HomeMy WebLinkAboutRES2003-03566 1407 FINCASTLE LOOP BUILDING PERMITPREPARED 4/08/04, 7:51:24 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/08/04
------------------------------------------------------------------------------------------------
ADDRESS . : 1407 FINCASTLE LOOP SUBDIV: SHENANDOAH PH 9
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 569500-0933-0040
APPL NUMBER: 03-00003566 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/29/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
12/29/03 AP 12/29/2003 10:59 AM GCARRILLO
setback strings pulled
slab ground both sides
Ba 2/17/04 DS BLDG, FRAMING TIME: 17:00
2/24/04 AP 02/17/2004 08:42 AM SSTANLEY
B130 01 3/02/04 TB BLDG, INSULATION TIME: 17:00
3/02/04 AP 03/01/2004 12:23 PM SSTANLEY
B125 01 4/0$/04 BI BLDG, FINAL TIME: 17:00
04/08/2004 07:51 AM MALFORD
-------------------------------------- COMMENTS AND NOTES ---------------------
i
City of Colleg S tion
W QUEST
-._ ..... _ PAGE 1
REQ/JOB:
WF0477231 / O1 PROJECT:
REQUEST DATE:
12/02/03
PRINT DATE:
12/02/03
CREW:
PRINT TIME:
16:41:10
SCHEDULE
LOCATION:
1407 FINCASTLE LOOP
STTART:DATES
12/02/03
77845
COMPLETION:
12/02/03
GEN. LOC:
COLLEGE STATION LOC ID: 198858
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
ED FROEHLING ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MRODGERS AUTH: MRODGERS WORK TYPE:
ROUTINE
3/4"WTR,
4"SWR
3/4"WTR,
4"SWR
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department: OT-CUSTOMER SERVICE
� BU.ZLDING PERMIT
=ay�,Q_T )L .OFFC I,, FGE ,STA'I I '
R 1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00003566 Date 12/02/03
Property Address . . .
. . . 1407 FINCASTLE LOOP
Property ID
. . 569500-0933-0040
R# . . . . . . . . . .
. . . R*****
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . SHENANDOAH PH 9
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . SINGLE FAMILY RESIDENTIAL
Application valuation .
. . . 138006
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
------ Structure Information
SINGLE FAMILY -----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 2091.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . SS
Permit Fee . . . .
577.00 Plan Check Fee .00
Issue Date . . . .
12/02/03 Valuation . . . . 138006
Expiration Date . .
5/31/04
Qty Unit Charge Per Extension
BASE FEE 460.00
39.00 3.0000 THOU BLDG, VAL 100001-500000 117.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
• CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Page 2
Application Number . . . . . 03-00003566 Date 12/02/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOO IN
BUILDING DEPT REPRESENTATIVE:
APPLICANT: _ ��
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00003566 Date 12/02/03
----------------------------------------------------------------------------
Special Notes and Comments
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged
Permit Fee Total 577.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1327.00
Paid Credited Due
------------------------------
577.00 .00 .00
.00 .00 .00
750.00 .00 .00
1327.00 .00 .00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
do
APP• ATION FOR BUILDING
PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
For OIRce Use Onry
DATE Ia- )-o3
APPLICATION #
TEMP POLE # ,
ADDRESS/,L/OCATION:_1`' J finr,aeii-lc, Loop
LOT �_ BLOCK ✓SUBDIVISION Lj� C n ��� QGL Y l SEC/PH
BUSINESS/OWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER: f-APHONE:
CONTRACTOR ADDRESS: 1L \Q�(`1 t'0y)"V:V0w» = S6Uab CUhf)Vi. Tl �4Cj
ELECTRICIAN: �{' �j ,' eCi"1 y� �, PLUMBER14ft "Co" Ouyvkhi na
HVAC:, Ci Mn a-b( (P' GOOD CENTS (Residential only): t-4 N
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) N NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE: SIyw\p �am' kkq fte' 1 r r u
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS)/PROJECT REGISTRATION# EABPRJ
VALUATION: $ I b7-)oO U ✓ TOTAL AREA:r�� HEATED AREA:,.���
(Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS: ` rt
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP: 11
INTERIOR WALL TYPE Q C,bn� CAL_
SIZE
WATER TAP: 3/�{ I EXTERIOR WALL TYPE: 1/1 (J�L
SIZE
❑ OTHER TAP: FOUNDATION TYPE: 61 a,b 0y)f2" j�f'
SIZE
TEMP POLE ROOF TYPE: C '3r-), I 1 0 t�I '� 1 N�A Ti
GARAGE TYPE: SINGLE DOUBLE 4 TRIPLE � `/�"_�` ` ``/
ATTACHED DETACHED F7 CARPORT
SIGNATURE OF APPLICANT:
♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦
Official Use Only
Cis �I01'o3 ents:
YES rN0
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
R-U
1 "
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release I
Data filename: C:\Program Files\Check\REScheck\l 106CC.rck
TITLE: LOT 4BLK 33
CITY: College Station
STATE:, Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/02/03
DATE OF PLANS: DECEMBER 5, 2002
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 690
Your Home UA = 622
9.9% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2091
30.0
0.0
73
Wall 1: Wood Frame, 16" o.c.
