Loading...
HomeMy WebLinkAboutRES2003-03627 3604 OLDENBURG CT BUILDING PERMITPREPARED 5/13/04, 7:50:08 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/13/04 ------------------------------------------------------------------------------------------------ DRESS . : 3604 OLDENBURG CT SUBDIV: EDELWEISS GARTENS PH 3 ONTRACTOR B A CATHEY LTD PHONE (979) 255-7064 ER CATHEY/ELLIS DUPLEXES LTD PHONE PARCEL 244030-0301-0660 APPL NUMBER: 03-00003627 RESIDENTIAL, 2 UNITS NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/18/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 12/18/03 AP 12/17/2003 03:32 PM SSTANLEY 10 IF POSSIBLE IN THE MORNING 12/18/03 Slab Ground Installed Strings On Setbacks O.K. B115 011 1/06/04 DS BLDG, FRAMING TIME: 17:00 1/07/04 AP w 01/06/2004 08:17 AM GCARRILLO B130 01 1/07/04 DS. BLDG, INSULATION TIME: 17:00 i 1/07/04 AP 01/07/2004 10:17 AM SSTANLEY 3 lAte afternoon B126 014 5/1[/04 Bt BLDG, FINAL TIME: 17:00 Dulk 05/12/2004 02:48 PM SSTANLEY I i late aftexwon f 1 --------------------------------- COMMENTS AND NOT ---------------:-------------------- O 1 CITY OF COLLEGE STATION WORK REQUEST REQ/JOB: WF0481482 / 001 PROJECT: CREW: LOCATION: 3604 OLDENBURG CT 77845 i PAGE * 1 REQUEST DATE: 12/19/03 PRINT DATE: 12/19/03 PRINT TIME: 15:50:03 SCHEDULE DATES START: 12/19/03 COMPLETION: 12/19/03 GEN. LOC: COLLEGE STATION LOC ID: 197126 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: B A CATHEY ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code Task code: Facility ID Assigned Department: CS -CUSTOMER SERVICES CSCS SET UP NEW UTILITY ACCT SET OT-CUSTOMER SERVICE CITY OF COLLEGE STATION REQUEST PAGE REQ/JOB: WF0485380 / 001 PROJECT: REQUEST DATE: 1/06/04 PRINT DATE: 1/06/04 CREW: PRINT TIME: 16:18:48 SCHEDULE DATES . LOCATION: 3604 OLDENBURG CT 77845 COMPLETION: 1/06/04 GEN. LOC: COLLEGE STATION LOC ID: 197126 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: B A CATHEY `' ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MAL;VORD WORK TYPE: ROUTINE 3/4" water tap --------------------------------=---------------------------------------------- ------------------------------------------------------------------------------- REQUEST COMMENTS Only paid for one at time building permit was - issued should have been 2 this is a duplex r ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ 3/4" water tap Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ury (06/1 cv.,J�4' �G4 PREPARED 12/19/03, 13:04:21 INSPECTION TICKET PAGE 11 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/19/03 ------------------------------------------------------------------------------------------------ •DDRESS . : 3604 OLDENBURG CT SUBDIV: EDELWEISS GARTENS PH 3 CONTRACTOR B A CATHEY LTD PHONE (979) 255-7064 OWNER CATHEY/ELLIS DUPLEXES LTD PHONE PIRCEL 244030-0301-0660 APPL NUMBER: 03-00003628 TEMP POLE ------------------------------------------------------------------------------------------------ PERMIT: TEMP 00 TEMP POLE PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ TEMP 01 12/19 03 BI TEMP, FINAL TIME: 17:00 q Gi N Ae 12/19/2003 08:26 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES -------------------------------------- • Mandi Alford - Re: 3604 Oldenburg and 3608 Oldenburg 'Tage 1 From: Jennifer Reeves To: Mandi Alford Date: 5/14/2004 10:57:04 AM Subject: Re: 3604 Oldenburg and 3608 Oldenburg Mandi - Sven has