HomeMy WebLinkAboutRES2003-03590 302 SAPPHIRE DR BUILDING PERMITCity of Collegge S '-ti-&n--- - r-•- �. F]ORQUEST�, PAGE 1 REQ/JOB: WF0478302 / 001 PROJECT: REQUEST DATE:PRINT DATE: 08 12//03 CREW: PRINT TIME: 14:17:47 LOCATION: 302 SAPPHIRE DR SCHEDULE STTART:DATES 12/08/03 77845 COMPLETION: 12/08/03 GEN. LOC: COLLEGE STATION LOC ID: 198684 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE SWR 4" WTR 3/4" ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- SWR 4" WTR 3/4" Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE PREPARED 3/05/04, 7:42:08 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/05/04 ------------------------------------------------------------------------------------------- ADDRESS . : 302 SAPPHIRE DR SUBDIV: STONE FOREST PH 3 CONTRACTOR ELEGANT LIVING HOMES PHONE (979) 823-0638 OWNER JOHNSON INVESTMENTS INC PHONE PARCEL 585200-0306-0340 APPL NUMBER: 03-00003590 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/15/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/15/03 AP 12/15/2003 07:27 AM SSTANLEY Slab Ground Installed Strings On Setbacks O.K. 115 01 1/16/04 TB BLDG, FRAMING TIME: 17:00 1/16/04 AP 01/15/2004 09:50 AM GCARRILLO B1 0 01 1/20/04 TB BLDG, INSULATION TIME: 17:00 ? 1/20/04 AP 01/20/2004 08:17 AM SSTANLEY 5 01 3 5/0 I BLDG, FINAL TIME: 17:00 * ��OC 03/04/2004 02:01 PM MALFORD -------------------------------------- COMMENTS AND NOTES -------------------------------------- tuo �- 1 lFo, Al (20-1 =ILDIr q._F Rj4I.T CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003590 Date 12/08/03 Property Address . . . . . . 302 SAPPHIRE DR Property ID . . 585200-0306-0340 R # . . . . . . . . . • • . . R115944 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . STONE FOREST PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 158994 Owner Contractor ------------------------ ------------------------ JOHNSON INVESTMENTS INC ELEGANT LIVING HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN TX 768340800 PO BOX 7063 BRYAN TX 77805 (979) 823-0638 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SHEETROCK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 3150.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GC Permit Fee . . . . 637.00 Plan Check Fee .00 Issue Date . . . . 12/08/03 Valuation . . . . 158994 Expiration Date 6/06/04 Qty Unit Charge Per Extension BASE FEE 460.00 59.00 3.0000 THOU BLDG, VAL 100001-500000 177.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------------------- BUILDING DE APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION• 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003590 Date 12/08/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00003590 Date 12/08/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 637.00 637.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1387.00 1387.00 .00 .00 ---------------------- -%- -- --------------------------- BUILDING DEPT REPRESENTATI�. APPLICANT: TEMPORARY POLE PERMIT 0 CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID R# . . . . . . . . . . . . . Tenant nbr, name . . . . . . Application description . . . Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 03-00003591 Date 12/08/03 302 SAPPHIRE DR 585200-0306-0340 R115944 TEMP POLE TEMP POLE STONE FOREST PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ JOHNSON INVESTMENTS INC ELEGANT LIVING HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN TX 768340800 PO BOX 7063 BRYAN TX 77805 (979) 823-0638 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GC Permit Fee . . . . 20.00 Issue Date . . . . 12/08/03 Valuation . . . . 