HomeMy WebLinkAboutRES2003-03564 1432 FINCASTLE LOOP BUILDING PERMITPREPARED 9/23/04, 7:57:21 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/23/04
-------------------------------------------------------------------------------------------------
ADDRESS . : 1432 FINCASTLE LOOP SUBDIV: SHENANDOAH PH 9
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 569500-0932-0170
APPL NUMBER: 03-00003564 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/10/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
12/10/03 AP 12/10/2003 11:55 AM SSTANLEY
Strings On Setbacks O.K.
Slab Ground Installed
$i:15.-'A1 2/24/04 DP BLDG, FRAMING TIME: 17:00
2/24/04 AP 02/23/2004 03:02 PM GCARRILLO
Joist Hangers Needed
B1�0 01 2/27/04 DP BLDG, INSULATION TIME: 17:00
2/27/04 AP 02/26/2004 03:03 PM GCARRILLO
B 01 9/23/04 BI BLDG, FINAL TIME: 17:00
09/22/2004 03:56 PM SSTANLEY
------------------------------- COMMENTS AND NOTES -----------------------------
1A
0A ,, Aw� �
CITY OF COLLEGE STATION
WORK R96UEST f PAGE 1
REQ/JOB: WF0483554 / 001 PROJECT: REQUEST DDAPRINT TE: 12/30/03
CREW: PRINT TIME: 11:50:52
SCHEDULE DATES
LOCATION: 1432 FINCASTLE LOOP 03
77845 COMPLETION: 12/30/03
GEN. LOC: COLLEGE STATION LOC ID: 198826
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code
Task code:
Facility ID
Assigned Department:
CS -CUSTOMER SERVICES CSCS
SET UP NEW UTILITY ACCT SET
OT-CUSTOMER SERVICE
City
of Collegqe
WORK
St tion
QUEST y
46
PAGE
1
REQ/JOB:
WF0477232
/001 PROJECT:
REQUEST DATE:
12/02/03
PRINT DATE:
12/02/03
CREW:
PRINT TIME:
16:41:30
SCHEDULE
LOCATION:
1432 FINCASTLE LOOP
STTART:DATES
12/02/03
77845
COMPLETION:
12/02/03
GEN. LOC:
COLLEGE
STATION LOC ID:
198826
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
ED FROEHLING
ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MRODGERS
AUTH: MRODGERS WORK
TYPE:
ROUTINE
3/4"WTR,
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
411SWR
3/4"WTR,
411SWR
Category
code
CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department:
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
OT-CUSTOMER SERVICE
_BUILDING PERMIT
S"I''T' I ZSN�
110 TEXA 'AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003564 Date 12/02/03
Property Address . . . . . . 1432 FINCASTLE LOOP
Property ID . . 569500-0932-0170
R # . . . . . . . . . . . . . R*****
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SHENANDOAH PH 9
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 144804
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2194.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 5.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . SS
Permit Fee . . . . 595.00 Plan Check Fee .00
Issue Date . . . . 12/02/03 Valuation . . . . 144804
Expiration Date . . 5/31/04
Qty Unit Charge Per Extension
BASE FEE 460.00
45.00 3.0000 THOU BLDG, VAL 100001-500000 135.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
------------------------------------------------------ZZ
--------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION•
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00003564 Date 12/02/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
BUILDING DEPT REPRESENTAT VE:
APPLICANT: / - �_
BUILDING PERMIT
CITY OF COLLEGE STATION*
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00003564
Date
12/02/03
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary
Charged
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
----------
595.00
595.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1345.00
1345.00
.00
.00
-
For Or— Use Only
13 APPLICATION FOR BUILDING PERMIT DATE: /)� I- 03
CITY OF COLLEGE STATION APPLICATION #
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 a_v� TEMP POLE #
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: 1 65L Vi n ca 6f ie- Uoc p
LOT I� BLOCK �" SUBDIVISION _' h A I(,l,�dO� I 1 SEC/PH
BUSINESS/OWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER: f-p EgQrA f• 4 SoILc DES /A.)6 PHONE: 776 -8Z66
CONTRACTOR ADDRESS: 39B 7 141414 g!phb
ELECTRICIAN: Q r-(3 25Z4C rR-t c_ PLUMBER: TiLIYcE ",S
HVAC: 5'G 1NNd VATl VO S62VlG4- GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE: S/R4r_0 0,4/n/,L y fL�S/06iYc
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ %V IA
VALUATION: $ 14+1 TOTAL AREA: HEATED AREA: 2I
(Cost of Labor and Materials)
Ell'P-UBLIC SEWER
SEPTIC/TREATMENT SYSTEM
PI�SEWER TAP: -( "
SIZE
WATER TAP: �1,4
SIZE
OTHER TAP:
DILL
TEMP POLE
GARAGE TYPE: SINGLE a
ATTACHED
NUMBER OF BEDROOMS: 15
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE: z3yx6tYOC,K
EXTERIOR WALL TYPE: Y2 16K
FOUNDATION TYPE: �1a12no
ROOF TYPE: CU 1 VVJI VI rLl IJI�
DOUBLE Ef— TRIPLE
DETACHED F-1 CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
ments:
la Ol 03VZO or NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls %a
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) �•30
Insulation R value of ceiling 2 (vaulted areas/no attic) N /�
Glazing SHGC q4 D
Glazing U-Factor 61 -�
R value of ductwork /Z • C
A/C SEER rating b
c �
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
RES check Software Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\LT7BK33.rck
TITLE: LOT 7 BLOCK 33
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: I 1 /07/03
DATE OF PLANS: JULY 14, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 678
Your Home UA = 569
16.1% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter
R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2252
30.0
0.0
79
Wall 1: Wood Frame, 16" o.c.
396
15.0
0.0
22
Window 1: Metal Frame:Double Pane with Low-E
73
0.600
44
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
484
15.0
0.0
35
Window 2: Metal Frame:Double Pane with Low-E
31
0.600
19
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
396
15.0
0.0
24
Window 3: Metal Frame:Double Pane with Low-E
68
0.600
41
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass
18
0.580
10
SHGC: 0.78
Bldg. faces 315 deg. from North; Comp. orient.: Back
Projection factor: 1.02
Wall 4: Wood Frame, 16" o.c. 484 15.0 0.0 35
Window 4: Metal Frame:Double Pane with Low-E 27 0.600 16
SHGC: 0.40
Bldg. faces 315 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated 220 0.0 229
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec,� and to comply with the mandatory requirements listed in
the RES check Inspection Checklist.I
Builder/Designer _ Date u
.tWACA sAacks
�I �