster Lath walls n ceilings material n/a --- —__ weight or thickness n/a Dry -wall a walls O ceilings material gypsum board --- Joint treatment tape and float 15. Decorating (Paint, wallpaper, etc.) Rooms Wall Finish Material and Application Kitchen — _ textured and p2 Bath-- _ same as above Other (all other room: same as above Additional information none 16. Interior Doors and Trim Plaster coats n/a finish n/a thickness _1/2 in finish _textered and paint Ceiling Finish Material and textured and paint (off-white with flat finish) same as above same as above Doors type _Pre hung--_-- ---------__—__---_._ material _masonite -----------__—__— thickness _1 3/8 inch _ Door trim type _Finger Joint __-- material _pine-------- Base type FJ---__-- material pine — — — — — size 3 inch Finish doors _Interior white latex paint semi gloss------- - _ trim interior white latex with semi qloss finish Other trim (item, type and location) Interior white latex with semi gloss finish ---- ----------------------------- Additional information none 17. Windows Windows type Single hung —__ make Alenco Or equal __-- material Aluminumsash thickness n/a Glass grade n/a 9 —_____— D sash weights 1:1 balances, type n/a---__-- — head flashing n/a- ........ Trim type Aluminum---- _— material _Aluminum Paint _ ---_ number coats Weatherstripping type Plastic —_---__--------- material _n/a __--------__-- Storm sash, number n/a ScreensU full l Al half type standard ------ ---- number all --_ screen cloth material synthetic Basement windows type none----.------- material n/a-- — - screens, number n/a _— _ Storm sash, number n/a _ Special windows none ----------------------- Additional information none 18. Entrances and Exterior Detail Main entrance door material Metal or Fiberglass___ width 36 in thickness 1.75 in Frame material Wood_-_ -- thickness 4.62`. Other entrance doors material Metal — ------ width _36 !n _ thickness 1.75 in Frame material Wood_— — thickness 4.625 Head flashing n/a — -----_-----__—_ Weatherstripping type n/a--------__ saddles nib --- Screen doors thickness n/a— number _p/g_--_ screen cloth material n/a _— Storm doors thickness n/a--__ number Na Combination storm and screen doors thickness n/a —_ number �/a — screen cloth material n/a --- ------------------- - - - --------- Shutters _, hinged fixed Railings n/a--_ __-------- -- Attic louvers (see drawings) Exterior millwork grade and species _none _ paint none _-- number coats none ----------------------- Additional information none 19. Cabinets and Interior Detail Kitchen cabinets, wall units material Q; y�p�L-----____------- — lineal feet of shelves n/a ___. shelf width n/a Base units material Oak v�negr ------ _ — counter top Plastic laminate--- _-- edging _PI stic laminate________ Back and end splash Plastic j/grye_Qr — Finish of cabinets Laouer ---------------- -_-_—_ number coats 2 ---- Medicine cabinets make _p/�_——__----_ -- model n/a Other cabinets and built-in furniture -------------- - ------------ Additional information none ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10184) Retain this record for three years Page 3 of 6 VA Form 26-1852 and form FmHA 424-2 0 • 20. Stairs Treads — Risers Strings Handrail Balusters Stair Material Thickness Material Thickness Material Size Material Size Material Size Basement — Na n/a —_ n/a a N Na n/a n/a n/a Na n/a Main Na Na n/a Na — n/a n/a n/a n/a n/a n/a Attic n/a n/a n/a n/a Na Na n/a n/a n!a n/a Disappearing make and model number standard lumber yard inventory foldig a .- nttic stair ------- -- --- — ---------- ----- Additional information none 21. Special Floors and Wainscot (Describe Carpet as listed in Certified Products Directorvt Location Material, Color, Border, Sizes, Gage, Etc. — — Threshold Material Wall Base Material Underfloor Material m o Kitchen - — ---- n/a n/a n/a o IL n/a n/a n/a Bath - Breakfast _ — --- Familv & BF1 Carpet with 6 lb rebond pad n/a - - n/a -- _—__ n/a p N_..