HomeMy WebLinkAboutRES2003-03725 402 SAPPHIRE DR BUILDING PERMITREQ/ZOB:-
- W'D-4$443-0- PROJECT-:
- — - EaST--'
PRINT I A'M:
1702704
CREW:
PRINT TIME:
14:48:18
SCHEDULE
DATES
LOCATION:
402 SAPPHIRE DR
START:
1f02/04
77845 COMPLETION:
1702704
GEN. LOC:
COLLEGE STATION LOC
ID: 190338
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REUESTOR:
LAFOLLETE CONSTRUCTION
ORIGIN: CUSTOMER -WALK
IN
USER ID:
GCARRILLO AUTH: GCARRILLO
WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES, CSCS
Task code_ : :_ - SET UP -NEW -UTILITY -ACCT - SET -
F`acil-ity ID .
Assigned Department: OT-CUSTOMER SERVICE
EPAIRED'10/08/04, 7:59:20 INSPECTION TICKET PAGE 1
ty of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/08/04
----------------------------------------------------------------------------------------------
DRESS . : 402 SAPPHIRE DR SUBDIV: NONE FOREST PH 1
NTRACTOR :_.LAFOLLETTE CONSTRUCTION PHONE : (979) 690-7531
NEkc JOHNSON INVESTMENTS INC PHONE :
RCgL 585200-0105-0230
PL NUMBER: 03-00003725 RESIDENTIAL, 1 UNIT DETACHED NEW
-_-z-------------------------------------_-------_____-------------_-___-__-_--------_--__---
k4ITt BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
P/SQ ' COMPLETED RESULT RESULTS/COMMENTS
---1 -------------------------------------------------------------------------------------------
0001 1/09/04 TB BLDG, FOUNDATION -SLAB TIME: 17:00
1/09/04 AP 01/08/2004 09:27 AM SSTANLI$Y
AFTERNOON
Strings On Setbacks O.K.
Slab Ground Installed
15 01 2/10/04 TB BLDG, FRAMING TIME: 17:00
2/10/04 AP 02/09/2004 04:38 PM GCARRILLO
FIRE BLOCK RT. SIDE OF FIREPLACE
COMPLETE WALKWAY TO MECH UNIT} CONTINUOUSLY, HAS OPEN AREAS
W/O WALKWAY.
301,01 2/17/04 TB BLDG, INSULATION TIMES 17:00
2/17/04 DP 02/16/2004 02:38 PM 4STANLEY
DIDN'T COMPLETE WALKWAY TO ME UNIT.
INSULATION O.K., INCOMPLETE NOTES FROM PRIOR INSPECTIONS.
�0 02 2/18/04 TB BLDG, INSULATION TIME: 17:00
2/18/04 AP 02/17/2004 05:00 PM MALFORD
work done on walkway pet last inspection
25 II01 1 0 /04 BI BLDG, FINAL TIME: 17:00
oh(AWk 10/07/2004 12:44 PM SSTANLEY
---------------------------------
COMMENTS AND NOTES---------------------
-----------------
- ---- - --- ---• ~,ems �_ l ,___---------�-- �`�------ -----
CREW : . PRI DATE
LOCATION: 402 SAPPHIRE DR 77845 C0I�IPL�'TY'Sf31 : 1 ¢ 704
GEN. LOC: COLLEGE STATION LOC ID: 1-40338
REF Rt
""PT: DE -BUILDING IN5 ECTION PRIORITY: �.
RETOt: LA Oi,LTTE CCINfiTRUCTION ORIGIN: C�T4MER-WALK IN
US D : SS�L Y AUTH : SSTAX"Y WORK TYPE: R INE
4" SEWER 3 4" WATER
aastsaaeaxxsamass+w+earraasxxssecmasa,aasmaaeas�.: xeaxxxasnsa=aaxxge�ema=a-xmxxxsa=aaaaxxexawa::
4 " SEWER 3 j. 4 " WATER.,
Category code CS -CUSTOMER SERVICES CSCS
a$� 4;0 e : -M UP- NE-- Lrr-IL-ITY T E'I`- -- -- -- --
Ass gne pArtment: OT-CUSTOMER. SERVICE - -
x=sssasaaxsazaamcaxmmssss=asaessasaxmsasxaaa=asesaaftaasx�adara�aar:ssxx.:•:esxaaacasassaa=amxa
e
CITY TATI ON _
- - - -- - - -COLLEGE- STATION, —TX- 7-7840 - -
- PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00003725 Date 1/02/04
Property Address . . .
. . . 402 SAPPHIRE DR
Property ID
. . 585200-0105-0230
R # . . . . . .
. . . R108619
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . STONE FOREST PH 1
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . .
. . . SINGLE FAMILY RESIDENTIAL
Application valuation .
. . . 145794
Owner
Contractor
------------------------
JOHNSON INVESTMENTS INC
------------------------
LAFOLLETTE CONSTRUCTION
PO BOX 800
JASON LAFOLLETTE
COLEMAN TX
768340800 1723 BALL CIRCLE
COLLEGE STATION TX 77845
(979) 690-7531
------ Structure Information
SINGLE FAMILY -----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct_ info . .
. . EXTERIOR WALL TYPE __ - _ BRICK
IMPACT/PRORATA-FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER _ OF GARAGE RAYS - _ 2-. 0 0 -
- - _
HEATED AREA 2209.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 252.00
----------------------------------------------'------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . SS
Permit Fee . . . .
598.00 Plan Check Fee .00
Issue Date . . . .
1/02/04 Valuation, . . . . 145794
Expiration Date . .
