Loading...
HomeMy WebLinkAboutRES2003-03595 2106 SPRING CREEK BUILDING PERMITPREPARED 4/23/04, 7:41:18 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/23/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 2106 SPRING CREEK SUBDIV: EMERALD FOREST #11 CONTRACTOR SUNSET HOMES PHONE (979) 680-1033 UINNER EMERALD FOREST JOINT VENTURE PHONE PVCEL 249000-1120-0100 APPL NUMBER: 03-00003595 ------------------------------------------------------------------------------------------------ RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/22/03 CW BLDG, FOUNDATION -SLAB TIME: 17:00 12/22/03 AP 12/22/2003 08:03 AM SSTANLEY ]t strings ok. rebar left side backwall B119 01 1/30/04 OC BLDG, FRAMING TIME: 17:00 1/30/04 AP O1/29/2004 01:36 PM MALFORD B130 01 2/02/04 DS BLDG, INSULATION TIME: 17:00 2/03/04 AP 02/02/2004 09:08 AM GCARRILLO B125 01 4/16/04 BI BLDG, FINAL TIME: 17:00 B121 02 4/15/04 4/23/04 CA BI 04/15/2004 03:45 BLDG, FINAL TIME: PM SSTANLEY 17:00 1 04/22/2004 04:45 PM SSTANLEY -------------------------------------- COMMENTS AND NOTES-------------------------------------- i City of College Station WORK REQUEST PAGE 1 REQ/JOB: WF0478298 / 001 PROJECT: REQUEST DATE: 12/08/03 PRINT DATE: 12/08/03 CREW: PRINT TIME: 14:13:04 SCHEDULE DATES LOCATION: 2106 SPRING CREEK START: 12/08/03 77845 COMPLETION: 12/08/03 GEN. LOC: COLLEGE STATION LOC ID: 198926 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- AND 3/4" WATER TAPS 4" SEWER AND 3/4" WATER TAPS Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE City of College Station WORK REQUEST REQ/JOB: WF0479218 / 001 PROJECT: CREW: PAGE 1 REQUEST DATE: 12/11/03 PRINT DATE: 12/11/03 PRINT TIME: 11:02:06 SCHEDULE DATES LOCATION: 2106 SPRING CREEK START: 12/11/03 77845 COMPLETION: 12/11/03 GEN. LOC: COLLEGE STATION LOC ID: 198926 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code Task code: Facility ID Assigned Department: CS -CUSTOMER SERVICES CSCS SET UP NEW UTILITY ACCT SET OT-CUSTOMER SERVICE BUILDING PERMIT Ft �C�TY MOF ,CO'�E'k�T�I'ial�f ' COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------------------------------------------ Application Number . . . . . 03-00003595 Date 12/08/03 Property Address . . . . . . 2106 SPRING CREEK Property ID . . . . . . . . . 249000-1120-0100 R# . . . . . . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EMERALD FOREST #11 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 171600 Owner Contractor ------------------------ ------------------------ EMERALD FOREST JOINT VENTURE SUNSET HOMES #1 JOHN ALBERNAZ 2103 TABOR RD 9231 BROOKWATER CIRCLE BRYAN TX 778035224 COLLEGE STATION TX 77845 (979) 680-1033 -- Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK i IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2600.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC I-----------------------------------------------------�------- SERIAL ZONES Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 676.00 Plan Check Fee .00 Issue Date . . . . 12/08/03 Valuation . . . . 171600 Expiration Date I 6/06/04 j Qty Unit Charge Per Extension BASE FEE 460.00 72.00 3.0000 7------------------------------------------------------------------------ THOU BLDG, VAL 100001-500000 216.00 I Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT n. - APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION • j 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------------------------------------------ Page 2 Application Number . . . . . 03-00003595 Date 12/08/03 '---------------------------------------------------------------- j Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) j MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. j POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED j PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating j of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED i SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 f - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ------------------------------------------------------------------------ Application Number Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total . . _ . 03-00003595 Charged Paid Credited 676.00 676.00 .00 .00 .00 .00 750.00 750.00 .00 1426.00 1426.00 .00 Page 3 Date 12/08/03 Due .00 .00 .00 .00 --------------------- --------------------------- 1 BUILDING DEPT REPRESENTATIVE: ��(` APPLICANT: /d�'/I/ //42� TEMPORARY POLE PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ------------------------------------------------------------------------ Application Number . . Property Address . . . Property ID . . . . . . Tenant nbr, name . . . Application description Subdivision Name . . . Property Use . . . . . Property Zoning . . . . Application valuation . . . . 