HomeMy WebLinkAboutRES2003-03678 1447 FINCASTLE LOOP BUILDING PERMITPAGE 1 `
City of College Station
GJORK 45QUEST
REQ/JOB:
WF0479940 / 001 PROJECT:
REQUEST DATE:
12/15/03
PRINT DATE:
12/15/03
CREW:
PRINT TIME:
13:48:26
SCHEDULE
DATES
LOCATION:
1447 FINCASTLE LOOP
START:
12/15/01---
77845
COMPLETION:
12/15/03—
GEN. LOC:
COLLEGE STATION LOC ID: 198902
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
ED FROEHLING ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MALFORD AUTH: MALFORD WORK TYPE:
ROUTINE
4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
AND 3/4" WATER TAPS
-
4" SEWER
AND 3/4" WATER TAPS
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department:
-------------------------------------------------------------------------------
OT-CUSTOMER SERVICE
PREPARED 7/20/04, 7:34:45 INSPECTION TICKET PAGE 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/20/04
------------------------------------------------------------------------------------------------
ADDRESS . : 1447 FINCASTLE LOOP SUBDIV: SHENANDOAH PH 9
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 569500-0933-0260
APPL NUMBER: 03-00003678 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 1/05/04 TB BLDG, FOUNDATION -SLAB TIME: 17:00
1/05/04 AP O1/05/2004 08:46 AM SSTANLEY
Slab Ground Installed
Strings On Setbacks O.K.
B115 01 2/24/04 DS BLDG, FRAMING TIME: 17:00
3/03/04 AP 02/23/2004 03:02 PM GCARRILLO
B130 01 3/11/04 DP BLDG, INSULATION TIME: 17:00
3/11/04 AP 03/11/2004 09:32 AM MALFORD
Did Not Fix Notes From Previous Inspections
B125 01 7/20 0 B BLDG, FINAL TIME: 17:00
76 li ,AD 07/19/2004 03:24 PM MALFORD
-------------------------------------- COMMENTS AND NOTES--------------------------------------
�L�
BUILDING PERMIT
CITY OF COLLEGE TAT F_--• _... _ _.._ �•
1101 TEXAS AVE 3Y "--
COLLEGE STATION, TX 77840 '-
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------------------------------------------------
Application Number . . . . . 03-00003678 Date 12/15/03
Property Address . . . . . . 1447 FINCASTLE LOOP
Property ID . . 569500-0933-0260
R# . . . . . . . . . . . . . R***** -+�-
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW -
Subdivision Name . . . . . . SHENANDOAH PH 9
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 125070
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) 7-
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK "
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1895.00 ....
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
---------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc MA
Permit Fee . . . . 538.00 Plan Check Fee .00
Issue Date . . . . 12/15/03 Valuation . . . . 125070
Expiration Date 6/13/04
Qty Unit Charge Per Extension.
BASE FEE 460.00
26.00 3.0000 THOU BLDG, VAL 100001-500000 78.00rt:
----------------------------------------------------------------------------..
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
---------------------��` - ---------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: --tip
BUILDING PERMIT
• CITY OF COLLEGE STATO •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
03-00003678
Page 2
Date 12/15/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
--------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
. • CITY OF COLLEGE STATI� • ►-
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00003678 Date 12/15/03
---------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged
Permit Fee Total 538.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1288.00
Paid Credited Due
------------------------------
538.00 .00 .00
.00 .00 .00
750.00 .00 .00
1288.00 .00 .00
---------------- - - - - -----------------------------.,,.,
BUILDING DEPT REPRESENTATIVE:
APPLICANT: — —
Fw OfrK WS Only
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
DATE:
APPLICATION #
TEMP POLE #
ADDRESS/LOCATION: I VA, ( t10C l4A1Cl
LOT 2l� y BLOCK b�) SUBDIVISION 6h On SEC/PHIq
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: f-p FI?AEA(,w4 vtc,DER IAI)c PHONE: 776 •$Z66
CONTRACTOR ADDRESS: 3987 1414a &gb
ELECTRICIAN: a r13 r5z0c- -2/ c--. PLUMBER: TR-rPLE "S ' Pl-uM8/A14
HVAC: 5G 1.vN0V.4T1VA5 S61zVle_A GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req )
DESCRIPTION OF WORK:
STRUCTURE USE: _51N4LO /-, 4/njj_ y R gS/D6iVc
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EABPRJ &/t'
VALUATION: $ , J- , (-1 I r . r- TOTAL AREA: YVI HEATED AREA: I S1 �
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
RI -SEWER TAP:
WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
%4
SIZE
SIZE
SINGLE a
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE Eft` TRIPLE a
DETACHED F-] CARPORT a
SIGNATURE OF APPLICANT: zG..,�
Official Use Only
ents:
�;� ► ��e YES NO
Plans Examiner Zoning Official
• •
1040
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
0 •
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1447FC.rck
TITLE: 1447 FINCASTLE LOOP
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 12/04/03
DATE OF PLANS: DECEMBER 5, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 408
Your Home UA = 351
14.0% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter
R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
1895
30.0
0.0
66
Wall 1: Wood Frame, 16" o.c.
399
13.0
0.0
23
Window 1: Metal Frame:Double Pane with Low-E
79
0.640
51
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.20
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
425
13.0
0.0
30
Window 2: Metal Frame:Double Pane with Low-E
36
0.640
23
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.81
Wall 3: Wood Frame, 16" o.c.
388
13.0
0.0
23
Window 3: Metal Frame:Double Pane with Low-E
110
0.640
70
• • 0 •
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Wall 4: Wood Frame, 16" o.c. 409 13.0 0.0 32
Window 4: Metal Frame:Double Pane with Low-E 13 0.640 8
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer Date 3
00
L,oT a L_Ol- 0 o
,bl-oLy . V)WLV-
L0T a Lp
3L-OC, L 33
N q5' 2 U, III' E, L0Z, 61
Fl NCh5-rL.V,- �� P
50' R a w ^- 2?' faVeTr\l,
Scnlc I''2o'
144-1 FL