6/30/04
Qty Unit Charge Per
Extension
BASE FEE 460.00
46.00 3.0000 THOU BLDG, VAL 100001-500000 138.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT
SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE
PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
--------BUILDING `--------------------------
DEPT REPRESENTATIVE:-���
APPLICANT:
BUILDING PERMtr—
CITY OF COLLEGE STATION
-- 11�1- TEXAS AVE - -
-- - - - COLLEGE--STAT-ION, TX 77840- - -- - -
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003725
Page 2
Date 1/02/04
Special Notes and Comments
NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR
CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT
CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS.
ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED
TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC
UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM
BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394.
ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE - - - -
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALLHAVE ALL-TOP_PLATE_AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
--------BUILDING DEPT REPRESENTATIVE:--C
•--------------------------
APPLICANT:
CITY OF COLLEGE STATION
'PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00003725 Date 1/02/04
----------------------------------------------------------------------------
Special Notes and Comments
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 1811 ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY-INSTL 400.00
Fee summary
-----------------
Permit Fee Total
Plan Check Total
_ _Other Fee Total_
Grand
Charged Paid
598.00 598.00
.00 .00
___ __ 750.00 750.00
1348.00 1348.00
Credited
Due
.00
.00
.00
.00
.00
.00 --
.00
.00
-
APPLICANT: !' C//
TRMPOW-W77-POLIg PERMIT
CITY OF COLLEGE STATION
-- COLLHC TATION - TX--77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . 03-00003726 Date 1/02/04
Property Address . . . . 402 SAPPHIRE DR
Property ID . . . . . . . . . 585200-0105-0230
Tenant nbr, name . . . . TEMP POLE
Application description . . . TEMP POLE
Subdivision Name . . . . . . STONE FOREST PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
JOHNSON INVESTMENTS INC LAFOLLETTE CONSTRUCTION
PO BOX 800 JASON LAFOLLETTE
COLEMAN TX 768340800 1723 BALL CIRCLE
COLLEGE STATION TX 77845
(979) 690-7531
-
---------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . SS
- -P-Parm t Fee---- _ 20-._00
Issue Date--: .-3_/02j04 - --- Valuation- 0
------------------------------------------------------- 7---------------------
Other Fees .—. . . TEMP ET ECT POT F CONNECT 45.0 _
-Fee summary- -
Charged
--Paid -
----------
--Credited -- ------Due - -
--------------------
-----------------
Permit Fee Total
----------
20.00
20.00
.00 .00
Other Fee Total
45.00
45.00
.00 .00,
Grand Total
65.00
65.00
.00 .00
---------------- ---- --------------- BUILDING DEPT REPRESENTATIVE. � � ---------------------_------
APPLICANT: G.-,,l/'�"^
• stir Fo'Ol U�0*
APPLICATION FOR BUILDING PERMIT DATE:
CITY OF COLLEGE STATION APPLICATION n
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE #�
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: n x
LOT 23 '/BLOCK _r SUBDIVISION �1C✓�_ �/�S'f- SEC/PH
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: Kk4&4 - 1kC. PHONE:
CONTRACTOR ADDRESS: 1723 Cr`,Q 1. S • % -7W qo
ELECTRICIAN: �"� I�Cp C-1[PLUMBER: s1✓
HVAC: r GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION. (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR,
VALUATION: $ m� TOTAL AREA: _
(Cost oflabor and Materials)
❑ PUBLIC SEWER 1 141tl1 � NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP:
WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE
HEATED AREA: Z2e7
Z
dr-yc,..rCC
&I a(c
S� a�
V
SINGLE [::] DOUBLE F9 TRIPLE a
ATTACHED DETACHED a CARPORT
$�E
3
SIZE
SIZE
SIGNATURE OF APPLICANT:
Plans Examiner
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
Official Use Only
ents:
YE9 or NO
Zoning Official
AM Smoke
•
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
3✓
.3-1f �
�0.60�
OW IZ'o
.DO
Zo' Ftm
L GT 24 L o '� 2 Izo S �k- L 0 7 ZZ
. � 4
D N E S'io KY M-N �K
n 2g43 *A&
5-5
yam. � t7 Z°I
he
711
K 4Z•D'IWE
5ArFHt1-E DKIYE
50' R.o w- t7' gg paV6r#4p '
-j-\,I kC �n S IC e- S4baaS
SITE PLAN
U T lb, %LK. 5
5Tow rwg&-Y wb.
C0LLE69 srATIoN,7X-
•
•
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.3 Release lb
Data filename: C:\Program Files\Check\MECcheck\Stoneforest.cck
TITLE: Stone Forest
2�- &ILC
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 12/ 12/03
DATE OF PLANS: 12-1-03
PROJECT INFORMATION:
Lot 23 Block 5
COMPANY INFORMATION:
LaFollette Construction, Inc.
COMPLIANC . Passes
Maximum UA = 771
Your Home = 666
13.6% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1:
Metal Frame with Thermal Break, Double Pane with Low-E
Door 1: Solid
Door 2: Glass
Floor 1: Unheated Slab -On -Grade, 0.0' insul.
Heat Pump 1: Air Source, 6.8 HSPF, 12 SEER
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
2209 30.0 0.0
77
1965 13.0 2.5
113
376
0.600 226
21
0.073 2
24
0.600 14
225 0.0
234
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been
designed to meet the 2000 IECC requirements in MECcheck Version 3.3 Release lb and to comply with the
mandatory requirements listed in the MECcheck Inspection Checklist.
Builder/Designer /��� Date �— —