03-00003599 Date 12/08/03 . . . 2106 SPRING CREEK . . . 249000-1120-0100 . . . TEMP POLE . . . TEMP POLE . . . EMERALD FOREST #11 . . . RESIDENTIAL . . . SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ EMERALD FOREST JOINT VENTURE SUNSET HOMES #1 JOHN ALBERNAZ l 2103 TABOR RD 9231 BROOKWATER CIRCLE BRYAN TX 778035224 COLLEGE STATION TX 77845 (979) 680-1033 ----------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 12/08/03 Valuation . . . . 0 ------------------------------------------------------------------------ Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 Credited Due -------------------- .00 .00 .00 .00 .00 .00 ---------- - -------------------------------- - - - ------------------- BUILDING DEPT �EPRESENTATIVE: APPLICANT: Dec 05 03 10:13a S� ET HOMES 40 694-0481 p.3 Energy Code Compliance Information % Glazing of exterior walls � Insulation R value of exterior walls e / Insulation R value of ceiling 1 (flat areas) o e Insulation R value of ceiling 2 (vaulted areas/no attic) , I?-19 Glazing SHGC Glazing U-Factor Go �N R value of ductwork �:.. A/C SEER rating /� --"W -1 0 • REScheck Compliance Certificate 1995 MEC REScheckSoftware Version 3.5 Release lc Data filename: Untitled.rck TITLE: Plan # 2600 CITY: Bryan (Brazos County) STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 12/02/03 DATE OF PLANS: 12-03 PROJECT INFORMATION: 2106 Spring Creek, College Station, Tx. COMPANY INFORMATION: Sunset Homes COMPLIANCE: Passes Maximum UA = 611 Your Home UA = 484 20.8% Better Than Code (UA) Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E Door 1: Solid Door 2: Solid Door 3: Glass Furnace 1: Forced Hot Air, 78 AFUE Air Conditioner 1: Electric Central Air, 12 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2600 30.0 0.0 91 2298 13.0 3.6 129 372 0.670 249 20 0.150 3 18 0.390 7 12 0.390 5 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 NEC requirements in REkVersion 3.5 Release lc (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckI Cti�on hecklist./ ) Builder/Designer Date /;? • REScheck Inspection Checklist 1995 MEC REScheckSoftware Version 3.5 Release lc DATE: 12/02/03 TITLE: Plan # 2600 Bldg. Dept. I Use Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.6 continuous insulation Comments: Windows: 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.150 Comments: 2. Door 2: Solid, U-factor: 0.390 Comments: 3. Door 3: Glass, U-factor: 0.390 Comments: Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air I leakage must be sealed. [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a I 3" clearance from insulation. I I Materials Identification: [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on I the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ l I All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous ducts. Duct tape is not permitted. [ ) I The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I Circulating Hot Water Systems: [ l I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 120 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) APOICATION FOR BUILDING PERMP CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG ESTATION.TX.US ADDRESS/LOCATION: LOT /(/ BLOCK nSUBDIVISION BUSINESS/OWNER NAME: Kewv Nl I��iNlf7 CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: ELECTRICIAN: _� j7i�_ PLUMBER: HVAC: 1) � A% y � GOOD CENTS IResi CLASS OF WORK Fa Off a Use 0* DATE: t � APPLICATION# -C ✓� 7C/ TEMP POLE # A�2 a PHONE: / VQ PHONE: only): �-- ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION VING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Rej) REMODEURENOVAT�9N SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS ROJECT REGISTRATION# EABP � ; VALUATION: $ TOTAL AREA: HEATED AREA: (Oodf 6f Vabor and Mated-al�. Q PUBLIC SEWER i I I NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: dSEWER TAP: dWATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE U IZE S SIZE INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: SINGLE a DOUBLE Er ATTA ED DEC iED a C SIGNATURE OF APPLICANT: CIA I.��� Plans Examiner 01 y�. TRIPLE a / :ARPORT a Only COMments: YES r NO Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating