HomeMy WebLinkAboutRES2003-03635 2003 RAVENSTONE LOOP BUILDING PERMITSPENCER J. BUCHANAN ASSOCIATES, INC. Consulting Engineers Bryan, Texas 206 North Sims, 77803/P.O. Box 672, 77806/(979) 822-3767 IN -PLACE DENSITY TEST RESULTS CLIENT: KELLY BURT DOZER PROJECT: Castlegate Subdivision, 2003 Ravenstone LOCATION: House Pad SJB PROJECT NO.: 040142 DATE TEST LOCATION See attached location plan) MOISTURE CONTENT (�/, DRY DENSITY (pc� PERCENT COMPACTION MATERIAL TYPE 10:30 AM 01/05/04 Test No. 1, 1 st lift 15.3 106.6 92.7 A 01/05/04 Test No. 2, 1 st lift 17.3 107.1 93.1 A 01/05/04 Test No. 3, 1st lift 15.2 112.4 97.7 A 01/05/04 Test No. 2A, 1st lift, RECHECK 17.1 109.4 95.1 A 01/05/04 Test No. 1A, 1st lift, RECHECK 14.0 114.4 99.5 A 1:30 PM 01/05/04 Test No. 4, 2nd lift 15.2 111.8 97.2 A 01/05/04 Test No. 5, 2nd lift 15.2 115.6 100.0+ A 01/05/04 Test No. 6, 2nd lift 15.7 114.7 99.7 A 4:00 PM 01/05/04 Test No. 7, 3rd lift 15.2 110.8 96.3 A 01/05/04 Test No. 8, 3rd lift 15.0 111.8 97.2 A 01/05/04 Test No. 9, 3rd lift 15.5 111.9 97.3 A OPTIMUM COMPACTION MOISTURE MAXIMUM EFFORT CONTENT DRY DENSITY MATERIAL TYPE ASTM D 698 12.5% 115.0 pcf (A) Reddish tan clayey sand ( 030232) L� v KELLY BURT DOZER 2003 Ravenstone In -Place Density Test Location Plan /JG NOTE: Test locations shown are approximate 6' SJB Project No. 040142 0 Test Number (sketch not to scale) January 5, 2004 i 0 SPENCER J. BUCHANAN ASSOCIATES, INC. Consulting Engineers Bryan, Texas 206 North Sims, 77803/P.O. Box 672, 77806/(979) 822-3767 IN -PLACE DENSITY TEST RESULTS CLIENT: KELLY BURT DOZER SJB PROJECT NO.: 040142 PROJECT: Castlegate Subdivision, 2003 Ravenstone LOCATION: House Pad DATE TEST LOCATION See Location Plan MOISTURE CONTENT (% DRY DENSITY cf PERCENT COMPACTION MATERIAL TYPE 10:00 AM 01/06/04 Test No. 10, 4th lift 16.9 111.3 96.8 A 01/06/04 Test No. 11, 4th lift 15.8 111.7 97.1 A 01/06/04 Test No. 12, 4th lift 15.6 113.2 98.4 A 1:00 PM 01/06/04 Test No. 13, 5th lift 15.3 113.5 98.7 A 01/06/04 Test No. 14, 5th lift 16.2 112.8 98.1 A 01/06/04 Test No. 15, 5th lift 14.9 114.6 99.7 A 4:00 PM 01/06/04 Test No. 16, 6th lift 16.8 110.4 96.0 A 01/06/04 Test No. 17, 6th lift 14.3 110.0 95.7 A 01/06/04 Test No. 18, 6th lift 15.8 111.9 97.3 A OPTIMUM COMPACTION MOISTURE MAXIMUM EFFORT CONTENT DRY DENSITY MATERIAL TYPE ASTM D 698 12.5% 115.0 pcf (A) Reddish tan clayey sand (030282) NOTE: 6" depth tested TEST[ N/ENGINEER l KELLY BURT DOZER 2003 Ravenstone In -Place Density Test Location Plan NOTE: Test locations shown are approximate SJB Project No. 040142 0 Test Number (sketch not to scale) January 6, 2004 PREPARED 6/07/04, 11:58:17 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/07/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 2003 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-1102-0500 APPL NUMBER: 03-00003635 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 1/22/04 TB BLDG, FOUNDATION -SLAB TIME: 17:00 1/22/04 AP 01/22/2004 08:00 AM MALFORD late this afternoon Strings On Setbacks O.K. Slab Ground Installed B115 01 3/09/04 DP BLDG, FRAMING TIME: 17:00 3/09/04 AP 03/09/2004 08:25 AM MALFORD B130 01 3/11/04 DP BLDG, INSULATION TIME: 17:00 3/11/04 AP 03/11/2004 09:38 AM GCARRILLO B125 01 B BLDG, FINAL TIME: 17:00 06 _I0/04 �� 06/07/2004 09:46 AM MALFORD --------------------- ------------ COMMENTS AND NOTES -------------------- i CITY OF COLLEGE STATION