HomeMy WebLinkAboutRES2003-03568 1406 ELKTON CT BUILDING PERMITTEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
101 T9XAS AV0443
COLLEGE STATION., -TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------------------------------------------
Application Number . . . . . 03-00003674 Date 12/10/03
Property Address . . . . . . 1406 ELKTON CT
Property ID . . 569500-0933-0200 �Sb�
Application description . . . TEMP POLE
Subdivision Name . . . . . . SHENANDOAH PH 9
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . SS
Permit Fee . . . . 20.00
Issue Date . . . . 12/10/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Other Fee Total 45.00 45.00 .00 .00
Grand Total 65.00 65.00 .00 .00
------------------------------------------------- z -------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
City of College Station
WORK REQUEST PAGE 1
REQ/JOB: WF0479992 / 001 PROJECT: REQUEST DATE: 12/15/03
PRINT DATE:-_ .12/15/03 ~
CREW: PRINT TIME:' 14:44:26' "
LOCATION: 1406 ELKTON CT SCHEDULE
START:DATES 12/15/03
77845 COMPLETION: 12/15/03--:
GEN. LOC: COLLEGE STATION LOC ID: 198890
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE
TEMP POLE PASSED
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code : SET UP NEW UTILITY ACCT SET .....�,
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
------------------------------------------
------------------------------------------
PREPARED 4/21/05, 11:59:00 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/21/05
------------------------------------------------------------------------------------------------
ADDRESS . : 1406 ELKTON CT SUBDIV: SHENANDOAH PH 9
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER PHONE
PARCEL 569500-0933-0200
APPL NU;11.3ER: 03-00003568 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/22/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/22/03 AP 12/19/2003 03:58 PM SSTANLEY
Slab Ground Installed
Strings On Setbacks O.K.
B115 01 2/04/04 DS BLDG, FRAMING TIME: 17:00
2/04/04 AP 02/03/2004 04:01 PM SSMITH
B130 01 2/06/04 DS BLDG, INSULATION TIME: 17:00
2/06/04 AP 02/06/2004 11:48 AM SSTANLEY
B125 01 4/21/t5 BI BLDG, FINAL TIME: 17:00
1 5 Z T/S: 04/21/2005 10:45 AM GLSOUTH-----------------------
---------- - ---------- COMMENTS AND NOTES--------------------------------------
1��r
P,� J
Cit of Colle e Station
y
WOR QUEST
PAGE
1
RE JOBFol
Q/ :
WF0477228 / PROJECT:
RE UEST DATE:
12 02 03
PRINT DATE:
.12/02/03
CREW:
PRINT TIME:
16:40:37
SCHEDULE
DATES
LOCATION:
1406 ELKTON CT
03
77845
COMPLETION:
12/02/03
GEN. LOC:
COLLEGE STATION LOC ID:
198890
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
ED FROEHLING ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MRODGERS AUTH: MRODGERS WORK
TYPE:
ROUTINE
3/4"WTR,
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
4"SWR
3/4"WTR,
4"SWR
Category
code CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department:
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
OT-CUSTOMER SERVICE
BUILDING PERMIT
4CITY OF COLLEGE STATION,*,
�M "'I1'�'�►EXn -AVE -..w ...*,
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003568 Date 12/02/03
Property Address . . . . . . 1406 ELKTON CT
Property ID . . 569500-0933-0200
R# . . . . . . . . . . . . . R*****
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SHENANDOAH PH 9
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 135894
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2059.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . SS
Permit Fee . . . . 568.00 Plan Check Fee .00
Issue Date . . . . 12/02/03 Valuation . . . . 135894
Expiration Date . . 5/31/04
Qty Unit Charge Per Extension
BASE FEE 460.00
36.00 3.0000 THOU BLDG, VAL 100001-500000 108.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
---------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION .
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003568
Page 2
Date 12/02/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
BUILDING DEPT REPRESENTATI�VE:
APPLICANT:/_—
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00003568
Date
12/02/03
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
CITY INSTALL
350.00
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
568.00
568.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1318.00
1318.00
.00
.00
-
13 APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE 2A_
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: 140(1 Rk l 111 l C o f+
LOT _-� C ✓BLOCK %�13
BUSINESS/OWNER NAME:
Fw Office Use Only
DATE:
APPLICATION tt D -
TEMP POLE #
SUBDIVISION ��'1� 1 �Gl )1Gt C,�GZ t 1 SEC/PH
PHONE:
CONTRACTOR/HOMEOWNER: fp f4oEALw4 Sou,DER IA.)c PHONE: 716'8Z66
CONTRACTOR ADDRESS: 39e7 /414i1 Lo,veSD1r14- 9PAD
ELECTRICIAN: 4 r-(� eGGGT2r �-
HVAC: 1-G /N.yd VhT� V� SE/LVl�E
PLUMBER: T/LI PEE "9 ' Pl-U 81A14
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req )
DESCRIPTION OF WORK:
STRUCTURE USE: 41,V61.E f'41-711.Y R.E51P4414
HOMEOWNER ASSOC IAT I ON/ARC H ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ A/A
VALUATION: $ � � J, 9j94. 0U '° TOTAL AREA: �ty HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
RI�SEWER TAP: C INTERIOR WALL TYPE:
SIZE
'WATER TAP: N 1 EXTERIOR WALL TYPE:
SIZE
❑ OTHER TAP: FOUNDATION TYPE:
SIZE
❑ TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE F-1 DOUBLE EfT' TRIPLE
bYl G1I_-
`�l (Vold r a
ATTACHED L_7�-j DETACHED CARPORT a
SIGNATURE OF APPLICANT: Z..�,��
Official Use Only __
ents:
R Q 101103 YES r NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 11 7 /
Insulation R value of exterior walls 0, . -� /
Insulation R value of ceiling I (flat areas) �•30
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC , 4 b ./
Glazing U-Factor .61
R value of ductwork 2 • ,
A/C SEER rating j C S(L /
E
U
REScheck Compliance Certificate
2000 IECC
RES check Software Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\LT20BK33.rck
TITLE: LOT 20, BLOCK 33
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 10/ 17/03
DATE OF PLANS: NOVEMBER 1, 2002
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 634
Your Home UA = 567
10.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Front
Projection factor: 0.18
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Projection factor: 0.18
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
2059
30.0
0.0
72
430
15.0
0.0
26
60
0.640 38
38
490 15.0 0.0
66
403 15.0 0.0
72
18
0.800 30
33
0.640 42
24
0.640 46
0.580 10
SHGC: 0.78
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.81
Wall 4: Wood Frame, 16" o.c. 398 15.0 0.0
Window 4: Metal Frame:Double Pane with Low-E 27
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated 192 0.0
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 10 SEER
29
0.640 17
200
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RESchecklnspection Checklist.
Builder/Designer �1 6 i Date 7k -
i
DKToN C>vu2T
50' R. a w.. — 17' Anw"ent
VOL 4671. Pg 157
Bock of Cura�
- - N411ZU I) E - LPZ-.r�, I '<,,
5' P.U.E. — -- — F
N N N
r.._.._. __. F- -.._
7.6' AFT tl'1 7.7
`1 1 I
I � I
I �
I
I I
proposed
s Residence
� Scab. 1' 20'
i — I
7.5
LA
Nov or Fame J"y
Now or Fewly
Vol. 29", Pg. 201 I �` 7,7'w Edward FrNJnq
`� _ I Vol. 206. Pg. 201
+� I
� a � Lot
� I Sheiiondovh f'ho�s+e I s�
I I I I
I I I I
Nair.
Z"ng Ordimnov +1 &%
—..J L.. -r - -— .—..J L..—.._
� 0' IP.U.E. — --
Vol. 4954. i. 155
Bock of Cub _ — --
co' R.QW. N is, Pamment
Vol 4671, Pg. 158
Af(CCLU/QEENG/NEER/NG, /NC• 1408W000tMO -Drive, Su/to A97• Co//sge S&Iion, Tams 77B4s•/979/693-38.70
wLh &Qe-