HomeMy WebLinkAboutRES2003-03590 302 SAPPHIRE DR BUILDING PERMITCity of Collegge S '-ti-&n--- - r-•- �.
F]ORQUEST�, PAGE 1
REQ/JOB: WF0478302 / 001 PROJECT: REQUEST DATE:PRINT DATE: 08 12//03
CREW: PRINT TIME: 14:17:47
LOCATION: 302 SAPPHIRE DR SCHEDULE
STTART:DATES 12/08/03
77845 COMPLETION: 12/08/03
GEN. LOC: COLLEGE STATION LOC ID: 198684
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
SWR 4" WTR 3/4"
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
SWR 4" WTR 3/4"
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
PREPARED 3/05/04, 7:42:08 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/05/04
-------------------------------------------------------------------------------------------
ADDRESS . : 302 SAPPHIRE DR SUBDIV: STONE FOREST PH 3
CONTRACTOR ELEGANT LIVING HOMES PHONE (979) 823-0638
OWNER JOHNSON INVESTMENTS INC PHONE
PARCEL 585200-0306-0340
APPL NUMBER: 03-00003590 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/15/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/15/03 AP 12/15/2003 07:27 AM SSTANLEY
Slab Ground Installed
Strings On Setbacks O.K.
115 01 1/16/04 TB BLDG, FRAMING TIME: 17:00
1/16/04 AP 01/15/2004 09:50 AM GCARRILLO
B1 0 01 1/20/04 TB BLDG, INSULATION TIME: 17:00
? 1/20/04 AP 01/20/2004 08:17 AM SSTANLEY
5 01 3 5/0 I BLDG, FINAL TIME: 17:00
* ��OC 03/04/2004 02:01 PM MALFORD
-------------------------------------- COMMENTS AND NOTES --------------------------------------
tuo
�- 1 lFo, Al (20-1
=ILDIr q._F Rj4I.T
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003590 Date 12/08/03
Property Address . . . . . . 302 SAPPHIRE DR
Property ID . . 585200-0306-0340
R # . . . . . . . . . • • . . R115944
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . STONE FOREST PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 158994
Owner Contractor
------------------------ ------------------------
JOHNSON INVESTMENTS INC ELEGANT LIVING HOMES
PO BOX 800 WILLIAM C MORRIS
COLEMAN TX 768340800 PO BOX 7063
BRYAN TX 77805
(979) 823-0638
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE SHEETROCK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 3150.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 252.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GC
Permit Fee . . . . 637.00 Plan Check Fee .00
Issue Date . . . . 12/08/03 Valuation . . . . 158994
Expiration Date 6/06/04
Qty Unit Charge Per Extension
BASE FEE 460.00
59.00 3.0000 THOU BLDG, VAL 100001-500000 177.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION•
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00003590 Date 12/08/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Page
3
Application Number
. . . . . 03-00003590
Date
12/08/03
----------------------------------------------------------------------------
Other Fees . . .
. . . . . . SEWER TAP 4" CITY
INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary
Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total
637.00 637.00
.00
.00
Plan Check Total
.00 .00
.00
.00
Other Fee Total
750.00 750.00
.00
.00
Grand Total
1387.00 1387.00
.00
.00
---------------------- -%- -- ---------------------------
BUILDING DEPT REPRESENTATI�.
APPLICANT:
TEMPORARY POLE PERMIT
0 CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID
R# . . . . . . . . . . . . .
Tenant nbr, name . . . . . .
Application description . . .