- Location Material, Color, Border, Cap. Sizes, Gage, Etc. Height Weight Over Tub HeicjY in St ko .; (From Floor) 3 Bath none n/a Na n/a r%uutuunai imurmauon 22. Plumbing - Fixture_ Number Location Make _ MFR's Fixture Identification No. Size_ Color Sink _ 1 Kitchen _ Polar or equal No. 4-33 stainless 6 inch deep stainless Lavatory _ Bathrooms Delta orequal No. 2522 19 inch round Water closet 2 _ Bathrooms Crane orequal — No. 3-662 Standard _white white Bathtub - — -- -- --- Shower over - tub -- — Bathrooms 60 x 32 72 Stall shower none -- --- - ---------------- --- - -_. - x ---------- - white --- _- -- - Laundry trays Bathroom accessories El Recessed material n/a --- number n/a ❑ Attached material _n/a--.— number _n/a Additional information Builder to provide kitchen garbage disposa , dishwasher, and water supply for refridgerator icemaker. Builder will not supply curtain rods for showers. Curtain rod Door Shower pan material n/a (Show and describe individual system incomplete detail in separate Water supply L 1 public community System individual (private) system* drawings and specifications according to requirements.) Sewage disposal 51 public n community system n individual (private) system' House drain (inside) n cast iron n the El other n/a --- -- House sewer (outside) El cast iron Ln the n other n/a - Water piping n galvanized steel O copper tubing Ll other t>/a _-- _ Sill cocks, number - see dwg ------------ -- Domestic water heater type __--50yallon— make and model standard inventory supply heating capacity gph. 100° rise. Storage tank material —__ _ capacity 50 — _ gallons Gas service -] utility company U liq. pet. gas other none _------ -- [:] Gas piping cooking lJ house heating Footing drains connected to11 storm sewer Cl sanitary sewer E-1 dry well n Sump pump make and model capacity _n/a --- _ _— discharges into -nfa Additional information none ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 4 of 6 VA Form 26-1852 and form FmHA 424-2 0 0 23. Heating 1-1 Hot water Steam ❑ Vapor P One -pipe system L Two -pipe system U Radiators El Convectors LJ Baseboard radiation Make and model 0 Radiant panel ❑ floor LJ wall 0 ceiling Panel coil material _n/a __---_— Circulator Return pumpMake and model n/a —__-------_ —__ capacity _n�a __— gpm. Boiler make and model n/a — Output n/a __— Btuh. net rating _n/a -- Btuh. Additional information none Warm air [-] Gravity D:� Forced Type of system Central air - ---------------- Duct material supply Flex duct —__— return Duct board Insulation R_6 thickness 1.- inch Outside air intake Furnace: make and model Make and model to be determined _----_ Input TBD __-- Btuh, output _TBD Btuh. Additional information 10 SEER air conditioning -make and modal to be determined ❑ Space heater u floor furnace ❑ wall heaterinput n/aBtuh. output n/a _—____._ Btuh. number units n/a _ Make, model Additional information none Controls make and types Make and model to be determined Additional information none Fuel: U Coal ❑ oil U gas liq. pet. gas LJ electric: ❑ other St(g-------___— storage capacity -oLa-___--- Additional information none Firing equipment furnished separately nGas burner, conversion type Stoker hopper feed [] bin feed Oil burner ❑ pressure atomizing vaporizing n/a Make and model n/a Control n/a Additional information none Electric heating system type to be determined _ — _---_ Input TBD __ watts @ _TBD_— volts output TBD Btuh. Additional information none Ventilating equipment 1-1 attic fan, make and model _none ---- ____ capacity _n/a cfm. i�kitchen exhaust fan, make and model vent fan included with overhead p_ oktonmicr owave_—_ Other heating, ventilating, or cooling equipment roof ridge vents, scj t vents, ceiling fans_and bathroom exhaust fans___ Additional information none 24. Electric Wiring Service Cl overhead ❑ underground Panel D fuse box 0 circuit -breaker make not available — AMP's not avail No. circuits n/a Wiring LJ conduit ❑ armored cable 0 nonmetallic cable knob and tube ❑ other n/a Special outlets 0 range 0 water heater 0 other-QyQj1_i.ulditYlQQm_jQLc Qthes dae[____--_______ x] Doorbell LJ Chimes I xJ Push-button locations front door only Additional information none 25.Llghting Fixtures Total number of fixtures _Lee