HomeMy WebLinkAboutRES2003-03595 2106 SPRING CREEK BUILDING PERMITPREPARED
4/23/04,
7:41:18
INSPECTION
TICKET
PAGE 6
City of
College Station
INSPECTOR:
BUILDING INSPECTOR
DATE 4/23/04
------------------------------------------------------------------------------------------------
ADDRESS
. : 2106 SPRING
CREEK
SUBDIV: EMERALD FOREST #11
CONTRACTOR SUNSET
HOMES
PHONE (979) 680-1033
UINNER
EMERALD
FOREST JOINT VENTURE
PHONE
PVCEL
249000-1120-0100
APPL NUMBER: 03-00003595
------------------------------------------------------------------------------------------------
RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
12/22/03
CW
BLDG, FOUNDATION -SLAB TIME: 17:00
12/22/03
AP
12/22/2003 08:03
AM SSTANLEY
]t
strings ok. rebar
left side backwall
B119 01
1/30/04
OC
BLDG, FRAMING TIME: 17:00
1/30/04
AP
O1/29/2004 01:36
PM MALFORD
B130 01
2/02/04
DS
BLDG, INSULATION
TIME: 17:00
2/03/04
AP
02/02/2004 09:08
AM GCARRILLO
B125 01
4/16/04
BI
BLDG, FINAL TIME:
17:00
B121 02
4/15/04
4/23/04
CA
BI
04/15/2004 03:45
BLDG, FINAL TIME:
PM SSTANLEY
17:00
1
04/22/2004 04:45
PM SSTANLEY
-------------------------------------- COMMENTS AND NOTES--------------------------------------
i
City of College Station
WORK REQUEST
PAGE 1
REQ/JOB:
WF0478298 / 001 PROJECT:
REQUEST DATE:
12/08/03
PRINT DATE:
12/08/03
CREW:
PRINT TIME:
14:13:04
SCHEDULE
DATES
LOCATION:
2106 SPRING CREEK
START:
12/08/03
77845
COMPLETION:
12/08/03
GEN. LOC:
COLLEGE STATION LOC ID: 198926
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
SUNSET HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MALFORD AUTH: MALFORD WORK TYPE:
ROUTINE
4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
AND 3/4" WATER TAPS
4" SEWER AND 3/4" WATER TAPS
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
City of College Station
WORK REQUEST
REQ/JOB: WF0479218 / 001 PROJECT:
CREW:
PAGE 1
REQUEST DATE: 12/11/03
PRINT DATE: 12/11/03
PRINT TIME: 11:02:06
SCHEDULE DATES
LOCATION: 2106 SPRING CREEK START: 12/11/03
77845 COMPLETION: 12/11/03
GEN. LOC: COLLEGE STATION LOC ID: 198926
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code
Task code:
Facility ID
Assigned Department:
CS -CUSTOMER SERVICES CSCS
SET UP NEW UTILITY ACCT SET
OT-CUSTOMER SERVICE
BUILDING PERMIT
Ft �C�TY MOF ,CO'�E'k�T�I'ial�f '
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------------------------------------------
Application Number . . . . . 03-00003595 Date 12/08/03
Property Address . . . . . . 2106 SPRING CREEK
Property ID . . . . . . . . . 249000-1120-0100
R# . . . . . . . . . . . . . R*****
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EMERALD FOREST #11
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 171600
Owner
Contractor
------------------------
------------------------
EMERALD FOREST JOINT
VENTURE SUNSET HOMES
#1
JOHN ALBERNAZ
2103 TABOR RD
9231 BROOKWATER CIRCLE
BRYAN
TX 778035224 COLLEGE STATION
TX 77845
(979) 680-1033
-- Structure Information SINGLE FAMILY
-----
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
i
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
HEATED AREA
2600.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
I-----------------------------------------------------�-------
SERIAL ZONES
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
MA
Permit Fee . . . .
676.00 Plan Check Fee
.00
Issue Date . . . .
12/08/03 Valuation . .
. . 171600
Expiration Date
I
6/06/04
j Qty Unit Charge
Per
Extension
BASE FEE
460.00
72.00 3.0000
7------------------------------------------------------------------------
THOU BLDG, VAL 100001-500000
216.00
I Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
n.
-
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION •
j 1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00003595 Date 12/08/03
'----------------------------------------------------------------
j Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
j MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
j POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
j PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
j of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
i SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
f
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
------------------------------------------------------------------------
Application Number
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
. . _ . 03-00003595
Charged Paid Credited
676.00 676.00 .00
.00 .00 .00
750.00 750.00 .00
1426.00 1426.00 .00
Page 3
Date 12/08/03
Due
.00
.00
.00
.00
--------------------- ---------------------------
1
BUILDING DEPT REPRESENTATIVE: ��(`
APPLICANT: /d�'/I/ //42�
TEMPORARY POLE PERMIT
• CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
------------------------------------------------------------------------
Application Number . .