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
03-00003591 Date 12/08/03
302 SAPPHIRE DR
585200-0306-0340
R115944
TEMP POLE
TEMP POLE
STONE FOREST PH 3
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner Contractor
------------------------ ------------------------
JOHNSON INVESTMENTS INC ELEGANT LIVING HOMES
PO BOX 800 WILLIAM C MORRIS
COLEMAN TX 768340800 PO BOX 7063
BRYAN TX 77805
(979) 823-0638
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . GC
Permit Fee . . . . 20.00
Issue Date . . . . 12/08/03 Valuation . . . . 0
Fee summary
-----------------
Permit Fee Total
Grand Total
Charged Paid
--------------------
20.00 20.00
20.00 20.00
-----------------------
BUILDING DEPT REPRESENTATIVE.;--,
APPLICANT:
Credited Due
--------------------
.00 .00
.00 .00
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W WW.CI.COLLEG E-STATION.TX.US
ADDRESS/LOCATION:
?x
)2
For Office Use Only
DATE:
APPLICATION # 0 3 ) ) I LJ
TEMP POLE # o
e G-�T� Qvi 7 7�NS
LOT 2 � _ BLOCK �0 ✓ •SUBDIVISION � nf? {��� T ►l(rS�'
BUSINESS/OWNER NAME: a euc� 01 L1 I i"-'�PHONE: 48 Z 3-0&3
J� .1 CONTRACTOR/HOMEOWNER: bawl
J � 22 __
y
CONTRACTOR ADDRESS: P (D 1 J, &
PHONE:
fix, -7 7�L) S
lle ELECTRICIAN: CAI1� 0/1 EI-PdPLUMBER: H k
HVAC: Oooat:. c— GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: C YIS�YIi�-�tM O-F oew e
Ct UJ e- ( ( ( V�-91 51 VAO tp �,4v�� VV (-_)yy-\ -e
J
STRUCTURE USE: e,+-I Ul
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: 3 I cDO HEATED AREA: I
(Cost of Labor a a s�^+QQ
❑ PUBLIC SEWER 158 I "1-1 NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 3
SEWER TAP:
4
INTERIOR WALL TYPE:IZE
S-lz( Gt 5Yl e�i-r2�c�L
'WATER TAP:
I I
EXTERIOR WALL TYPE:
�
❑ OTHER TAP:
SIZE
FOUNDATION TYPE:
y
C CY1 Gl_2"1 -P 6Y1 Q 12:�O,
TEMP POLE
SIZE
ROOF TYPE:
�l
C-b"�p� I -V) 6Yl
GARAGE TYPE:
SINGLE UBLE TRIPLE
FIATTACHED
��,em
E CARPORT
t I
a',�,i���l
SIGNATURE OF APPLICANT:
Official Use Only
03 03 E orNO
Plans Examiner Zoning Official
•
is
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls I -;s
Insulation R value of ceiling 1 (flat areas) ✓
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC 3�
Glazing U-Factor . (o 0 ✓
R value of ductwork 0 ✓
A/C SEER rating 1 Z
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: Plan 2409 Lot 34
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 12/02/03
DATE OF PLANS: Oct 03
PROJECT INFORMATION:
302 Sapphire Drive
College Station, Texas 77845
COMPANY INFORMATION:
ELH-Elegant Living Homes, Inc.
P. O. Box 7063
Bryan, Texas 77845
NOTES:
Call Bill when ready 229-2045 or
Cindy 777-0703 or
Office 823-0638
COMPLIANCE: Passes
Maximum UA = 644
Your Home = 528
18.0% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Raised or Energy Truss
Exterior Wall l: Wood Frame, 16" o.c.
Window: 6020: Other
Window: 3060: Other
Window: 6016: Other
Window: 2060: Other
Window: 1060: Other
Window: 5050: Other
Window: 2860: Other
Window: 3070: Other
Window: 3050: Other
Door: 3/0: Solid
Door: 2/8: Solid
Air Conditioner 1: Electric Central Air, 12 SEER
•
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
2355
13.0
0.0
165
54
19.0
0.0
3
2489
0.0
30.0
149
12
0.600
7
72
0.600
43
18
0.600
11
24
0.600
14
12
0.600
7
17
0.600
10
48
0.600
29
105
0.600
63
30
0.600
18
20
0.170
3
36
0.170
6
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calcul tions submitted with the permit application. The proposed building has been
designed to meet the 20DO IE re a in MECcheck Version 3.2 Release Ib.
Builder/Designer Date 2
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 12/02/03
TITLE: Plan 2409 Lot 34
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-13.0 cavity insulation
Comments:
2. Ceiling 2: Raised or Energy Truss, R-19.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above -Grade Walls:
1. Exterior Wall 1: Wood Frame, 16" o.c., R-30.0 continuous insulation
Comments:
Windows:
1.
Window: 6020: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: 6' x 2' Eyebrow
2.
Window: 3060: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: Y x 6' Window
3.
Window: 6016: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: 6' xl'6" Transom Window
4.
Window: 2060: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: 2 x 6 Window
5.
Window: 1060: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: F x 6' Window
6.
Window: 5050: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: 50" x50" PBSC
7.
Window: 2860: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
Comments: 2'8" x 6' Window
8.
Window: 3070: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
] Yes [ ] No
• 0
Comments: Y x T Window
[ ] I 9. Window: 3050: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments: Y x 5' Window
I
Doors:
[ ] I 1. Door: 3/0: Solid, U-factor: 0.170
Comments: Y x 6' 8" Fiberglass Door
[ ] 2. Door: 2/8: Solid, U-factor: 0.170
Comments: 2'8" x 68" Door
I
Heating and Cooling Equipment:
[ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
I
[ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
I
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
I
Materials Identification:
[ ] I Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] I Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
I
Duct Insulation:
[ ] I Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
I
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
1-1
0
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
0
0
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1 „
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Ding System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)