HomeMy WebLinkAboutRES2003-03563 1414 ELKTON CT BUILDING PERMITREPARED
3/23/04,
7:58:52
INSPECTION TICKET PAGE 8
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 3/23/04
------------------------------------------------------------------------------------------------
ADDRESS
. : 1414 ELKTON CT
SUBDIV: SHENANDOAH PH 9
CONTRACTOR
ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER .
.
PHONE
PARCEL .
. 569500-0933-0160
APPL NUMBER:
03-00003563 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
12/30/03
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
12/30/03
AP
12/30/2003 10:46 AM GCARRILLO
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
1/29/04
TB
BLDG, FRAMING TIME: 17:00
1/29/04
DP
01/28/2004 03:05 PM GCARRILLO
Not Ready For Inspection
t
Sheetrock Fireplace Chase, Firestopping
Joist Hangers Needed
Double Ceiling Joist O Attic Opening
NO ATTIC ACCESS
FLOATING JOIST IN GARAGE
BLOCK SEAM IN WINDBRACE - FRONT DOOR
HOOK UP EXHAUST FANS
B111
02
2/02/04
DS
BLDG, FRAMING TIME: 17:00
2/03/04
AP
02/02/2004 10:48 AM MALFORD
B130 01
2/09/04
DP
BLDG, INSULATION TIME: 17:00
2/09/04
AP
02/09/2004 08:39 AM GCARRILLO
B121 0�
3/23/04
BLDG, FINAL TIME: 17:00
3(j,1
03/22/2004 02:47 PM SSTANLEY
-------------------------------------- COMMENTS AND NOTES---------------
CITY OF COLLEGE STATION
WORKWQUEST
REQ/JOB: WF0483558 / 001
CREW:
PAGE 1
PROJECT: REQUE03
PRINT SDATE: 12T DATE: /30/03
PRINT TIME: 11:56:28
LOCATION: 1414 ELKTON CT SCHEDULE
STTART:DATES 12/30/03
77845 COMPLETION: 12/30/03
GEN. LOC: COLLEGE STATION LOC ID: 198882
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
TEMP POLE PASSED
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TEMP POLE PASSED
Category code
Task code:
Facility ID
Assigned Department:
CS -CUSTOMER SERVICES CSCS
SET UP NEW UTILITY ACCT SET
OT-CUSTOMER SERVICE
City
of Collegqe
Station
WORQUEST
PAGE
1
REQ/JOB:
WF0477236
/ 001 PROJECT:
REQUEST DATE:
12/02/0:5
PRINT DATE:
12/02/03
CREW:
PRINT TIME:
16:42:52
SCHEDULE
LOCATION:
1414 ELKTON
CT
STTART:DATES
12/02/03
77845
COMPLETION:
12/02/03
GEN. LOC:
COLLEGE
STATION LOC ID:
198882
REF NBR:
REQ DEPT:
DE -BUILDING
INSPECTION PRIORITY:
NORMAL
REQUESTOR:
ED FROEHLING
ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MRODGERS
AUTH: MRODGERS WORK
TYPE:
ROUTINE
3/41-WTR,
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
411SWR
3/4"WTR,
411SWR
Category
code
CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department:
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
OT-CUSTOMER SERVICE
PERMIT 1
_BUILDING
CITY OF QOL4 GE STATION •
1101 TEXAS AVE
r
COLLEGE STATION, TX 77840
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Application Number
. . . . . 03-00003563 Date 12/02/03
Property Address
. . . . . . 1414 ELKTON CT
Property ID
. . 569500-0933-0160
R# . . . . . . .
. . . . . . R*****
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . . SHENANDOAH PH 9
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 122760
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
------ Structure Information SINGLE FAMILY -----
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1860.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. SS
Permit Fee . . .
. 529.00 Plan Check Fee .00
Issue Date . . .
. 12/02/03 Valuation . . . . 122760
Expiration Date .
. 5/31/04
Qty Unit Charge Per Extension
BASE FEE 460.00
23.00 3.0000 THOU BLDG, VAL 100001-500000 69.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPM NT
BUILDING DEPT REPRESSEN/TATIVE:
APPLICANT:
•BUILDING PERMIT
CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003563
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
Page 2
Date 12/02/03
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CIT T L 350.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:%z
BUILDING PERMIT
CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00003563 Date 12/02/03
----------------------------------------------------------------------------
Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged
Permit Fee Total 529.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1279.00
Paid Credited Due
------------------------------
529.00 .00 .00
.00 .00 .00
750.00 .00 .00
1279.00 .00 .00
-
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
For ON-- Use Orly
DATE: 2 - 0 ) - 3
APPLICATION #
TEMP POLE #
ADDRESS/LOCATION: �A4 F,— ftn Cn6�.uyi I
LOT �� BLOCK _J SUBDIVISION len an6oa ) SEC/PH
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: Fp f"BauvL ggt(,p&1t / IAt)6 PHONE: 7%6'8466
CONTRACTOR ADDRESS: 3987 /414w ge*b
ELECTRICIAN: 44-13 PLUMBER: TiLrN4E "5 ' PI-UMQ/A/6
HVAC: 5'G 1.v.No V/ITI V6 5eAVIc-E GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE: 51,t�4cE f'�Mi�
y 2E5/DEiY�,E
HOMEOWNER ASSOC IATIO N/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE
APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TA,S� PROJECT REGISTRATION# EABPRJ A(IA
VALUATION: $C � -I tu0c �/
TOTAL AREA: A10
i
HEATED AREA: I�S(QD
(Cost of Labor and Materials)
Ell'PUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
j
SEWER TAP: f "
INTERIOR WALL TYPE:
SIZE
WATER TAP: )1,4
EXTERIOR WALL TYPE:
'1(
SIZE
OTHER TAP:
FOUNDATION TYPE:
�Il. o Ok) bY ,1 CU
SIZE
TEMP POLE
ROOF TYPE:
�, ` ��� � Ie,
GARAGE TYPE: SINGLE a
DOUBLE �- TRIPLE
a
ATTACHED �
DETACHED CARPORT
a
SIGNATURE OF APPLICANT: JZ_
Official Use Only
0 a 1b3 ments:
YE or NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 8 ld
Insulation R value of exterior walls /Z. lr� /
Insulation R value of ceiling 1 (flat areas) Q•3o
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
6 �
Glazing U-Factor �f
R value of ductwork
A/C SEER rating
MECcheck Compliance Report
1995 MEC
MECcheck Software Version 3.2 Release lb
TITLE: 1113 TYLER COURT
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/12/03
DATE OF PLANS: FEBRUARY 24, 2003
PROJECT INFORMATION:
SHELTON HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 609
Your Home = 550
9.7% Better Than Code
Permit Number
Checked By/Date
Gross
Glazing
Area or Cavity
Cont. or Door
Perimeter R-Value
R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 1860 30.0
0.0 65
Wall 1: Wood Frame, 16" o.c. 1635 13.0
0.0 111
Window 1: Metal Frame, Double Pane with Low-E 220
0.650 143
Door 1: Solid 38
0.400 15
Door 2: Glass 18
0.890 16
Slab 1: Unheated, 0.0' insul. 192
0.0 200
COMPLIANCE STATEMENT: The proposed building design described here is consistent
with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed
to meet the 1995 MEC requirements in MECcheck Version 3.2 Release lb.
Builder/Designer tj Date
i
'61 _
17
0
NNW
Eiklpn Co04
I Q 4 U �Jm C,;i--