stamped the landscape plan approved and it has been approved out in the field as well. Thanks, Reeves Jennifer Reeves Staff Planner City of College Station jreeves@cstx.gov (979) 764-3570 (979) 764-3496 FAX >>> Mandi Alford 5/14/2004 8:56:50 AM >>> Calling for CO on both duplexes B A Cathey Landscaping is there per David Pullin CC: Bridgette George; Sven Griffin 70' . a f C7 01 (s 0 I I I I I I I 1 30' I I 20' PEE 1 25' SETBACK I ---- I — --------------------- I I I I I I I I I I I * I 1 I I YI QI I I I I I I� II mlUJ Ia? ~I I I m U) ICO II In �I I I� I I I I I 4'::SI EWALK I �, X Xk X X O X }C JC K !C 1 I I I 25' SETBACK' 1 PAR.K;, G t• 1. ;• , 00 Do o0ovcp 7 0' .1 5' oo' W O HEATED AREA: 2,683 sq. 4L SLAB AREA: 2.745 sq. & CATB EY HOMES LOT: 27 9 SUBDIVISION: EDELWEISS GARTENS, PH IV ADDRESS:fm(c,04Ql &c ALE: I" - 20. L ING PEWT COLLEG'E-•�CWAT 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Nuker . . . . . 03-00003627 Date 12/15/03 Property Address . . . . . . 3604 OLDENBURG CT Property ID 244030-0301-0660 R # . . . . . . . R114698 Application description . . . RESIDENTIAL, 1 UNIT ATTACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . DUPLEX RESIDENTIAL Application valuation . . . . 177078 Owner Contractor ------------------------ CATHEY/ELLIS DUPLEXES ------------------------ LTD B A CATHEY LTD % STEELE, STEVEN BLAKE CATHEY .,. 3000 BRIARCREST DR STE 602 P QT;BOX 9517 BRYAN TX 778023056 'COLLEGE STATION TX 77842 ~ (9 ) 255-7064 -------------------------- Structure, Inform, 40a ------------------------- Construction Type . . . . . COM$USTIBLE-JUUNPROTECTED) Occupancy Type . . . . . . **NEEDS TO BE ENTERED** Other struct info . . . . . EXTERIOR WALL -TYPE BRICK IMPACT/PRORATA'FEES PAID NA FOUNDATION'..TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2683.00 INTERIOR WAL TYPE GYPSUM NUMBER OF BATHROOMS 6.00 NUMBER OF BEDROOMS 6'.00 _.. SEWER TYPE PUBLIC SERIAL ZONES 247.00 -----------------------------------= Permit . . . . . . ---------------------------------------- BUILDING PERMIT Additional desc . . GC Permit Fee . . . . 694.00 Plan Check Fee .00 Issue Date . . . . 12/15/03 Valuation . . . . 177078 Expiration Date 6/13/04 Qty Unit Charge Per rxtension• BASE FEE 460.00. 78.00 3.0000 THOU BLDG, VAL 100001-500000 234.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT -------------------------------------- 11-A-4A----------------------------- BUILDING DEPT , REPRESENTATZI�E : L .A JI_VI APPLICANT: td&L�" BUILDING PERMIT ITY OF COLLEGE STATIO# 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003627 Date 12/15/03 - ------------------------------------------------------------------------------ Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT, AND/OR-jCCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE _ MAXIMUM STATIC WATER PRESSURE TO 80 P---- For residential applications with a glaz g area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. _... WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ------------------------------------------------------------- BUILDING DEPT�EPRESENTA-T-I-V-E-:- APPLICANT: /l W BUILDING PERMIT TY OF COLLEGE STATIOI� 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number 03-00003627 Date 12/15/03 ---------------------------------------------------------------------------- Special Notes and Comments TM: need lawn irrigation system installed --- need 400 points on landscape plan ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 800.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 694.00 694.00 .00 .00 �-- Plan Check Total .00 .00 .00 .00 Other Fee Total 1150.00 1150.00 .00 .00 Grand Total 1844.00 1844.00 .00 .00 BUILDING DEPT REPRESENTATIVE - APPLICANT: EMPORARY POLE PERMIT �ITY OF COLLEGE STATIOMW 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------------------------------------------------,W—. Application Number . . . . . 03-00003628 Date 12/15/03 Property Address . . . . . . 3r,-604 OLDENBURG CT Property ID . . , . . . . . . 244030-0301-0660 Application description . . . TEMP POLE Subdivision Name . . . . . EDELWEISS'GARTENS PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . DUPLEX RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ s ------------------------ CATHEY/ELLIS DUPLEXES LTD B A CATHEY LTD STEELE, STEVEN BLAKE CATHEY - 3000 BRIARCREST DR STE 602 P O BOX 9517 =_ BRYAN TX 778023056 COLLEGE STATION TX 77842 (9�7) 255-7064 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------------------------- Permit . . . . . . TEMP POLE PEERMIT Additional desc GC f,a; Permit Fee . . . . 20.00 -� Issue Date . . . . 12/15/03 "laluation . . . . 0 _..._ ------------------------------------------------- ----------------------------- ' Other Fees TEMP ELET; 'p,OLE CONNECT 45.00 t Fee summary Charged Paid•Qf .Credited Due ----------------- ---------- ------ - �-------------------- Permit Fee Total 20.00 2G."OF .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00% 65.00 .00 .00 ---------------------------------------CAA --------------------------- BUILDING DEPTEPRESENTA l� !: APPLICANT: I APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US Fa Ofte Use avy DATE: Of APPLICATION # O TEMP POLE a� JLVFJ ADDRESS/LOCATION: L ILM 13666 LOT iob BLOCK SUBDIVISION BUSINESS/OWNER NAME: PHONE:D(o `U CONTRACTOR/HOMEOWNER: PHONE: '_5 — %y b ((11, O r- / V 0000NTRACTOR ADDRESS. _11? 4 Z ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS (Residential only): C CLASS OF WORK �ACCESSORY/STORAGE LOCATION , RE -ROOF (Total/Partial) CI ADDITION MOVIdG "'' -=t, ' SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTR,UCT{QWt" , SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVA N, SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIaIV C}f MITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATI6N# EABPRJ VALUATION: $-- — TOTAL AREA: HEATED AREA: (Cost of Labor PUBLIC SEWER 8 NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM- 'NUMBER OF BATHROOMS: SEWER TAP: INTERIOR WALL TYPE: SIZE WATER TAP: EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE F-] TRIPLE a ATTACHED a DETACHED F-] CARPORT a SIGNATURE OF APPLICANT: o Official Use Only , ` ents: YES, rNO Plans Examiner Zoning Official 0 ST Energy Code Compliance. Information . . f�# % Glazing of exterior walls Insulation R value of exterior walls A-1 In4atign R value of ceiling I (flat areas) a' In ulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ducty avrvl`:� A/C SEER rating, ,ry , Description of Materials U.S. Department of Housing and Urban Development Department of Veterans Affairs Farmers Home Adfninistitation HUD's OMB Approval No. 2502-0192 (exp. 04/30/2004) and 2502-0313 (exp. 8/31/2001) Public reporting burden for this collection of information is estimated to average 30 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. This