Loading...
HomeMy WebLinkAboutRMDL2003-03538 400 WALTON DR BUILDING PERMITPREPARED 6/14/05, 7:23:37 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/14/05 ------------------------------------------------------------------------------------------------ ADDRESS . : 400 WALTON DR SUBDIV: COLLEGE HILLS CONTRACTOR SCHIEFFER CONSTRUCTION PHONE (979) 778-9511 OWNER LINDSAY, HUGH W PHONE PARCEL 194000-0060-0010 APPL NUMBER: 03-00003538 RESIDENTIAL, REMODEL & RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 4/07/04 OC BLDG, FRAMING TIME: 17:00 4/07/04 AP 04/06/2004 03:45 PM SSTANLEY B Q01 4/20/04 OC BLDG, INSULATION TIME: 17:00 4/20/04 AP 04/19/2004 03:25 PM SSTANLEY homeowner did insulation )B125 01 6/14/05 BI BLDG, FINAL TIME: 17:00 - r?,= ���' T/S: 06/13/2005 01:13 PM SSTANLEY ---------------------- ------------------------------------ COMMENTS AND NOTES -------------------------------------- i i CITY OF COLLEGE STATION WORK REQUEST REQ/JOB: WF0547242 / 001 PROJECT: CREW: LOCATION: 400 WALTON DR GEN. LOC: COLLEGE STATION PAGE 1 PRINT DATE: T DATE: 7/21/ 04 04 PRINT TIME: 9:51:23 SCHEDULE DATES START: 7/21/04 COMPLETION: 7/21/04 118532 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: Hugh Lindsay ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE temp pole passed ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- temp pole passed Category code Task code: Facility ID Assigned Department: J 77840 LOC ID CS -Development Services SET UP NEW UTILITY ACCT OT-CUSTOMER SERVICE CSDS SET At 400 Walton Dr. Work List: Demolition and framing: Cut through east side of carport; rebuild with wall and new back door, according to drawings, using old brick where possible and matching new brickwork to old. Add on to existing concrete slab as shown. Concrete floor --red, green, or saddle. Cut through north side for new window, as shown in drawings. Remove kitchen counters and cabinets,(to be saved when possible, and replace according to drawings. (Counters will be Silestone.) Repair kitchen floor where damaged. (Vinyl flooring) Cut into partition wall in kitchen to add room for refrigerator and counter space, as shown in drawings. ._� Remove existing east kitchen window and replace with door (old hall door). Door to hall pantry will be relocated slightly and dimensions diminished due to kitchen expansion. Hole cut in kitchen floor for down draft ventilation on stove, as shown in drawings. Remove hall door to dining room, as shown in drawing. Cabinets added to sewing room and sitting room. Change air return duct as shown (hallway). Cut some partition wall in master bedroom to build door to bathroom, as shown in drawings, as well as partition wall between closets. Replace existing attic access with more convenient folding ladder access. Replace furnace in attic. Move hot water heater to attic, and finish that space as linen closet. New ducts to be metal and insulated. Electrical: Underground elec.service from outside pole to house. Complete rewiring of house to code, as shown in drawing, with grounding of all outlets.New light switches placed near doors. NL Ccla� �m;;i�e �k(_ci'v� � I��cCv C6�1(iCsL�tQ Windows: Replacement of all exisiting windows and new windows where shown, to code. Finishing: Walls: Shiny, pebbled surface on all walls and ceilings except kitchen: sand, walls remudded for smooth surface and repaint. Guest room wall papered. Wood floors: sand and refinish. Aluminum roof. repair and repaint. Original front door: strip and repaint. Concrete Loop driveway: type finish .$Ij,ILD,IN,0 PERMI-T - �, • CITY QF.COLLEGE STATION . 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------------------------------------------ Application Number . . . . . 03-00003538 Date 12/09/03 Property Address 400 WALTON DR Property ID . . . . . . . . . 194000-0060-0010 R # . . . . . . . . . . . . . R23634 Application description . . . RESIDENTIAL, REMODEL & RENOVATION Subdivision Name . . . . . . COLLEGE HILLS Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 30000 Owner Contractor ------------------------ LINDSAY, HUGH W ------------------------ SCHIEFFER CONSTRUCTION 412 TARROW ST 2103 TABOR RD COLLEGE STATION TX 778407811 BRYAN TX 77803 (979) 778-9511 ---------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 2430.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 183.00 ------------------------------------------------------------------------ Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 160.00 Plan Check Fee .00 Issue Date . . . . 12/09/03 Valuation . . . . 30000 Expiration Date . . 6/07/04 Qty Unit Charge Per Extension BASE FEE 15.00 29.00 5.0000 THOU BLDG, VAL 1001-50000 145.00 ------------------------------------------------------------------------ Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LAND LEVEL WITH THE INTERIOR FLOOR FOR BUILDING DEPT/R PRE ENTATIVE: APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003538 Date 12/09/03 ------------------------------------------------------------------------ Special Notes and Comments EXIT DOOR (S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES smoke detectors need to be located inside and outside of every bedroom. all bedrooms need to be on arc fault breakers and gfi outlets need to be installed where the code calls for them. replaced ductwork needs to be r-8 unless whole system is upgraded to 12 seer. all windows installed need to meet energy code requirements and need to be LoE windows. Fee summary phred PaidC i d Due -------------------------- BUILDING DEPT RENTATIVE: APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003538 Date 12/03/03 --------------------------------------------------------- Permit Fee Total 160.00 160.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 160.00 160.00 .00 .00 I � r------------------t -------------------------- - - ------------------- BUILDING DEPT E /NTATIVE: APPLICANT:/ __v r_1 L-J APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77.. (979) 764-3570 (979) WWW.CLCOLLEGE ON.TX.US ADDRESS/LOCATION: y60 V ! QvJ X LOT BLOCK IVISION BUSINESS/OWNER NAME: CONTRACTOR/HOM CONTRACTOR ADDRESS: ELECTRICIAN: HVAC: __Mv ACCESSORY/STORAGE ADDITION DEMOLITION (Asbestos DUPLEX (Landscape Plar Req) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION TEXAS ACCESSIBILITY STAN VALUATION: $��� (Cost of Labor, 14 PUBLIC SEWER SEPTIC/TREATMENT SYSI ❑ SEWER TAP: S ❑ WATER TAP: f S OTHER TAP: & Imo, e44c ,(— PLUMBER: GOOD CEP CLASS OF WORK F- Off- Um0* DATE: '_ APPLICATION # TEMP POLE # SEC/PH PHONE: PHONE: ,Z&Q, G`'{V3 77%-r,Sr( only): LOCATION RE -ROOF (Total/Partial) MOVING SHELL ONLY iey) NEW CONSTRU ON SLAB ONLY REMODEL/R NATION SWIMMING POOL x N REVIEW COMMITTEE APPROVAL: ON# EABPRJ %L:,2KI) HEATED AREA: NUMBER OF Bpn �' Q NUMBER OF BATHROd r' INTERIOR WALL TYPE: EXTERIOR WALL TYPE: 14- FOUNDATION TYPE: ic 2'Kj S h«f TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE a TRIPLE ATTACHED E ACHED a CARPORT a SIGNATURE OF APPLICANT: -� Official Use Only ents: 3 YES rNO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating