Loading...
HomeMy WebLinkAboutRES2003-03730 1816 BROTHERS BLVD 10 BUILDING PERMITPREPARED 5/06/04, 12:05:53 INSPECTION TICKET PAGE 4 • .Oise City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/06/04 w---------------------------------------------------------------------------------------------- ADDRESS . : 1816 BROTHERS BLVD 10 SUBDIV: REGENCY SOUTH COMMON AREA CONTRACTOR WILLIAM R KAUTZ PHONE (979) 3680 JR KAUTZ, WILLIAM R PHONE L 538700-0001-0100 A NUMBER: 03-00003730 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/18/04 OC BLDG, FOUNDATION -SLAB TIME: 17:00 2/18/04 AP 02/17/2004 03:46 PM SSTANLEY Slab Ground Installed �. Strings On Setbacks O.K. a. 15 01 3/19/04 TB BLDG, FRAMING TIME: 17:00 -t 3/19/04 AP 03/18/2004 04:02 PM GCARRILLO Bf 0 f 3/23/Q4BI BLDG, INSULATION TIME: 17:00 3/22/04"AW1.;- GA 03/22/2004 12:54 PM MALFORD B125 01 5/06/04...-" 131- - BLDG, FINAL TIME: 17:00 05/06/2004 08:16 AM SSTANLEY �p- CONTINUED ONTO NEXT PAGE -------------- I --------------------------------- ------------------- �, e Mandi Alford,- Insulation request inspection result, 1816 Brothers #1 03-3736 140 Page From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 3/22/2004 3:25:58 PM Subject: Insulation request inspection result, 1816 Brothers #1 03-3730 Print for File ' Inspected insulation, 1816 Brothers #1 03-3730, Experienced Builders 3-22-04 Inspection result: Inspected OK for Good Cents Notes Seal all exterior "T" & corner beams. CC: Alford, Mandi City of'College Station • WORK REQUEST PAGE REQ/JOB: WF0481359 / 001 PROJECT: REQUEST DATE. /19/03 PRINT DATE: 2/19/03 CREW: PRINT TIME: 11:18:56 SCHEDULE DATES LOCATION: 1816 BROTHERS BLVD 10 77840 COMPLETION: 12/19/03 GEN. LOC: COLLEGE STATION LOC ID: 135102 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: WILLIAM R KAUTZ •1 Q�ZIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WQR*G TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE 0 City of Collem St ion WW 40QUEST REQ/JOB: WF0481293 / 001 CREW: PROJECT: REQUEST DAT 12/19/03 PRINT DATE: 12/19/03 PRINT TIME: 8:12:21 SCHEDULE DATES LOCATION: 1816 BROTHERS BLVD 10 77840 START: 12/19/03 GEN. LOC: COLLEGE STATION LOC ID: 135102 COMPLETION: 12/19/03 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: EXPERIENCED BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER TAPS 4" SEWER AND 3/4" WATER TAPS Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE J3UlLLllvv rn�i ii 1 WYTY OF COLLEGE STATION _­'-­1-"1 TEXAS AVE- -- . • COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------------ Application Number . . . . : 03-00003730 Date 12/17/03 roperty Address . . . . . . 1816 BROTHERS BLVD 10 roperty ID 538700-0001-0100 # R38882 4pplication description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . REGENCY SOUTH COMMON AREA Property Use . . . . . . . . Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 110000 Owner Contractor ------------------------ - ----------------------- KAUTZ, WILLIAM R WILLIAM R KAUTZ 3937 MULLINS LOOP E COLLEGE STATION TX 778453519 3937 MULLINS LOOP E COLLEGE STATION TX 77845 (979) 3680 - Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1694.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 166.00 ------------------------------------------------------------------------ Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 490.00 Plan Check Fee 00 Issue Date . . . . 12/17/03 Valuation . . . . 110000 Expiration Date . . 6/.15/04 Qty Unit Charge Per Extension BASE FEE 460.00 10.00 3.0000 THOU BLDG, VAL 100001-500000 30.00 ---------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ---------------------- -- - - ---------------------------- -- - BUILDING DEPT REPRESENTATIVE: APPLICANT: C,�j BUILDING PERMiT Sc ITY OF COLLEGE STATION 1101 TEXAS AVE • COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 L=lication Number 03-00003730 Page 2 Date 12/17/03 ------------------------------------------------------------------------ 4Gpecial Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN -- ----- --------- -------- --- BUILDING DEPT REPRESENTATIVE- -: �- APPLICANT: BUILDING rf:xinl l CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 3 Application Number ---_-_-.