HomeMy WebLinkAboutRES2003-03615 1405 ELKTON CT BUILDING PERMITPREPARED 7/15/04, 7:49:31 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/15/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1405 ELKTON CT SUBDIV: SHENANDOAH PH 9 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 569500-0933-0110 APPL NUMBER: 03-00003615 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 1/12/04 DS BLDG, FOUNDATION -SLAB TIME: 17:00 1/12/04 AP O1/09/2004 03:27 PM MALFORD Strings On Setbacks O.K. Slab Ground Installed B115 01 3/03/04 DS BLDG, FRAMING TIME: 17:00 3/03/04 AP 03/03/2004 12:03 PM MALFORD B13J 01 3/11/04 DP BLDG, INSULATION TIME: 17:00 3/11/04 AP 03/10/2004 03:51 PM GCARRILLO B*125 01 7 15 04 BI BLDG, FINAL TIME: 17:00 z 07/14/2004 02:48 PM MALFORD 1 { -------------------------------------- COMMENTS AND NOTES -------------------------------------- City of Colle e Station �ORK REQUEST PAGE 1 REQ/JOB: WF0479150 / 001 PROJECT: REQUEST DATE: 12/11/03 PRINT DATE: 12/11/03 CREW: PRINT TIME: 8:15:44 SCHEDULE LOCATION: 1405 ELKTON CT START:DATES 12/11/03 77845 COMPLETION: 12/11/03 GEN. LOC: COLLEGE STATION LOC ID: 198872 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE BUILDING PERMIT CITY OF COLLEGE STATION - -" ­ 11-01 TEXAS "AVE ' COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003615 Date 12/10/03 Property Address . . . . . . 1405 ELKTON CT Property ID . . . . . . . . . 569500-0933-0110 R # . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 138006 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2091.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 577.00 Plan Check Fee .00 Issue Date . . . . 12/10/03 Valuation . . . . 138006 Expiration Date . . 6/08/04 Qty Unit Charge Per Extension BASE FEE 460.00 39.00 3.0000 THOU BLDG, VAL 100001-500000 117.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQ PMENT ------------------------------------- BUILDING DEPT REPRESENTATIVE: --- ---------------- APPLICANT: �l /� BUILDING PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE 6 COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003615 Page 2 Date 12/10/03 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" ITY IN ALL 350.00 -------------------------------------------------- - - --------------------- BUILDING DEPT REPRESEN ATIVE: APPLICANT: ��--/ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003615 Date 12/10/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Permit Fee Total 577.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1327.00 Paid Credited Due ------------------------------ 577.00 .00 .00 .00 .00 .00 750.00 .00 .00 1327.00 .00 .00 ---------------------------------------------------- BUILDING DEPT REPRESENTATIVE: / APPLICANT: Fa Office Use ".y APP*ATION FOR BUILDING PERMIT DATE: CITY OF COLLEGE STATION APPLICATION # E3 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE # (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US�1 ADDRESS/LOCATION: I�D LOT I BLOCK SUBDIVISION C�7G� jNf-� ti7 i C SEC/PH BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: U? MCC—[ H Li YIA (:I , j lE: 11 U O �--U CP I CONTRACTOR ADDRESS: ELECTRICIAN: S1 -� b L'��,T'�Z,,� PLUMBER: HVAC: rJC�I i 1`1h11?y /'si" 1 \ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req ) DESCRIPTION OF WORK: STRUCTURE USE: 61 N ?'c"� 15N uE HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR. VALUATION: $ I;JCSh Q1,p 7 TOTAL AREA: !� D (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM ti V SEWER TAP: 3 :SIZE If WATER TAP: SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED SIGNATURE OF APPLICANT: IN Laos a3 Plans Examiner NUMBER OF BATHROOMS: HEATED AREA: c)ic. INTERIOR WALL TYPE: EXTERIOR WALL TYPE: LjL FOUNDATION TYPE: UV CAre-P<_— ROOF TYPE: �ftfo(_2I-1I0K DOUBLE TRIPLE DETACHED a CARPORT Official Use Only ents: YE or NO Zoning Official Energy Code Compliance Information % Glazing of exterior walls - 2 0 Insulation R value of exterior walls 13 Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1405EK.rck TITLE: 1405 ELKTON COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 12/03/03 DATE OF PLANS: JUNE 17, 2003 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 668 Your Home UA = 592 11.4% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2091 30.0 0.0 73 Wall 1: Wood Frame, 16" o.c. _ 443 13.0 0.0 28 Window 1: Metal Frame:Double Pane with Low-E 59 0.640 38 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid 38 0.400 15 Wall 2: Wood Frame, 16" o.c. 463 13.0 0.0 34 Window 2: Metal Frame:Double Pane with Low-E 36 0.640 23 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.81 Wall 3: Wood Frame, 16" o.c. 408 13.0 0.0 24 Window 3: Metal Frame:Double Pane with Low-E 112 0.640 72 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o.c. 463 13.0 0.0 Window 4: Metal Frame:Double Pane with Low-E 28 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 212 0.0 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER 36 0.640 18 221 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer /k—� �� Date ?i L oT 10 LOT6 / / .4 / n - . , .1 10'4'u F� _ i V> C LKTON GvvRT 60, 2oW ) 24' PAVE/ -I c/V7 L OT5