agency may not collect this information, and you are not required to complete this form, unless it displays a currently valid OMB control number. The National Housing Act (12 USC 1703) authorizes insuring financial institutions against default losses on single family mortgages. HUD must evaluate the acceptability and value of properties to be insured. The information collected here will be used to determine if proposed construction meets regulatory requirements and if the property is suitable for mortgage insurance. Response to this information collection is mandatory. No assurance of confidentiality is provided. x ;; Proposed Construction Lj Under Construction No. Property address (Include City and State) Name and address of Mortgagor or Sponsor McAfee Mortgage 311 Arguello Drive College Station, Texas Instructions 1. For additional information on how this form is to be submitted, number of copies, etc., see the instructions applicable to the HUD Application for Mortgage Insurance, VA Request for Determination of Reasonable Value, or FmHA Property Information and Appraisal Report, as the case may be. 2. Describe all materials and equipment to be used, whether or not shown on the drawings, by marking an X in each appropriate check -box and entering the information called for each space. If space is inadequate, enter "See misc." and describe under item 27 or on an attached sheet. The use of paint containing more than the percentage of lead by weight permitted by law is prohibited. 1. Excavation Bearing soil, type Sand/Clay_—__—__—__—__ (To be inserted by HUD. VA or FmHA) Name and address of Contractor or Builder B.A. Cathey, LTD P.O. Box 9517 College Station, Texas 77842 3. Work not sQWicetiy described or shown will not be considered unless required, thJ"_-ents inimum acceptable will be assumed. Work exceeding minimum re cannot be considered unless specifically described. 4. Include no s, 'or equal' phrases, or contradictory items. (Consid- eration of a for acceptance of substitute materials or equipment is not thereby5. Include signequired at the end of this form. 6. The censtrup be completed in compliance with the related drawings and specification{j a's•amended during processing. The specifications include this Descriptio06f Aerials and the applicable Minimum Property Standards. . .. . .11 -------- --------------------------------- Foundations Footings concrete mix 5 sack transit mix — _ —_ strength psi 3000psi _ -- Reinforcing 3/8=rebar (312 inch O.C. Foundation wall material n/a —--__—__— — ---- Reinforcing n/a __— --_ --- Interior foundation wall material n/a _—__— —_ — --_—_ Party foundation wall ---------------------- Columns material and sizes n/a Piers material and reinforcing _n_/a Girders material and sizes -------__-______-__ Sills material n/a ----------------------- Basement entrance areaway n/a Window areawaysn/a -------------------------- Waterproofing 6 milpolyethelene _--------- Footing drains n/a_ ---------------------------- Termite protection Dursban TC -------------------------- Basementless space ground cover n/a insulation n/a foundation vents n/a_____—_ Special foundations _ See foundation drawings_—_ Additional information none 3. Chimneys Material _n/a _ Prefabricated (make and size) _n/a Flue lining material ._n/a------------ _—__—_— Heater flue size n/a ------------------- Vents (material and size) gas or oil heater n/a _ water heater Additional information none 4. Fireplaces Type solid fuel gas -burning U circulator (make and size) Fireplace facing _n/a _ — — — lining _n/ahearth n/a Additional information none Fireplace flue size n/a__________ - Ash dump and clean-out-n/a ___ - mantel _n/a ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 1 of 6 VA Form 26-1852 and form FmHA 424-2 5. 