HomeMy WebLinkAboutRES2003-03567 1454 FINCASTLE LOOP BUILDING PERMITPREPARED 3/23/04, 7:58:52 INSPECTION TICKET PAGE 9 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/23/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1454 FINCASTLE LOOP SUBDIV: SHENANDOAH PH 9 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE : PARCEL . . 569500-0932-0280 APPL NUMBER: 03-00003567 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/16/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 12/16/03 AP 12/16/2003 10:05 AM GCARRILLO ' Slab Ground Installed Strings On Setbacks O.K. B115 01 2/05/04 OC BLDG, FRAMING TIME: 17:00 2/05/04 AP 02/05/2004 09:04 AM MALFORD B�30101 2/06/04 DS BLDG, INSULATION TIME: 17:00 2/06/04 AP 02/06/2004 11:48 AM SSTANLEY BI-25 01 3/23/04 BI BLDG, FINAL TIME: 17:00 03/22/2004 02:47 PM SSTANLEY ---------------------------------- COMMENTS AND NOTES -------------------------------------- a r-, TEMPORARY POLE PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003675 Date 12/10/03 Property Address . . . . . . 1454 FINCASTLE LOOP Property ID 569500-0932-0280 R # . . . . . . . R***** Be 05 Application description . . . TEMP POLE Subdivision Name . . . . . . SHENANDOAH PH 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 12/10/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 BUILDING DEPT REPRESENTATIVE: APPLICANT: / � % /��—; Credited Due -------------------- .00 .00 .00 .00 .00 .00 PAGE 1 City of Collegqe St=tion WORK#QUEST 7 REQ/JOB: WF0477237 / 001 PROJECT: REQUEST DATE: 12/02/03 PRINT DATE: 12/02/03 CREW: PRINT TIME: 16:43:16 SCHEDULE DATES LOCATION: 1454 FINCASTLE LOOP START: 12/02/03 77845 COMPLETION: 12/02/03 GEN. LOC: COLLEGE STATION LOC ID: 198848 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, 4"SWR 3/4"WTR, 4"SWR Category code Task code• Facility ID Assigned Department: CS -CUSTOMER SERVICES SET UP NEW UTILITY ACCT OT-CUSTOMER SERVICE CSCS SET - B]U I.LD IjjT.Q_ UEMZZ-1 • CITY OF COLLEGE STATION* 1101 TEXAS AVE 1 COLLEGE STATION, TX 77840 • PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003567 Date 12/02/03 Property Address . . . . . . 1454 FINCASTLE LOOP Property ID . . . . . . . . . 569500-0932-0280 R # . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 137544 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2084.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 574.00 Plan Check Fee .00 Issue Date . . . . 12/02/03 Valuation . . . . 137544 Expiration Date . . 5/31/04 Qty Unit Charge Per Extension BASE FEE 460.00 38.00 3.0000 THOU BLDG, VAL 100001-500000 114.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT - -------------------------------------------------- ------------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: �— BUILDING PERMIT CITY OF COLLEGE STATION• 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003567 Page 2 Date 12/02/03 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ------------------------------------------------------------ --------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INST L 350.00 ------------------------------------------------------ --- ----------------- BUILDING DEPT REPRREESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIO4 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003567 Date 12/02/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 574.00 574.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1324.00 1324.00 .00 .00 BUILDING DEPT REPRREES-ENTATIVE: APPLICANT: a0 ESL APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LO,ICATION: I` LOT BLOCK For Offl— Use Only DATE:L - APPLICATION # TEMP POLE # SUBDIVISION .. ��O( V) SEC/PH�_ BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: fq> aofliuo4 go1LDER IA.)6 PHONE: 776 -8Ui5 r CONTRACTOR ADDRESS: 3887 /414a L o.VESDi'rE Rortb ELECTRICIAN: Q f-(3 J51_06TR-i c-. PLUMBER: T/Li P441 "9 ' }0LUM81A14 HVAC: �-G 1NNoV/4T/Vo 6&zyGE GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: 5/,t�4cE fMit-Y R ES/OENG HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EABPRJ VALUATION: $ I.,� / I r5lA ( `` 0 _ TOTAL AREA: HEATED AREA: r (Cost of Cabor and Materials) EJI'P'UBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: -( SIZE SIZE SIZE SINGLE a ATTACHED INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE fff` DETACHED SIGNATURE OF APPLICANT: Official Use Only N W0.11 �3 nE ments; orNO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) JZ•30 J Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC , 4 D / Glazing U-Factor .61 R value of ductwork A/C SEER rating 2.0 Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC RES check Software Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\2082RL.rck TITLE: 2082 RAVENSTONE LOOP CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/23/03 DATE OF PLANS: JUNE 17, 2003 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 661 Your Home UA = 572 13.5% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.38 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2084 30.0 0.0 73 Wall 1: Wood Frame, 16" o.c. 418 15.0 0.0 26 Window 1: Metal Frame:Double Pane with Low-E 32 0.600 19 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Front Projection factor: 0.19 Window 5: Metal Frame:Double Pane with Low-E 16 0.600 10 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Front Projection factor: 0.85 Door 1: Solid 38 0.400 15 Wall 2: Wood Frame, 16" o.c. 453 15.0 0.0 33 Window 2: Metal Frame:Double Pane with Low-E 28 0.600 17 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Wall 3: Wood Frame, 16" o.c. 418 15.0 0.0 22 Window 3: Metal Frame:Double Pane with Low-E 72 0.600 43 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.23 Window 6: Metal Frame:Double Pane with Low-E 48 0.600 29 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 1.15 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 453 15.0 0.0 32 Window 4: Metal Frame:Double Pane with Low-E 36 0.600 22 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 212 0.0 221 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer 141,-- Date 2 3 /O U1I[.I/LUVU AUO U,U7 I'MI 010 U00 GUOY QIL%AUIU DlIbIlIVU11116 111L, yy" 1'1UGllllll6, LUMdl %VU'k/UVI rjNGA4-rLE LOOP ao' Row. - sr pomr wt I" Vr Cr-, — — -5' P.U.E. n N n a ^� I I Scales 1" 20' I Resldence j I lot Z7 Lot Edwwd noI I Nw or FormRrr*p Vol. 2956. ft 201 - ; E4*4rd mohong 1 v 1 Lot B*k* I Z I k�r,y t I ii�Ma statim ZWrq oranwwo }leas _..T..J L - - -- ---.._..._..�.._..J jL-T 10' P.U.E. - — -g' sawdt SWk of Curb M' Aaig - .V' Pbrwnwt 01-eW7Td" W 4871, AV. IM A&CUIREENO/NEER/N<9 INC- MAW O zoocrezeI Orin, Said A97 • COA-ge symon, TOWS AIIr"s. /97l� 693-.?B3B U)c�G\n S sae. SXoa(-k S