WORK REQUEST PAGE 1 REQ/JOB: WF0515248 / 001• PROJECT: REQUEST DATE: 5/06/04 PRINT DATE: 5/06/04 CREW: PRINT TIME: 15:57:10 SCHEDULE DATES LOCATION: 2003 RAVENSTONE LOOP 04 77845 COMPLETION: 5/06/04 GEN. LOC: COLLEGE STATION LOC ID: 191088 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE SWR 4" ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- SWR 4" Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION WORK REQUESt PAGE' 1 REQ/JOB: WF0482413 / 001 PROJECT: REQUEST DATE: 12/23/PRINT 03 CREW: PRINT TIME: 15:01:27 SCHEDULE DATES LOCATION: 2003 RAVENSTONE LOOP 03 77845 COMPLETION: 12/23/03 GEN. LOC: COLLEGE STATION LOC ID: 191088 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE City of Collegge Station FTORK&QUEST• • PAGE, 11 REQ/JOB: WF0479153 / 001 PROJECT: REQUEST DATE: 12/11/03 E PRINT DATE: 12/11/03 CREW: PRINT TIME: 8:20:13 SCHEDULE DATES LOCATION: 2003 RAVENSTONE LOOP START: 12/11/03 77845 COMPLETION: 12/11/03 GEN. LOC: COLLEGE STATION LOC ID: 191088 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE O 1! Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\2419-2539 2003 Ravenstone.cck TITLE: Plan # 2419-2539 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 12/05/03 DATE OF PLANS: 12-05-2003 PROJECT INFORMATION: Francis 2003 Ravenstone College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 909 Your Home UA = 690 24.1% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2539 30.0 0.0 89 Ceiling 2: Cathedral Ceiling (no attic) 267 19.0 0.0 14 Wall 1: Wood Frame, 16" o.c. 2587 13.0 0.0 185 Window 1: Metal Frame, Double Pane with Low-E 269 0.670 180 SHGC: 0.40 Door 1: Solid 38 0.500 19 Door 2: Glass 18 0.440 8 SHGC: 0.40 Floor 1: Slab -On -Grade: Unheated 187 0.0 195 Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations, submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date r REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 12/05/03 TITLE: Plan # 2419-2539 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.500 Comments: [ ] 2. Door 2: Glass, U-factor: 0.440 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Add to Library Window Name Assembly Type Quantity Width x Height - - Unit Area Total Area U-Factor SHGC Comments/ Description 1 3060 Twin Metal Frame, Do 1 6'-0" 6'-0" 36.00 36.00 ft2 0.670 2 6010 Metal Frame, Do 1 6'-0" 1'-0" 6.00 6.00 ft2 0.670 3 0860 Metal Frame, Do 1 0'-8" 6'-0" 4.00 4.00 ft2 0.670 4 1 14010 Metal Frame, Do 1 4'-0" 1'-0" 4.00 4.00 ft2 0.670 5 1060 Metal Frame, Do 2 1'-0" 6'-0" 6.00 12.00 ft2 0.670 6 4060 Metal Frame, Do 2 4'-0" 6'-0" 24.00 48.00 ft2 0.670 7 40 RT Metal Frame, Do 1 4'-0" 2'-0" 8.00 8.00 ft2 0.670 8 4008 Metal Frame, Do 1 4'-0" 0'-8" 2.67 2.67 ft2 0.670 9 2850 Metal Frame, Do 2 2'-8" 5'-0" 13.33 26.66 ft2 0.670 10 1 12060 Metal Frame, Do 2 2'-0" 6'-0" 12.00 24.00 ft2 0.670 11 1 13060 Metal Frame, Do 2 3'-0- 6'-0" 18.00 36.00 ft2 0.670 12 2860 Metal Frame, Do 2 2'-8" 6'-0" 16.00 32.00 ft2 0.670 13 3050 Metal Frame, Do 2 3'-0" 5'-0" 15.00 30.00 ft2 0.670 14 15 16 17 18 19 20 21 22 23 24 25 Window Area Total: 269.33 12/05/03 11:18:28 1 /1 Area Calculator: Assembly Type Comments/ Description Opaque door solid Door Area Total: 55.56 12/05/03 11:18:29 1 /1 Area Calculator: Assembly Type �llll©��M Gross Area Comments/Description Ceiling Area Total: 2539.00 12/05/03 11:18:29 1 /1 Area Calculator: 0 Assembly Type MMMMComments/Description- © ... . . �M�M 1:: 11 Exterior Wall Area Total: 2587.33 12/05/03 11:18:30 1 /1 Area Calculator: Assembly Type Comments/Description M11MIMPROM..