HomeMy WebLinkAboutRES2003-03588 309 SAPPHIRE DR BUILDING PERMITPREPARED 3/19/04, 12:00:22 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/19/04
------------------------------------------------------------------------------------------------
ADDRESS . : 309 SAPPHIRE DR SUBDIV: STONE FOREST PH 3
CONTRACTOR ELEGANT LIVING HOMES PHONE (979) 823-0638
OWNER JOHNSON INVESTMENTS INC PHONE
PARCEL 585200-0304-0140
APPL NUMBER: 03-00003588 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/17/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
12/17/03 AP 12/16/2003 01:53 PM GCARRILLO
afternoon
Slab Ground Installed
A 01 2/04/04 TB BLDG, FRAMING TIME: 17:00
2/04/04 AP 02/04/2004 09:00 AM SSTANLEY
B130 01 2/06/04 TB BLDG, INSULATION TIME: 17:00
2/06/04 AP 02/06/2004 08:53 AM MALFORD
B;25 01 /1 /04 BLDG, FINAL TIME: 17:00
0 I� 03/19/2004 08:31 AM SSTANLEY f
_0---------------------------------- COMMENTS AND NOTES --------------------------------------
s 7*L. AwA/ ilk2tp4i' o n! n s4 Q 1�
City Order, 416M
MACARTKA URVEYS INC. Dead P&St• O.R. 961/297,
F,O. 80X 4502 O.R. 410j1 _;
BRYAN TEXAS 77005
(070) 771.6#09
B3mj[et EasEffimte
0.1R. 57 6/752
I D.R. 581/713
I O-R. 994/568
bRon.0 c 5cu,c ; $
O.R. 2504/81
IN MST f i
L07 G I 40T 5 LOY
I
I
o TWO .. —.�� 20 PI eL l c UTILITY ease6n,T
oe,ol,.y,. MRXEL�.q
5/6-IROH KMA PER rI.ATIII
robe PADAMnAK , "T,6
GAr R.P L.S. ND.970P
[A91 I
®�s. I I l
iYT I�TR I LT I ONS 1
1
S,QL�pAR .
® oisiURSED�. Ol/'iW aL&NSTIa,cTlp{
-6T antr F3LpGK 4
I�OT 14 LOT 15
B
C d l+
LOT 13
6ATE 509Lae I h s
—1 of s � I^
�+
Bullep rALILIr1E5 Z' ..I
1
�6(141 Ta4 w.vy�L � I I
ON AED V ab Laaaf
T,, FMVE BURIED rAL ILITlES I1J:L7!"O AAI
Trt OROLM MO 6EFOR! AM' IATIOM
OTAST TFe Owlp{ Or TFi P6(IL, MO j I
TMe 1. 0TA[ NOTIP,SaapTILr Y�9-�41 L 46 IR i �MgO�D 00 GpNr�ATrD �Ow
0
I.�� N• M1
' 1 .............. ..... ..... ...............
T_ 1°07-45•W R _ ..
N yE-r S' PIII.IG UTILITY CASa�fNT
s: - 74.9S'M-w..-
^,
309 SAPPHIRE DRIVE
w• C.O.W. MR r"T
14t FOu teen (14), Mack Fbur (4), 97UM FORR" S11eD1 SIGN, FHMM 3, an
addition to the City of College Station, Brazos Canty, Waxen, agogrding
to thQ plat xeooL,dod in Volww 5575, page 55, 0tf1ois11 17AKX=de of Br*,ZW
county, 'i'MM.
X. June& W. ftchrtbw, Regia7texed FrofesQiC17R1 Lard 91rvgjor, No. 2089, do
h=tby certify that thin pat oorseatly repremmta a Survey made by n� ar
under my direction, on the greuud, Deow ber 8, 2003.
ZliA p]st "M prepmred for the p=p:)sa of BCxcm &Wvey+' fort Blelgmt Living
130les. #03-3605
There are n0 v5.a;ible Ott' appdSV t intrWims other than Ume &Inm bcrI ln.
Based cn the iafczmticn scaled from the FaM OWtp Ut W rebru,,yr 9, 2M(),
Hanel No. 48041CO205 p, this property d w riot lie within a deaignatcd
100-year f109d area.