--03_00003730-------------Date--12/17/03 -------------------------- jSpecial Notes and Comments PRIVATE GARAGES --- --------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited --------- Due ----------------- Permit Fee Total ---------- 490.00 ---------- 490.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1240.00 1240.00 .00 .00 -------------------- --- --� - ------ - -------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: �� TEMPORARY POLE PEKMiT ` ITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ----------------------------- ------------------------------------------ Application Number . . . . . 03-00003731 Date 12/17/03 Property Address . . . . . . 1816 BROTHERS BLVD 10 Property ID . . . . . . . . . 538700-0001-0100 Application description . . . TEMP POLE Subdivision Name . . . . . . REGENCY SOUTH COMMON AREA Property Use . . . . . . . . Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ - ----------------------- KAUTZ, WILLIAM R WILLIAM R KAUTZ 3937 MULLINS LOOP E COLLEGE STATION TX 778453519 3937 MULLINS LOOP E COLLEGE STATION TX 77845 (979) 3680 -------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 12/17/03 Valuation . . . . 0 ------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited Due ----- ----------------- Permit Fee Total ---------- 20.00 ---------- 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 -1 ----------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: W -/1--------------------------- 4w • APPLICATION FOR BUILDING PE MIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE �( COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.0 (.COLLEGE-STATION.TX.0 S ADDRESS/LOCATION: LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME: CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: Fa o%� U" 0* DATE: /,;z— /Id-0 3 APPLICATION # TEMP POLE # 11k. Air ► cj rfM SEC/PH PHONE: (o g LA - $ a -1 to ti PHONE: '2 2 C-;' - Li 6 5 y r 9'1 l yS ELECTRICIAN: PLUMBER: . %4P6.% S HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:_ TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 7 TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: SIZE WATER TAP: % SIZE OTHER TAP: � SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED a NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: '1 a •� P1�.� t�Z FOUNDATION TYPE: Vie„. . ROOF TYPE: swwd'& .1 DOUBLE TRIPLE a DETACHED a CARPORT a SIGNATURE OF APPLICANT: 1, Official Use Only CN 1 1('103 CE^- Plans Examiner Zoning Official • VWP Energy Code Compliance Information % Glazing of exterior walls Insulation R Mue of exterior walls • s Insulation R value of ceiling 1 (flat areas) . ., r Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating VA 0 Table 1: Minimum Insulation Thickness for CkculWng Hot Water Pipes. Insulation Thidrness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Citculatina Mains and Runouts Temperature ( F) to 1" jhp to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 is 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping S ss�ypes Ranee ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) 1 REScheck-Web - Microsoft Intemet Explorer TM Code: Ott IECC �1O A Registered members can save and recall project information. Registration is simple and free. >> Sian in or register. >) Why should I register? Project Envelope1.1 Mechanical New f Check Compliance] '© Reports J Print (OE) Help Row: 1 Edit Duplicate * Move Up ♦ Move Down �( Delete Add: ®®®® ®® - Cavity Continuous Assembly Gross Area R-Value R-Value U-Factor Wall: Wood Frame, 1'6" o.c. 1512 ft2 0.0 13.0 ©' Door: solid q0 ft2 0.165 ®` Window: Metal Frame, 2 Pane wl Low-E 120 ft2 0.165 Ceiling: Flat or Scissor Truss 1694 ft2 0.0 30.0 :J 44.3 % Better Than Code Max UA: 377.0 Your UA: 210.0 -- F F [—I* Intemet t f, * I