HomeMy WebLinkAboutRMDL2003-03558 1513 FONTAINE DR BUILDING PERMITPREPARED 12/05/03, 6:55:47 INSPECTION TICKET PAGE 13 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/05/03 ------------------------------------------------------------------------------------------------ ADDRESS 1. 3 FONTAINE DR SUBDIV: FOXFIRE #2 TENANT, NBR:JjjbNDATI0N REPAIR CONTRACTOR ANCHOR FOUNDATION REPAIR PHONE (979) 690-2020 OWNER SPILLER, RICHARD B & PATTY K PHONE PARCEL 277500-0209-0090 APPL NUMBER: 03-00003558 RESIDENTIAL, REMODEL & RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B125 01 12/05/ 3 I BLDG, FINAL TIME: 17:00 12/042003 01 : 02 PM SSTANLEY L ------------------------------------ COMMENTS AND NOTES ----------- ---- -- i BUILDING PERMIT CITY 7P Cui-iii-JEUE TAT I-(T rail 'rzir2~�i'�x `s`"AvE ask COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003558 Date 12/04/03 Property Address . . . . . . 1513 FONTAINE DR Property ID . . 277500-0209-0090 R # . . . . . . . . . . . . . R27619 Tenant nbr, name . . . . . . FOUNDATION REPAIR Application description . . . RESIDENTIAL, REMODEL & RENOVATION Subdivision Name . . . . . . FOXFIRE #2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 13485 Owner Contractor ------------------------ SPILLER, RICHARD B ------------------------ & PATTY K ANCHOR FOUNDATION REPAIR 1513 FONTAINE DR KENNETH C TRIPP COLLEGE STATION TX 778455609 2924 CAIN RD COLLEGE STATION TX 77845 (979) 690-2020 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA .10 INTERIOR WALL TYPE NA SERIAL ZONES 260.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 80.00 Plan Check Fee .00 Issue Date . . . . 12/04/03 Valuation . . . . 13485 Expiration Date . . 6/02/04 Qty Unit Charge Per Extension BASE FEE 15.00 13.00 5.0000 THOU BLDG, VAL 1001-50000 65.00 ---------------------------------------------------------------------------- Special Notes and Comments MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) POST PERMIT CARD ON JOB SITE Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 80.00 80.00 .00 .00 Plan Check Total .00 .00 .00 .00 --------------------------------------- -L - - ---------------------------- BUILDING DEPT REPRE NTATIVE: i APPLICANT: .cam BUILDING PERMIT • CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003558 Date 12/04/03 Grand Total 80.00 80.00 .00 .00 r -DEPT - - - - - REPRESENTATIVE:-- --------- - - - - -- BUILDING -� - ---------------------------- APPLICANT: • • APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1!3 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US c ADDRESS/LOCATION: 1%J i- t ^J �- Fw Of @ Use Onf , DATE. /;)- / / y 3 APPLICATION # QJ 3 TEMP POLE # LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME: �1 ct+A,C>] S� I LL 2 PHONE: CONTRACTO �T N� ►+cs2 (Z,1nrJ� u�1 Ic�i1(HONE: CONTRACTOR ADDRESS: ' SZL4 C,q-, A '-z-S . ELECTRICIAN: HVAC: PLUMBER: SEC/PH GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req ) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ v C� VALUATION: $ 13, �f f- S'-- TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE WATER TAP: SIZE ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE a TRIPLE DETACHED a CARPORT a Official Use Only oil YES NO Plans Examiner Zoning Official • • Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating PIER FOUNDATION DETAILS FOR REPAIR ONLY TO DAMAGED FOUNDATIONS WHERE SPECIFICALLY DESIGNATED EXISTING SLAB i BEAM I GRADEvii 56F > a W_ < SHIM & GROUT .f 8"x8-x12" SOLID CONC 1"MIN. BLOCKS 6 - 04 RODS • 3 EACH WAY ALL CONCRETE TO BE 5 SACK W/ 1-1/2" ROCK f -t STABLE CLAY 27' 1-MIN. JACK SPACE •— POUR CAP & FOOTING AT THE SAME TIME l� I 3 - 44 VERT. W/ M2 TIES S 18" O C. 20- DIAM. FRONT VIEW IAM SIDE VIEW 2924 Cain Road t • College Station, TX 77845 Office: (979) 690-2020 - ' ' Date: Fax: (979) 690-0235 AGREEMENT Anchor Piers LLC, called Contractor, and M4�M25 4Cyy4,zj 15-p/c.Le2 , Owner agree that the sum of $ to be paid as follows: �f�after piers are poured, balance on completion. Contractor will furnish labor, equipment and materials to perform the following described work to the hereinafter described building or structure located at: /S/3 F��✓�4� �'� •p 1 Story _5_'46 Structure Phone (H) 69 3— 216 / (W) LZ'J— a 3 a3 c3 iiu ; cl2i ��) 1. The work shall consist of the installation of 1 a piers with nindiameter shafts drilled to 8" to 12' ,water table rocks and/or man placed objects permitting. The bottom of the shaft will have a bell footing of 20 inches in diameter, unless rock is encountered. 2. Contractor assumes no responsibility for any under slab plumbing. It may currently be cracked, broken, deterio- rated or may do so in the leveling process. Any repairs, if required are the sole responsibility of the owner. 3. Job site will be clean of all excess dirt and material. 4. Contractor will carry all required insurance. 5. When inside piers are called for, contractor will patch floors. Patches will be made with concrete to wooden floor level. Carpet will NOT be stretched. 6. Where surfaces such as concrete floors or patios are broken in order to install piers, Contractor will patch such area. The patches, however, will not match he color or texture of the original material. Special surface such as Flagstone, Spanish Tile, Brick or other such special materials will be restored at a cost in addition to pier installa- tion. 7. In foundation leveling, conditions might appear when work is begun that were not visible when estimate was submitted, such as, insufficient reinforcing steel in concrete slab, and/or other original foundation structural deficiency. In such cases the guarantee becomes invalid. f 8. SPECIAL PROVISIONS: No Subcontractors. /xL4 �'�u/�',P vc3,,> J,J e_;7;-,.J 9. LIFETIME SERVICE AGREEMENT: If any raising is necessary due to settling during the first five years from date of completion of the job, Contractor will re -raise the settled area without cost to the OWNER. For additional years, servicing, if required, will be done at the rate of o `!-= per adjusted pier, labor and materials included, plus or minus the U.S. Consumer Price Index each year. This service agreement applies only to the 25-0 piers installed by Contractor. THIS AGREEMENT TRANSFERABLE TO NEW OWNERS. NOTIFICATION MUST BE TENDERED IN WRITING WITHIN 30 DAYS OF OWNERSHIP. It is understood agreed that in order to perform the above described work it is possible that sheetrock, wallpaper, or other rigid material may crack. Therefore, the above figure does not include any redecorating, repairing, electrical work or the replacement of any material not called for in this agreement. Contractor upon request from owner, will transplant plants and shrubs obstructing operations, and replace same, survival of shrubs and pants cannot be guaranteed. It is understood and agreed that Contractor will furnish all the labor, equipment and material and will perform all necessary work in connection with this job, in a good workmanlike manner. The Owner may order extra work to be done not contemplated by the contract. In which event, a separate Agreement for such work shall be entered between the Owner and the Contractor. No oral representation made by anyone can change or modify this Agreement. This Agreement in order to be binding by both parties, must be signed in the space provided below, ansl the oltinal copy returpo to this qjice within 3,9 days from the date shown above. Owner Anchor Piers LLC n er