0 Fee summary ----------------- Permit Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 20.00 20.00 ----------------------- BUILDING DEPT REPRESENTATIVE.;--, APPLICANT: Credited Due -------------------- .00 .00 .00 .00 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W WW.CI.COLLEG E-STATION.TX.US ADDRESS/LOCATION: ?x )2 For Office Use Only DATE: APPLICATION # 0 3 ) ) I LJ TEMP POLE # o e G-�T� Qvi ­7 7�NS LOT 2 � _ BLOCK �0 ✓ •SUBDIVISION � nf? {��� T ►l(rS�' BUSINESS/OWNER NAME: a euc� 01 L1 I i"-'�PHONE: 48 Z 3-0&3 J� .1 CONTRACTOR/HOMEOWNER: bawl J � 22 __ y CONTRACTOR ADDRESS: P (D 1 J, & PHONE: fix, -7 7�L) S lle ELECTRICIAN: CAI1� 0/1 EI-PdPLUMBER: H k HVAC: Oooat:. c— GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: C YIS�YIi�-�tM O-F oew e Ct UJ e- ( ( ( V�-91 51 VAO tp �,4v�� VV (-_)yy-\ -e J STRUCTURE USE: e,+-I Ul HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: 3 I cDO HEATED AREA: I (Cost of Labor a a s�^+QQ ❑ PUBLIC SEWER 158 I "1-1 NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 3 SEWER TAP: 4 INTERIOR WALL TYPE:IZE S-lz( Gt 5Yl e�i-r2�c�L 'WATER TAP: I I EXTERIOR WALL TYPE: � ❑ OTHER TAP: SIZE FOUNDATION TYPE: y C CY1 Gl_2"1 -P 6Y1 Q 12:�O, TEMP POLE SIZE ROOF TYPE: �l C-b"�p� I -V) 6Yl GARAGE TYPE: SINGLE UBLE TRIPLE FIATTACHED ��,em E CARPORT t I a',�,i���l SIGNATURE OF APPLICANT: Official Use Only 03 03 E orNO Plans Examiner Zoning Official • is Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls I -;s Insulation R value of ceiling 1 (flat areas) ✓ Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC 3� Glazing U-Factor . (o 0 ✓ R value of ductwork 0 ✓ A/C SEER rating 1 Z MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: Plan 2409 Lot 34 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 12/02/03 DATE OF PLANS: Oct 03 PROJECT INFORMATION: 302 Sapphire Drive College Station, Texas 77845 COMPANY INFORMATION: ELH-Elegant Living Homes, Inc. P. O. Box 7063 Bryan, Texas 77845 NOTES: Call Bill when ready 229-2045 or Cindy 777-0703 or Office 823-0638 COMPLIANCE: Passes Maximum UA = 644 Your Home = 528 18.0% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Raised or Energy Truss Exterior Wall l: Wood Frame, 16" o.c. Window: 6020: Other Window: 3060: Other Window: 6016: Other Window: 2060: Other Window: 1060: Other Window: 5050: Other Window: 2860: Other Window: 3070: Other Window: 3050: Other Door: 3/0: Solid Door: 2/8: Solid Air Conditioner 1: Electric Central Air, 12 SEER • Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2355 13.0 0.0 165 54 19.0 0.0 3 2489 0.0 30.0 149 12 0.600 7 72 0.600 43 18 0.600 11 24 0.600 14 12 0.600 7 17 0.600 10 48 0.600 29 105 0.600 63 30 0.600 18 20 0.170 3 36 0.170 6 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calcul tions submitted with the permit application. The proposed building has been designed to meet the 20DO IE re a in MECcheck Version 3.2 Release Ib. Builder/Designer Date 2 MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 12/02/03 TITLE: Plan 2409 Lot 34 Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-13.0 cavity insulation Comments: 2. Ceiling 2: Raised or Energy Truss, R-19.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above -Grade Walls: 1. Exterior Wall 1: Wood Frame, 16" o.c., R-30.0 continuous insulation Comments: Windows: 1. Window: 6020: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' x 2' Eyebrow 2. Window: 3060: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x 6' Window 3. Window: 6016: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' xl'6" Transom Window 4. Window: 2060: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 2 x 6 Window 5. Window: 1060: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: F x 6' Window 6. Window: 5050: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 50" x50" PBSC 7. Window: 2860: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 2'8" x 6' Window 8. Window: 3070: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No • 0 Comments: Y x T Window [ ] I 9. Window: 3050: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x 5' Window I Doors: [ ] I 1. Door: 3/0: Solid, U-factor: 0.170 Comments: Y x 6' 8" Fiberglass Door [ ] 2. Door: 2/8: Solid, U-factor: 0.170 Comments: 2'8" x 68" Door I Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number I [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. I Materials Identification: [ ] I Materials and equipment must be installed in accordint to the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. I Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% 1-1 0 of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. 0 0 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1 „ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Ding System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)