Loading...
HomeMy WebLinkAboutRES2003-03563 1414 ELKTON CT BUILDING PERMITREPARED 3/23/04, 7:58:52 INSPECTION TICKET PAGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/23/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1414 ELKTON CT SUBDIV: SHENANDOAH PH 9 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 569500-0933-0160 APPL NUMBER: 03-00003563 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/30/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 12/30/03 AP 12/30/2003 10:46 AM GCARRILLO Strings On Setbacks O.K. Slab Ground Installed B115 01 1/29/04 TB BLDG, FRAMING TIME: 17:00 1/29/04 DP 01/28/2004 03:05 PM GCARRILLO Not Ready For Inspection t Sheetrock Fireplace Chase, Firestopping Joist Hangers Needed Double Ceiling Joist O Attic Opening NO ATTIC ACCESS FLOATING JOIST IN GARAGE BLOCK SEAM IN WINDBRACE - FRONT DOOR HOOK UP EXHAUST FANS B111 02 2/02/04 DS BLDG, FRAMING TIME: 17:00 2/03/04 AP 02/02/2004 10:48 AM MALFORD B130 01 2/09/04 DP BLDG, INSULATION TIME: 17:00 2/09/04 AP 02/09/2004 08:39 AM GCARRILLO B121 0� 3/23/04 BLDG, FINAL TIME: 17:00 3(j,1 03/22/2004 02:47 PM SSTANLEY -------------------------------------- COMMENTS AND NOTES--------------- CITY OF COLLEGE STATION WORKWQUEST REQ/JOB: WF0483558 / 001 CREW: PAGE 1 PROJECT: REQUE03 PRINT SDATE: 12T DATE: /30/03 PRINT TIME: 11:56:28 LOCATION: 1414 ELKTON CT SCHEDULE STTART:DATES 12/30/03 77845 COMPLETION: 12/30/03 GEN. LOC: COLLEGE STATION LOC ID: 198882 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TEMP POLE PASSED Category code Task code: Facility ID Assigned Department: CS -CUSTOMER SERVICES CSCS SET UP NEW UTILITY ACCT SET OT-CUSTOMER SERVICE City of Collegqe Station WORQUEST PAGE 1 REQ/JOB: WF0477236 / 001 PROJECT: REQUEST DATE: 12/02/0:5 PRINT DATE: 12/02/03 CREW: PRINT TIME: 16:42:52 SCHEDULE LOCATION: 1414 ELKTON CT STTART:DATES 12/02/03 77845 COMPLETION: 12/02/03 GEN. LOC: COLLEGE STATION LOC ID: 198882 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/41-WTR, ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 411SWR 3/4"WTR, 411SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE PERMIT 1 _BUILDING CITY OF QOL4 GE STATION • 1101 TEXAS AVE r COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003563 Date 12/02/03 Property Address . . . . . . 1414 ELKTON CT Property ID . . 569500-0933-0160 R# . . . . . . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 122760 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1860.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 529.00 Plan Check Fee .00 Issue Date . . . . 12/02/03 Valuation . . . . 122760 Expiration Date . . 5/31/04 Qty Unit Charge Per Extension BASE FEE 460.00 23.00 3.0000 THOU BLDG, VAL 100001-500000 69.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPM NT BUILDING DEPT REPRESSEN/TATIVE: APPLICANT: •BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003563 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER Page 2 Date 12/02/03 CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CIT T L 350.00 BUILDING DEPT REPRESENTATIVE: APPLICANT:%z BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003563 Date 12/02/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Permit Fee Total 529.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1279.00 Paid Credited Due ------------------------------ 529.00 .00 .00 .00 .00 .00 750.00 .00 .00 1279.00 .00 .00 - APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US For ON-- Use Orly DATE: 2 - 0 ) - 3 APPLICATION # TEMP POLE # ADDRESS/LOCATION: �A4 F,— ftn Cn6�.uyi I LOT �� BLOCK _J SUBDIVISION len an6oa ) SEC/PH BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: Fp f"BauvL ggt(,p&1t / IAt)6 PHONE: 7%6'8466 CONTRACTOR ADDRESS: 3987 /414w ge*b ELECTRICIAN: 44-13 PLUMBER: TiLrN4E "5 ' PI-UMQ/A/6 HVAC: 5'G 1.v.No V/ITI V6 5eAVIc-E GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: 51,t�4cE f'�Mi� y 2E5/DEiY�,E HOMEOWNER ASSOC IATIO N/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TA,S� PROJECT REGISTRATION# EABPRJ A(IA VALUATION: $C � -I tu0c �/ TOTAL AREA: A10 i HEATED AREA: I�S(QD (Cost of Labor and Materials) Ell'PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: j SEWER TAP: f " INTERIOR WALL TYPE: SIZE WATER TAP: )1,4 EXTERIOR WALL TYPE: '1( SIZE OTHER TAP: FOUNDATION TYPE: �Il. o Ok) bY ,1 CU SIZE TEMP POLE ROOF TYPE: �, ` ��� � Ie, GARAGE TYPE: SINGLE a DOUBLE �- TRIPLE a ATTACHED � DETACHED CARPORT a SIGNATURE OF APPLICANT: JZ_ Official Use Only 0 a 1b3 ments: YE or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 8 ld Insulation R value of exterior walls /Z. lr� / Insulation R value of ceiling 1 (flat areas) Q•3o Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC 6 � Glazing U-Factor �f R value of ductwork A/C SEER rating MECcheck Compliance Report 1995 MEC MECcheck Software Version 3.2 Release lb TITLE: 1113 TYLER COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 03/12/03 DATE OF PLANS: FEBRUARY 24, 2003 PROJECT INFORMATION: SHELTON HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 609 Your Home = 550 9.7% Better Than Code Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1860 30.0 0.0 65 Wall 1: Wood Frame, 16" o.c. 1635 13.0 0.0 111 Window 1: Metal Frame, Double Pane with Low-E 220 0.650 143 Door 1: Solid 38 0.400 15 Door 2: Glass 18 0.890 16 Slab 1: Unheated, 0.0' insul. 192 0.0 200 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in MECcheck Version 3.2 Release lb. Builder/Designer tj Date i '61 _ 17 0 NNW Eiklpn Co04 I Q 4 U �Jm C,;i--