6. 7 Exterior Walls Wood frame wood grade, and species 2x4 16" o_c_YP #2---- 0 Comer bracing Building paper or felt Felt -- Sheathing Celotex or equal _ thickness 1/2" width 4 x 8 Elsolid ❑ spaced _--_ o.c. u diagonal ----- Siding -none—.---------- grade _n/a_—___ type n/a —_ size Na __ exposure ��a fastening n/a---_ Shingles none,------__— grade _n/a --_ type Na _ size Na —_ exposure /a fastening n/a -- Stucco _ none _--_— thickness _n/a-- Lath _n/a--`—_ — — — — — — — — - weight _n/a---____ lb. Masonry veneer Brick --_-- Sills Brick----_--_ Lintels 3x3x1/4" steel--- Base flashing Brick Masonry 1-1solidu faced stuccoed total wall thickness 9 inches-- facing thickness 3 inches_ _ facing material Brick - Backup material none ---___thickness n/a ---_ bonding ft/a Door sills Aluminum _ — — — — Window sills Wood -- -- Lintels steel -- Base flashing Galvanized Steel Interior surfaces dampproofing, n/a-- coats of n/a ----_ furring n/a Additional information Exterior painting material Exterior Latex —__ ---_ number of coats 2 _— Gable wall construction a same as main walls other construction_-----__----_—_--_ Floor Framing Joists wood, grade, and species Na--__----_ other rVa -----_ bri a n/a _—�---- anchors n/a Concrete slab L1 basement floor first floor ground supported self-s ng mix n/a thickness 5 inches reinforcing 318" rebar­0 12"s,c.-(aee dwgsl— insulation ngne —_ � �____ membrane Fill under slab material select fill ----__— --_ thickness 12__ 'lam Additional information's='' See foundation drawings �.r. . Subflooring (Describe underflooring for special floors under Item 21 Material grade and species _n/a -- ___ Laid first floor 1-1 second floor a attic 64.0 _— sq. ft. Additional information 8. Finish Flooring (Wood only. Describe other finish flooring under Item 21) diagonal 77 __ size _n/a --- type n/a-------- ..'right angles Location _ Rooms _ _ Grade Species Thickness Width Bldg. Paper Finish First floor none _—_ n/a n/a n/a n/a n/a n/a Second floor none _______ n/a — n/a n/a n/a n/a n/a Attic floor none _ sq. ft. n/a — __ n/a _ n/a n/a n/a n/a Additional information 9. Partition Framing Studs wood, grade, and species 2x4 FJYP #2 Additional information 10. Ceiling Framing Joists wood, grade, and species 2x6 #2 YP Additional information 11. Roof Framing Rafters wood, grade, and species Additional information 12. Roofing 2x6 #2 YP size and spacing 2x4 stud walls pt 16" o_c_— Other n/a _—__ �1 Other 2x8 #2 YP —`—__ Bridging 2x4 #2 YP Roof trusses (see detail) grade and species none Sheathing wood, grade, and species 7/16 OSB--__---- _--_------ —_ ❑x solid El spaced _-.n/a__. o.c. Roofing Comoostion/Shingle _--____— grade Class A _-- size 36 iri he§ type 3-tab fiber- lass -------- -- —g— ------ Underlay 30 Ib felt --_— _—_—__-- weight or thickness _n/a size n/a__-- fastening nailed Built-up roofing _n/a_---____— --_--- — number of plies n1@__— surfacing material n/a _—__— Flashing material Galvanized sheet metal--- -----_____—_ gage or weight 27 --___ — F1 gravel stops 11 snow guards Additional information 25 year warranty ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 2 of 6 VA Form 26-1852 and form FmHA 424-2 13. Gutters and Downspouts Gutters material none -- -- --- — gage or weight n/a -__ _-- size n!a -- shape Downspouts material -none------------ gage or weight n/a size n!a — shape Na number Downspouts connected to11 Storm sewer sanitary sewer dry -well L1 Splash blocks material and size n/a—__--- — Additional information Rain gutters not provided , 14. Lath and Plaster Lath walls El ceilings material n/a --- —__ weight or thickness n/a -- Plaster coats n/a --finish _n/a___________ Dry -wall rx]U walls a ceilings material avl)sum board --_ thickness 1/2 in finish textured and paint_____ Joint treatment tape and float 15. Decorating (Paint, wallpaper, etc.) _ _Rooms Kitchen _ texts Bath _ sam Other (all other room: sam Additional information none 16. Interior Doors and Trim and as above Doors type _Pre hung--___ ------------ material •i Door trim type -Finger Joint —__ material _one —__ Base type Finish doors _Interior white latex paint semi gloss-----_--- trim in Other trim (item, type and location) Interior white latex with semi gloss finish _ _ _ Ceiling Finish Material and Application textured and paint (off-white with flat finish) same as above as above -Awk,. ke —__--__— thickness 1 3/8 inch material pine — — — — — size 3 inch___ 1 semi gloss finish - ------------- Additional information none -------" 17. Windows Windows type Single hung --- make AIenCO or equal --- materialminum __-- sash thick n/a Glass grade n/a - --- thickness _____— sash weights ❑ balances, type n1di. _—__---- head flashing Paint n/a — Trim type Aluminum------ material _Aluminum ----- �Lhil�_-----_ number coats ja�- iQ0L___ Weatherstripping type Plastic --------------- material-n/a------------ Storm sash, number n/a Screens[-] full � half type standard_----- number all screen cloth material s nthetic__ _ Basement windows type none___- — _ material n/a--- ---_ screens, number n/a Storm sash, number n/a Special windows none - - ------------------------- Additional information none 16. Entrances and Exterior Detail Main entrance door material Metal or Fiberglass___ width 36 in thickness 1.75 in Frame material Wood thickness 4.62.` Other entrance doors material _Metal — _------ width _36 in__ thickness 1175 in Frame material Wood— thickness 4.625 ------ Head ----- flashing n/a—__----_--`---_ Weatherstripping - ppIn type 9n/a------____----- saddles n/e Screen doors thickness n/a —_ number _p/g_--_ screen cloth material n/a—___,-- Storm doors thickness n/a—_ number n/a Combination storm and screen doors thickness n/a —_ number n/a — screen cloth material n/a --------------- Shutters hinged [7_j fixed Railings n/a— _---........ Attic louvers (See drawings) Exterior millwork grade and species _none _---_ — _ -- — Paint none -------- _—_— number coats none ----------- Additional information none -- -'- 19. Cabinets and Interior Detail Kitchen cabinets, wall units material Q Ye0�eL-----____—__----- _— lineal feet of shelves n/3L—_ shelf width n/a Base units material Qa­k veneer _-------- counter to Plastic laminate - p-------�--_ edging _Plastic laminate Back and end splash PlasSj��/gRegL__---__— Finish of cabinets Laquer -----------------------__-- number coats 2 -__--- Medicine cabinets makemodel n/a ------------- ----------------------- --- Other cabinets and built-in furniture ---------------------- dditional information none ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 3 of 6 VA Form 26-1852 and form FmHA 424-2 7- 23. Heating ❑ Hot water ❑ Steam ❑ Vapor ❑ One -pipe system ❑ Two -pipe system ❑ Radiators Convectors ❑ Baseboard radiation Make and model Na _------------------------------------ ❑ Radiant panel ❑ floor ❑ wall ❑ ceiling Panel coil material _Na------_____—_ -----P--y Circulator Return pumpMake and model Na ❑_n/a ❑ — -------------- _ ----ca acit n/a -- gpm. Boiler make and model n/a _--------_ Output n/a Btuh. net rating _n/a —__ Btuh. Additional information none Warm air ❑ Gravity 1XJ Forced Type of system Central air ----____--_----------_---- Duct material supply Flex duct -- _— return Duct board Insulation R-6 --- — _ thickness 1.5 inch ❑Outside air intake Furnace: make and model Make and model to be determined —_ Input TBD Btuh. _--- Btuh. output _TBD __ Btuh. Additional information 10 SEER air conditioning -make and model to be determined Space heater ❑floor furnace ❑wall heaterinput n/a —_—_ Btuh. output n/a ---- Btuh. number units n/a ------- Make, model n/a__------- — Additional information none Controls make and types Make and model to be determined ------------------------- — ----------------------- Additional information none Fuel: ❑Coal U oil ❑gas ❑ liq. pet. gas n electric ❑ other nja `°L�--_—_— storage capacity _jnLa___--- Additional information none Firing equipment furnished separately ❑ Gas burner, conversion type Stoker per fieed ❑ bin feed Oil burner ❑pressure atomizing ❑vaporizing n/a----- Make and model _n/a -------------------------------.��..:_—.------------- n/a h; Control n/a Additional information none Electric heating system type to be determined ---_-------_-Input TBD —_ watts @ _TBD— volts output TBD Additional information none Ventilating equipment ❑ attic fan, make and model _none _ _ capacity _n/a cfm. i� kitchen exhaust fan, make and model -vent fan included with overhead cooktonmicrowave _ — -- Other heating, ventilating, or cooling equipment roof ridge vents, soffit vents, ceiling Lan5i_and bathroom exhaust fans Additional information none 24. Electric Wiring Service 51 overhead ❑ underground Panel ❑ fuse box ❑x circuit -breaker make not available— AMP's not avail No. circuits n/a Wiring ❑ conduit ❑ armored cable ox nonmetallic cable ❑ knob and tube ❑ other n/a ------ ------ S ecial outlets 22QXQ1Lit111IIltL1L[O9D1 jQ f�lothes �(YgL_ __---- p �x� range O water heater 0 other EX Doorbell lxl Chimes ❑x Push-button locations front door only - --------------------------------------- Additional information none 25.1-lghting Fixtures Total number of fixtures _tsee dwu1--_ Total allowance for fixtures, typical installation, $ Nontypical installation _none Additional information none Na ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84) Retain this record for three years Page 5 of 6 VA Form 26-1852 and form FmHA 424-2 W= MWIS WX-SPAN n." Joists MAX SPAN RAPIER MAX 3PW — HEJRiFJt - O Axw XlMIOt 40 pw wx &W& um" 01a:%ft KAy un wm 2x4OW0A lr r 2x120Ir04 2r r 2xaOirOA W-11 2-2x40MEM SW 2xi•woa tr—r 2x120WOA 11r W 2xEOitQG 1? 