147
13.0
0.0
8
Window 1: Metal Frame:Double Pane with Low-E
46
0.640
29
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Front
Projection factor: 0.14
Wall 2: Wood Frame, 16" o.c.
64
13.0
0.0
2
Window 2: Metal Frame:Double Pane with Low-E
40
0.640
26
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
36
13.0
0.0
3
Wall 4: Wood Frame, 16" o.c.
92
13.0
0.0
6
Window 4: Metal Frame:Double Pane with Low-E
16
0.640
10
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Front
Projection factor: 0.69
Wall 5: Wood Frame, 16" o.c.
44
13.0
0.0
2
•
Door 1: Solid
20
0.400
8
Wall 6: Wood Frame, 16" o.c.
135
13.0 0.0
11
Wall 7: Wood Frame, 16" o.c.
158
13.0 0.0
13
Wall 8: Wood Frame, 16" o.c.
245
13.0 0.0
17
Window 4: Metal Frame:Double Pane with Low-E
40
0.640
26
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 9: Wood Frame, 16" o.c.
168
13.0 0.0
13
Window 5: Metal Frame:Double Pane with Low-E
10
0.640
6
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Wall 10: Wood Frame, 16" o.c.
45
13.0 0.0
4
Wall 11: Wood Frame, 16" o.c.
120
13.0 0.0
6
Window 6: Metal Frame:Double Pane with Low-E
48
0.640
31
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 1.00
Wall 12: Wood Frame, 16" o.c.
45
13.0 0.0
2
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 180 deg. from North; Comp. orient.: Left Side
Projection factor: 0.81
Wall 13: Wood Frame, 16" o.c.
136
13.0 0.0
7
Window 7: Metal Frame:Double Pane with Low-E
56
0.640
36
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 0.12
Wall 14: Wood Frame, 16" o.c.
451
13.0 0.0
35
Window 8: Metal Frame:Double Pane with Low-E
27
0.640
17
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Right Side
Projection factor: 0.23
Floor l: Slab-On-Grade:Unheated
212
0.0
221
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described
here is consistent with the building
plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec/ and to comply with the mandatory requirements listed in
the RES check Inspection Checklist.
Builder/Designer .Jft' !,
Date Z
FINCPvS'TLE-- LOOP
50' R,O.W. 27' Pu mat
P7• 140
9t10♦( O� CLrb
7.W 49.b' ..7.W
� i
ILA
m
I stole: 1' — 20'
Proposed
Residence
Now or Funnerty Now or rormarty
Edward Fro `U I E0 oM Frog nqq
Vol. 3162. Pg. 199 I I Vol. 3162. PQ. 109
Lot L} Bloch L
i `ex,anda�h Pry 9
70
�i
I
_ I
'�' S Nair Sldq. S*%*Ck Unw
. Ss W Cqy Of C "" station
lss Zoning Ordsono. #ISM
-j I- -
i.
in
20' P.U.E
W - &100 - Now or Formerly I Now or F9rn" I Now or Fonrmly
Edward rm.ah np Edward RoNfpng Edwinl Frwhl"
Vol. 3162, Pg 164 Vol. 3162, Py. 199 Vol. .3162. Pg. 199
3l—YayO.%.d g
W--CU REENG/NEER1*G, INC • &W9 WbodcM&1fOrivv S&IAO M.? • ColJPge S&A14 Tex.9s 718,dg • j479/ 993- &M