HomeMy WebLinkAboutRES2003-03676 1453 FINCASTLE LOOP BUILDING PERMITPREPARED 6/11/04, 12:03:17
INSPECTION TICKET PAGE 3
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 6/11/04
------------------------------------------------------------------------------------------------
ADDRESS
. : 1453 FINCASTLE LOOP SUBDIV: SHENANDOAH PH 9
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
,OWNER
PHONE
iPARCEL
569500-0933-0290
APPL NUMBER: 03-00003676 RESIDENTIAL, 1 UNIT DETACHED NEW
l
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
1/05/04 TB
BLDG, FOUNDATION -SLAB TIME: 17:00
1/05/04 AP
O1/05/2004 08:08 AM SSTANLEY
Slab Ground Installed
Strings On Setbacks O.K.
B115
2/09/04 DS
BLDG, FRAMING TIME: 17:00
f1
j
2/09/04 AP
02/06/2004 01:37 PM SSTANLEY
9130 01
2/10/04 DS
BLDG, INSULATION TIME: 17:00
2/10/04 DP
02/10/2004 11:56 AM GCARRILLO
need to fix from notes on previous inspections
12512
6/11/04 BI
BLDG, FINAL TIME: 17:00
06/11/2004 10:14 AM SSTANLEY
B125 01
6/11/04 BI
BLDG, FINAL TIME: 17:00
6/11/04 CA
06/11/2004 10:03 AM SSTANLEY
-------------------------------------- COMMENTS AND NOTES ----------------
'4
bwj
City of Collegge S ion
F1ORK06UEST
REQ/JOB: WF0479943 / 001 PROJECT:
CREW:
PAGE 1 __
PRINT DATE: 12/15/ INT03
PRINT TIME: 13:49:57
SCHEDULE DATES
LOCATION: 1453 FINCASTLE LOOP START: 12/15/03
77845 COMPLETION: 12/15/03
GEN. LOC: COLLEGE STATION LOC ID: 198908
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH : MALFORD WORK TYPE: ROUTINE
4" SEWER AND 3/4" WATER TAPS -»-
4" SEWER AND 3/4" WATER TAPS �I
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
.+Y�Yrrr
BUILDING PERMIT
Via : f ` 8gT hbN
1101 :� .
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------------------------------------------------
Application Number . .
Property Address . . .
Property ID . . . . . .
R# . . . . . . . . . .
Application description
Subdivision Name . . .
Property Use . . . . .
Property Zoning . . . .
Application valuation .
. . . 03-00003676 Date 12/15/03
. . . 1453 FINCASTLE LOOP
. . . 569500-0933-0290
. . . R*****
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
SHENANDOAH PH 9
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
. . . 125070
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
R
------ Structure Information SINGLE FAMILY
-----
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1895.00 -
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
-----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
MA
Permit Fee . . . .
538.00 Plan Check Fee
.00
Issue Date . . . .
12/15/03 Valuation . .
. . 125070..
Expiration Date
6/13/04
_
Qty Unit Charge Per Extension...
BASE FEE 460.00"�
26.00 3.0000 THOU BLDG, VAL 100001-500000 78.00-
----------------------------------------------------------------------------..
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
--------------------- -- AW --------------------------"�.."
_
BUILDING DEPT REPRESENTATIVE:
APPLICANT: ��
BUILDING PERMIT
• CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00003676 Date 12/15/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE --
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR "
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL .,
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
--------------------------------------- 0�w -- ----------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION • -+.-
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------.
Page 3
Application Number . . . . . 03-00003676 Date 12/15/03
-----------------------------------------------------------------------------+�-
Special Notes and Comments
PRIVATE GARAGES
---------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged
Permit Fee Total 538.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1288.00
Paid Credited Due
------------------------------
538.00 .00 .00
.00 .00 .00
750.00 .00 .00
1288.00 .00 .00
--------------------------------------r
- - -----------------------------
BUILDING DEPT REPRESENTATIVE: �-
APPLICANT: .��
\J
Fo OO�ft. Use 0*
APPLICATION FOR BUILDING PERMIT DATE: I O`_IA -
CITY OF COLLEGE STATION APPLICATION #
IZ3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE #
(979) 764-3570 (979) 764-3496 FAX
WWW.Cl.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: 14,5
LOT vBLOCK J SUBDIVISION :-?` )E- �Lin4 �0C Y) SEC/PH
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: f-p f"elluA6 E vjLt DE/t , IA.26 PHONE: 7i6 -8U05
CONTRACTOR ADDRESS: 3997 14144 ge*p
ELECTRICIAN: 6 r-R J5L,06-r&(c_ PLUMBER: _T/Lil'40r "S; ' PLUMBIA14
HVAC: T'G 1.v.yOVA-rI VAS 6&ZW -E GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEUREN OVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE: 51k4c6 j9,4/n/j_ y R_6_<1D4.v4
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PFjOJECT REGISTRATION#EABPRJ 111A C'�
VALUATION: $ 12.5, 0% 0. (DO� IO d TOTAL AREA: ab1 HEATED AREA: JC60'J
(Cost of Labor and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
EI�SEWER TAP: -i
SIZE
WATER TAP: �4 1
SIZE
❑ OTHER TAP:
SIZE
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE: -" I (� y
/) CY) C-f V C% c'
❑ TEMP POLE ROOF TYPE: wrnO -9,1 c'1
GARAGE TYPE: SINGLE a DOUBLE Efl-` TRIPLE J
ATTACHED = DETACHED F__] CARPORT
SIGNATURE OF APPLICANT:�.r.r
Official Use Only
=YErNO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) •30
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor 6
R value of ductwork 2.6 '
A/C SEER rating J U St-C-R
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1453FC.rck
TITLE: 1453 FINCASTLE LOOP
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 12/04/03
DATE OF PLANS: DECEMBER 5, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 406
Your Home UA = 356
12.3% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter
R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
1895
30.0
0.0
66
Wall 1: Wood Frame, 16" o.c.
399
13.0
0.0
22
Window 1: Metal Frame:Double Pane with Low-E
90
0.640
58
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.20
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
409
13.0
0.0
31
Window 2: Metal Frame:Double Pane with Low-E
14
0.640
9
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.81
Wall 3: Wood Frame, 16" o.c.
388
13.0
0.0
23
Window 3: Metal Frame:Double Pane with Low-E
104
0.640
67
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Wall 4: Wood Frame, 16" o.c. 425 13.0 0.0 32
Window 4: Metal Frame:Double Pane with Low-E 36 0.640 23
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer Date
I
aocK_ 33
I� 28
�jLoL� 33
LOT �g
'6 -oLk 33
2-01
f
1
_ &-oG� 3�
5-
OT 7,6
I .
,Z
� 1
L 2-9
i
h0' fZ a w. -- 27' ?av 2rnCrci"