■�■ Floor Area Total: 0.00 12/05/03 11:18:30 1 /1 BUILDING PERMIT CITY OF COLLEGE STATION • - 1161 "TEXAS' ' �AVE"._ COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003635 Date 12/10/03 Property Address . . . . . . 2003 RAVENSTONE LOOP Property ID . . . . . . . . . 184200-1102-0500 R # . . . . . . . . . . . . . R10 9219 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 167574 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD STYLECRAFT BUILDERS 4490 CASTLEGATE DR RANDY FRENCH COLLEGE STATION TX 778453388 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2539.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 664.00 Plan Check Fee .00 Issue Date . . . . 12/10/03 Valuation . . . . 167574 Expiration Date . . 6/08/04 Qty Unit Charge Per Extension BASE FEE 460.00 68.00 3.0000 THOU BLDG, VAL 100001-500000 204.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT - --------------------------------------------------- - --------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT:--- �� i BUILDING PERMIT is CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00003635 Date 12/10/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN BUILDING DEPT REPRESENTATIVE: ----------- 7-Z - ------------------- APPLICANT: li- / — BUILDING PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003635 Date 12/10/03 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Permit Fee Total 664.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1414.00 Paid Credited Due ------------------------------ 664.00 .00 .00 .00 .00 .00 750.00 .00 .00 1414.00 .00 .00 BUILDING DEPT REPRESENTATIVE: ;�� APPLICANT: TEMPORARY POLE PERMIT . CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID R4 . . . . . . . . . . . Tenant nbr, name . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00003636 2003 RAVENSTONE LOOP 184200-1102-0500 R109219 TEMP POLE TEMP POLE CASTLEGATE SEC 1 PH 1 RESIDENTIAL PLANNED DEVL HOUSING 0 Date 12/10/03 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ STYLECRAFT BUILDERS 4490 CASTLEGATE DR RANDY FRENCH COLLEGE STATION TX 778453388 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 12/10/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: ��tiZ 0 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX. US ADDRESS/LOCATION: LOT _LLBLOCK �y 9w Fa offs U� only DATE: � V 'C' 3 . APPLICATION #C) J _ CQ ' J ✓lk�� �, TEMP POLE # CJ� 1ASE ` BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): I No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framin STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDA D (TAS) eROJECT REGISTRATION# EABPRJ N/A VALUATION: $_11 L �7 % TOTAL AREA:_`-�''2<� HEATED AREA:,-''_ (Cost of Labor and Materials) �X PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �X SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE QX WATER TAP: %" EXTERIOR WALL TYPE: Siding and/or Masonry SIZE ❑ OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE ❑X TEMP POLE ROOF TYPE: Composition GARAGE TYPE: SINGLE DOUBLE [X] TRIPLE ATTACHED X DETACHED � CARPORT % ' `11 n V - SIGNATURE OF APPLICANT: For St lecraft Official Use Only �YOrents: ES%r NO Plans Examiner Zoning Official E Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating R13 R30 R19 .40 / .65 R6 / 12