1r *--xxtdiam r-r 2 X 10 • it OA 2C—r 2 X 12 i 24' CA /7r-.r 2 X t 412r O,Q 11--r r• p' **,,MOM 00 M0r GCS am R• N wr axs am OL s PW uW 1lw7►! om tAi'. -, _ • t�`-2 x r-s' .MM d" Ax0WMbK!xt•2I'AA -rama1KwrimlOKXxw . lANWm Oulu 44 XA �fO0OI"MAN TWOOF . M X x• fOsl 1 gxfl! O Ohnim R • 2 X 4 Xx00 9fML K OO r 7NX= AUL 41ML ORkx!MUZZAMW_ & PW= WWX ME Mutt AW OON*9-W �" X ir E 1 10 r�.VM800� ` 4. ALL lTNQV- P,4L_ MWIM V K xR2 lYt'+27 & NOW STEEL ANGLE LINTEL TABLE YIN. BEARING 4 iW s s/tz' �i/XXr x d+/t g +/r x x #Ar s /r X VW X sh4- ! 2 +/2 x 3/l• 11/2' X 3/r —Xx4 SRO 2X4Aw -� 2-2 x 12 w/ M71wt 2-2 x 4 cwvin 2 7 - 2 % 4 TAMER "Isom Mr. t x4 Xummiw O.G UMX#PW ® tD+0t7 - 1Y-0 tY is off_ Woier ei mm ww+► 2r.a.r 14 . WV PURLIN BRACE BIRD YOUTH 1 T,PURUN ANGLE 2 3 TO BE O RIGHT ANGLE TO RAFTER NNOT PRE-BU8_D -r BRACE, INSTALL 2 X 4 BRACE FIRST, THEN JAMB 2 X 4 AGAINST RAFTER k NAIL TO KNEE BRACE ,z 2-18d RAPIER 2 X 4-¢3 1 ,hymn•. A. -,T �(rjYc.° 7•tx� �1 - . �, 2-18d .y 16d O 2 X 4 KNEE BRACE TO RAISED BEAM 24 O.C. 2X4#3 r 1 BIRD MOUTH t TO FIT PURLW ANGLE 2. PU" TO BE O RIGHT ANGLE TO RAFTER 3. DO NOT PRE *r -BUILD BRACE, INSTALL 2 X 4 BRACE FIRST THEN JAMB Z X .4 AGAINST RAFTER & NAIL TO KNEE BRACE 1!/ rLLT rA/fx 2-16d e x 4 ooUNt NO MAW =X x 4 -p KOM%$ 1 x•{ RAWLAW . , �►y 2 X 4-/3 2 X 6- j13 PURUN or ro+. 7UTx mmoams , 2-16d "own �- � ,. . 2 X 4 KNEE BRACE TO RAISED BEAM RR - L ' xa3+uoa.+rac - 0. 24 24 O.C. 2 X 4 #3 s < Q MMN PW AL "b4 - 40ALb 2A1- r4' X4 XQrf011.rtA7L - --. - Is 0 MECcheck Compliance Report 1995 MEC MECcheckSoftware Version 3.4 Release la Data filename: C:\Program Files\Check\MECcheck\Duplex One $bry*k TITLE: Duplex Single Story CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 12/04/03 DATE OF PLANS: December 4, 2003 PROJECT INFORMATION: Edelweiss Gartens 3812/3814 Oldenburg, Lot 27, Block 9, Phase 4 3616/3818 Oldenburg, Lot 28, Block 9, Phase 4 3820/3822 Oldenburg, Lot 29, Block 9, Phase 4 3608/3610 Oldenburg, Lot 67, Block 1, Phase 3 COMPANY INFORMATION: Cathey Homes COMPLIANCF�Passes i� Maximum UA = 530 Your Home = 432 18.5% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E Door 1: Solid Heat Pump 1: Electric Central Air, 6.8 HSPF, 10 SEER Permit Number Checked By/Date Y Gross, = Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2683 30.0 0.0 94 2075 13.0 0.0 145 230 0.640 147 75 0.610 46 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in MECcheckVersion 3.4 Release la and to comply with the mandatory requirements listed in the MEC check Inspection Checklist. Builder/Designer Date / /I ry ?'mod 3 Building Permit Check -sheet • Permit Application • 1 set of drawings. • 1 site plan drawings • 1 detail sheet • 1 spec's package • 1 MECcheck report Dec 11 2003 10:07AM 0EY DEVELOPMENT, INC. 97IW90-0045 p.3 i IP) c-A c, i #z F i2,EwA c.c— 0 Y 7-0 77?'C- eoF) OVA D2Yw,41� ,t�'a !/ Dec_ Zaa 3 Dec 11 2003 10:07AM ox EY DEVELOPMENT, INC. 97IW90-0045 p.2 \ Ile / \/ a i f t t .'A \ %< SETBACK /' ' r ! ` e IMAIM AREA: 2494 sq. AL SLAB AREA: 2,745 sq. IL R — , ° CATHEY Lor. a6 mom i sum: mmLwmss nAR'imm PH m HOIVMS A DRXW: scm 8: t• -m 0-1 • 7 0' I i I I I I I I I 1 30' I I �ZD� PVE I 1 25' SETBACK ---- -------------------+-- I I I I I I I I I I I I I QI II mI Irn LL)I Irn o iDl Im II In I I I 1 1 4' .SIDEWALK 1 , x xxx • , x}cxxx•8 �� V. I - +- - -- - - - ----+- PARKING f. � I I 1 Id0000 0 0 oaf 70' -'15 —1 --s0' L�r�SGa�lr r�i.a►� �gt 5 a - I 0 AO- �!rd -ii HEATED AREA: 2,693 sq. fL SLAB AREA: 2,745 sq. & CATHEY LOT: 27 BLOCK: 9 SUBDIV1SION: EDELWEISS MARTENS, PH IV HOMES ADDRESS: �(cf d &C � 1 O l , (&fl hJ� &GALE: 1" - 20'