Property Address . . .
Property ID . . . . . .
Tenant nbr, name . . .
Application description
Subdivision Name . . .
Property Use . . . . .
Property Zoning . . . .
Application valuation .
. . . 03-00003599 Date 12/08/03
. . . 2106 SPRING CREEK
. . . 249000-1120-0100
. . . TEMP POLE
. . . TEMP POLE
. . . EMERALD FOREST #11
. . . RESIDENTIAL
. . . SINGLE FAMILY RESIDENTIAL
0
Owner Contractor
------------------------
EMERALD FOREST JOINT VENTURE SUNSET HOMES
#1 JOHN ALBERNAZ
l 2103 TABOR RD 9231 BROOKWATER CIRCLE
BRYAN TX 778035224 COLLEGE STATION TX 77845
(979) 680-1033
-----------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . MA
Permit Fee . . . . 20.00
Issue Date . . . . 12/08/03 Valuation . . . . 0
------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary
-----------------
Permit Fee Total
Other Fee Total
Grand Total
Charged Paid
--------------------
20.00 20.00
45.00 45.00
65.00 65.00
Credited Due
--------------------
.00 .00
.00 .00
.00 .00
----------
-
--------------------------------
- - - -------------------
BUILDING DEPT �EPRESENTATIVE:
APPLICANT:
Dec 05 03 10:13a S� ET HOMES 40 694-0481 p.3
Energy Code Compliance Information
% Glazing of exterior walls
�
Insulation R value of exterior walls
e
/
Insulation R value of ceiling 1 (flat areas)
o
e
Insulation R value of ceiling 2 (vaulted areas/no attic)
, I?-19
Glazing SHGC
Glazing U-Factor
Go �N
R value of ductwork
�:..
A/C SEER rating
/�
--"W -1 0 •
REScheck Compliance Certificate
1995 MEC
REScheckSoftware Version 3.5 Release lc
Data filename: Untitled.rck
TITLE: Plan # 2600
CITY: Bryan (Brazos County)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 12/02/03
DATE OF PLANS: 12-03
PROJECT INFORMATION:
2106 Spring Creek, College Station, Tx.
COMPANY INFORMATION:
Sunset Homes
COMPLIANCE: Passes
Maximum UA = 611
Your Home UA = 484
20.8% Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
Door 1: Solid
Door 2: Solid
Door 3: Glass
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
2600 30.0 0.0
91
2298 13.0 3.6
129
372
0.670
249
20
0.150
3
18
0.390
7
12
0.390
5
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 NEC
requirements in REkVersion 3.5 Release lc (formerly MECchecl and to comply with the mandatory requirements listed in
the REScheckI Cti�on hecklist./ )
Builder/Designer
Date /;?
•
REScheck Inspection Checklist
1995 MEC
REScheckSoftware Version 3.5 Release lc
DATE: 12/02/03
TITLE: Plan # 2600
Bldg.
Dept. I
Use
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.6 continuous insulation
Comments:
Windows:
1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.150
Comments:
2. Door 2: Solid, U-factor: 0.390
Comments:
3. Door 3: Glass, U-factor: 0.390
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
I leakage must be sealed.
[ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
I 3" clearance from insulation.
I
I Materials Identification:
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] I Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
I the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ l I All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used
for fibrous ducts. Duct tape is not permitted.
[ ) I The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
Circulating Hot Water Systems:
[ l I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 120 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating Mains and Runouts
Temperature ( F)
Up to 1" Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5 1.0
1.5
2.0
140-160
0.5 0.5
1.0
1.5
100-130
0.5 0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
APOICATION FOR BUILDING PERMP
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG ESTATION.TX.US
ADDRESS/LOCATION:
LOT /(/ BLOCK nSUBDIVISION
BUSINESS/OWNER NAME: Kewv Nl I��iNlf7
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS:
ELECTRICIAN: _� j7i�_ PLUMBER:
HVAC: 1) � A% y � GOOD CENTS IResi
CLASS OF WORK
Fa Off a Use 0*
DATE: t �
APPLICATION# -C ✓� 7C/
TEMP POLE # A�2 a
PHONE: / VQ
PHONE:
only): �--
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION VING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Rej) REMODEURENOVAT�9N SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS ROJECT REGISTRATION# EABP
� ;
VALUATION: $ TOTAL AREA: HEATED AREA:
(Oodf 6f Vabor and Mated-al�.
Q PUBLIC SEWER i I I NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
dSEWER TAP:
dWATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE
U
IZE
S
SIZE
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
SINGLE a DOUBLE Er
ATTA ED DEC iED a C
SIGNATURE OF APPLICANT:
CIA I.���
Plans Examiner
01
y�.
TRIPLE a /
:ARPORT a
Only
COMments:
YES r NO
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating