Loading...
HomeMy WebLinkAboutRES2003-03562 1426 FINCASTLE LOOP BUILDING PERMITCity of College Station. 1 1 01 TEXAS AVENUE COLD ATZ.ON—TX 7 7 8 AWA C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 6/30/04 Parcel Number . . . . . 569500-0932-0140 Property Address . . . 1426 FINCASTLE LOOP COLLEGE STATION TX 77845 Subdivision Name . . . SHENANDOAH PH 9 Legal Description . . . SHENANDOAH #9, BLOCK 32, LOT 1 4 Property Zoning . . . . UNKNOWN Owner . . . . . . . . . ED FROEHLING BUILDER INC Contractor . . . . . . ED FROEHLING BUILDERS 979 776-8266 Application number 03-00003562 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved . . . . . . . Building Of f iclial VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 6/30/04, 7:24:33 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/30/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1426 FINCASTLE LOOP SUBDIV: SHENANDOAH PH 9 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 569500-0932-0140 APPL NUMBER: 03-00003562 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/16/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 12/16/03 AP 12/16/2003 10:06 AM GCARRILLO Slab Ground Installed Strings On Setbacks O.K. B115 02 2/05/04 DS BLDG, FRAMING TIME: 17:00 2/06/04 DP 02/05/2004 04:42 PM SSTANLEY Need brace under perlin joint over kitchen. Need full sheet of OSB For wind bracing front bedroom (side of house). Need to block OSB joint right side living room joist hanger garage B115 01 2/06/04 BI BLDG, FRAMING TIME: 17:00 2/05/04 CA 02/05/2004 04:39 PM SSTANLEY B130 01 2/06/04 BI BLDG, INSULATION TIME: 17:00 2/05/04 CA 02/05/2004 04:38 PM MALFORD B115 03 2/09/04 DP BLDG, FRAMING TIME: 17:00 2/09/04 AP 02/09/2004 08:40 AM SSTANLEY B130 02 2/12/04 OC BLDG, INSULATION TIME: 17:00 2/12/04 AP 02/12/2004 10:10 AM SSMITH B125 01 6/30/,04 BI BLDG, FINAL TIME: 17:00 06/29/2004 01:33 PM GCARRILLO -------------------------------------- COMMENTS AND NOTES-------------------------------------- kn -Ac 01 aw*3 City of College St on WORK UEST r PAGE 1 REQ/JOB: WF0477233 / 0.01 PROJECT:REQUEST DATE: 12/02/03 . PRINT DATE: 12/02/03 CREW: PRINT TIME: 16:41:50 SCHEDULE DATES LOCATION: 1426 FINCASTLE LOOP START: 12/02/03 77845 COMPLETION: 12/02/03 GEN. LOC: COLLEGE STATION LOC ID: 198820 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 411SWR 3/4"WTR, 411SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT yt� .CITY Q�,,,Q�OLLEGFy STATION• e 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003562 Date 12/02/03 Property Address . . . . . . 1426 FINCASTLE LOOP Property ID . . 569500-0932-0140 R # . . . . . . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 123288 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1868.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 532.00 Plan Check Fee .00 Issue Date . . . . 12/02/03 Valuation . . . . 123288 Expiration Date . . 5/31/04 Qty Unit Charge Per Extension BASE FEE 460.00 24.00 3.0000 THOU BLDG, VAL 100001-500000 72.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT REPRESENTATIVE: APPLICANT: /�_ •BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003562 Page 2 Date 12/02/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES - BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003562 Date 12/02/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 532.00 532.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1282.00 1282.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: �_ i • • For Office Use Only APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US DATE: APPLICATION # �'e�'•I� TEMP POLE # ADDRESS/LO ATION: 14'2 (p IiOoP LOT BOCK ✓SUBDIVISION C SEC/PH BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: f-p aexat,w4 6vtc,DE0 . 1N6 PHONE: 7%('8U15 CONTRACTOR ADDRESS: 31987 14144 L o,vESOrrE 9MD ELECTRICIAN: 64-(3 61_00T2rC_ PLUMBER: T%Z«'cf "-5 ' h1-yM81A14 HVAC: 5& ly.yd VilTlyo 6elzoGE GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: 5/i &LO f94/n/t-Y fLeS/pAlye9 HOMEOWNER ASSOC IATION/ARC HITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJEQt REGISTRATION# EABPRJ Al�A VALUATION: $ j -/ TOTAL AREA:. HEATED AREA: (Cost of Lab r and Materials) 14 El"PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: ! INTERIOR WALL TYPE: e-41 f L iyu JILt tl-W-ATER TAP: Y6} EXTERIOR WALL TYPE: SIZE ❑ OTHER TAP: FOUNDATION TYPE: SIZE ❑ TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE Efl— TRIPLE a ATTACHED = DETACHED F-1 CARPORT SIGNATURE OF APPLICANT: Official Use Only ments: _i Ia�o1�03 YESorNO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls,,�0 Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) J,•30 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork 2 A/C SEER rating i REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release lb Data filename: C:\Program Files\Check\MECcheck\LT14BK32.rck TITLE: LT14BK32 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/ 17/03 DATE OF PLANS: FEBRUARY 8, 2003 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 604 Your Home UA = 560 7.3% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.23 Door 2: Glass Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1857 30.0 0.0 65 425 13.0 0.0 26 70 0.640 45 38 0.800 30 403 13.0 0.0 32 14 0.640 9 422 13.0 0.0 21 151 0.640 97 18 0.580 10 SHGC: 0.78 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.19 Wall 4: Wood Frame, 16" o.c. 407 13.0 0.0 33 Window 4: Metal Frame:Double Pane with Low-E 2 0.640 1 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Right Side Projection factor: 0.75 Floor 1: Unheated 183 0.0 191 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in the RESchecklnspection Checklist. Builder/Designer_ Z�i �� Date IQ X,O LoT APO ELK ��- 210, Put, — — L — — o 00 Lot 1� �►aK 3� 2 ShC n a-nda��n y9 �G N 44: 33'49" \w U 6 oo, - �i ncaStle. hoop 56' R.a, w. -v 2-7' PagtrntClt '� l�Jat�ti `S'dt Sacks