60 39Vd S3WOH ONIAI-1 iNV93-13 909TSZ86L6 be:0T EOOZ/5T/ZT
City of College Station
WOR EQUEST
PAGE 1
REQ/JOB:
WF0478310 U01 PROJECT:
REQUEST DPRINT ATE:
12/08/03
CREW:
PRINT TIME:
14:19:32
SCHEDULE
DATES
LOCATION:
309 SAPPHIRE DR
START:
12/08/03
77845
COMPLETION:
12/08/03
GEN. LOC:
CYCLES LOC ID: 198632
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
ELEGANT LIVING HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
GCARRILLO AUTH: GCARRILLO WORK TYPE:
ROUTINE
SWR 4"
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
WTR 3/4"
"
3 4 "
CatRegory
codeR CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department:
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
OT-CUSTOMER SERVICE
BUILDING PERMIT
• CITY 0'F` COL'LEGE-STATION•
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00003588 Date 12/08/03
Property Address . . .
. . . 309 SAPPHIRE DR
Property ID . . . . . .
. . . 585200-0304-0140
R # . . . . . . . . . .
. . . R115959
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . STONE FOREST PH 3
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . SINGLE FAMILY RESIDENTIAL
Application valuation .
. . . 150216
Owner
Contractor
------------------------
JOHNSON INVESTMENTS INC
------------------------
ELEGANT LIVING HOMES
PO BOX 800
WILLIAM C MORRIS
COLEMAN TX
768340800 PO BOX 7063
BRYAN TX 77805
(979) 823-0638
------ Structure Information
SINGLE FAMILY -----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE SHEETROCK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 2276.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 252.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . GC
Permit Fee . . . .
613.00 Plan Check Fee .00
Issue Date . . . . 12/08/03
Valuation . . . . 150216
Expiration Date . .
6/06/04
Qty Unit Charge Per
Extension
BASE FEE 460.00
51.00 3.0000 THOU
BLDG, VAL 100001-500000 153.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT
SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE
PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS WITHIN
20 FEET OF MECHANICAL EQUIPMENT
--------------------------------------
BUILDING DEPT REPRESE ATIVE:
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00003588 Date 12/08/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER —TAR Vi CITY INSTALL 350.00
BUILDING E
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00003588
Date
12/08/03
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
613.00
613.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1363.00
1363.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION 40
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID
R# . . . . . . . . . . . . .
Tenant nbr, name . . . . . .
Application description . . .
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
03-00003589 Date 12/08/03
309 SAPPHIRE DR
585200-0304-0140
R115959
TEMP POLE
TEMP POLE
STONE FOREST PH 3
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner Contractor
------------------------ ------------------------
JOHNSON INVESTMENTS INC ELEGANT LIVING HOMES
PO BOX 800 WILLIAM C MORRIS
COLEMAN TX 768340800 PO BOX 7063
BRYAN TX 77805
(979) 823-0638
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . GC
Permit Fee . . . . 20.00
Issue Date . . . . 12/08/03 Valuation . . . . 0
Fee summary
-----------------
Permit Fee Total
Grand Total
------------------
BUILDING I
APPLICANT
Charged Paid
--------------------
20.00 20.00
20.00 20.00
Credited Due
--------------------
.00 .00
.00 .00
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION:
LOT ) � ✓/ BLOCK
BUSINESS/OWNER NAME
For Ofte Ux
DATE: C/ ro
APPLICATION #
TEMP POLE #
C . C�) I I Me C- z -6 6yA -� -7 &16
'T 1 SUBDIVISION S_�Orle �DreS-t ehcs-
V(r�G T � e!Y , PHONE: '�23 "L-Xo-J)
CONTRACTOR/HOMEOWNER: L"_VYl � PHONE:
CONTRACTOR ADDRESS: 0,U . 6I;x -� 0co3 4-1 V-) Ty -
ELECTRICIAN:
, C'l7) ( �J 6'ed PLUMBER: � A �[ L t
HVAC: I `Ooa!`i�:. 1'L GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Rnneq``) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: W yAs4p,tc h' tlYN O-f-_ n�titi 5 1 vial C' -iiti (��(
STRUCTURE USE:
t c1e'*%A u(L
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: `� C S
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: HEATED AREA: 2Z%%
(Cost of Labor and Mated -
PUBLIC SEWER 1,9 I (o NUMBER OF BEDROOMS: T
SEPTIC/TREATMENT SYSTEM
11
Z SEWER TAP: Lf
0 WATER TAP:
❑ OTHER TAP:
I1 TEMP POLE
GARAGE TYPE
SIZE
SIZE
SINGLE 2?
