HomeMy WebLinkAboutRES2003-03561 1455 FINCASTLE LOOP BUILDING PERMITCITY OF COLLEGE STATION • WORK REQUEST PAGE 1 REQ/JOB: WF0483555 / 001 PROJECT: REQUEST DATE: PRINT DATE: 12/30/03 CREW: PRINT TIME: 11:53:35 SCHEDULE DATES LOCATION: 1455 FINCASTLE LOOP 03 77845 COMPLETION: 12/30/03 GEN. LOC: COLLEGE STATION LOC ID: 198910 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE City of Collecre St pion 'PORK QUEST � PAGE 1 REQ/JOB: WF0477234 / 001 PROJECT: REQUEST DTETE� 12/02/PRINT 03 CREW: PRINT TIME: 16:42:11 SCHEDULE DATES LOCATION: 1455 FINCASTLE LOOP 03 77845 COMPLETION: 12/02/03 GEN. LOC: COLLEGE STATION LOC ID: 198910 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3/4"WTR, ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 411SWR 3/4"WTR, 411SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT- CITY OF COLL 6rj, �`' TI T 1 1101 TEXAS AVE COLLEGE STATION, TX 77840 ' PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003561 Date 12/02/03 Property Address . . . . . . 1455 FINCASTLE LOOP Property ID . . 569500-0933-0300 R# . . . . . . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 135894 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2059.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 568.00 Plan Check Fee .00 Issue Date . . . . 12/02/03 Valuation . . . . 135894 Expiration Date . . 5/31/04 Qty Unit Charge Per Extension BASE FEE 460.00 36.00 3.0000 THOU BLDG, VAL 100001-500000 108.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT RE�PRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003561 Page 2 Date 12/02/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR N PRIVATE GARAGES BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003561 Date 12/02/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 568.00 568.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1318.00 1318.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: 0 0 • •1 Fa Obit. Use OMy APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: LOT � BLOCK y ( tUBDIVISION BUSINESS/OWNER NAME: DATE: I C;L APPLICATION # TEMP POLE # PHONE: SEC/PH_ CONTRACTOR/HOMEOWNER: fp aegra(,ty6 guts IA.)6 PHONE: //� •S2-66 CONTRACTOR ADDRESS: 31EB 7 1414AJ L o.yESOrrE 9PAD ELECTRICIAN: 6 4-13 15L.60T2t c— PLUMBER: rl?.IPGf 'S ' P4.0 81A14 HVAC: 5'G 11_,'.N0V.4T1 V6 66fZWGE GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: Sht &L0 A41nil-Y f46.-51D9&e_ HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PR JECT REGISTRAT►ON# EABPRJ %VIA VALUATION: $_I"/ M4 00 TOTAL AREA: HEATED AREA: U5C1 (Cost of Labor and Materials) Ell'P-UBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: `( „ SIZE 'WATER TAP: Y4 1 SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE EXTERIOR WALL TYPE: '�?11 r C ty-C) c, k- p-)Y I L/r— ❑ OTHER TAP: FOUNDATION TYPE: SIZE 1 Q TEMP POLE ROOF TYPE: �,� 1 j�j'� 9', I i1 GARAGE TYPE: SINGLE a DOUBLE ff�` TRIPLE ATTACHED [�fr DETACHED F7 CARPORT SIGNATURE OF APPLICANT: ��r� XIX� ' Official Use Only ents: L �S Ia 01 IO YES r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 13.0 Zr,/ Insulation R value of exterior walls lr� "/ / Insulation R value of ceiling I (flat areas) .30 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC , q Glazing U-Factor 6 I V/ R value of ductwork 2 A/C SEER rating 1 C e-?C E jZ REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\LT30BK33.rck TITLE: LOT 30, BLOCK 33 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/ 17/03 DATE OF PLANS: NOVEMBER 1, 2002 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 634 Your Home UA = 567 10.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Ceiling l: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.18 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.18 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.27 Door 2: Glass Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2059 30.0 0.0 72 430 15.0 0.0 26 60 0.640 38 38 0.800 30 490 15.0 0.0 33 66 0.640 42 403 15.0 0.0 24 72 0.640 46 18 0.580 10 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 398 Window 4: Metal Frame:Double Pane with Low-E 27 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab -On -Grade: Unheated 192 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER • 15.0 0.0 29 0.640 17 0.0 200 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the RESchecklnspection Checklist. Builder/Designer 1 6. — "�� Date Jul 29 02 O9sOla Michael IoClure 979 693-2554 p.4 I I Lt �° I I L-A c -7 Now or Formartr j{ Now or Fumsmy Fjhrard FrooNing Edward Froehfvra Vol. 29d6. Pg. 201 Vol. 29M, Pg. 201 1 Sh•narakwli SUWivWor Ptwse 7—A -- - — Voi. P71. Pg. 157 P 1U' .U.E. tv 4v;zu it 11 E — O'l,. 51 — --- — -�10' RUE. Note: Bldg. Sethook Unee -- per City of Cdlegs Station I Z—.ng oroinanoe #ISM I I Lot �156, BJ=k ,-F)- I �� stole: t. _ 20. Sbwandbob S?JMUSAW 7.5 I � 7.5'! Nor or �Qmma 3 �� . Edward Frmhby i I I 3 ! Edward rdF aeh ing vat. 2965. Pg. 201 Vol. 29W, Pg. 201 -Proposed 1 2 I i Residence I 2 1 J I I 8 5 46!SL }} 8 5 Y? in (� n N � 5' P.U.E. dank of Cure 1 NLP��r� �vo 50 R. o.w. M 27' Pamvn&W 1/*/ 4671, Pp. 157 01-74E28.dwg .NcCtUREENG/NEt�h'/NG, lNC • 1!!08 K�nc�efrDiivre, Sui1e� >!i3 • ge S/a�%on Teras 77�5- j919/ 693-3838 ,\ 1 1 Wcsc� Std� Sc at kg I