Loading...
HomeMy WebLinkAboutRES2003-03542 4217 DROGO CT BUILDING PERMITPREPARED 8/02/04, 7:37:17 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/02/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 4217 DROGO CT SUBDIV: CASTLEGATE SEC 10,11,12,13 CONTRACTOR T D T HOMES PHONE (979) 690-7117 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-0102-0680 APPL NUMBER: 03-00003542 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/11/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 12/11/03 AP 12/11/2003 10:33 AM GCARRILLO * Strings On Setbacks O.K. Slab Ground Installed B115 '01 1/07/04 TB BLDG, FRAMING TIME: 17:00 1/07/04 AP O1/07/2004 03:12 PM SSTANLEY B125 01 8/0 /04 BI BLDG, FINAL TIME: 17:00 b� 07/30/2004 12:48 PM GCARRILLO ----------------- COMMENTS AND NOTES ---- - ----------------- City of College Station FIORK REQUEST REQ/JOB: WF0477358 / 001 PROJECT: CREW: LOCATION: 4217 DROGO CT 77845 PAGE 1 REQUEST DATE: 12/03/03 PRINT DATE: 12/03/03 PRINT TIME: 10:14:37 SCHEDULE DATES START: 12/03/03 COMPLETION: 12/03/03 GEN. LOC: COLLEGE STATION LOC ID: 197974 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: T D T HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 4" SEWER TAP AND 3/4" WATER TAP 4" SEWER TAP AND 3/4" WATER TAP Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE Mandi Alford - Insulation request inspection result, 4217 Drogao, #03-3542 Page 1 From: Brian Henry To: Alford, Mandi; Stanley, Susan Date: 1 /9/2004 8:43:13 AM Subject: Insulation request inspection result, 4217 Drogao, #03-3542 Print for File Inspected insulation, 4217 Drogao, #03-3542, Benchmark Homes, 1-9-04 Inspection result: Inspected OK for Good Cents CC: Carrillo, Gina BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS'AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003542 Date 12/03/03 Property Address . . . . . . 4217 DROGO CT Property ID . . . . . . . . . 184200-0102-0680 R # . . . . . . . . . . . . . R115312 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 10 & 13 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 107580 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD T D T HOMES 4490 CASTLEGATE DR GLENN THOMAS COLLEGE STATION TX 778453388 1110 12TH MAN COLLEGE STATION TX 77845 (979) 690-7117 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2191.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 484.00 Plan Check Fee .00 Issue Date . . . . 12/03/03 Valuation . . . . 107580 Expiration Date . . 6/01/04 Qty Unit Charge Per Extension BASE FEE 460.00 8.00 3.0000 THOU BLDG, VAL 100001-500000 24.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------------------- BUILDING DE APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003542 Page 2 Date 12/03/03 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES BUILDING DE APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION* 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003542 Date 12/03/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 484.00 484.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1234.00 1234.00 .00 .00 ------------------- BUILDING DE APPLICANT: 13 AWMATION FOR43UIL91NG PERV CIIWOF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION. TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W-CLCOLLEGESTATION.TX.Us ADDRESS/LOCATIQN: LOT _ �(;% Bt_ BUSINESS/OWNER NAME: cc) yz—� 5 PHONE: %" r-,—'70 CONTRACTOR/HOMEOWNER: Q PHONE:41 Z 5 ., CONTRACTOR ADDRESS: ELECTRni��Ics HVAC: a PLUMBER: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE:``�Y T� , HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN I COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: (Cost Iq 1. HEATED AREA: [6M f La 0 or a na PUBLIC SEWER ! D 7J!J✓ SEPTIC/TREATMENT SYSTE W SEWER TAP: WATER TAP: El OTHER TAP: TEMP POLE(NIP) GARAGE TYPE: LI SQE 3 1I S¢E b-.I N SINGLE a ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE -4 SIGNATURE OF APPLICANT: Official Use Only Plans Examiner 2- V tip ©fd lr�i�HLc� P TRIPLE ED CARPORT a ts: YES NO Zoning Official 0 1 , • Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value -of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating • REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release la Data filename: C:\Program Files\Check\REScheck\REScheck docs\ I 64TDT.rck TITLE: TDT Job 164 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11 /25/03 DATE OF PLANS: November 26, 2003 PROJECT INFORMATION: TDT 164 4217 Drogo Court College Station, Texas 77845 COMPANY INFORMATION: TDT Homes 1110 12th Man Court College station, Texas 77845 NOTES: Like Home at 3202 Neuburg COMPLIANCE: Passes Maximum UA = 728 Your Home UA = 561 22.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.34 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame with Thermal Break:Double Pane with Low-E SHGC: 0.34 Door 1: Solid Door 2: Glass SHGC: 0.34 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1630 30.0 0.0 57 1752 13.0 3.4 103 233 0.650 151 21 0.400 8 21 0.650 14 219 0.0 228 Furnace 1: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the RES check Inspection Checklist. Builder/Designer Date • REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 11 /25/03 TITLE: TDT Job 164 Bldg. Dept. Use I Ceilings: l . Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: Windows: 1. Window 1: Metal Frame with Thermal Break:Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.400 Comments: 2. Door 2: Glass, U-factor: 0.650 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 13 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts I" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)