ATTACHED I /j,
SIGNATURE OF APPLICANT: GC / -
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE: C� UIC�ec� fac�
EXTERIOR WALL TYPE: C1'skee y? _(e / 13CI C
FOUNDATION TYPE: 0V_nC -etQ G+Yl CA fe& /t -lam
ROOF TYPE: k_tjm/ cO. I TZ 0V1
IBLE ZTRIPLE
9�1�91 [ CAR
j'ORT
Official Use Only
ments:
N �A 0� (YES` or NO
Plans Examiner Zoning Official
•
•
Energy Code Compliance Information
% Glazing of exterior walls ��13 q ,-
Insulation R value of exterior walls 13
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) 1
Glazing SHGC /
Glazing U-Factor
R value of ductwork iv
A/C SEER rating
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: Plan 2276 Lot 14
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 12/02/03
DATE OF PLANS: Oct 03
PROJECT INFORMATION:
309 Sapphire Dr.
College Station, Texas 77845
COMPANY INFORMATION:
ELH-Elegant Living Homes, Inc.
P. O. Box 7063
Bryan, Texas 77845
NOTES:
Call Bill when ready 229-2045 or
Cindy 777-0703 or
Office 823-0638
COMPLIANCE: Passes
Maximum UA = 564
Your Home = 405
28.2% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Raised or Energy Truss
Exterior Wall 1: Wood Frame, 16" o.c.
Window: 3070: Other
Window: 3060: Other
Window: 6020: Other
Window: 3050: Other
Window: 2050: Other
Window: 3080: Other
Window: 3070: Other
Window: 2860: Other
Window: 4040: Other
Window: 1060: Other
Door: 3/0: Solid
Door: 2/8: Solid
Air Conditioner 1: Electric Central Air, 12 SEER
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
2214
0.0
30.0
69
62
19.0
0.0
3
2148
13.0
0.0
147
42
0.600
25
36
0.600
22
12
0.600
7
45
0.600
27
10
0.600
6
48
0.600
29
42
0.600
25
32
0.600
19
16
0.600
10
12
0.600
7
20
0.170
3
36
0.170
6
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been
designed to meet the 0 E C r e in M Ccheck Version 3.2 Release lb.
Builder/Designer : Date
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 12/02/03
TITLE: Plan 2276 Lot 14
Bldg.
Dept.
Use
Ceilings:
[ ] I 1.
Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
I
Comments: Select the ceiling type and enter its dimensions directly into the grid.
[ ] I 2.
Ceiling 2: Raised or Energy Truss, R-19.0 cavity insulation
I
Comments:
I
Insulation must achieve full height over the plate lines of exterior walls.
I Above -Grade Walls:
[ ] I 1.
Exterior Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments: Select the exterior wall type and enter its dimensions directly into the grid.
Windows:
[ ] I 1.
Window: 3070: Other, U-factor: 0.600
I
For windows without labeled U-factors, describe features:
I
# Panes Frame Type Thermal Break? [ ] Yes [
] No
I
Comments: Y x T Window
[ ] I 2.
Window: 3060: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
I
# Panes Frame Type Thermal Break? [ ] Yes [
] No
I
Comments: Y x 6' Window
[ ] I 3.
Window: 6020: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
I
Comments: 6' x 2' Eyebrow
[ ] I 4.
Window: 3050: Other, U-factor: 0.600
I
For windows without labeled U-factors, describe features:
I
# Panes Frame Type Thermal Break? [ ] Yes [
] No
I
Comments: Y x 5' Window
[ ] I 5.
Window: 2050: Other, U-factor: 0.600
I
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments: TX 5"
[ ] 6.
Window: 3080: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
I
# Panes Frame Type Thermal Break? [ ] Yes [
] No
I
Comments: Y x 8' Window
[ ] I 7.
Window: 3070: Other, U-factor: 0.600
I
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments: Y x T Window
[ ] 8.
Window: 2860: Other, U-factor: 0.600
I
For windows without labeled U-factors, describe features:
I
4 Panes Frame Type Thermal Break? [ ] Yes [
] No
•
Comments: 2'8" x 6' Window
Window: 4040: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
Comments: 4'x 4' OBSC SG
Window: 1060: Other, U-factor: 0.600
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [
Comments: 1' x 6' Window
Doors:
1. Door: 3/0: Solid, U-factor: 0.170
Comments: Y x 6' 8" Fiberglass Door
2. Door: 2/8: Solid, U-factor: 0.170
Comments: 2'8" x 6'8" Door
Heating and Cooling Equipment:
1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
11
]Yes[ ] No
]Yes[ ] No
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
CirculatinpMains
and Runouts
Temperature ( F)
Up to 1 „
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
� T�.�yP -�L�
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)