dwcs1_—_ Total allowance for fixtures, typical installation, $ n/a Nontypical installation _none Additional information none ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/64) Retain this record for three years Page 5 of 6 VA Form 26-1852 and form FmHA 424-2 0 0 26. Insulation Location Roof Ceiling Wall _ Thickness n/a Material, Type, and Method of Installation n/a Vapor Barrier n/a n/a n/a 10 inches R-30 blown _ _ 3.5 inches Floor Ext Walls none none n/a foil tape 1/2 inch R-2.6 48 Tuff-R celotex sheathing nailed and taped at all joints 27. Miscellaneous: (Describe any main dwelling materials, equipment, or construction items not shown elsewhere; or use to provide additional information where the space provided was inadequate. Always reference by item number to correspond to numbering used on this form.) Towel bar, towel ring, and toilet paper holder to be installed in each bathroom Hardware (make, material, and finish.) Saturn or equal - basic architectural grade with bright brass finish Special Equipment (State material or make, model and quantity. Include only equipment and appliances which are acceptable by local law, custom and applicable FHA standards. Do not include items which, by established custom, are supplied by occupant and removed when he vacates premises or chattles prohibited by law from becoming realty.) none Porches 7 feet deep Terraces none Garages none Walks and Driveways Driveway width _--___ base material thickness surfacing material _n/a—___—_— thickness n/a Front walk width 4 feet _ material concrete -- thickness thickness 4 inch Service walk width 4 feet - material concrete _ thickness 4 inch Steps material _none -- treads n/a ___ risers n/a — Cheek walls n/a __--- Other Onsite Improvements (Specify all exterior onsite improvements not described elsewhere, including items such as unusual grading, drainage structures, retaining walls, fence, railings, and accessory structures.) 6 foot high cedar backyard privacy fence Landscaping, Planting, and Finish Grading Topsoil 2 inch thick I -XI front yard ❑x side yards I �] rear yard to ---10 feet behind main building Lawns (seeded, sodded, or sprigged) L ^J front yard __ sod _-__ LJ side yards -- sod___— ❑x rear yard sod_ Planting O as specified and shown on drawings P as follows: ---Na_ Shade trees deciduous_ n/ _ caliper _— n/a — Evergreen trees n/a to _ n/a B & B _ nLa__ Low flowering trees deciduous _ n/a _ to _ n/a n/a Evergreen shrubs n/a to ---- n/a B & B n/a High -growing shrubs deciduous _--._n/a — to n/a —n/a —Vines, 2-year n/a _-n/a_- Medium -growing shrubs deciduous _—n/a — to _—n/a Other see approved drawings ­n/a-- Low -growing shrubs deciduous --_n/a to ___n/a Identification —This exhibit shall be identified by the signature of the builder, or sponsor, and/or the proposed mortgagor if the latter is known at the time of application. Date (mm/dd/yyyy)_ ______—_______ Signature Signature ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 6 of 6 VA Form 26-1852 and form FmHA 424-2 MECcheck Compliance Report 1995 MEC M ECch eck Software Version 3.4 Release la Data filename: C:\Program Files\Check\MECcheck\Duplex One Story.cck TITLE: Duplex Single Story CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 12/04/03 DATE OF PLANS: December 4, 2003 PROJECT INFORMATION: Edelweiss Gartens 3812/3814 Oldenburg, Lot 27, Block 9, Phase 4 3616/3818 Oldenburg, Lot 28, Block 9, Phase 4 3820/3822 Oldenburg, Lot 29, Block 9, Phase 4 3608/3610 Oldenburg, Lot 67, Block 1, Phase 3 COMPANY INFORMATION: Cathey Homes COMPLIANCE: Passes Maximum UA = 530 Your Home = 432 18.5% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E Door 1: Solid Heat Pump 1: Electric Central Air, 6.8 HSPF, 10 SEER Gross Glazing Permit Number Checked By/Date Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2683 30.0 0.0 94 2075 13.0 0.0 145 230 0.640 147 75 0.610 46 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in MECcheckVersion 3.4 Release la and to comply with the mandatory requirements listed in the MEC check Inspection Checklist. Builder/Designer G�4 Date T /i ZOO 3