HomeMy WebLinkAboutRES2003-03677 1408 ELKTON CT BUILDING PERMITege St -at'
- - - - - - COLLEGE STATION -TX 77840
CERTIFICATE OF OCCUPANCY
P E R M A N E N T
Issue Date . . . . . . 6/29/04
Parcel Number . . . . . 569500-0933-0190
Property Address . . . 1408 ELKTON CT
COLLEGE STATION TX 77845
Subdivision Name . . . SHENANDOAH PH 9
Legal Description . . . SHENANDOAH #9, BLOCK 33, LOT 1
9
Property Zoning . . . . UNKNOWN
Owner. . . . . . . . .
Contractor . . . . . . ED FROEHLING BUILDERS
979 776-8266
Application number 03-00003677 000 000
Description of Work . RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved . . . . . . .
Building Off cial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 6/28/04, 12:23:35 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/28/04
------------------------------------------------------------------------------------------------
ADDRESS . : 1408 ELKTON CT SUBDIV: SHENANDOAH PH 9
ONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
1ZER . . PHONE
CEL 569500-0933-0190
APPL NUMBER: 03-00003677 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 1/12/04 DS BLDG, FOUNDATION -SLAB TIME: 17:00
1/12/04 AP O1/12/2004 09:28 AM MALFORD
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 2/23/04 DP BLDG, FRAMING TIME: 17:00
2/23/04 AP 02/23/2004 10:06 AM MALFORD
B130 01 3/02/04 TB BLDG, INSULATION TIME: 17:00
3/02/04 AP 03/01/2004 12:24 PM SSTANLEY
B125 01 6a8 �4, B� � � BLDG, FINAL TIME: 17:00
'P �� jis�../�► 06/28/2004 12:09 PM GCARRILLO
-------------------------------------- COMMENTS AND NOTES--------------------------------------
City of College St ion
WORK -QUEST h - PAGE' 1
REQ/JOB; WF0479936 / 001 PROJECT: REQUEST DATE:
12/15/PRINT 03 „
CREW: PRINT TIME: 13:47:10
SCHEDULE DATES
LOCATION: 1408 ELKTON CT 03
77845 COMPLETION: 12/15/03'
GEN. LOC: COLLEGE STATION LOC ID: 198888
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE
4" SEWER AND 3/4" WATER TAPS
-------------------------------------------------------------------------------
4" SEWER AND 3/4" WATER TAPS
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE -
___________________________
it*BUILDING PERMIT-•
CITY• 4F -EOL zGF_.. STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
Property Address . . .
Property ID . . . . . .
R# . . . . . . . . . .
Application description
Subdivision Name . . .
Property Use . . . . .
Property Zoning . . . .
Application valuation .
. . . 03-00003677 Date 12/15/03
. . . 1408 ELKTON CT
. . . 569500-0933-0190
R*****
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
. . . SHENANDOAH PH 9
. . . RESIDENTIAL
. . . SINGLE FAMILY RESIDENTIAL
. . . 125070
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845 --
(979) 776-8266
------ Structure Information
SINGLE FAMILY ------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1895.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------.
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
MA
Permit Fee . . . .
538.00 Plan Check Fee .00
Issue Date . . . .
12/15/03 Valuation . . . . 125070
Expiration Date
6/13/04
Qty Unit Charge
Per Extension-=*.
BASE FEE 460.00
26.00 3.0000
THOU BLDG, VAL 100001-500000 78.00-
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
---------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003677
Page 2
Date 12/15/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT -�-
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED _.._
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct -
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
---------------------ol
---------------------------
BUILDING DEPT REPRESENTATIVE: .--
APPLICANT:
•BUILDING PERMIT
CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00003677 Date 12/15/03
----------------------------------------------------------------------------
Special Notes and Comments
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
Charged Paid
538.00 538.00
.00 .00
750.00 750.00
1288.00 1288.00
Credited Due
.00
.00
.00
.00
.00
.00
.00
.00
-----------------------(�-�kAI-74 --------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
•
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
Fa Ofte Use Only
DATE: / 10
APPLICATION #
TEMP POLE
ADDRESS/LOCATION:
(�} V
G�
I«L�Y�^ LAA
)y-T
LOT
I
k BLOCK r
SUBDIVISION I�ck-
oaCh
SEC/PHA_
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: Fp &ep6aLw4 Soj(,pe-rz 1A26 PHONE: %%6'8U6
CONTRACTOR ADDRESS: 39S7 /414N Lo.uESD/rE ftab
ELECTRICIAN: _(� r(3 64&6,- R_tc-- PLUMBER: TiLrNGE ` .5 ' P1_0M81A14
HVAC: ?-G 1.�No V.4Tl Vf SE/LV/G.E GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE: _6/,v4c.6 0,4M/j_y ReS1p&vc
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ &,/A
VALUATION: $ (,7r- CC, V / TOTAL AREA: jq Lq HEATED AREA: f,�j`6
(Cost of Labor and Materials)
Ell'P-UBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP: EXTERIOR WALL TYPE: b 1 C -YC
OTHER TAP: FOUNDATION TYPE: G)` a, ul ywi e
❑ TEMP POLE ROOF TYPE:
GARAGE TYPE:
SIGNATURE OF APPLICANT: "ter _- x�'
Official Use Only
ments;
ESorNO
Plans Examiner Zoning Official
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
SIZE
SIZE
SIZE
SINGLE a
ATTACHED
INTERIOR WALL TYPE:
.0L
DOUBLE TRIPLE a
DETACHED � CARPORT a
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
n,6
o
•
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1408EK.rck
TITLE: 1408 ELKTON COURT
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 12/04/03
DATE OF PLANS: DECEMBER 5, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 408
Your Home UA = 356
12.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter
R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
1895
30.0
0.0
66
Wall 1: Wood Frame, 16" o.c.
399
13.0
0.0
24
Window 1: Metal Frame:Double Pane with Low-E
73
0.640
47
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Front
Projection factor: 0.20
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
409
13.0
0.0
31
Window 2: Metal Frame:Double Pane with Low-E
14
0.640
9
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Projection factor: 0.81
Wall 3: Wood Frame, 16" o.c.
388
13.0
0.0
22
Window 3: Metal Frame:Double Pane with Low-E
120
0.640
77
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Wall 4: Wood Frame, 16" o.c. 425 13.0 0.0 32
Window 4: Metal Frame:Double Pane with Low-E 36 0.640 23
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec/ and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer Date 4/
'
�.
I
LOT 2
&Ux-"k .�
E. L--V..TotA Gov 9-7 4-�
5c1 R•o, w, 2' PAvur
JOOscalc, 14• Zo'
i
I �oT 25
l Lcx, 3 3
)4n6 EK